Loading...
HomeMy WebLinkAboutPRODUCT APPROVALFlorida Building Code Online Page 1 of 3 ` g it r •� �' '}t BTU �k -`�`g :3 ?2 Tr d�: q Farda Demrtrnent4 KIS Home I Lop In i User ReglstraUoo Hot Topls j submit Sumhartie I Stats&Facts i PubIIWDons ; FK Stan j eCIS Site Map r Unks I Search Businesj x Product Approval w) Professi nal USER: Pubpc Daer Regulation Pmdud Anomval Menu > Pmdud or Application Search > Aooll .� Uonn List > Application Detail FL # FL5891-RS Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method L Therma-Tru Corporation 118 Industrial Drive Edgerton, OH 43517 (419) 298-1740 rickw@rwbldgconsultants.com Rick Wright rickw@rwbldgconsultants.com Exterior Doors Swinging Exterior Door Assemblies R .a�a• B�t1 k? ,�'.a SCANNED BY St. Lucie County Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 121 Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Lyndon Schmidt, P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute r. Quality Assurance Contract Expiration Dale 12/31/2018 Validated By Ryan 1. King, P.E. 0 Validation Checklist - Hardcopy Received Certificate of Independence FL5891 RS COI Certificate fI deoendence odf Referenced Standard and Year (of Standard) Standard Year SSTD 12 1999 TAS 202 1994 Equivalence of Product Standards Certified By A Sections from the Code Product Approval Method Method 1 Option D http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquw6mPIZhp`/o2... 6/23/2016 + Florida Building Code Online Page 2 of 3 Date Submitted 06/13/2015 Date Validated 06/28/2015 Date Pending FBC Approval 07/05/2015 Date Approved 08/18/2015 Summary of Produ cts FL # Model, Number or Name Description 5891.1 a. "FiberClassic" 6'8 "Impact" Opaque Fiberglass Single Door (X) Inswing or Outswing Configuration Limits of Use Installation Instructions Approved for use in HVHZ: No FL5891 R5 II Inst 5891.1.odf Approved for use outside HVHZ: Yes Verified By: Lyndon Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 5891.1 for Design Pressure Ratings by FL5891 R5 AE Eval 5891.1.odf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. (For FiberClassic doors, this product approval requires the use of "I" part numbers for these doors, which have been stained or painted within six months of installation.) 5891.2 b. "SmoothStar" 6'8 "Impact" Opaque Fiberglass Single Door (X) Inswing or Outswing Configuration Limits of Use Installation Instructions Approved for use in HVHZ: No FL5891 R5 II Inst 5891 2 odf Approved for use outside HVHZ: Yes Verified By: Lyndon Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 5891.2 for Design Pressure Ratings by FL5891 R5 AE Eval 5891 2 odf specific Model and for any otheradditional use limitations Created by Independent Third Party: Yes and installation instructions. (For SmoothStar doors, this product approval requires the use of "J" part numbers for these doors, which have been stained or painted within six months of Installation.) 5891.3 c. "ClassicCrak" 6'8 "Impact" Opaque Fiberglass Single Door (X) Inswing or Outswing Configuration Limits of Use Installation Instructions Approved for use in HVHZ: No FL5891 R5 II Inst 5891 3 odf Approved for use outside HVHZ: Yes Verified By: Lyndon Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 5891.3 for Design Pressure Ratings by FL5891 R5 AE Eval 5891 3 odf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. 