Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEe S J' Planning & Development Services Department o Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 J ` NNtu Certification for Design Load Compliance BY11YY Project Name: South Shore Condo of Harbour Ridge �t. Lucie C®unhl Project Address: 12350, 12352, 12354, and 12356 Harbour Ridge Blvd. Permit #: Type: R-2 Construction Type: V INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2014 Code Fifth Edition with 20Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: _I X II _III _ IV Exposure Category: B _C X D 4. Design Wind Velocity 165 mph X ASO LRFD End Zone Width: 3 ft 5. Mean Roof Height 15 ft Roof Pitch: 6 :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Garage: +40/-50 7. Design Loads: Floor: PSF Roof/Dead: 30 PSF Roof/Live: 20 Balcony: PSF Dock: PSF Deck: _PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? Yes I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to eompIY.vjkhtt%Q abblip ble structural portions of the building codes currently adopted and enforced by St. Lucie Co�,r Sabo.R.JkRha�f.Stru ctural elements depicted on these plans provide adequate resistance to the design £i?rcFa�'sS� Charles A. Darden Jr. 76910 U Na.7691D Print Name Cert # & Co. Cert Auth. �/// CSM Engineering, LLC. 2081 SE Ocean Blvd., Suite 1A, Stuart, FL 34996 .�? - Company Name &Address d cl�/2O 01191