HomeMy WebLinkAboutNOA 2RECEI`i-D APR 112016
SCANNED
MIA St. Luce County MIAMI-DADS COUNTY
EM PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 31525-99
NOTICE OF ACCEPTANCE (NOA) w .miamidade.eov/eeonomv
CertainTeed Corporation
18 Moores Road
Malvern, PA 19355
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: CertainTeed Modified Bitumen Roofing Systems over Wood Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA # 14-0224.03 and consists of pages 1 through 42.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 14-0529.02
Expiration Date: 06/19/18
Approval Date: 09/24/15
Page I of 42
ROOFING SYSTEM APPROVAL
Category:
Roofing
Sub -Category:
Modified Bitumen
Material:
APP/SBS
Deck Type:
Wood
Maximum Design Pressure:
-127.5 psf.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test
Product
Product
Dimensions
Specification
Description
All Weather/Empire Base
39 3/s" x 65' 10";
ASTM D 4601, Type Asphalt coated, fiberglass reinforced
Sheet
Roll weight: 701bs.
11
base sheet.
(2 squares)
UL Type G2
Flexiglas Base Sheet
39 %" x 98'9'; Roll
ASTM D 4601, Type Modified Bitumen coated fiberglass
weight: 90 lbs.
II
base sheet.
(3 squares)
UL Type G2
Flintlastic Base 20
39 %" x 49' 6"; Roll
ASTM D 6163,
Modified Bitumen coated fiberglass
weight: 90 lbs.
Grade S, Type I
base sheet.
(1.5 squares)
Flintglas Ply Sheet Type IV
39 3/81, x 1647% Roll
ASTM D 2178, Type Fiberglass, asphalt impregnated ply sheet.
weight: 38 tbs.
IV
(5 squares)
UL Type GI
Flintglas Premium Ply Sheet
39 3/s" x 1647; Roll
ASTM D 2178, Type Fiberglass, asphalt impregnated ply
Type VI
weight: 401bs.
VI
sheet.
(5 squares)
UL Type GI
Flintlastic STA
39 3/e" x 32' 10'; Roll
ASTM D 6222,
Smooth surfaced APP Modified
weight: 871bs.
Grade S, Type I
Bitumen membrane with non -woven
(I square)
polyester mat reinforcement for torch
application.
Flintlastic GTA
39 3/s" x 32' 10"; Roll
ASTM D 6222,
Granule surfaced APP Modified
weight: 105 lbs.
Grade G, Type I
Bitumen membrane with non -woven
(I square)
polyester mat reinforcement for torch
application.
Flintlastic GTA-FR
39 3/a" x 32' 10"; Roll
ASTM D 6222,
Granule surfaced APP Modified
weight: 105 lbs.
Grade G, Type I
Bitumen membrane with non -woven
(1 square)
polyester mat reinforcement for torch
application.
Flintlastic GMS
39 3/8" x 32' 10' ; Roll
ASTM D 6164,
Granule surfaced SBS Modified
weight: 94 lbs.
Grade G, Type I
Bitumen membrane with non -woven
(1 square)
polyester mat reinforcement for mop
application.
NOA No.: 14-0529.02
Expiration Date: 06/19/18
Approval Date: 09/24/15
Page 2 of 42
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE
1
Test
Product
Product
Dimensions
Specification
Description
Flintlastic Premium GMS
39 3/8" x 32' 10'; Roll
ASTM D 6164,
Granule surfaced SBS Modified
weight: 101 lbs.
Grade G, Type B
Bitumen membrane with non -woven
(1 square)
polyester mat reinforcement for mop
application.
Flintlastic FR-P
39 3/8" x 32' 10' ; Roll
ASTM D 6164,
Fire resistant, granule surfaced SBS
weight: 101 lbs.
Grade G, Type I
Modified Bitumen Membrane with
(1 square)
non -woven polyester mat
reinforcement for mop application.
Flintlastic Premium FR-P
39 3/s" x 32' 10' ; Roll
ASTM D 6164,
Fire resistant, granule surfaced SBS
weight: 101 lbs.
Grade G, Type II
Modified Bitumen Membrane with
(1 square)
non -woven polyester mat
reinforcement for mop application.
Flintlastic FR Dual Cap
39 3/s" x 32' 10'; Roll
ASTM D 6162,
Granule Surfaced SBS modified
weight: 103 lbs.
