Loading...
HomeMy WebLinkAboutMISC EMAILMission: To protect promote & improve the health of all people in Florida through integrated state, county & community efforts. Vision: To be the Healthiest State in the Nation Rick Scott Governor Celeste Philip, MD, MPH Interim State Surgeon General May 2, 2016 Michael Salerno, General Manager SCANNED Harbour Ridge Yacht & Country Club BY 12600 Harbour Ridge Blvd. LUCI@ County Palm City, FL St. 34990 RE: Review of Application for Public Swimming Pool Operating Permit Harbour Ridge Lifestyle Center - Pool (DOH File # 56-60-1677363) 13400 NW Gilson Road, Palm City, FL 33490 Dear Mr. Salerno, On April 25, 2016 the Florida Department of Health (Department) acknowledged receipt of the operating permit application for the swimming pool with the receipt of an application and plans. Currently the swimming pool application is incomplete pending receipt of the information requested in the acknowledgement letter and construction. Since receiving the application the Department has reviewed the plans for both the swimming pool and the spa pool provided noting issues that will need to be resolved prior to issuance of the operating permits. These issues include the following: Item # Description 1 Pool shell free of designs which interfere with detection of human(s) in distress, algae, sediment, or other objects in pool. (Note: Sheet 2 of 5 shows a highlighted area on the top step. The area does not appear to be defined. Is this a mosaic or logo?) 2 Lap lanes and targets on non -competition pools to meet code. (Note: The plans have a note that the lap lane is to be 4 foot from the wall. However, the plans show the lap lane at only 3 foot based on the scale provided.) 3 All pool walls (except steps and spa coves) have minimum 15' clearance perpendicular to a tangent to the wall. (Interior step protrusion does not exceed 6') / Benches do not protrude into the 15' clearance requirement. (Note: This issue is associated with the distance between the wall and the bench seat in the stair area. The distance from the pool edge (top of stairs) to the bench seat appears to be less than 15 feet based on the scale provided.) 4 Comers shall be a minimum 90 degree angle. (Note: This is in the area of the stairs.) 5 Symmetrical pool designs with deep point at center have dual markings indicating depth at wall and at the deep point, followed by FEET or INCHES. (Note: Not indicated on the drawings.) 6 Handrails shall extend between 28" and 40" above the step or deck. (Note. Sheet 3 of 5 specifies the minimum height but not the maximum height for the stairs.) 7 Ladder treads are slip -resistant and the clearance between the ladder and pool wall is 3 to 6". Ladder bottom braces have end caps. Top rung is at or below water level on open gutter pools and max. 12" below deck/curb top on all others. (Note: Sheet 2 of 5 shows the tread detail with an open gutter.) 8 Structures located inside pool perimeter are additional part of the recirculation system and are not located less than 15' from any pool wall and are not located within the diving bowl area. (Note: Issue deals with the interior wall within the pool and Item 3. Will the wall be above the water level?) Florida Department of Health, Palm Beach County Office or Department Address 800 Clematis Street Accredited Health Department West Palm Beach, FL 33401 = Public Health Accreditation Board PHONE 561-8375900• FAX561-8375293 FloridaHealth.gov, Flhealthpaimbeach.org Item # Description 9 A collector tank with an effective capacity of at least 1 minute of the design flow is provided. (Notes: Sheet 5 of 5 shows "A" as the main drain at 6 inches and X" as the therapy main drain at 8 inches but the detail shows "A" on the therapy tank. Sheet 3 of 5 calls for two 6 inch lines. Without detailed elevations and drawdown calculations, sufficient flow into the Therapy Tank cannot be validated by the Department at this time.) 10 Pool is surrounded by min. 48' high fence with self -closing, self -latching, lockable gates opening away from pool. Latch