Loading...
HomeMy WebLinkAboutFEILD DENSITY TEST REPORTAiman & Associates--,'nc. Certificate of Authorization No. 5ydv 460 NW Concourse Place, Unit 1 SCANNED Port St. Lucie, Florida 34986 BY Phone: (772) 878-0072 '+ LUCie County ty FIELD DENSITY TEST REPORT PROJECT: CemexPlant FILE NO.: 16-5465 Environment Drive, Fort Pierce, Florida RECEIVED REPORTED TO: Mid -State Machine & Fabrication Corp. SEP -1 2016 Permit Number 1603-0125��yQ� _ Q/.ems— DATE OF TEST: 8/9/16 and 8/15/16 TEST A -Frame Shaker Foundations MDR. MOISTURE CONTENT DRY PERCENT DEPTH NO. NO. DENSITY COMPACTION LOCATION % 1 NE Footing 1 13.1 , 117.4 99 0 to -1' 2 SE Footing 1 9.0 112.6 96 0 to -1' 3 West Footing 2 9.7 126.0 98 0 to -1' 4 NE Footing (retested on 8/15/16) 1 10.6 113.5 97 0 to -1' 5 SE Footing (retested on 8/15/16) 1 10.8 114.2 97 0 to A' • DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 95 PERCENT. FIELD TEST: ❑ ASTM D-2937 [, ASTM D-6938 ❑ASTM D-2167 ❑ ASTM D-1556 TECHNICIAN: TO Test depth referenced from: LABORATORY MOISTURE -DENSITY RELATIONSHIP Top of Footing Subgrade MDR ASTM MAX, OPTIMUM NO. TEST METHOD DENSITY MOISTURE CONTENT 1 D-1557 118 PCF 7.5 % Remarks: 2 D-1557 129 PCF 8 % ii 6l�V - S' . c7 iiivdl � .T AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORT: FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR 1� 1 an 3. 7 .) In 11 fin I ise # 63911 OF CLIENTS AND AUTHORIZATION )UR WRITTEN APPROVAL. Ai8aman & Associate,fn Certificate of Authorization No. 5950 460 NW Concourse Place, Unit 1 Port St. Lucie, Florida 34986 SCANNED Phone: (772) 878-0072 BY Fax: (772) 878-0097 St. Lucie CountrFIELD DENSITY TEST REPORT D EC EOV MAR — 2 RECD PROJECT: Cemex Plant FILE NO.: 16-5465 Environment Drive, Fort Pierce, Florida REPORTED TO: Permit Number Mid -State Machine &Fabrication Corp. 1603-0125 OLn DATE OF TEST: 8/9/16 and 8/15/16 TEST A -Frame Shaker Foundations MDR. MOISTURE CONTENT DRY PERCENT DEPTH NO. NO DENSITY COMPACTION LOCATION 1 NE Footing 1 13.1 117.4 99 0 to -1' 2 SE Footing 1 9.0 112.6 96 0 to -1' 3 West Footing 2 9.7 126.0 98 0 to -1' 4 NE Footing (retested on 8/16/16) 1 10.6 113.5 97 0 to A' 5 SE Footing (retested on 8/15/16) 1 10.8 114.2 97 0 to 4 * DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 95 PERCENT. FIELD TEST: ❑ ASTM D-2937 [, ASTM D-6938 ❑ ASTM D-2167 E ASTM D-1556 TECHNICIAN: TO Test depth referenced from: LABORATORY MOISTURE -DENSITY RELATIONSHIP Top of Footing Subgrade MDR ASTM MAX. OPTIMUM NO. TEST METHOD DENSITY MOISTURE CONTENT 1 D-1557 118 PCF 7.5 % Remarks: 2 D-1557 129 PCF 8 % AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORT', FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR O f No.63911 STATE ONAVr' l i wIi� k, P.E.' # 63911 'LIENTS AND AUTHORIZATION WRITTENAPPROVAL. � Arden in & Associates, Inc. Florida Certificate of Authorixatlon No. 00006950 MODIFIED PROCTOR (ASTM D-1557) Project Name: CEMEX Plant Date Sampled Project Location: Port St. Lucie, Florida Sampled By: File Number: 16-5465 Date Tested: Client Name: Midstate Machine & Fabricating Tested By: ■ 9 MENReeled �.. � ernE —omm — N ONE 110 • _ ,u n is 10 14 It, 15 17 16 19 20 MOISTURE CONTENT (%) SAMPLE NUMBER: SAMPLE DESCRIPTION: SAMPLE LOCATION: PROPOSED USE: Ourteners and Ol are forthe exWusive use of the diem to Whem they amendreesed and shall not be reproduced except In full adnout the approval of the testing laboratory. The use of ouf name must receive ourwrthen approval. Our legere and reports apply only to the Sample tested me of esteemed. and are not Indicative of the quanhlies of apparently inden all or similar "duds. J. 7t 3 1♦ STATE OF A : ♦♦Ir[nntoP 101VA i'C Ardaman & AaSOdlatos, Inc. 460 NW Concourse Place, Unit 1 Port St Lucie, FL 34986 Phone (772) 878-0072 FAX (772) 878-0097 8/9/2016 8110/2016 TO MAX. DRY DENSITY (pco 118.0 OPTIMUM MOISTURE (%) 7.5 FINES (%) Curves of fee % Saturation for Specific Gravity Equal to: 2.60 2.65 No. 63911