Loading...
HomeMy WebLinkAboutREVIEW COMMENTSPlanning & Development Services Building S Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Fox:(772)46246443 PROPERTYINFORMATION Address: 7131 S U S 1 City / State / Zip: Port St Lucie, FI 34952 Parcel#: 3422-211-0010-00016 Zoning: CG APPLICATION INFORMATION Permit Number: 1604-0597 Permit Type: COMMERCIAL RENOVATION CONTRACTOR INFORMATION REVIEW COMMENTS SCANNED St. LuBy ce County Page 1 Owner(s): Port St Lucie Plaza I Llc / Port St Lucie Plaza li Llc Jurisdiction: SAINT LUCIE COUNTY Lot#: Stories: Contractor Name: Roderick J Waller Business Name: Sunrise City Community Housing Development Org Inc Business Addr: 800 Virginia Ave Ste 61 City / State / Zip: Fort Pierce, FI 34982 REVIEWS AND COMMENTS Review Type FIRE DEPARTMENT REVIEW Comment: FRONT COUNTER REVIEW Comment: PE REVIEW COMMENTS (2) 5/11/2016 Comment: 5/11/2016 Comment: 5/19/2016 Comment: Comment: 5/1912016 Block: Automatic Sprinkler System? No Fax Number: 772-907-0420 Email: Rodwallerl@Gmail.Com Status Reviewed By Date Started Date Completed PENDING Tony Jerger COMPLETE Karen Nielsen 4/29/2016 4/29/2016 4/2912016 INCOMPLETE Joe Clclo 5/19/2016 PLANS ARE INCOMPLETE AND CANNOT CONTINUE REVIEW AT THIS TIME FOR THIS WORSHIP FACILITY' REVIEW REQUIREMENTS WILL BE SENT VIA SEPARATE E-MAIL COMMENT E-MAILED AS OF THIS DATE SECOND PLAN REVIEW' RE -REVIEW FEE DUE" RECEIVED THE SAME PLANS AS ORIGINAL' SECOND PLANS ARE INCOMPLETE AND MUST CONTAIN ALL DETAILS REQUIRED FOR A WORSHIP FACILITY INCLUDING PLUMBING, ELECTRICAL, MECHANICAL, ACCESSIBILITY, ETC. PLEASE SEE THE ATTACHED CHECKLIST FOR PLAN REQUIREMENTS TO START THE REVIEW PROCESS 6/19/2016 Comment: COMMENTS E-MAILED AS OF THIS DATE PLANS EXAMINER ELECTRIC PENDING Walter Pride Comment: PLANS EXAMINER MECHANICAL PENDING Carl Peterson Comment: Planning & Development Services Building &Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982. Phone:V72)462.2172 Fax:(772)662.6dd3 PLANS EXAMINER PLUMBING PENDING Comment: PLANS EXAMINER REVIEW COMPLETE Comment: ZONING REVIEW COMPLETE Comment: REVIEW COMMENTS Greg Smyth Joe Cicio 511112016 Lydia Galbraith 51612016 611912016 6/6/2016 Page 2 6119/2016 516/2016 ,mac. �u,riiA. �iaaror� Planning 8 Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:VI2)462.2172 Fax:(772K62-6443 PROPERTY INFORMATION Address: 7131 S U S 1 City / State / Zip: Port St Lucie, FI 34952 Parcel#: 3422-211-0010-000/6 Zoning: CG APPLICATION INFORMATION Permit Number: 1604-0597 Permit Type: COMMERCIAL RENOVATION REVIEW COMMENTS SCANj- BY St. Lucie Page 1 Owner(s): Port St Lucie Plaza I Llc / Port St Lucie Plaza li Llc Jurisdiction: SAINT LUCIE COUNTY Lot#: Stories: CONTRACTOR INFORMATION Contractor Name: Roderick J Waller Business Name: Sunrise City Community Housing Development Org Inc Business Addr: 800 Virginia Ave Ste 61 City / State / Zip: Fort Pierce, FI 34982 REVIEWS AND COMMENTS Block: Automatic Sprinkler System? No Fax Number: 772-907-0420 Email: Rodwallerl@Gmail.Com Review Type Status Reviewed By Date Started Date Completed Date Released FRONT COUNTER REVIEW COMPLETE Karen Nielsen 412912016 412912016 4129/2016 Comment: PLANS EXAMINER REVIEW INCOMPLETE Joe Cicio 511112016 5/11/2016 Comment: PLANS ARE INCOMPLETE AND CANNOT CONTINUE REVIEW AT THIS TIME FOR THIS WORSHIP FACILITY' REVIEW REQUIREMENTS WILL BE SENT VIA SEPARATE E-MAIL 5/1112016 Comment: COMMENT E-MAILED AS OF THIS DATE ZONING REVIEW COMPLETE Lydia Galbraith 51612016 5/612016 51612016 Comment: Planning S Development Services Building & Code Regulation: Division 2300 Virginia Avenue Fart Pierce, FL 34982 Phone•.(772)462-2172 Fax:(772)462.6443 PROPERTY INFORMATION Address: 7131 S U S 1 City / State / Zip: Port St Lucie, FI 34952 Parcel#: 3422-211-0010-00016 Zoning: CG APPLICATION INFORMATION REVIEW COMMENTS SCANNED BY St. Lucie Countv Owner(s): Port St Lucie Plaza I LIc / Port St Lucie Plaza li Llc Jurisdiction: SAINT LUCIE COUNTY Lot#: Permit Number: 1604-0597 Stories: Permit Type: COMMERCIAL RENOVATION CONTRACTOR INFORMATION Contractor Name: Roderick J Waller Business Name: Sunrise City Community Housing Development Org Inc Business Addr: 800 Virginia Ave Ste 61 City / State / Zip: Fort Pierce, FI 34982 REVIEWS AND COMMENTS Review Type FIRE DEPARTMENT REVIEW Comment: FRONT COUNTER REVIEW Comment: PE REVIEW COMMENTS (2) Comment: PE REVIEW COMMENTS (3) 6/6/2016 Comment: 6/6/2016 Comment: Comment: 6/6/2016 Comment: 6/6/2016 6/7/2016 Comment: 6/7/2016 Comment: Comment: 6/7/2016 Block: Automatic Sprinkler System? No Fax Number: 772-907-0420 Status Reviewed By Date Started PENDING Tony Jerger COMPLETE Karen Nielsen 412912016 COMPLETE Joe Cicio 611912016 INCOMPLETE Joe Cicio 6/612016 THIRD PLAN REVIEW . FEES DUE Email: Rodwallerl@Gmail.Com Date Completed Date Released 4129/2016 616/2016 4/29/2016 6/612016 DESIGN PROFESSIONAL SHOWS THIS AS AN A-2 CLASSIFICATION • PLEASE DESIGN TO THE CORRECT OCCUPANCY CLASSIFICATION PER FBC 303.4 [ PLACES OF RELIGIOUS WORSHIP I DESIGN PROFESSIONAL TO ELIMINATE THE WIND DESIGN CRITERIA IN THE TITLE BOX [ DOES NOT APPLY TO A CHANGE OF OCCUPANCY I AND STATE THE CURRENT, CORRECT CODES PERTAINING TO THIS PROJECT/I BUILDING, M,E,P, ENERGY, ACCESSIBILITY, LIFE SAFETY AND FIRE SHOW THE FULL ACCESSIBLE RESTROOM DETAILS ON PLANS INCLUDING ELEVATIONS, FIXTURE HEIGHTS, CLEAR FLOOR AREAS, WALL, CEILING AND FLOOR FINISHES [ FBC TABLE 803.91 ALL FLAME SPREADS AND SDI [ 803.1.1 [ PLANS MUST BE FULLY DIMENSIONED AND TO SCALE • FBC 107.2.1 • SHOW ALL DOOR SIZES ON PLANS SHOW THE AISLE DIMENSIONS ON PLANS SHOW THE ADJOINING TENANTS ON PLANS WITH THE RATINGS OF THE EXISTING SEPARATION WALLS FBC TABLE 508.4 NEED THE BUILDING OWNERS PHONE NUMBER AND