Loading...
HomeMy WebLinkAboutPROJECT INFORMATIONModel: 50REOZK, continued Cooling Radiator System Ambient temperature, °C (T) 50 (122) Engine jacket water capacity, L (gal.) 4.5 (1.19) Radiator system capacity, including engine, L (gal.) 12.3 (3.2) Engine jacket water flow, Lpm (gpm) 125(33) Heat rejected to cooling water at rated kW, dry exhaust, kW (Btu/min.) 37.8 (2207) Heat rejected to air charge cooler at rated kW, dry exhaust, kW (Btu/ 12 (682) min.) Water pump type Centrifugal Fan diameter, including blades, mm (in.) 597 (23.5) Fan, kWm (HP) 1,8 (2,3) Max. restriction of cooling air, intake and discharge side of radiator, 0.125 (0.5) kPA (in. H20) ' Enclosure with enclosed silencer reduces ambient temperature capability by YC (97). Operation Requirements Air Requirements SGANNEb By St. t_uci Countl Radiator -cooled cooling, air, m3/min: (scfm)' • 130 (4600) Combustion air, m3/min: (cfm) -• - 4.8(170) Heat rejected to ambient air. Engine, kW (Btu/min.) 132(750) Heat rejected to ambient air: Alternator, kW (Btu/min.) 7.6(435) Max. air intake restriction, kPa (in. Hg) z5.2(1.54) Radiator -cooled cooling air,.m3/min. (scfm) 130 (4600) Combustion air, m3/min. (cfm) 4.8(170) Heat rejected to ambient air: Engine, kW (Btu/min.) 13.2 (750) Heat rejected to ambient air: Alternator, kW (Btu/min.) 7.6(435) Max. air intake restriction, kPa (in. Hg) 5.2 (1.54) 'Air density = 1.20 kg/m3 (0.075 Ibm/ft3) Fuel Consumption Diesel, Lph (gph), at % load Rating Standby Fuel Consumption at 100% load 17.4 Loh (4.6 onh) Standby Fuel Consumption at 75% load Standby Fuel Consumption at 50% load Standby Fuel Consumption at 25% load Prime Fuel Consumption at 100% load Prime Fuel Consumption at 75% load Prime Fuel Consumption at 50% load Prime Fuel Consumption at 25% load Dimensions and Weights Dim Weight Spec Overall Size, L x W x H, mm (in.): Wide Skid Overall Size, L x W x H, mm (in.): Narrow Skid Weight (radiator model), wet, kg (Ib.): 13.2 Lph (3.5 gph) 9.1 Lph (2.4 gph) 5.3 Lph (1.4 gph) 16.1 Lph (4.2 gph) 12.1 Lph (3.2) 8.3 Lph (2.2 gph) 4.9 Lph (1.3 gph) Dim Weight Value 2300 x 1040 x 1133 (90.6 x 41.0 x 44.6) 1875 x 780 x 1067 (73.8 x 30.7 x 42.0) 802 (1769)