5891.4 d. "FiberClassic" "Impact" Opaque Fiberglass Single Door (X) Inswing or 0 Outswing Configuration Limits of Use Installation Instructions Approved for use in HVHZ: No FL5891 R5 II Inst 5891.4.odf Approved for use outside HVHZ: Yes Verified By: Lyndon Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 5891.4 for Design Pressure Ratings by FL5891 RS AE Eval 5891 4.odf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. (For FiberClassic doors, this product approval requires the use of "J" part numbers for these doors, which have been stained or painted within six months of installation.) 5891.5 e. "SmoothStar" 8'0 "Impact" Opaque Fiberglass Single Door (X) Inswing or Outswing Configuration Limits of Use Installation Instructions Approved for use in HVHZ: No FL5891 R5 II Inst 5891 5.odf Approved for use outside HVHZ: Yes Verified By: Lyndon Schmidt, P.E. 43409 Impact Resistant: Yes Design Pressure: N/A Created by Independent Third Party: Yes Evaluation Reports Other: See INST 5891.5 for Design Pressure Ratings by specific Model and for any other additional use limitations and installation instructions. (For SmoothStar doors, this FL5891 R5 AE Eval 5891 5 odf Created by Independent Third Party: Yes product approval requires the use of "J" part numbers for these doors, which have been stained or painted within six months of installation.) 5891.6 f. "ClassicCraft" http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquw6mPIZhp%2... 6/23/2016 Florida Building Code Online Page 3 of 3 8'0 "Impact" Opaque Fiberglass Single Door (X) Inswing or Outswing Configuration Limits of Use Installation Instructions Approved for use in HVHZ: No FL5891 R5 II Inst 5891.6.odf Approved for use outside HVHZ: Yes Verified By: Lyndon Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 5891.6 for Design Pressure Ratings by FL5891 R5 AE Eval 5891.6.odf specific Model and for any other additional use limitations Created by Independent Third Party: Yes and installation instructions. Back Nect Contact U :: 1940 North Monme street Tallahassee FL 32399 Phone: 850-4874824 The some of Florida Is an "EM employer. Copyright 2007-2013 State of Florida.:: Privacv Statement :: Accessibility statement :: Refund statement under Florida law, email addresses are publlc records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contain 850.07.1395.'Pursuant to Section 455.275(1), Florida statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if May have one. The emaile provided may be used for official communication with the licensee. However email addresses are public record. It you do not wish to Supply a personal address, please provide me Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click hyee . product Approval Accepts: http://www.floridabuilding.orglprlpr_app_dtl.aspx?param=wGEVXQwtDquw6mPIZhp%2... 