Grade G, Type I
bitumen membrane with a nonwoven
(1 square)
polyester/fiberglass composite mat
reinforcement for use in cold or mop
applications.
Flintlastic FR Cap 30
39 3/s" x 32' 10'; Roll
ASTM D 6163,
Fire resistant, granule surfaced SBS
weight: 86 lbs.
Grade G, Type I
Modified Bitumen membrane with
(1 square)
fiberglass mat reinforcement for mop
applications.
Flintlastic FR Cap 30 T
39-3/8" x 32' 10'; Roll
ASTM D 6163,
Granule surfaced SBS Modified
weight: 100 lbs.
Grade G, Type I
Bitumen membrane with fiberglass
(1 square)
mat reinforcement for torch
application.
Flintlastic Base 20 T
39-3/8" x 33'; Roll
ASTM D 6163,
Modified Bitumen, coated fiberglass
Weight: 81 lbs.
Grade S, Type I
base sheet for torch application.
(1 square)
Flintlastic FR Cap 30 CoolStar
39 3/s" x 32' 10'; Roll
ASTM D 6163,
Fire resistant, granule surfaced SBS
weight: 88 lbs.
Grade G, Type I
Modified Bitumen membrane with
(1 square)
fiberglass mat reinforcement for mop
applications. Covered with reflective
CoolStar Coating.
Flintlastic FR Cap 30 T
39 3/s" x 32' 10"; Roll
ASTM D 6163,
Fire resistant, granule surfaced SBS
CoolStar
weight: 102 lbs.
Grade G, Type I
Modified Bitumen membrane with
(1 square)
fiberglass mat reinforcement for mop
applications. Covered with reflective
CoolStar Coating.
NOA No.: 14-0529.02
Expiration Date: 06/19/18
Approval Date: 09/24/15
Page 3 of 42
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test
Product
Product
Dimensions
Specification
Description
Flintlastic GTA CoolStar
39 3/s" x 32' 10'; Roll
ASTM D 6222,
Granule surfaced APP Modified
weight: 106 lbs.
Grade G, Type I
Bitumen membrane with non -woven
(1 square)
polyester mat reinforcement for torch
application. Covered with reflective
CoolStar Coating.
Flintlastic GTA-FR CoolStar
39 3/8" x 32' 10'; Roll
ASTM D 6222,
Granule surfaced APP Modified
weight: 106 lbs.
Grade G, Type I
Bitumen membrane with non -woven
(I square)
polyester mat reinforcement for torch
application. Covered with reflective
CoolStar Coating.
Flintlastic GMS CoolStar
39 3/8,' x 32' 10'; Roll
ASTM D 6164,
Granule surfaced SBS Modified
weight: 97 lbs.
Grade G, Type I
Bitumen membrane with non -woven
(1 square)
polyester mat reinforcement for mop
application. Covered with reflective
CoolStar Coating.
Flintlastic Premium GMS
39 3/8,' x 32' 10' ; Roll
ASTM D 6164,
Granule surfaced SBS Modified
CoolStar
weight: 103 lbs.
Grade G, Type II
Bitumen membrane with non -woven
(1 square)
polyester mat reinforcement for mop
application. Covered with reflective
CoolStar Coating.
Flintlastic FR-P CoolStar
39 3/8" x 32' 10'; Roll
ASTM D 6164,
Fire resistant, granule surfaced SBS
weight: 103 lbs.
Grade G, Type I
Modified Bitumen Membrane with
(1 square)
non -woven polyester mat
reinforcement for mop application.
Covered with reflective CoolStar
Coating.
Flintlastic Premium FR-P
39 3/8,' x 32' 10'; Roll
ASTM D 6164,
Fire resistant, granule surfaced SBS
CoolStar
weight: 103 lbs.
Grade G, Type II
Modified Bitumen Membrane with
(1 square)
non -woven polyester mat
reinforcement for mop application.
Covered with reflective CoolStar
Coating.
Flintlastic Ultra Poly SMS
39 3/s" x 32' 10"; Roll
ASTM D 6164,
Smooth surfaced SBS Modified
Base Sheet
weight: 90 lbs. (I
Grade S, Type I
Bitumen Membrane with non -woven
squares)
polyester mat reinforcement for mop
applications.
