S J' Planning & Development Services Department
o Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 J ` NNtu
Certification for Design Load Compliance BY11YY
Project Name: South Shore Condo of Harbour Ridge �t. Lucie C®unhl
Project Address: 12350, 12352, 12354, and 12356 Harbour Ridge Blvd.
Permit #:
Type: R-2 Construction Type: V
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida 2014 Code Fifth Edition with 20Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category: _I X II _III _ IV Exposure Category: B _C X D
4. Design Wind Velocity 165 mph X ASO LRFD End Zone Width: 3 ft
5. Mean Roof Height 15 ft Roof Pitch: 6 :12 Parapet: ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Garage: +40/-50
7. Design Loads: Floor: PSF Roof/Dead: 30 PSF Roof/Live: 20 Balcony: PSF
Dock: PSF Deck: _PSF Stairs: PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? Yes
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
eompIY.vjkhtt%Q abblip ble structural portions of the building codes currently adopted and enforced by St. Lucie
Co�,r Sabo.R.JkRha�f.Stru ctural elements depicted on these plans provide adequate resistance to the design
£i?rcFa�'sS�
Charles A. Darden Jr. 76910
U Na.7691D Print Name Cert # & Co. Cert Auth.
�/// CSM Engineering, LLC.
2081 SE Ocean Blvd., Suite 1A, Stuart, FL 34996
.�? - Company Name &Address
d cl�/2O 01191