6/23/2016 NERMANTRU® THERMA TRU DOORS 1 1 ES INDUSTRIAL DR., EDGERTON. OH 43517 37X 6F8FF "FIBER CLASSIC" FIBERGLASS SINGLE DOOR INSWING / OIITSWING 'rimmcr' GENERAL NOTES 1. This product has been evaluated and is in compliance with the Sth EcIfion (2014) Florida Building Code (FBC) structural requirements excluding the °Hlgh Velocity Hurricane Zone" (HVHZ). 2. Product anchors shoo be as Fisted and spaced as shown on details. Anchor embedment to base material shall bebeyond wall dressing or stucco. 3. When used in areas requiring wind bome debris protection this product compiles With Section 1609.1.2 of the FBC and does not require an Impact resistant covering. This product meets missile level "D° and excludes Wind Zone 4 as defined in ASTM El996 and Section 1609.1.2.2 of the FBC. 4. For 2x stud framing construction, anchoring of these units shall be the some as that shown for 2x buck masonry construction. 5. Site condtions that deviate from the details of this drav4ng require fudherengineering analysis by a licensed engineer orregislered arctutect. TABLE OF CONTEMS SHEET# DESCRIPTION I Typical elevaliom, design F -e —s S general noles 2 DoorponeldetoBs 3 Ha¢ontal am sections 4 VerlkalcrosssecRom 5 Buck and frame anchoring- 2)(buck masonry constrmction 6 From anchoring- Ix buck masonry construction 7 Bit of Mateuals S, Components Jw 37.57 MAX. O.A, FRAME WIDTH*"S�^w PANfl WIDTH ii�,,4 ...*...• ```� m ' TTllr1r1111 zomg ® ® rkN�mr��i m`n `n� 5V` a UZ 0 � n n m U a 0 50 0 -X�,;,DYERAEY" bESIGtJ PAESSIIRE iI"5f1?. _SWING ' ERAKiE es.::• _ ..,UJMENSIDNr; .:FOSMYEa" NEG'AYNF" INSWING 37.59°x82.19" +67.0 •67.0 OUTSWING 37A9'xB0.69" +67.0 -67.0 FL-5B91.1 0.1ame The TN PER ENMD da PeoduG/ypmnls1F45891NnriygCurtmgR-SB91Arp 21 $ o ®w® El 0 e a �083 a fr a —1„sr 0 7 3 1 4 A A Z A A n € T 9 THERMA—TRU RSERGfASS DOOR Lyndon P. 5ohmldE Rpgpr•.' P.E. Ne. 434Da11µ11�E GDBUILDING CONSUITNIR, �NC. uu P.O. Bo: Yap, VaU1w. Fti W585 PNoae N..: 813.659.9187 R A55EMBLY: DOOR PANEL DETAILS PBPE CA No. 9813 4 4 ........ E 1 .�y R e 0 J ® ® *1OR 4 INTERZ * $an ''''7j1111 *Ipi II "„``` 21 �yy Z N p Ess$ z m cw �N w �a`a� 17 $`• 2 EXTERwE - z� � "^—�'v�i 4 w� o0 I-1/4'MIN. 0 FMB. IIYP.I K 3 C o 4 %� NORIZONZAL CROSS SECTION L o Ga C 3 Shown w/7X su4Cuck u o �yim v 27 50 9 10 INTERIOR INTERIOR 10 Y 0 wy i WCp O . Nry FF K 7 EXTERIOR EXTERIOR E 5D 7 B n� 20 B " 0 K -z o K 20 an: a 23 08 1-1/f MIN. B N.T.S B . mvc. ec AL m' EMB. (TYP.) E C.. m: LF5 3 %11 HORIZONTAL CROSS SEC77ON MIN. D Men: d HORIZONTAL CROSS SECTION . EMB. DFL-5891. ntwinYP•1 1 v 3 Igconfgumtion 3. Iruwingconfigumfion n s a 3 ., 7 n Maonb\The na TIV PE9MANUJIVIorlda PmauC al O T m on Ln m � 0 Q A A A 0 � °n O^ s� mA -n 0o P Q so Q C N = A 8 N A m V ' n N A nn A 2 2 a v I- NUN EMB. jTYPJ I 0 no - A )o P A p a w 29 A A rQQn RR 9 R�R 3 n n 8 Pe n P.... Bn gQ oO i Q n H A n A Co Q A Z m V m p n 1-1/4•MIN. DAB. (TYP.( �� V.•'TLCil1�••.,1• ' No.49/09• i QI I PRODUCT: 9xwwnt png .a W. i �OOGDP 1: �� •••.Rapti THERM-TRU Lyndon F. Schmidt r+' FIBERGLASS DOOR P.E. No. 4J409 Q y G 2 BUILDING LON3ULTANT511INC.11T1` 1 2B IS UPDATE TO 5TH E0. 2014 FeL LFS PART OR ASSEMBLY: I� in p 1 R P.O. Boe 23D, Va1Hca, FL JS39S 6 I1 12 REVISED TO 2010 FSC JK DATE BY m NO CROSS SEC 0N5 Ph No.: 8I3.659.9197 REVISIONS Mono CA No. 9913 it 4 T- d MASONRY TYP. HEAD & OPENING JAMBS L 2X BUCK, OU BUCKANCHORING STRIKEJAMB CONCRETE ANCHOR NOTES I. Concrete anchorlocaffons at the comm maybe adjusted tomolntaln the min. edge dstuace to morforloints. 