HomeMy WebLinkAboutPLAN REVIEW FORMSAINT LUCIE COUNTY FIRE DISTRICT ��6�Uk11'�., PLAN REVIEW FORM SCANNf;® 4m t S160 N.W. Milner Drive BY 1 e �, x; Port Saint Lucie, FL 34983 Telephone:772-621-3322 St. Lucie County ti x �9F01S�' Fax: 772-621-3604 Web Address: www.slcfd.com Building Dept. SLC FMO Permit B-16-153 Project Name Cross Fit Gym BLDG Permit# 1605-0182 Address 2901 North US 1 City Ft Pierce Contractor St Lucie Structures Address 4888 North Kings Hwy #225 City Ft Pierce State FL Zip 34951 Telephone (772)461-1775 Architect/Engineer Cook &Manard Telephone (772)460-7751 Occupancy Type Assembly Construction Type VB Square Feet 12,000 Occupant Load 240perplans Number of Stories Access Box Required Access Key Switch AFS Permit F FA Permit FFP Permit General Notes 1. An electronic copy of the construction documents submitted on a CD Is required. The file format shall be.pdf only. 2. All revisions, including the electronic copy must be received prior to permitting. 3. The Fire Marshal requires 24 hour notice on all inspections. 4. The respective Building Department shall schedule all final inspections through the Fire Marshal's Office. 5. Failed inspections require payment of fee priorto rescheduling of further inspections. 6. Penetrations through rated assemblies shall be of the proper UL design. Design criteria shall be submitted with the construction plans. 7. Fire alarm panels shall be located Indoors within air conditioned space. e. Plans and construction are subject to corrections in the field to maintain code compliance. 9. Automatic fan shutdown is required for HVAC system/s that exceed 2,000 cfm design capacity. 10. The Installation or Alteration of Fire Sprinklers, Fire Alarms, and Fixed Fire Protection Systems require a separate review and permit. THE FLORIDA FIRE PREVENTION CODE, 2012 EDITION IS CURRENTLY ENFORCED. BUILDINGS WITH LIGHT-FRAMETRUSS-TYPE CONSTRUCTION SHALL BE MARKED WITH APPROVED FIREFIGHTER SAFETY WARNING SIGNS IN ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODES 69A-3.012 AND 69A-60.0081 PRIOR TO RECEIVING A CERTIFICATE OF OCCUPANCY. bee aenerai (votes Hoove anci 1. Automatic fan shutdown is required for HVAC system/s that exceed 2,000 cfm design capacity. Provide a remote test and inspect appliance equipped with an audible/visual indicator for each HVAC duct smoke detector. 2. Panic hardware is required on all exits doors. 3. Portable fire extinguishers from a licensed contractor are required. 4. Field inspections may require additional revisions. Page 1❑ of -1 Reviewed by Tony Jergef Date 06-14-16 �T.1LUCI E COUNTY ]FIREDISTRICT J���i�OUNT`�lo FIRE PREVENTION BUREAU �. Office of the Fire Marshal ; X k• Yy DIS�����. FIRE WALLS SMOKE TEST SPRINKLERS ABOVEGROUND HYDRO FIXED FIRE SUPPRESSION SYSTEMS BUILDING FINAL Telephone: (772) 621-3322 Fax: (772) 621-3604 PENETRATIONS SPRINKLERS UNDERGROUND HYDRO FINAL FIRE ALARM FINAL MISC. INSPECTIONS "Our Family Serving Yours„ 5160 N.W.Milner Drive, Port t St. Lucie, Florida 34��3-33�� Telephone: (772) 621-3400 o II ax: (772) 621-3500 evsvev s— le�oni