Glasbase Base Sheet
36" x 98' 9' ; Roll
ASTM D 4601, Type Asphalt coated, fiberglass base sheet.
weight: 75 lbs.
II,
(3 squares)
UL Type G2
MA MADE COUNTY
NOA No.: 14-0529.02
Expiration Date: 06/19/18
Approval Date: 09/24/15
Page 4 of 42
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Product
Flintlastic Poly SMS Base
Sheet
Yosemite Venting Base Sheet
Flintlastic APP Base T
Flintlastic Ultra Glass SA
Black DiamondTM Base Sheet
APPROVED INSULATIONS:
Product Name
FlintBoard ISO
FlintBoarda ISO
ACFoam -II
High Density Wood Fiberboard
Perlite Insulation
DensDeck, DensDeck Prime
H-Shield
ENRGY 3
ENRGY 3 25 PSI
Dimensions
39 3/s" x 64' 3' ; Roll
weight: 90 lbs.
(2 squares)
39 3/$" x 32' 10"; Roll
weight: 85 lbs.
(1 square)
39 3/8" x 65' 4'; Roll
weight: 100 lbs.
(2 squares)
39 3/s" x 33' 11"• Roll
weight: 73 lbs.
(1 square)
36" x 687'; Roll
weight: 78 lbs.
(2 squares)
Multi -Max FA-3
SECUROCK Gypsum -Fiber Roof Board
Test
Product
Specification
Description
ASTM D 4601,
Modified Bitumen coated polyester
Grade S, Type II
base sheet.
UL Type G2
ASTM D 3909
Mineral Surfaced fiberglass reinforced
ASTM D 4897, Type buffer sheet.
II
UL Type G3
ASTM D 6509
Modified Bitumen coated fiberglass
base sheet.
ASTM D 1970
ASTM D 1970
TABLE 2
Product Description
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Wood fiber insulation board
Perlite insulation board
Water resistant gypsum board
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
homogenous fiber reinforced
Self -adhering, fiberglass reinforced,
SBS modified bitumen base/ply sheet.
Self -adhering fiberglass reinforced
modified bitumen base sheet
Manufacturer
(With Current NOA)
CertainTeed Corporation
CertainTeed Corp.
Atlas Roofing Corp.
Generic
Generic
Georgia Pacific Gypsum LLC
Hunter Panels LLC
Johns Manville Corp.
Johns Manville Corp.
RMax Operating, LLC
USG Corp.
NOA No.: 14-0529.02
Expiration Date: 06/19/18
Approval Date: 09/24/15
Page 5 of 42
APPROVED FASTENERS:
TABLE 3
Fastener
Product
Product
Manufacturer
Number
Name
Description
Dimensions
(With Current NOA)
1.
Trufast #12 DP Fastener
Insulation fastener for wood
various
Altenloh, Brinch & Co. U.S.,
and steel decks
Inc.
2.
Trufast 3" Metal
Galvalume steel plate
3" round
Altenloh, Brinch & Co. U.S.,
Insulation Plate
Inc.
3.
FlintFast #12
Coated, carbon steel screw
various
CertainTeed Corp.
4.
F1intFast 3" Insulation
Galvalume AZ50 steel plate
3" round
CertainTeed Corp.
Plate
5.
F1intFast #14
Insulation fastener for wood
various
CertainTeed Corp.
and steel decks
6.
Simplex MAXX Cap
Polymer fastner
1" long
Simplex Nails, Inc.
7.
OMG #12 Standard
Insulation fastener for wood
various
OMG, Inc.
Roofgrip
and steel.
8.
OMG 3" Galvanized Steel
Galvalume stress plate
3" round
OMG, Inc.
Plates
9.
Trufast #14 HD Fastener
Insulation fastener for wood
various
Altenloh, Brinch & Co. U.S.,
and steel decks
Inc.
10.
OMG Heavy Duty
Insulation and membrane
Various
OMG, Inc.
fastener
11.
OMG 3 in. Round Metal
Galvalume AZ50 steel plate
Y round
OMG, Inc.
Plates
12.
AccutTrac Hextra
Carbon steel fastener
Various
OMG, Inc.
13.
AccuTrac Plates
Galvalume stress plate.
3" square
OMG, Inc.
14.
AccuTrac Flat Bottom
A2-SS aluminized steel plate
3" square
OMG, Inc.