is 54" above bottom of gate or min. 3" below the top of the gate on the pool side. Fence does not allow passage of 4" diameter sphere. Locks, if self-locking, may be 34 — 48 above floor or ground. (Note: Plans show the fence ending at the edge of the water which does not provide a sufficient barrier. The Department has required the fence to extend into the water.) Please note that many of the issues can be resolved during the initial inspections, others may have been addressed in the specifications just not found by the Department and others may require a variance if they cannot be resolved. If you have any questions please feel free to contact me at 561-837-5995. Sincerely, Darrel J. Graziani, P.E., R.S., C.P.O. Regional Engineer Florida Department of Health c: Carl John Peterson, St. Lucie County Building Official (PetersonJ(a,stlucieco.or¢) David Koerner, EPH Director, FDOH St. Lucie County (David.Koemernflhealth.gov) Jamie Curtis, Engineers of Record (imniecsi(tZbellsouth.net) Bob Vincent, Environmental Administrator, (Bob.Vincent(a)flheaIth.gov) Mission: Rick Scott ,:'� :. r To pnoect, promote & hpmve the health Governor_ of all people In Flolda Ihroogh Integrated o r Celeste Philip, MD, MPH �ate'�y8`mmna daeto�. HEALTH Surgeon General and Secretary Vision: To be the Healthlest State in tre Nation March 16.2017 SCANNED MichaeMaiemo BY Harbour Ridge Yacht and Country Club St. Lucie County 12600 Harbour Ridge Boulevard Palm City, Florida 34990 RE: Swimming Pool/Bathing Place Variance Request, Application #2855 Harbour Ridge Lifestyle Center, 13400 North Gilson Rd, Palm City, Florida Dear Mr. Salerno: The Advisory Review Board for Swimming Pools and Bathing Places reviewed your application for variance on March 8, 2017. When a variance is requested, the Advisory Review Board considers whether the hardship was caused intentionally, whether a reasonable alternative exists, and whether the health and safety of pool patrons are at risk. The Board recommended approval of your variance application request for the following: The applicant has constructed a pool with the bottom step riser height of 9 inches at one end and 11.4 inches at the other end. This is a violation of section 454.1.2.5.3 of the Florida Building Code: Maximum riser height of 10 inches (254 mm). Based upon the information submitted, I concur with the Advisory Review Board's recommendation to approve the above variance as requested. This variance, as approved, applies only to the sections of the Florida Building Code for which the variance was requested. This variance in no way exempts compliance with other state and local regulations. Should you disagree with this decision, a notice of rights is enclosed for your use. If you have any questions concerning this matter, please call August Ursin at (850) 245-4444, extension 2716. .Sincerely, _ Kendra F. Goff, PhD, DABT, CPM State'Tgxicologist & Chief ` (,) KFG/aau Enclosure cc: David J. Koerner, DOH -St. Lucie County Almar/Jackson Pools, Inc Florida Department of Health DNisio Bald Cy =Way, Hin Heald Pmthasse • FL 323 of Em7mm�nW Health ACCred tad Heats rtfneflt M Seld bypass Way, Bin 85 • Talla87-D86esee, FL 32399 Public Health Accreditation PHONE: &50P145d250 • FAX 850/487-0864 Florideliealth.Sov '� _ Scott Mission: r �,I ' ^ 01 RickGovernor To protmL promote & improve the health of all people in Florida through Integrated 1 lflV state, county &community efforts. o� Celeste Philip, MD, MPH HEALTH 1 TH Surgeon General and Secretary Vision: To be the Healthiest State in the Nation March 16, 2017 bCANNED BY Michael Salerno `f Lucie County Harbour Ridge Yacht and Country Club 12600 Harbour Ridge Boulevard Palm City, Florida 34990 RE: Swimming Pool/Bathing Place Variance Request, Application #2855 Harbour Ridge Lifestyle Center, 13400 North Gilson Rd, Palm City, Florida Dear Mr. Salerno: The Advisory Review Board for Swimming Pools and Bathing Places reviewed your application for variance on March 8, 2017. When a variance is requested, the Advisory Review Board considers whether