Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department ® Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 SCANNED Certification for Design Load Compliance St. Luce Coun tV Project Name: South Shore Condo of Harbour Ridge Project Address: 12398 and 12400 Harbour Ridge Blvd. Permit#: Occupancy Type: R-2 Construction Type: V INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition 4. LE o Any accessory structure requiring a building permit COPY o Any non-residential structure. " Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2014 Code Fifth Edition with 20 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: _I X II _III _ IV Exposure Category: B C X D 4. Design Wind Velocity 165 mph X ASO LRFD End Zone Width: 3 ft 5. Mean Roof Height 15 ft Roof Pitch: 6 :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Garage: +40/-50 7. Design Loads: Floor: PSF Roof/Dead: 30 PSF Roof/Live: 20 Balcony: PSF Dock: PSF Deck: _PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? Yes I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. \t atm UiN Ngay tructural elements depicted on these plans provide adequate resistance to the design `, ''��ENSc'' ��✓�'� Charles A. Darden Jr. 76910 _ •aJ�,• '•� Print Name Cert # & Co. Cent Auth. n No. 7 9 n �, CSM Engineering, LLC. Lite,61 DaW-ro gal V.-" vi eZefAj�' ��llllllltt\\ 2081 SE Ocean Blvd., Suite 1A, Stuart, FL 34996 Company Name & Address