Plates
NOA No.: 14-0529.02
Expiration Date: 06/19/18
Approval Date: 09/24/15
Page 6 of 42
APPROVED SURFACING/COATING OPTIONS:
TABLE 4
Chosen components must be applied according
to manufacturer's application instructions. Any coating, listed
below, used as a surfacing, must be listed within a current NOA.
System Number Manufacturer
Application
1. Generic
Gravel applied at 400 lbs/sq., adhered with flood coat of asphalt at
60 lbs/sq.
2. Generic
Slag applied at 300 lbs/sq., adhered with flood coat of asphalt at 60
lbs/sq.
3. Karnak Corp.
Karnak (#97 AF) Fibrated Aluminum Roof Coating applied at an
application rate of 1.5 gal/sq.
4. CertainTeed Corp.
FlintCoat A-150 applied at an application rate of 1.5 gal/sq.
5. Gardner Asphalt Corp.
APOC #212 Fibered Aluminum Roof Coating applied at an
application rate of 1.5 gal/sq.
6. Gardner Asphalt Corp.
APOC #400 Sunbrite applied at an application rate of 3 gal./sq.
NOA No.: 14-0529.02
MIAMMADE COUNTY
. • • • � � Expiration Date: 06/19/18
Approval Date: 09/24/15
Page 7 of 42
EVIDENCE SUBMITTED:
Test Agency/Identifier
Name
Reno
Date
Factory Mutual Research Corp.
FM 4470
3Y8A1.AM
03/23/96
FM 4470
OD3A3.AM
04/04/97
FM 4470
2DOAO.AM
12/23/98
FM 4470
iD7A4.AM
11/09/98
FM 4470
3039046
06/15/10
FM 4470
3048520
09/19/13
Underwriters Laboratories, Inc.
UL 790
R11656
01/11/13
United States Testing Company
ASTM D 5147
97457-4
06/03/88
ASTM D 5147
97457-2R
12/02/87
Momentum Technologies, Inc.
ASTM D 4601
AX31G813
09/05/08
ASTM D6164
AX31G8F
06/05/09
ASTM D6222
AX31G8G
06/05/09
ASTM D 3909/ D 4897
AX31G8C
09/05/08
TrinitylERD
TAS 114(J)
3504.06.01-1
06/05/01
TAS 114(J)
3507.08.99-1
04/18/01
TAS 117 (B)
3503.10.06
10/10/06
TAS 117 (B)
06490.04.07-R1
06/27/07
TAS 114 (H)
Letter
04/05/06
TAS 114
3533.01.06
01/06/06
TAS 114
3521.07.04
07/29/04
TAS 117 (B)/ ASTM D 6862
C8500SC.11.07
11/30/07
TAS 114
C8370.08.08
08/19/08
ASTM Physical Properties
C10080.09.08-R4
03/25/10
ASTM D6164/D4798
C31410.01.11-2
01/10/11
ASTM D4601
C40050.09.12-1
09/28/12
ASTMD1970
C40050.09.12-2
09/28/12
ASTM D5147/D4798
C31410.10.10-R1
11/01/12
ASTM 135147/134798
C31410.01.11-1-R1
11/01/12
ASTMD1876
C35460.05.11
06/16/11
ASTM D1876, TAS 114 (H),
C42110.08.12
08/13/12
TAS 117 (B)
FM 4474/TAS 114
C39670.08.12
08/20/12
TAS 117B
C35500.02.11
02/09/11
ASTM D4798
C31410.01.11-2A-Rl
02/21/13
ASTM D4798
C31410.12.13
12/05/13
ASTM D6222
C40050.12.13-R1
12/31/13
TAS 117, TAS 114
C30310.12.09-111
03/07/14
ASTM 131876, TAS 114 (H),
C45620.03.14
03/27/14
FM 4474
ASTM D1876, TAS 114 (H),
C47320.03.14-Ri
04/01/15
FM 4474
PRI Construction Materials
ASTM D6163
CTC-032-02-01
01/22/08
Technologies LLC
ASTM D6163
CTC-066-02-01
08/09/11
ASTM D6222
CTC-070-02-01
08/09/11
NOA No.: 14-0529.02
M[AMMADECOUNTY
. • • • , , Expiration Date: 06/19/18
Approval Date: 09/24/15
Page 8 of 42
i
EVIDENCE SUBMITTED:
Test Agency/Identifier Name
Report
Date
ASTM D6164/D4798
CTC-093-02-01
08/09/11
ASTM D2178
CTC-122-02-01
03/13/12
ASTM D2178
CTC-123-02-01
03/13/12
ASTM D4601
CTC-127-02-01
03/13/12
ASTM D6163
CTC-128-02-01
06/11/12
ASTM D6163
CTC-129-02-01
06/11/12
ASTM D6164
CTC-132-02-01
06/11/12
ASTM D6164
CTC-162-02-01
05/09/13
ASTM D6164
CTC-161-02-01
05/09/13
ASTM D6162
CTC-183-02-01
10/02/13
ASTM D6164
CTC-190-02-01
12/02/13
ASTMD1970
CTC-199-02-01
01/22/14
NOA No.: 14-0529.02
MIAMMADE COUNTY
. • • • . , Expiration Date: 06/19/18
Approval Date: 09/24/15
Page 9 of 42
Membrane Type:
Deck Type 1:
SBS Modified
Wood, Non -insulated
Deck Description: 15/32" CDX plywood at 24-inch spans attached with 8d ring shank nails spaced 6-inch ox
System Type E(1): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, All
Weather / Empire Base Sheet, Flintlastic Base 20 or Flintlastic Poly SMS Base Sheet
mechanically attached as detai a below w.
Fastening: Fastened with Simplex MAXX Cap fasteners spaced 9" o.c. in the 2" side lap and 12" o.c. in
two evenly divided, staggered rows in the center of the sheet.
