Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department ° 5(.ANNtV Building & Code Regulations Division W 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 St LUCB C ount Certification for Design Load Compliance Project Name: South Shore Condo of Harbour Ridge Project Address: 12378 and 12380 Harbour Ridge Blvd. Permit#: Occupancy Type: R-2 Construction Type: V INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition E COPY o Any accessory structure requiring a building permit o Any non-residential structure. Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2014 Code Fifth Edition with 20 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: _I X II _III _ IV Exposure Category: _B _C X D 4. Design Wind Velocity 165 mph X ASD _LRFD End Zone Width: 3 ft 5. Mean Roof Height t5 ft Roof Pitch: 6 :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Garage: +40/-50 7. Design Loads: Floor: PSF Roof/Dead: 30 PSF Roof/Live: 20 Balcony: PSF Dock: PSF Deck: _PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? _Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that7Tbt&nf�664(0/my knowledge and belief, the attached plans & specifications have been designed to compl;�oaiib 'eP pp) Fstrifp�ural portions of the building codes currently adopted and enforced by St. Lucie Cour\t�,- 1. 0 elements depicted on these plans provide adequate resistance to the design for s- cifled: No.76910 Charles A. Darden Jr. 76910 of = Print Name Cert # & Co. Cert Auth. I v CSM Engineering, LLC. si natiA,. •an�Seal _>' �w`� 2081 SE Ocean Blvd., Suite 1A, Stuart, FL 34996 Company Name & Address Revised 07/25/2014