HomeMy WebLinkAboutREVIEW COMMENTSc
't
SCANNED
Planning& Development Services REVIEW COMMENTS BY
Building& Code Regulation Division St. Lucie County
Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462-2172 Fax:(772)462.6443
Page 1
Address:
10778 S US 1
Owner(s):
Sandpiper Plaza Inc
City / State / Zip:
Port St Lucie, FI 34952
Parcel #:
3414-501-5002-200/9
Jurisdiction: SAINT LUCIE COUNTY
Zoning:
CG
Lot#: 15 Block: 4
APPLICATION INFORMATION
Permit Number:
1605-0047
Stories: Automatic Sprinkler System? No
Permit Type:
COMMERCIAL RENOVATION
CONTRACTOR INFORMATION
Contractor Name: Jeffrey D Conte Fax Number:
Business Name: P & T Construction Inc
Email: Jeff@Pandtconstruction.Co
Business Addr: 4500 Pga Blvd m _
City / State / Zip: Palm Beach Gardens, FI 33418
Review Type
Status Reviewed By Date Started Date Completed Date Released
DOCUMENTS MISSING
PENDING Lashahna Ingram
5/3/2016 Comment:
NEEDS NOC
5/3/2016 Comment:
PROVIDE NEW SIGNATURE PAGE WITH 2 NOTARIZED SIGNATURES
5/6/2016 Comment:
ELECTRICAL AND PLUMBING SUB AGREEMENT.
FIRE DEPARTMENT REVIEW
PENDING - Tony Jerger
Comment:
FRONT COUNTER REVIEW
COMPLETE Lashahna Ingram 5/3/2016 613/2016 513/2016
Comment:
PLANS EXAMINER ELECTRIC
INCOMPLETE Walter Pride 511712016
5/17/2016 Comment:
EXIT AND E.M.COMBO LIGHTS,NEEDED ARE ALL EXITS,WALT PRIDE SR.
PLANS EXAMINER MECHANICAL
INCOMPLETE Carl Peterson 6/13/2016
Comment:
PLEASE SHOW THE ASSEMBLY OCCUPANCY MEETING THE REQUIREMENTS FOR VENTILATION IN THE
5/1312016
FLORIDA MECHANCIAL CODE CHAPTER 4 AS REQUIRED IN SECTION 1009 OF THE FLORIDA EXISTING
BUILDING CODE.
PLANS EXAMINER PLUMBING
INCOMPLETE Greg Smyth 511112016
5/1112016 Comment:
PLEASE SHOW HOT WATER TO ALL SINKS PER SECTION607.1 OF THE FLORIDA PLUMBING CODE 2014.
5/11/2016 Comment:
CANNOT COMPLETE PLUMBING REVIEW UNTIL CORRECT OCCUPANT LOAD IS DONE PER SECTION 1004
OF THE FLORIDA BUD CODE 2014.
.JL'• �f�JC�lti UPNatZry
Planning & Development Services
Building & Code. Regulation Division
2300 Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772K62.2172 Fax:(772)462.6443
REVIEW COMMENTS
PLANS EXAMINER REVIEW INCOMPLETE Joe Cicio 6/11/2016
Comment:
BEING A LEVEL 2 ALTERATION THIS IS ALSO CHANGE OF OCCUPANCY AND MUST BE DESIGNED TO
5/11/2016
FBC EX. BLDG 506 AND THE PROVISIONS OF CHAPTER 10' PLEASE NOTE ALL APPLICABLE CODES PLANS
ARE DESIGNED TO ON PLANS STARTING WITH THE 2014 FLORIDA BUILDING CODE 5TH EDITION, 2014 FPC,
2014 FMC, 2012 ACCESSIBILITY, 2014 EBC, 2011 NEC, 2014 FFPC,
5/1112016 Comment:
DESIGN PROFESSIONAL TO NOTE THE CONSTRUCTION TYPE ON PLANS' FBC CHAPTER 6 SECTION 602'
IS THE TENANT AREA SPRINKLED OR UN -SPRINKLED
Comment:
THE AREA SO FOOTAGE IS TO HIGH PER THE PLAN DIMENSIONS AND THE TOTAL OF THE OCCUPANT
5/11/2016
LOAD SQUARE FOOTAGES MUST EQUAL UP TO THE TOTAL S.F.' CANNOT USE AN OCCUPANT LOAD OF 15
FROM TABLE 1004.1.2 OR SHOW ALL TABLES AND CHAIRS ON PLANS
5/11/2016 Comment:
IDENTIFY THE PSI OF THE CONCRETE AND THE TERMITE SPRAY ON PLANS FOR THE SLAB REPAIR AREA
Comment:
SHOW THE TESTING CRITERIA ON THE PLANS FOR THE 2 HOUR RATED PARTITIONS' FBC 703.2'
5/11/2016
REMOVE THE OPTIONAL CONTEGO COATING FROM THE PLANS AS OPTION' PLEASE SELECT ONE OR
THE OTHER METHODS ,
5/1112016 Comment:
SHOW THE REQUIRED PANIC HARDWARE DETAILS ON PLANS PER FBC 1008.1.10
5/11/2016 Comment:
FBC 1014.2 NOTE 4 PROHIBITS EGRESS THROUGH KITCHEN AND STORAGE SPACES IN ASSEMBLY AREAS
Comment:
PLANS ARE NOT CORRECTLY SHOWING THE HEIGHT OF THE ALTAR' SITTING AREA AND ALTAR BOTH AT
10.0' CEILING HEIGHT' SHOW A SIDE PROFILE OF THE STAIRWAY TO THE ALTAR' SHOW THE REQUIRED
5/11/2016
HANDRAILS PER FBC 1012 AND 1012.1 ' HANDRAILS ARE REQUIRED TO BE ON EACH SIDE OF THE
STAIRWAY FBC 1009.15 AND CAPABLE OF WITHSTANDING THE LOADS AS STATED IN 1607.8' SHOW ALL
ATTACHMENTS
5/1112016 Comment:
DESIGN PROFESSIONAL TO INCLUDE A WALL, CEILING AND FLOOR FINISH TABLE ON PLANS PER FBC
TABLE 803.9' IDENTIFY THE FLOOR AND CEILING FINISHES ON PLANS PER FBC 804 AND 808
Comment:
SHOW ALL LOADS AND DETAILS ON PLANS PER FBC TABLE 1607.1 FOR THE RAISED PLATFORM, STEP
5/11/2016
ETC " SHOW THE REQUIRED ACCESSIBILITY RAMP DETAILS PER FBC ACCESSIBILITY 405 W/ HANDRAILS [
4051 UP TO THE RAISED PLATFORM ON PLANS' SHOW ALL DETAILS AND RAMP ELEVATIONS ON PLANS
5/11/2016 Comment:
SHOW THE ACCESSIBLE ROUTE FROM THE PARKING AREA INTO THE FACILITY ON PLANS
5/1112016 Comment:
SHOW THE RESTROOM DETAILS ON PLANS PER FBC 1210 • SEE 1210.2.2
5/16/2016 Comment:
SHOW THE CLEAR FLOOR AREAS ON PLANS FOR THE COMMODE AREAS IN BOTH RESTROOMS FBC
ACCESSIBILITY 604
6/1712016 Comment:
COMMENTS E-MAILED AS OF THIS DATE TO OWNER AND CONTRACTOR
ZONING REVIEW
COMPLETE Lydia Galbraith 5/6/2016 5/612016 5/612016
Comment:
4
Planning 8, Development Services
Building 8, Code Reguladan Division
2300 Virginia Avenue
Fort Pierce, FL 34982.
Phone:(772)462.2172 Fax:(772)462-6443
PROPERTY INFORMATION
Address:
10778 S U S 1
City / State / Zip:
Port St Lucie, FI 34952
Parcel#:
3414-501-5002-200/9
Zoning:
CG
APPLICATION INFORMATION
REVIEW COMMENTS
SCANNED
BY
St. Lucie County
Owneris):
Sandpiper Plaza Inc
Jurisdiction: SAINT LUCIE COUNTY
Lot#: 15 Block: 4
Page 1
Permit Number:
1605-0047 Stories: Automatic Sprinkler System? No
Permit Type:
COMMERCIAL RENOVATION
CONTRACTOR INFORMATION
Contractor Name:
Jeffrey D Conte Fax Number:
Business Name:.
P & T Construction Inc
Email:
Business Addr:
Jeff@Pandtoonstruction.Co
4500 Pga Blvd
City / State / Zip:
Palm Beach Gardens, FI 33418
REVIEWS AND COMMENTS
Review Type
Status Reviewed By Date Started Date Completed Date Released
DOCUMENTS MISSING
PENDING Lashahna Ingram
5/3/2016
Comment: NEEDS NOC
5/6/2016
Comment: ELECTRICAL AND PLUMBING SUB AGREEMENT.
