Loading...
HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONSP G.INEERING Ktl.tl" .1J DATE: 4/4/16 SCANNED BY St. Lucie County Phone 954-784-2941 800-848-1919 Fax 954-784-7875 Order No.: 16-1107 CLIENT: Atlas Roofing ADDRESS: 851 South Deerfield Avenue: Deerfield Beach_ FL 33441 PROJECT: Wynne Building Cora. - Flat Wood Deck ADDRESS: 157 Camino Del Rio: Port St Lucie, FL ASCE 7-10 DESIGN PRESSURE CALCULATIONS In Accordance with Chapter 30, Part I Proiect Information: Height = 10' Length = 200' Width = 107' Parapet Wall: < 3' Design Calculations: Flat Wood Deck Exposure: C Category: II Slope: < 7* Ultimate Windspeed: Vli= 170 mph Basic Windspeed: V�d = 132 mph Kz = 0.85 Velocity Pressure: q = 0.00256*[(0.85)(1.0)(1.0)(132f] = 37.9 psf Width of Pressure Coefficient: 0.1(107') = 10.7' 0.4(10') = 4.0' } use: 4T Effective Wind Tributary Area: <10fl? For parapet height 3 feet or larger, zone three (3) can be treated as zone two (2) (ASCE 7-10). External Pressure Coefficient: 1) GCPl = -1.0 2) GCP2 = -1.8 3) GCP3 = -2.8 Design Pressures: Zone 1 Field: Zone 2 Perimeter: Zone 3 Comers: Internal Pressure Coefficient: 1) GCPi = 0.18 PI = 37.9*(-1.0 - 0.18) = 44.7 psf P2 = 37.9*(-1.8 - 0.18) = -75.1 psf P3 = 37.9*(-2.8 - 0.18) = -113.0 psf 0up Mf®� Construction Material American Concrete Miami Dade Florida Department Engineerinq Council Institute County of Transportation IF ENGINEERING 8 TESTING Page 2 4/4/16 Flat Wood Deck Wynne Building Corp. 157 Camino Del Rio Port St Lucie, FL RAS 117 Design Pressure Calculations: Net Width = 2.95 feet Net Length = 33.9 feet Side Lap Row = 50.9 fasteners / square Center Rows = 152.7 fasteners / square 0.49 ft2 / fastener Fy = 25.8 lbs per fastener Attachment Requirements: Based on RAS-117 and N.O.A. #14-0529.02; fastening option number 1 with a design pressure of -52.5 psf; page 24 of 42, the following are our recommended base sheet fastening requirements: Zone 1 Field: 8" o.c. @ laps and 3 staggered rows 8" o.c. Zone 2 Perimeter: 8" o.c. @ laps and 5 staggered rows 8" o.c. Zone 3 Comers: 6" o.c. @ laps and 6 staggered rows 6" o.c. Notes: Sincerely;. Keith laBlanc, P.E. FederalT-ng`inee g & Testing, Inc. Florida Reg. No. 59394 Certificate of Authorization #5471 Miami-Dadb County Certification #11-0407.01 I'll Comers and perimeter area dimension shall not be less than a = 4'0" All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and the Florida Building Code 2014 edition. Wind load calculations based on ASCE 7-10 and information provided by client. All work shall be inspected by our field engineer or city inspector to verify compliance with specifications. Membrane Type: Deck Type 1I: SBS Modified Wood, Non -Insulated Deck Description: 19/32" or greater plywood or wood plank System Type E(4): Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet or Flintglas Premium Ply Sheet Type VI mechanically attached as detailed below. Fastening: Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c. Ply Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase (Optional) Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or one or more plies of Flintglas Ply Sheet Type IV or Flintglas Premium Ply Sheet Type VI adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq. or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic Ultra Poly SMS Base Sheet torch adhered. Membrane: One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic Premium GMS, Flintlastic Premium GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -52.5 psf. (See General Limitation #7) Pressure: L _ _ APPROVED NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 24 of 42 e d e e a' Phone 954-784-2941 800-848-1919 a resrlNc C. Fax 954-784-7875 BY St. Lucie County RECEI'.'�D APR 111056 DATE: 4/4/16 Order No.: 16-1107 CLIENT: Atlas Roofing ADDRESS: 851 South Deerfield Avenue: Deerfield Beach, FL 33441 PROJECT: Wynne Building Corp. Flat Wood Deck ADDRESS: 157 Camino Del Rio: Port St Lucie, FL ASCE 7-10 DESIGN PRESSURE CALCULATIONS In Accordance with Chapter 30, Part I Proiect Information: Height = 10' Length = 200' Width = 107' Parapet Wall: < 3' Desien Calculations: Flat Wood Deck Exposure: C Category: II Slope: < 7* Ultimate Windspeed: V I 170 mph Basic Windspeed: V d =132 mph Kz = 0.85 Velocity Pressure: q = 0.00256*[(0.85)(1.0)(1.0)(132f] = 37.9 psf Width of Pressure Coefficient: 0.1(107') = 10.7' 0.4(10') = 4.0' } use: 4'0" Effective Wind Tributary Area: <10ft For parapet height 3 feet or larger, zone three (3) can be treated as zone two (2) (ASCE 7-10). External Pressure Coefficient: 1) GCPI = -1.0 2) GCP2 = -1.8 3) GCP3 = -2.8 Desien Pressures: Zone 1 Field: Zone 2 Perimeter: Zone 3 Comers: Internal Pressure Coefficient: 1) GCPi = 0.18 PI = 37.9*(-1.0 - 0.18) = -44.7 psf P2 = 37.9*(-1.8 - 0.18) = -75.1 psf P3 = 37.9*(-2.8 - 0.18) = -113.0 psf MI®O.. Construction Material American Concrete Miami Dade Florida Department Enpineerinp Council Institute County of Transportation Page 2 4/4/16 Flat Wood Deck Wynne Building Corp. 157 Camino Del Rio Port St Lucie, FL , RAS 117 Design Pressure Calculations: Net Width = 2.95 feet Net Length = 33.9 feet Side Lap Row = 50.9 fasteners / square Center Rows = 152.7 fasteners / square 0.49 ft2 / fastener Fy = 25.8 lbs per fastener Attachment Reauirements: Based on RAS-117 and N.O.A. #14-0529.02; fastening option number 1 with a design pressure of -52.5 psf; page 24 of 42, the following are our recommended base sheet fastening requirements: Zone 1 Field: 8" o.c. @ laps and 3 staggered rows 8" o.c. Zone 2 Perimeter: 8" o.c. @ laps and 5 staggered rows 8" o.c. ' Zone 3 Comers: 6" o.c. @ laps and 6 staggered rows 6" o.c. Notes: Corners and perimeter area dimension shall not be less than a = TO" All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and the Florida Building Code 2014 edition. Wind load calculations based on ASCE 7-10 and information provided by client. All work shall be inspected by our field engineer or city inspector to verify compliance with specifications. Sincerely, Keith LeBlanc, P.E, Federal Engineering & Testing, Inc. Florida Reg. No. 59394 Certificate of Authorization 95471 Miami -Dade County Certification #11-0407.01 F