E-MAIL ADDRESS ON THE PERMIT APPLICATION NEED THE DESIGN PROFESSIONAL INFO ON THE PERMIT APPLICATION •• WHICH UNIT IS THIS IN THE PLAZA AS I DO NOT SEE ANY 900 S.F. UNITS ON THE PROP APPRAISER WEB Planning & Development Services Building &: Code ;Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:V72j4622172 Fax:(772)4676443 REVIEW COMMENTS Page 2 6/7/2016 Comment: OCCUPANT LOAD CALCULATION IS NOT CORRECT[ FBC TABLE 1004.1.2 ] 6/7/2016 Comment: SEE FBC 1005.7.1 FOR DOORS REDUCING HALL WIDTHS * BACK RESTROOM AND UTILITY ARE NOT COMPLAINT 6/7/2016 Comment: DESIGN THE EGRESS DOOR HARDWARE ON PLANS PER FBC 1008.1.9.3 6/7/2016 Comment: SHOW THE FRONT ELEVATION OF THE TENANT SPACE WITH THE MALTESE CROSS REQUIREMENTS PER FAC 69A-60.0081 Comment: SHOW AN ACCESSIBLE ROUTE ON THE PLANS FROM THE PARKING AREA INTO AND AROUND THE 6/7/2016 FACILITY * DESIGN THE STAGE RAMP ON PLANS WITH REQUIRED HANDRAILS [ ACCESSIBILITY 405 ] [ ACCESSIBILITY 5051 6/7/2016 Comment: DESIGN PROFESSIONAL TO INCLUDE A WALL, CEILING AND FLOOR FINISHES CHART ON PLANS FOR THE REMAINDER OF THE WORSHIP AREA PER FBC 803.9, 804 AND 808 6/7/2016 Comment: SHOW THE REQUIRED HANDRAILS ON THE STAIRWAY TO THE STAGE PER FBC 1012 6/7/2016 Comment: IS THE CONSTRUCTION PROTECTED OR UN -PROTECTED / PLANS STATE BOTH 6/7/2016 Comment: 6/8/2016 Comment: PLANS EXAMINER ELECTRIC SHOW THE REQUIRED RESTROOM REQUIREMENTS PER FBC 1210.2 [ INTERIOR ENVIRONMENT ] DETAIL ON PLANS COMMENTS E-MAILED AS OF THIS DATE INCOMPLETE Walter Pride 6/612016 Comment: NO ELECTRICAL ON THIS PLAN,NEED TO SHOW ALL EXISTING 6/6/2016 -. ELECTRICAL,RECPS.SWITCHES,LIGHTING,SHOW ALL NEW ELECTRICAL THAT WILL BE ADDED,ELECTRICAL SERVICE PANEL,ETC.WALT PRIDE SR. PLANS EXAMINER MECHANICAL INCOMPLETE Carl Peterson 5/26/2016 Comment: PLEASE SHOW THE ASSEMBLY OCCUPANCY MEETING THE REQUIREMENTS FOR VENTILATION IN THE 5/2612016 FLORIDA MECHANCIAL CODE CHAPTER 4 AS REQUIRED IN SECTION 1009 OF THE FLORIDA EXISTING BUILDING CODE. PLANS EXAMINER PLUMBING INCOMPLETE Greg Smyth 5131/2016 5/31/2016 Comment: 5/3112016 Comment: 5/31/2016 Comment: PLANS EXAMINER REVIEW Comment: ZONING REVIEW Comment: PLEASE SHOW HI LO DRINKING FOUNTAIN PER TABLE 403.1 AND SECTION 410 FLORIDA PLUMBING CODE 2014 AND CHAPTER 210 FLORIDA ACCESSABILITY CODE 2014 PLEASE INDICATE ON PLAN HOT WATER TO ALL SINKS PER SECTION 607.1 FLORIDA PLUMBING CODE 2014. PLEASE SHOW SERVICE SINK PER TABLE 403.1 FLORIDA PLUMBING CODE 2014. COMPLETE Joe Cicto Lydia Galbraith 6/1112016 51612016 611912016 516/2016 511912016 5/6/2016 w Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Fierce, FL 34982 Phone:(772)4622172 Fax:(I72)462.6443 Address: City / State /-Zip: Parcel #: 7131SUS1 Port St Lucie, FI 34952 3422-211-0010-000/6 REVIEW COMMENTS SCANNED BY St. Lucie County 1 Owner(s): Port St Lucie Plaza I Llc / Port St Lucie Plaza li Llc Jurisdiction: SAINT LUCIE COUNTY Zoning: CG Lot#: APPLICATION INFORMATION Permit Number: 1604-0597 Stories: Permit Type: COMMERCIAL RENOVATION CONTRACTOR INFORMATION Contractor Name: Roderick J Waller ' Business Name: Sunrise City Community Housing Development Org Inc Business Addr: 800 Virginia Ave Ste 61 City / State / Zip: Fort Pierce, FI 34982 REVIEWS AND COMMENTS Review Type FIRE DEPARTMENT REVIEW Comment: FRONT COUNTER REVIEW Comment: PE REVIEW COMMENTS (2) Comment: PE REVIEW COMMENTS (3) Comment: PE REVIEW COMMENTS (4) 6/6/2016 Comment: Comment: 6/6/2016 Comment: 6/7/2016 Comment: V//2016 Block: Automatic Sprinkler System? No Fax Number: 772-907-0420 Email: Rodwallerl@Gmail.Com Status Reviewed By Date Started PENDING Tony Jerger COMPLETE Karen Nielsen 4129/2016 COMPLETE Joe Cicio 5/1912016 COMPLETE Joe Cicio 61612016 INCOMPLETE Joe Cicio 8/1/2016 Date Completed Date Released. 4129/2016 4/29/2016 616/2016 61612016 811/2016 8/1/2016 THIRD PLAN REVIEW' FEES DUE ""' FOURTH REVIEW FEES DUE UPON RE -SUBMITTAL" SHOW THE FULL ACCESSIBLE RESTROOM DETAILS ON PLANS INCLUDING ELEVATIONS, FIXTURE HEIGHTS, CLEAR FLOOR AREAS, WALL, CEILING AND FLOOR FINISHES I FBC TABLE 803.91 ALL FLAME SPREADS AND SDI 1 803.1.1 1 ••• DID NOT ADDRESS THE CLEAR FLOOR FIXTURE AREAS PER FBC ACCESS 404, ADAAG 602, DID NOT ADDRESS COMMENTS FOR WALL AND FLOOR FINISHES, FLAME SPREADS OR S.D.I. PLANS MUST BE FULLY DIMENSIONED AND TO SCALE' FBC 107.2.1 • SHOW ALL DOOR SIZES ON PLANS' SHOW THE AISLE DIMENSIONS ON PLANS • COMMENT NOT COMPLETE' WHERE ARE DOORS A AND D LOCATED / NOT ON FLOOR PLANS NEED THE BUILDING OWNERS PHONE NUMBER AND E-MAIL ADDRESS ON THE PERMIT APPLICATION' NEED THE DESIGN PROFESSIONAL INFO ON THE PERMIT APPLICATION " WHICH UNIT IS THIS IN THE PLAZA AS I DO NOT SEE ANY 900 S.F. UNITS ON THE PROP APPRAISER WEB v ,j� �cr�iio � OEH2w� Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)4622172 Fax:(772)462.6443 REVIEW COMMENTS Page 2 6/7/2016 Comment: OCCUPANT LOAD CALCULATION IS NOT CORRECT [ FBC TABLE 1004.1.2 ] 6/7/2016 Comment: DESIGN THE EGRESS DOOR HARDWARE ON PLANS PER FBC 1008.1.9.3 Comment: SHOW AN ACCESSIBLE ROUTE ON THE PLANS FROM THE PARKING AREA INTO AND AROUND THE 6/7/2016 FACILITY `DESIGN THE STAGE RAMP ON PLANS WITH REQUIRED HANDRAILS [ ACCESSIBILITY 405 ] [ ACCESSIBILITY 505 ] •' REMOVE THE NOTE: NO RAILINGS NEEDED: FROM THE PLANS [ FBC 1009.11.5 DOES NOT EXIST IN THE FBC ] Comment: DESIGN PROFESSIONAL TO INCLUDE A WALL, CEILING AND FLOOR FINISHES CHART ON PLANS FOR THE 6/7/2016 REMAINDER OF THE WORSHIP AREA PER FBC 803.9, 804 AND 808 [ INCORRECT ON RE -SUBMITTED PLANS 6/7/2016 Comment: SHOW THE REQUIRED RESTROOM REQUIREMENTS PER FBC 1210.2 [ INTERIOR ENVIRONMENT ] DETAIL ON PLANS [ NOT ON RE -SUBMITTED PLANS ] Comment: CHANGE NOTES ON A-1 ' WE ARE CURRENTLY ENFORCING THE 2011 N.E.C. UNDER THE 2014 BUILDING 