Membrane: One ply of Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar, Flintlastic FR Dual Cap,
Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-
P CoolStar, Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic Premium GMS, Flintlastic
Premium GMS CoolStar adhered to base sheet with approved mopping asphalt applied within
the EVT range and at a rate of 2040 lbs/sq. or one ply of Flintlastic FR Cap 30 T, Flintlastic
FR Cap 30 T CoolStar, torch -applied.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -52.5 psf (See General Limitation #9)
Pressure:
NOA No.: 14-0529.02
Expiration Date: 06/19/18
Approval Date: 09/24/15
Page 21 of 42
WOOD DECK SYSTEM LIMITATIONS:
A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet.
GENERAL LrnuTATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control
Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the
EVT range and at a rate of 20-40 lbsJsq., or mechanically attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size
shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations
when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot
mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at
each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the
strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt
application of either system shall be at a minimum rate of 12 lbs./sq.
Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as
tested in compliance with Testing Application Standard TAS 105.. If the fastener value, as field-tested, are below
275 lbf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum
fastener resistance value in conjunction with the maximum design value listed within a specific system. Should
the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing,
prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered
Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value
taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application
Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing
Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional
Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred
within this NOA, General Limitation #9 will not be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to
Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field,
perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at
enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically
referred within this NOA, General Limitation #7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 14-0529.02
Expiration Date: 06/19/18
Approval Date: 09/24/15
Page 42 of 42
Home Quick Guide Contact Us UL.com
TGFU.R11656
Roofing Systems
Page Bottom
Roofing Systems
See General Information for Roofing Systems
CERTAINTEED CORP R11656
ROOFING PRODUCTS GROUP
20 MOORES RD
MALVERN, PA 19355 USA
"1h-in. thick (minimum) gypsum board or'/4-in. thick (minimum) Georgia-Pacific Gypsum LLC
"DensDeck® Roofboard" or'DensDeck® Prime Roofboard" or "DensDeck® DuraGuardTM
Roofboard" or'/4-in. thick (minimum) United States Gypsum Co. "SECUROCK® Roof Board"
(Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX) may be used in any
existing noncombustible deck Classification. When this is done, the resulting roofing system is
acceptable for use over combustible (15/32-in. thick minimum) roof decks. However, the butt
joints in the gypsum board and Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or
"DensDeck® Prime Roofboard" or "DensDeck® DuraGuardTm Roofboard" are to offset a
minimum of 6-in. with the butt joints in the roof deck. If polystyrene is part of the roof system, it
must be placed below the overlayment board.'/4-in. thick (minimum) United Sates Gypsum Co.
"SECUROCK® Roof Board" (Type FRX-G) and "SECUROCK® Glass -Mat Roof Board" (Type
SGMRX) are limited to a maximum 3:12 slope when used over a combustible roof deck in a
system with any UL Classified insulation except polystyrene."
Any UL Classified insulation may be used underneath 1/z-in. thick (minimum) gypsum board or
1/4-in. thick (minimum) Georgia-Pacific Gypsum LLC 'DensDeck® Roofboard" or 'DensDeck®
Prime Roofboard" or "DensDeck® DuraGuardThl Roofboard" or'/4-in. thick (minimum) United
States Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat
Roof Board" (Type SGMRX) in any existing noncombustible deck Classification.
Mineral Wool Felt, is a suitable alternate for perforated Type 15 asphalt organic felt in the Class
A, B or C roof constructions indicated below.
Type G1 "Flintglas Ply Sheet' Type 4 or "Flintglas Premium Ply Sheet" Type 6 are suitable
alternates for Type 15 organic felt; Type G2 "Glasbase Base Sheet' is a suitable alternate for
Type 15 and Type 30 base sheets; Type G3 "Flintglas MS Cap" is a suitable alternate for Type
30 Cap Sheets. "Flex-I-Glas", "Premium Flex-I-Glas" or "Flintlastic Base 20 Sheet" is a suitable
alternate for the Type G2 glass base and the Type 15 "All-Weather/Empire base sheet'.
Unless otherwise indicated, base sheets are mechanically fastened or spot mopped in place; ply
and cap sheets are hot mopped in place.
Two plies Type G1 may be utilized in place of one ply Type G2.
"Flintlastic Ultra Glass SA" is a suitable alternate for Type G2 "Glasbase Base Sheet'.
'Black Diamond Base Sheet' is a suitable alternate for Type G2 "Glass Base Sheet'.
"Flintlastic SA Nailbase" or "Flintlastic SA Plybase" are suitable alternates for Type G2 base
sheets in Roofing Systems (TGFU) that limit cover applications to self -adhering ply/base sheets
or membranes.
EPS insulation followed by 1/z-in. thick cover board may be utilized in any of the following
systems.
The "YOSEMITE Venting Base Sheet' may be used in any of the following noncombustible
deck roof systems and, where indicated, in combustible roof deck systems.
"Torch APP" may be utilized in any of the following systems that contain "Flintlastic STA".
Flintlastic APP Base T is a suitable alternate for any Type G2 base sheet.
"Flintlastic Ultra Poly SMS" may be used in lieu of 'Poly SMS Base" in all application
Classifications.
References to Type G2 base sheets includes "Channel -Vent GB".
"F1intBoard Iso", "F1intBoard Iso Cold", "FlintBoard Iso-T" or "F1intBoard Iso Plus", may be
used wherever polyisocyanurate insulation is specified.
Uniform thickness or tapered insulation may be used in the following systems provided they do
not exceed the indicated incline or thickness.
"FlintBoardH ISO", "FlintBoardH ISO Cold", "FlintBoardH ISO WF", "FlintBoardH ISO F",
"FlintBoardH ISO NB" and "FlintBoardH ISO DD" may be used wherever polyisocyanurate
insulation is specified.
"FlintBoardH ISO T", "FlintBoardH ISO T Cold" and "FlintBoardH ISO T WF" are acceptable
alternatives to "FlintBoardH ISO", "FlintBoardH ISO WF" and "FlintBoardH ISO Cold",
respectively, provided they do not exceed the indicated incline or thickness of the system.
Any UL Classified EPS, any thickness, may be used below "FlintBoardH ISO", "FlintBoardH
ISO T", "FlintBoardH ISO Cold", "FlintBoardH ISO T Cold", "FlintBoardH ISO WF",
"FlintBoardH ISO T WF", "FlintBoardH ISO F", "FlintBoardH ISO NB" or "FlintBoardH ISO
DD" insulation on non-combustible decks provided a minimum 1-in. thick layer of "FlintBoardH
ISO", "FlintBoardH ISO T", "FlintBoardH ISO Cold", "FlintBoardH ISO T Cold", "FlintBoardH
ISO WF", FlintBoardH ISO T WF", "FlintBoardH ISO F", "FlintBoardH ISO NB" or
"FlintBoardH ISO DD" polyisocyanurate insulation is used. Max incline shall be in accordance
with Classification established for the insulation/membrane roofing system, but cannot exceed
1:12.