FIRE DEPARTMENT REVIEW PENDING Tony Jerger
Comment:
FRONT COUNTER REVIEW COMPLETE Lashahna Ingram 51312016 6/312016 51312016
Comment:
PE REVIEW COMMENTS (2) INCOMPLETE Joe Ciclo 7/512016
Comment: DESIGN PROFESSIONAL TO NOTE THE CONSTRUCTION TYPE ON PLANS ` FBC CHAPTER 6 SECTION 602 `
5/11/2016
IS THE TENANT AREA SPRINKLED OR UN -SPRINKLED — SECOND REVIEW/ CONSTRUCTION TYPE NOT
NOTED ON REVISED PLANS "`
Comment: PLANS ARE NOT CORRECTLY SHOWING THE HEIGHT OF THE ALTAR' SITTING AREA AND ALTAR BOTH AT
10.0' CEILING HEIGHT • SHOW A SIDE PROFILE OF THE STAIRWAY TO THE ALTAR `SHOW THE REQUIRED
6/1112016
HANDRAILS PER FBC 1012 AND 1012.1 • HANDRAILS ARE REQUIRED TO BE ON EACH SIDE OF THE
STAIRWAY FBC 1009.15 AND CAPABLE OF WITHSTANDING THE LOADS AS STATED IN 1607.8 ` SHOW ALL
ATTACHMENTS — SECOND REVIEW / SHOW AND DETAIL THE REQUIRED HANDRAILS ON THE STAIR AREA
PER FBC 1009.15 AND COMPLY WITH FBC 1012 CRITERIA
Comment: SHOW ALL LOADS AND DETAILS ON PLANS PER FBC TABLE 1607.1 FOR THE RAISED PLATFORM, STEP
ETC "SHOW THE REQUIRED ACCESSIBILITY RAMP DETAILS PER FBC ACCESSIBILITY 405 W/ HANDRAILS I
5/11/2016
4051 UP TO THE RAISED PLATFORM ON PLANS - SHOW ALL DETAILS AND RAMP ELEVATIONS ON PLANS
"` SECOND REVIEW— RAMPS CHANGING DIRECTION MUST CONTAIN A LANDING AT MIN: 60" X 60" "SEE
FBC ACCESS. FIGURE 405.7 ( NOTE B ] OR ADAAG 4.8.4"
Comment: SHOW THE CLEAR FLOOR AREAS ON PLANS FOR THE COMMODE AREAS IN BOTH RESTROOMS FBC
5/16/2016
ACCESSIBILITY 604 — DID NOT SHOW ON PLANS "` DETAIL IN ACCORDANCE WITH FBC ACCESS. 604.8.2
AND ADAAG 4.22 AND 4.23
. of
Planning& Development Services
Building &Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982.
Phone:V72)462.2172 Fax:(772)462.6443
REVIEW COMMENTS
2
7/5/2016 Comment:
•••• OCCUPANCY CLASSIFICATION "" KIDS CLASSROOM MUST BE CALCULATED AS 7 NET AND IS A PART
OF THE ASSEMBLY AREA • SEE FBC 305.1.1
7/1312016 Comment:
SECOND REVIEW COMMENTS E-MAILED AS OF THIS DATE . RE -REVIEW FEES DUE
PLANS EXAMINER ELECTRIC
COMPLETE Walter Pride 5/17/2016 7112/2016 7112/2016
Comment:
PLANS EXAMINER MECHANICAL
INCOMPLETE Carl Peterson 5113/2016
Comment:
PLEASE SHOW THE ASSEMBLY OCCUPANCY MEETING THE REQUIREMENTS FOR VENTILATION IN THE
5/13/2016
FLORIDA MECHANCIAL CODE CHAPTER 4 AS REQUIRED IN SECTION 1009 OF THE FLORIDA EXISTING
BUILDING CODE.
PLANS EXAMINER PLUMBING
INCOMPLETE Greg Smyth 5111/2016
511112016 Comment:
CANNOT COMPLETE PLUMBING REVIEW UNTIL CORRECT OCCUPANT LOAD IS DONE PER SECTION 1004
OF THE FLORIDA BLD CODE 2014. -
7/6/2016 Comment:
STILL NEED CORRECT OCCUPANT LOAD.
PLANS EXAMINER REVIEW
COMPLETE Joe Cicio 5/11/2016 7/612016 715/2016
Comment:
ZONING REVIEW COMPLETE
Comment:
Lydia Galbraith 51612016
516/2016 516/2016