8/1/2016 CODE REFERENCES' CHANGE NOTES ON A-1 • THIS IS A CONVERSION FROM GROUP B TO A-3 OCCUPANCY CLASSIFICATION Comment: IS THIS TENANT SPACE SPRINKLED ?? [ NOTE ON PLANS ] // IF NOT THE SEPARATION WALLS ARE 8/1/2016 REQUIRED TO BE 2 HOUR RATED AND THE REAR CORRIDOR MUST BE 1 HOUR RATED WITH OUT A SPRINKLER SYSTEM [ SEE FBC TABLE 1018.1 ] - SHOW ALL DETAILS AND TESTING CRITERIA ON PLANS 8/2/2016 Comment: UPON RESUBMITTAL WE WILL NEED [ 3 ] SETS OF ORIGINAL, SIGNED, DATED AND SEALED DRAWINGS W/ 2 PDF DISCS • PLEASE PAY ALL REQUIRED RE -REVIEW FEES WHEN SUBMITTED PLANS EXAMINER ELECTRIC COMPLETE Walter Pride 6/6/2016 81212016 81212016 Comment: PLANS EXAMINER MECHANICAL INCOMPLETE Carl Peterson 5/2612016 Comment: PLEASE SHOW THE ASSEMBLY OCCUPANCY MEETING THE REQUIREMENTS FOR VENTILATION IN THE 5/2612016 FLORIDA MECHANICAL CODE CHAPTER 4 AS REQUIRED IN SECTION 1009 OF THE FLORIDA EXISTING BUILDING CODE. PLANS EXAMINER PLUMBING COMPLETE Greg Smyth 5131/2016 8/112016 8/1/2016 Comment: PLANS EXAMINER REVIEW COMPLETE Joe Cicio 5/1112016 5/19/2016 5/1912016 Comment: ZONING REVIEW COMPLETE Lydia Galbraith 516/2016 5/612016 5/6I20116 Comment: r Planning S Development Services Building 8. Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462-2172 Fax:(772)462.6443 SCANNED REVIEW COMMENTS BY St. Lucie Countv I Page 1 Address: 7131 S US 1 Owner(s): Port St Lucie Plaza I Llc / Port St Lucie City / State / Zip: Port St Lucie, FI 34952 Plaza li Llc Parcel #: 3422-211-0010-000/6 Jurisdiction: SAINT LUCIE COUNTY Zoning: CG Lot#: Block: APPLICATION INFORMATION Permit Number: 1604-0597 Stories: Automatic Sprinkler System? No Permit Type: COMMERCIAL RENOVATION M1 CONTRACTOR INFORMATION Contractor Name: Roderick J Waller Fax Number: 772-907-0420 Business Name: Sunrise City Community Housing Development Org ' Inc Email: Rodwallerl@Gmail.Com Business Addr: 3550 Okeechobee Road City / State / Zip: Fort Pierce, FI 34947 REVIEWS AND COMMENTS Review Type Status Reviewed By Date Started Date Completed Date Released FIRE DEPARTMENT REVIEW PENDING Tony Jerger Comment: FRONT COUNTER REVIEW COMPLETE Karen Nielsen 412912016 4129/2016 4/29/2016 Comment: PE REVIEW COMMENTS (2) COMPLETE Joe Cicio 5/19/2016 616/2016 61612016 Comment: PE REVIEW COMMENTS (3) COMPLETE Joe Cicio 61612016 81112016 8/112016 Comment: PE REVIEW COMMENTS (4) COMPLETE Joe Cicio 81112016 911412016 9/14/2016 Comment: PLANS EXAMINER ELECTRIC COMPLETE Walter Pride 6/6/2016 81212016 812/2016 Comment: PLANS EXAMINER MECHANICAL INCOMPLETE Carl Peterson 5126/2016 Comment: PLEASE SHOW THE ASSEMBLY OCCUPANCY MEETING THE REQUIREMENTS FOR VENTILATION IN THE 5/26/2016 FLORIDA MECHANCIAL CODE CHAPTER 4 AS REQUIRED IN SECTION 1009 OF THE FLORIDA EXISTING BUILDING CODE. PLANS EXAMINER PLUMBING COMPLETE Greg Smyth 513112016 8/1/2016 8/1/2016 Comment: t ,>to ",�srrite �ia Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462.2172 Fax:(772)462.6443 REVIEW COMMENTS 3 PLANS EXAMINER REVIEW CQiW f LETE Joe Cicio 5/11/2016 5/1912016 5/1912016 Comment: PLANS EXAMINER REVIEW INCOMPLETE Joe Cicio 9/1412016 Comment: 5TH REVIEW ••• FEE DUE ••• ENGINEER STILL DID NOT ADDRESS THE RESTROOM CLEAR FLOOR AREA AT 9/1412016 THE FIXTURES OR THE DOOR [ SEE FBC ACCESS 404, ADAAG 602, FBC ACCESS 604 ] SHOW THE MANUEVERING CLEARANCES AT THE DOORWAYS TO THE RESTROOMS Comment: •••• 5TH REVIEW •' FEE DUE'..• THE ENGINEER HAS NOW REVERSED THE DOOR SWINGS FOR THE 9/14/2016 RESTROOM DOORS' SWING DOORS CANNOT REDUCE THE REQUIRED MEANS OF EGRESS WIDTH BY MORE THAN 50% IN A SWING • SEE FBC 1005.7.1 ' PLEASE CORRECT ALL PLAN PAGES THAT APPLY Comment: NEED THE BUILDING OWNERS PHONE NUMBER AND E-MAIL ADDRESS ON THE PERMIT APPLICATION 9/16/2016 NEED THE DESIGN PROFESSIONAL INFO ON THE PERMIT APPLICATION • 5TH REVIEW • UN -ANSWERED COMMENT 'FEE DUE 9/16/2016 Comment: SHOW THE REQUIRED RESTROOM REQUIREMENTS PER FBC 1210.2 [ INTERIOR ENVIRONMENT] DETAIL ON PLANS [ NOT ON RE -SUBMITTED PLANS ] ••• STH REVIEW... UN ANSWERED COMMENT _ Comment: ENGINEER QUOTES FBC 1009.11.5 CONSISTENTLY ON PLANS' THIS DOES NOT EXIST IN THE FBC FOR 9/1612016 THE HANDRAILS' SHOW ALL DETAILS WI ATTACHMENTS FOR THE HANDRAILS ON THE PLANS • MUST MEET ALL LOADS AS SPECIFIED IN FBC 1607.8.1 AND 1607.8.1.1 •••• 5TH REVIEW.... RE -REVIEW FEE DUE 9/1612016 Comment: THE MALTESE CROSS ON A-3 IS IN AN INCORRECT LOCATION AND NOT PER STATUTE 9/1912016 Comment: ENGINEER TO CORRECT NOTE #1 CONSTRUCTION TYPE IS NOT A-3 AND EXISTING OCCUPANCY IS NOT B-2' PLEASE CORRECT PLAN SHEETS 9/19/2016 Comment: ENGINEER HAS QUOTED SBC 405 FOR THE RAMP / WE DO NOT ENFORCE THE STANDARD BUILDING CODE' PLS CORRECT PLANS 9/19/2016 Comment: PLEASE CHECK ALL PLANS UPON RE -SUBMITTAL AND PAY ADDITIONAL REVIEW FEES 9/19/2016 Comment: COMMENTS E-MAILED TO CONTRACTOR AS OF THIS DATE • WILL RE -SEND AFTER MECHANICAL REVIEW = ZONING REVIEW COMPLETE Lydia Galbraith 5/6/2016 5/812016 516/2016 Comment: or `� RECEIVED E® OO DEC 2 s 2016 Planning S Development Services REVIEW COMMENTS Building 8, Code Regulation Division 2300 Virginia Avenue SCANNED FortPierce, FL. 34982 BY Phone:(772)462.2172 Fax:(772)462.6443 St. I-11cje C®Li4 & Page 1 PROPERTY INFORMATION Address: 7131 S U S 1 Owner(s): Port St Lucie Plaza I Llc / Port St Lucie City / State / Zip: Port St Lucie, FI 34952 Plaza li Llc Parcel #: 3422-211-0010-000/6 Jurisdiction: SAINT LUCIE COUNTY Zoning: CG Lot#: Block: APPLICATION INFORMATION Permit Number: 6040597 Stories: Permit Type: COMMERCIAL RENOVATION CONTRACTOR INFORMATION Contractor Name: Roderick J Waller Business Name: Sunrise City Community Housing Development Org Inc Business Addr: 3650 Okeechobee Road City / State / Zip: Fort Pierce, FI 34947 REVIEWS