HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-1553
Certification for Design Load Compliance
Project Name: South Shore Condo of Harbour Ridge
Project Address: 12386 and 12388 Harbour Ridge Blvd.
Permit #:
Type: R-2 Construction Type: V
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
SCANNED
BY
St. Lucie Countv
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition C
o Any accessory structure requiring a building permit I L
P Y
o Any non-residential structure.
' Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida 2014 Code Fifth Edition with 20. Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category: _I X II _III IV Exposure Category: B C X D
4. Design Wind Velocity 165 mph X ASO _LRFD End Zone Width: 3 ft
5. Mean Roof Height 15 ft Roof Pitch: 6 :12 Parapet: ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Garage: +40/-50
7. Design Loads: Floor: PSF Roof/Dead: 30 PSF Roof/Live: 20 Balcony: PSF
Dock: PSF Deck: _PSF Stairs: PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure? --X—Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? Yes
I certify that ,(g0lel-l6W61/ryy knowledge and belief, the attached plans & specifications have been designed to
comply k(ii�h .pjp�> "Ap al portions of the building codes currently adopted and enforced by St. Lucie
' G�,tt..
Coun�c ,>strt ramelements depicted on these plans provide adequate resistance to the design
forcess;sp�q'rfied: �'• "
No. 76910 Charles A. Darden Jr. 76910
Print Name Cert # & Co. Cert Auth.
CSM Engineering, LLC.
Signatu'.-@ afitf5 '� o�� 2081 SE Ocean Blvd., Suite 1A, Stuart, FL 34996
Company Name & Address
Revised 07/25/2014