the hardship was caused intentionally, whether a reasonable alternative exists, and whether the health and safety of pool patrons are at risk. The Board recommended approval of your variance application request for the following: The applicant has constructed a pool with the bottom step riser height of 9 inches at one end and 11.4 inches at the other end. This is a violation of section 454.1.2.5.3 of the Florida Building Code: Maximum riser height of 10 inches (254 mm). Based upon the information submitted, I concur with the Advisory Review Board's recommendation to approve the above variance as requested. This variance, as approved, applies only to the sections of the Florida Building Code for which the variance was requested. This variance in no way exempts compliance with other state and local regulations. Should you disagree with this decision, a notice of rights is enclosed for your use. If you have any questions concerning this matter, please call August Ursin at (850) 245-4444, extension 2716. Sincer ly, Ken ra F. Goff, PhD, DABT, CPM State oxicolocist & Chief KFG/aau Enclosure cc: David J. Koerner, DOH -St. Lucie County Almar/Jackson Pools, Inc Florida Department of Health Division of Disease Control & Health Protection • Bureau of Environmental Health Accredited Health Department 4052 Bald Cypress Way, Bin A-08 • Tallahassee, FL 32399 -public Health Accreditation Board PHONE: 850/245-0250 • FAX: 8501487-0864 FloridaHealth.gov Mission: To protect promote & improve the health of all people in Florida through integrated state, county & community efforts. Michael Salerno, General Manager Harbour Ridge Yacht & Country Club 12600 Harbour Ridge Blvd. Palm City, FL 34990 d'2YB��l HEALTH Vision: To be the Healthiest State in the Nation April 25, 2016 RE: Receipt of Application for Public Swimming Pool Operating Permit Harbour Ridge Lifestyle Center - Pool (DOH File # 56-60-1677363) 13400 NW Gilson Road, Palm City, FL 33490 Dear Mr. Salerno, Rick Scott Governor Celeste Philip, MD, MPH Interim State Surgeon General SCANNED BY St. Lucie County This is to acknowledge receipt of an application for an operating permit for the above referenced public swimming pool on April 20, 2016. You have met the preliminary submittal requirements of Chapter 514.03(1), Florida Statutes (FS), and may file an application for a public pool construction permit with your local building authority. The Florida Department of Health (FDOH) will review your application for completeness and notify you and the local building authority of any issues found in your proposal that must be addressed before an operating permit can be issued. The FDOH may request additional information within 30 days. After construction is completed and prior to opening, FDOH must conduct an initial inspection. Please provide notice to us at least 5 working days prior to the requested inspection date. Prior to issuing your operating permit allowing you to open to the public we will require: 1. A final set of plans and specifications as approved for construction by the local building authority; 2. A copy of the final inspection from the local building authority as defined in section 553.71, FS., 3. Revised application, if needed, reflecting any changes or corrections as a result of the Building Department. Thank you for your cooperation in this matter. Please contact me at 561-837-5995 if you have any questions. Sincerely, Darrel J. Graziani, P.E., R.S., C.P.O Environmental Administrator cc: Carl John Peterson, St. Lucie County Building Official (PetersonJ@stlucieco.org) -- David Koerner, EPH Director, FDOH St. Lucie County (David.Koemer@flhealth.gov Jamie Curtis, Engineers of Record (jamiecsi(n bellsouth.net) Bob Vincent, Environmental Administrator, (Bob.Vincent(c�r�flhealth.gov) Florida Department of Health v .Floridasliealth.eom Palm Beach County, Division of Environmental Public Health TWITTER:HealthyFLA P.O. Box 29, 800 Clematis Street West Palm Beach, FL 33402 FAGEBOOK:FLDeparbnenlofHealth PHONE: 561-8375900 • FAX: 561-837-5294 1 YOUTUBE: Bdoh