AND COMMENTS Review Type Status Reviewed By FIRE DEPARTMENT REVIEW PENDING Tony Jerger Comment: FRONT COUNTER REVIEW COMPLETE Karen Nielsen Comment: PE REVIEW COMMENTS (2) COMPLETE Joe Cicio Comment: PE REVIEW COMMENTS (3) COMPLETE Joe Cicio Comment: PE REVIEW COMMENTS (4) COMPLETE Joe Cicio Comment: PLANS EXAMINER ELECTRIC COMPLETE Walter Pride Comment: PLANS EXAMINER MECHANICAL COMPLETE Carl Peterson Comment: PLANS EXAMINER PLUMBING COMPLETE Greg Smyth Comment: Automatic Sprinkler System? No Fax Number: 772-907-0420 Email: Rodwallerl@Gmail.Com Date Started Date Completed Date Released 4/2912016 4/29/2016 4129/2016 611912016 6/612016 61612016 6/612016 8/112016 811/2016 811/2016 911412016 9/1412016 61612016 8/212016 81212016 5126/2016 911912016 9/1912016 5131/2016 8/1/2016 8/112016 Planning S, Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462-2172 Fax:(7721462.6443 REVIEW COMMENTS 2 PLANS EXAMINER REVIEW COMPLETE Joe Cicio 5111/2016 5119/2015 5/1s12u15 Comment: PLANS EXAMINER REVIEW INCOMPLETE Joe Cicio 9/1412016 Comment: 5TH REVIEW •" FEE DUE " ENGINEER STILL DID NOT ADDRESS THE RESTROOM CLEAR FLOOR AREA AT 9/14/2016 THE FIXTURES OR THE DOOR [ SEE FBC ACCESS 404, ADAAG 602, FBC ACCESS 6041 SHOW THE MANUEVERING CLEARANCES AT THE DOORWAYS TO THE RESTROOMS Comment: *"*5TH REVIEW "FEE DUE" THE ENGINEER HAS NOW REVERSED THE DOOR SWINGS FOR THE 9/14/2016 RESTROOM DOORS `SWING DOORS CANNOT REDUCE THE REQUIRED MEANS OF EGRESS WIDTH BY MORE THAN 50% IN A SWING `SEE FBC 1005.7.1 `PLEASE CORRECT ALL PLAN PAGES THAT APPLY Comment: NEED THE BUILDING OWNERS PHONE NUMBER AND E-MAIL ADDRESS ON THE PERMIT APPLICATION ` 9/1612016 NEED THE DESIGN PROFESSIONAL INFO ON THE PERMIT APPLICATION `5TH REVIEW `UN -ANSWERED COMMENT `FEE DUE Comment: SHOW THE REQUIRED RESTROOM REQUIREMENTS PER FBC 1210.2 [ INTERIOR ENVIRONMENT ] DETAIL 9/16/2016 ON PLANS [ NOT ON RE -SUBMITTED PLANS ] — 5TH REVIEW "` UN ANSWERED COMMENT Comment: ENGINEER QUOTES FBC 1009.11.5 CONSISTENTLY ON PLANS `THIS DOES NOT EXIST IN THE FBC FOR 9/16/2016 THE HANDRAILS `SHOW ALL DETAILS W1 ATTACHMENTS FOR THE HANDRAILS ON THE PLANS' MUST MEET ALL LOADS AS SPECIFIED IN FBC 1607.8.1 AND 1607.8.1.1 " 5TH REVIEW — RE -REVIEW FEE DUE 9/16/2016 Comment: THE MALTESE CROSS ON A-3 IS IN AN INCORRECT LOCATION AND NOT PER STATUTE Comment: ENGINEER TO CORRECT NOTE #1 CONSTRUCTION TYPE IS NOT A-3 AND EXISTING OCCUPANCY IS NOT B- 9/1912016 2 ` PLEASE CORRECT PLAN SHEETS Comment: ENGINEER HAS QUOTED SBC 405 FOR THE RAMP / WE DO NOT ENFORCE THE STANDARD BUILDING 9/19/2016 CODE `PLS CORRECT PLANS 9/1912016 Comment: PLEASE CHECK ALL PLANS UPON RE -SUBMITTAL AND PAY ADDITIONAL REVIEW FEES 9/19/2016 Comment: COMMENTS E-MAILED TO CONTRACTOR AS OF THIS DATE • WILL RE -SEND AFTER MECHANICAL REVIEW ZONING REVIEW COMPLETE Lydia Galbraith 5/612016 516/2016 , 5/612016 Comment: