Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCESGANNhu Planning & Development Services Department BY ® - } Building & Code Regulations Division St. Lucie Countv . �i.. 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: South Shore Condo of Harbour Ridge Project Address: 12366 and 12368 Harbour Ridge Blvd. Permit#: Occupancy Type: R-2 Construction Type: V • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) 0 Py O Residential Addition LEo Any accessory structure requiring a building permit C O Any non-residential structure. ' Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2014 Code Fifth Edition with 20 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: _I X II _III IV Exposure Category: _B _C X D 4. Design Wind Velocity 165 mph X ASO _LRFD End Zone Width: 3 ft 5. Mean Roof Height 15 ft Roof Pitch: 6 :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Garage: +40/-50 7. Design Loads: Floor: PSF Roof/Dead: 30 PSF Roof/Live: 20 Balcony: PSF Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? _Yes I certify that, to of my knowledge and belief, the attached plans & specifications have been designed to comply w`t ly�t�e ,app' Atpy7ctural portions of the building codes currently adopted and enforced by St. Lucie COunty��lrtiftha 7iffal elements depicted on these plans provide adequate resistance to the design forcai's..'..fii:d\,�GE Sg V.; Charles A. Darden Jr. 76910 = No.76910 Print Name - Cert # & Co. Cert Auth. � CSM Engineering, LLC. tignae,r , fe,�t{uXS��PP; ;� 2081 SE Ocean Blvd., Suite 1A, Stuart, FL 34996 NAB \S �� Company Name & Address Revised 07/25/201d I l l l l t `\\