PLAN REVIEW FORM
SCANNf;®
4m t
S160 N.W. Milner Drive
BY
1 e �,
x;
Port Saint Lucie, FL 34983
Telephone:772-621-3322
St. Lucie County
ti
x
�9F01S�'
Fax: 772-621-3604
Web Address: www.slcfd.com
Building Dept. SLC FMO Permit B-16-153
Project Name Cross Fit Gym BLDG Permit# 1605-0182
Address 2901 North US 1 City Ft Pierce
Contractor St Lucie Structures
Address 4888 North Kings Hwy #225 City Ft Pierce
State FL Zip 34951 Telephone (772)461-1775
Architect/Engineer Cook &Manard Telephone (772)460-7751
Occupancy Type Assembly Construction Type VB Square Feet 12,000
Occupant Load 240perplans Number of Stories Access Box Required Access Key Switch
AFS Permit F
FA Permit FFP Permit
General Notes
1. An electronic copy of the construction documents submitted on a CD Is required. The file format shall be.pdf only.
2. All revisions, including the electronic copy must be received prior to permitting.
3. The Fire Marshal requires 24 hour notice on all inspections.
4. The respective Building Department shall schedule all final inspections through the Fire Marshal's Office.
5. Failed inspections require payment of fee priorto rescheduling of further inspections.
6. Penetrations through rated assemblies shall be of the proper UL design. Design criteria shall be submitted with the construction plans.
7. Fire alarm panels shall be located Indoors within air conditioned space.
e. Plans and construction are subject to corrections in the field to maintain code compliance.
9. Automatic fan shutdown is required for HVAC system/s that exceed 2,000 cfm design capacity.
10. The Installation or Alteration of Fire Sprinklers, Fire Alarms, and Fixed Fire Protection Systems require a separate review and permit.
THE FLORIDA FIRE PREVENTION CODE, 2012 EDITION IS CURRENTLY ENFORCED.
BUILDINGS WITH LIGHT-FRAMETRUSS-TYPE CONSTRUCTION SHALL BE MARKED WITH APPROVED FIREFIGHTER SAFETY
WARNING SIGNS IN ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODES 69A-3.012 AND 69A-60.0081 PRIOR TO RECEIVING
A CERTIFICATE OF OCCUPANCY.
bee aenerai (votes Hoove anci
1. Automatic fan shutdown is required for HVAC system/s that exceed 2,000 cfm design capacity. Provide a remote test and
inspect appliance equipped with an audible/visual indicator for each HVAC duct smoke detector.
2. Panic hardware is required on all exits doors.
3. Portable fire extinguishers from a licensed contractor are required.
4. Field inspections may require additional revisions.
Page 1❑ of -1 Reviewed by Tony Jergef Date 06-14-16
�T.1LUCI E COUNTY ]FIREDISTRICT
J���i�OUNT`�lo
FIRE PREVENTION BUREAU �.
Office of the Fire Marshal ;
X k• Yy
DIS�����.
FIRE WALLS
SMOKE TEST
SPRINKLERS ABOVEGROUND HYDRO
FIXED FIRE SUPPRESSION SYSTEMS
BUILDING FINAL
Telephone: (772) 621-3322
Fax: (772) 621-3604
PENETRATIONS
SPRINKLERS UNDERGROUND HYDRO
FINAL
FIRE ALARM FINAL
MISC. INSPECTIONS
"Our Family Serving Yours„
5160 N.W.Milner Drive, Port t St. Lucie, Florida 34��3-33��
Telephone: (772) 621-3400 o II ax: (772) 621-3500
evsvev s— le�oni