Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning &Development Services nt ° Building & Code Regulations isi 1E COPY 2300 Virginia Avenue, Fort Pierce, FL 34982- (772) 462-1553 SCANNED BY Certification for Design Load Compliance St. Lucie County Project Name: Install Rail Car A -Frame Shaker Project Address: 5720 Environmental Dr. Fort Pierce, FL 34982 Permit #: 1603-0125 Occupancy Type: Construction Type: Commercial INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. l i\ * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS ANDASSSUMPTIONS USED: (complete all that apply) I. DESIGN CODE: Florida &,J't � I A q Code Fifth Edition with 20 (T Supplements using ASCE 7-10 e 2. Structure Designed as (check one): _Enclosed _Partially Enclosed Pellopen 3. Risk Category: _I -/—II _III —IV Exposure Category: B ✓ C _D 4. Design Wind Velocity 1�� mph ASO _LRFD End Zone Width: P�-ft 5. Mean Roof Height 3 cl ft Roof Pitch:y &-:12 Parapet: h41%" A< 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): P))l lk Zone 1: Zone 2: Zone 3: � t�Zone 4: Zone�5: Garage: tc 7. Design Loads: Floor: N %a PSF Roof/Dead: �`I k PSF Roof/Live: h`" - Balcony: � A PSF s Dock: PSF Deck: r4 PSF Stairs: ASS PSF /F$nce: PSF Railings:" PSF 8: Were Shear Walls Considered For Structure? _Yes �/ Not Applicable Explain Why Not: s6" t, .-4'0_ kkC� 4il g/" 1� uJ- 1/ 9.- Is A Continuous Load Path Provided? Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure:1, sd 4 PSF Soil Test Reports Submitted? O X Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate "resistance to the design forces specified: Print Name Cert # &OCo. Cert Au-th. t Si nature, bate; and Seal Toil �,� � I�U-J FE 3 S%Dy Company Name &Address Revised 07/25/2014