For Combustible Roof Decks - Class A:
1. A minimum 3-in. layer or a minimum two layers of 1.5-in. of "FlintBoardH ISO Cold" or
"FlintBoardH ISO T Cold" is placed directly over a combustible roof deck and is covered with
any UL Classified roofing membrane used in any UL Class A roofing assembly to achieve a
Class A fire Classification. As an alternative, any UL Classified insulation (except expanded or
extruded polystyrene), any combination, any thickness, may be used below the 3-in. minimum
total thickness of "FlintBoardH ISO Cold" or "FlintBoardH ISO T Cold". The insulation may be
loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor
barrier (non-UL classified) may also be used below the insulation. All insulation joints must be
staggered a minimum of 6-in. from the butt joints of the roof deck or from the insulation joints
directly below. The maximum incline shall be in accordance with the Classification established
for the membrane/insulation roofing assembly, however the incline cannot exceed 1/2:12.
2. A minimum 1.9-in. layer of "FlintBoardH ISO Cold" or "FlintBoardH ISO T Cold" is placed
over a minimum 1 layer of Carlisle "FR Base Sheet 1S" or GAF "VersaShield FB-IS" over a
combustible roof deck. The insulation is covered with any UL Classified roofing membrane used
in any UL Class A roofing assembly to achieve a Class A fire Classification. As an alternative,
any UL Classified insulation (except expanded or extruded polystyrene), any combination, any
thickness, may be used below the 1.9-in. minimum total thickness of "FlintBoardH ISO Cold" or
"FlintBoardH ISO T Cold". The insulation may be loosely laid or attached with fasteners and
plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may also be
used below the insulation. All insulation joints must be staggered a minimum of 6-in. from the
butt joints of the roof deck or from the insulation joints directly below. The maximum incline
shall be in accordance with the Classification established for the membrane/insulation roofing
assembly, however the incline cannot exceed 1/2:12.
For Combustible Roof Decks - Class B:
1. A minimum 1.9-in. layer of "FlintBoardH ISO Cold" or "FlintBoardH ISO T Cold", or a
minimum 2-in. thick layer of Atlas "AC Foam III" is placed directly over a combustible roof
deck and is covered with any UL Classified roofing membrane used in any UL Class B roofing
assembly to achieve a Class B fire Classification. As an alternative, any UL Classified insulation
(except expanded or extruded polystyrene), any combination, any thickness, may be used below
the 1.9-in. minimum thickness layer of "FlintBoardH ISO Cold" or "FlintBoardH ISO T Cold".
The insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or
cold adhesive. A vapor barrier (non-UL classified) may also be used below the insulation. All
i
insulation joints must be staggered a minimum of 6-in. from the deck joints or from the
insulation joints directly below. The maximum incline shall be in accordance with the
Classification established for the membrane/insulation roofing assembly, however the incline
cannot exceed 1/2:12.
Unless otherwise indicated the following membranes are acceptable alternates for the following
membranes tabulated below, limited to 1/2-in. incline:
Membrane
Acceptable Alternate
Flintglas MS Cap
Flintglas MS Cap CoolStar
Flintlastic GMS
Premium
Flintlastic Premium GMS CoolStar
Flintlastic GTS
Flintlastic GTS CoolStar
Flintlastic Premium
FR-P
Flintlastic FR-Dual Cap, Flintlastic Premium FR-P CoolStar or
Flintlastic FR-Dual Cap CoolStar
Flintlastic FR Cap
30 T
Flintlastic FR Cap 30 T CoolStar
Flintlastic GTA
Flintlastic GTA CoolStar
Flintlastic GMS
Flintlastic GMS CoolStar
Flintlastic SA P-
Cap FR
Flintlastic SA Cap FR CoolStar
Flintlastic GTA-FR
Flintlastic GTA-FR CoolStar
Flintlastic FR-P
Flintlastic FR-Dual Cap or Flintlastic FR-P CoolStar
Flintlastic FR-Cap
30
Flintlastic FR Cap 30 CoolStar
ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT
3. Deck: C-15/32 Incline: 1/2
Insulation (Optional): — Schuller International "U1traGard Premier", polyisocyanurate,
wood fiberboard, perlite, fiberglass, isocyanurate, any thickness.
Base Sheet: — One or more plies of "Glasbase", hot mopped or mechanically fastened.
Membrane: — One ply of "Flintlastic FR" (modified bitumen), hot mopped in place.