2. Concmfeonchoriocatiomnoted osMAX. ONCENTER" must ba adjusted to maintain the min. edge distance to mortorJoInts. additional concrete anchors may be required to ensure the "MAX. ON CENTER' dimension am not exceeded. 3. Concrete anchor table: 499.:-i IM40M ENWT TO MASONRY ; ' IVAMACENT.- --'EDGE ANCHOR;:—: ITW TAPCON' 1/4" ELCO 4 ULTRACON 1/4" 1.1/'r 1. 4" WOOD SCREW INSTALLATION NOTES Maintain a minfmum 519'ad.. distance. I- end elicinncn x I• n cmn—lnn MASONRY OPENING FRAME P HEAD AAMBS & rcj5 —4 FRAME ANCHORING MMordy 2X buck Construction HINGE DETAIL HINGEJAMB Writ A DEADBOLT DETAIL ZM: 4 23 08 L N.T.S. M AL LFS FL-5891.1 .7 5 � 7 6" MASONRY OPENING FRAME HEAD 8 JAMBS lXBUCKS STRIKEJAMA FRAMEANCHORING Mascavy IX buck construction CONCRETE ANCHOR NOTES: I Connate anchor locations of the comers may be adjusted to maintain the min. edge distance to morforfolats. Z Corimle anchor locations noted as "MAX. ON CENTER" must be adjusted to maintain the min. edge distance to mortarjoInts, additional concrete anchors may be required to ensure the'MAX. ON CENTER" dimension are not exceeded. 3. Conaelas anchor table: - ANCHOR ; -ANCHOk 1, 'MIN. 1 . :: AK.CIWANCRI INXWARANCt �0 9�! wv AmAcEm law TAPCON* 1/,r 1-1/4" I 2" 4- I ITW , TAPCON® 3/16, 1 1-114' 3. 1 WOOD SCREW INSTALLATION NOTES. I and distance. fi, I " o.c. sDacina Maintain a minimum 518" edcras distance- HINGE JAME h la HINGE DETAR lima 'TFF Roz c 4123108 , N.T.S. AL i LFS .No W6 FL-5891.1 ' c 7 -6- wzl. BILL OF MATERIALS ITEM DESCRIPTION MATERIAL A 1XBUCKSG>=0.55 WOOD B 2X BUCK SG>=0.55 WOOD C MAX.1/4"SHIMSPACE WOOD D 14"X2-34"PFH ELCO OR RW CONCRETE SCREW STEEL E MASONRY - 3,000 PSI MIN. CONCRETE CONFORMING TO ACI 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE G 3/16"X3-1/4"PFH IIW CONCRETE SCREW STEEL H 1/4"x3-1/4°PFH IIW CONCRETE SCREW STEEL J 1/4"X 33/4"PFH ITW CONCRETE SCREW STEEL K #8X2-1/Z'PFH WOOD SCREW STEEL L #10 X 2" PFH WOOD SCREW STEEL 7 SHORT REACH COMPRESSION WEATHERSTRIP FOAM 8 LONG REACH COMPRESSION WEATHERSTRIP FOAM 9 4"X4"HINGE.097'THK. STEEL 10 #10X 3/4" PFH WOOD SCREW STEEL 17 KWIKSET SIGNATURE SERIES PASSAGE LOCK STEEL 18 LOW PROFILE OUISWING BUMP FACE THRESHOLD ALUM./WOOD 19 HEADER JAMB PINE, S.G>=0.42 WOOD 20 SIDE JAMB PINE, S.G.>=0.42 WOOD 21 KWIKSET SIGNATURE SERIES 780 DEADBOLT STEEL 27 LATCH STRIKE PLATE STEEL 28 DEADBOLT PLATE STEEL 32 DOOR BOTTOM SWEEP PVC 33 SELF ADJUSTING INSWING SADDLE THRESHOLD ALUM.COMP. 50 FIBERGLASS DOOR PANEL - FIBER CLASSIC ' 51 FC DOOR SKIN .070" MIN. THK. FIBERGLASS BY THERMA-TRU WITH YIELD STRENGTH Fy (MIN.) = 6.000 PSI SMC 52 TOP RAIL COMPOSITE 53 LATCH STILE LVL WOOD 54 HINGE STILE WOOD 55 BOTTOM RAIL COMPOSITE 56 POLYURETHANE FOAM CORE-1.9 LBS. DENSITY FOAM 57 1 LOCK BLOCK REINFORCEMENT I WOOD NOTE: WOOD/LVL COMPONENTS [PINE, SG>= 0.421 �— 4S6" ry �j c � 2.36" 8S--{ I 19 20 NEAD B SIDE Jamb F-2.20' T I 4.62" —� I TB LOW PROFILE OUISWING BUMP FACE 5.75 — L ,, n r � SELF ADJUSTING SADDLE 7NRESHOID er LFS nrw xo: ' FL-5B91.1 7 a 7