Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL^ t�, Ijol �I�iJ.OB1F.0` RCIS Mome Lag In i' User Registration Hot Topics - Businesi a Product Approval Professional its USER: Public User Submit Surcharge Stats & Facts Publications i Pat Staff RCIS Site Map Links Search Product Approval Menu > Product or Application Search > Appilcatlom Ust hex`-dsy'�y F>4�� Search Criteria SCANNED BY St. Lucie Countv Refine Search Code Version 2014 FL# 7006 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model, Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL Search Results - Applications FL# Tyne Manufacturer Validated By Status FL7006-R9 Revision TKO Industries, Ltd Locke Bowden Approved ' History Category: Roofing Subcategory:ry; Asphalt Shingles (334) 300-1800 *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824 The State of Flodda Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. `Pursuant to Section 455.275(l), Florida statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.5., please dick here . Product Approval Accepts: El Im THESE PLANS AND ALL PROPOSED WORK ARESUF.iEl1'?()?t�' COCA=ErTIONS REOURED VeFIELD INwG 0Tfk18?HAT ., A9AYQE ��;GCE6��i�t'r' IN �Ot3fl TO -; 0041PLY WITH ALL APPWCADI9 00090, CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILRY OF THE CONTRACTOR OF RECORD C editSAr�E ST. LUCIE COUto REIRENp BLDG: DATE: IELEC: DATE: DATE: _ MECH: DATE:, April 15, 2015 Mr. Donald Shaw IKO Industries, Ltd. 40 Hansen Road South Brampton, Ontario L6W 3H4 Canada Customer ID: Subject: Dear Mr. Shaw, -< fM Approvals FM Approvals 1151 Boston -Providence Turnpike P.O. Box 9102 Norwood, MA 02C T: 781 762 4300 F: 781 762 9375 1000000686 IKO Industries Ltd.'s FM Approved and Specification Tested asphalt roof shingles ! 'd'he FIt (inhd lM1vm This letter is being written following in regards to your recent inquire regarding verif cation of the ASTM E108 testing of IKO Industries Ltd's asphalt roof shingles. I.KO's glass and organ0shingles that are FM fication Tested have been tested in accordance with ASTM El08. 1 have arranged the Approved and Speci shingles by category. IKO Industries Ltd.- Cambridge, Cambridge HD, Marathon 25, Marathon 25 AR, Marathon Ultra AR, Superglass Ultra AR, Crowne Slate, {IKO) Hip & Ridge 12, 'iJ Hip & Ridge Plus, Dynasty with ArmourZone, Cambridge IR, Leading 71 Edge Plus y CanroofCorpot anon, Inc. Biltmore, Biltmore AR, Superglass 25 M AR, Superglass Ultra AR, (CRC) Hip & Ridge 12, (CRC) Hin & Ridge Plug eclncanon restea roaucts: IKO Industries Ltd. - Cambridge AR Dual Black, Royal Estate, Marathon 20, Armour Starter, Armourshake, Roofshake HW Canroof Corporation; Inc. I Biltmore AR Dual Black, Superglass 20, Biltmor6 AR Please be advised that shingles noted above tested to previous versions of to meet the test criteria of the current version of ASTM E 108. If you have any questions please do not hesitate to contact me. Very truly yours, �.?/ Ia. David L. Alves Senior Engineer - Materials Group FM Approvals CX ♦ APPROVED E108 continue 1 � , Phillip J. Sir TTM - AVP FM Approv: t APPROVEDMa 1151 Boston -Pr( Norwood, MA 0 T: 781 255 4856 E: david.alves(a, Turnpike l Approvals° .Mmebr ni rAr F,N¢••� Md fbrep W'MOle,7�;" J b CONSTRUCTION MATERIALS TECHNOLOGIES I March 30, 2015 IKO Industries, Ltd 120 Hay Rd. Wilmington, DE 19809 Re: FBC FL7006 Sir(s), PRI Construction Materials Technologies has completed a technical review and instructions in compliance the 2014 Florida Building Code. This review was completed based on the receipt of following evidence from IKO 1) IKO Shingle Application Instructions — 3-Tab Shingles (EN-3Tab_Appins8AGXEFS-2012-11_reformatted 2013-02-rev07/13-F 2) IKO Laminated Shingles Application Instructions (EN-Laminated_Appins_8TTEFS-2012-04 reformatted 2013-02-rev07/' 3) IKO Hip and Ridge 12 Application Instructions (EN-HipandRidgel2_3HRTri-2013-08 reformatted 2013-08) 4) IKO Leading Edge Plus Shingle Application Instructions (EN-3LEP-Tri-2012-06_reformatted 2013-03) 5) ASTM D3161 Test Report (FM Approvals Project No. 30,10947 The attached instructions should be used in conjunction with the publishft mant instructions and applicable code. In the event the instructions conflict, these insl Statement of Independence: PRI Construction Materials Technologies and/or have nor plan to acquire a financial interest in any company manufacturing or the test reports are issued. f Signed: /�� 4 i Signed: Brad Grzybo ski Managing D rector Florida Date: April 30, 2015 Date: Attachments: A) IKO Shingle Application Instructions - 3-Tab B) IKO Laminated Shingles Application Instructions C) IKO Hip and Ridge 12 Application Instructions D) IKO Leading Edge Plus Application Instructions IKO-133-02-01 PRI Construc8on Materials Technologies, LLC. 6412 Badger Drive Tampa, FL 33610 Tel: 813.621-5777 Fax: 813-621-5840 e-mail: sealed shingle Ltd: f�(),t1Y application shall govern. Nguyen, FL P.E. do not ting products for which Number: 65034 2015 WebBite: http:lAv pricmt.com IKO Installation Instructions for Asphalt Shingles Page 2 of 5 IKO Shingyle Application Instructions — 3-Tab Shingles (ASTM D3161 , Class F — IKO Marathon 25 AR and CRC Superglass M25AR) ) t NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT, THESE INSTRUCTIONS WILL GOVERN. ROOF DECK: Solidly sheathed and fastened deck conforming to 2014 FBC. UNDERLAYMENT: Applied in accordance with building code requirements. For areas where the roof slope is less than 4" per foot down to 2" per foot, use 2 layers of underlayment conforming to building code requirements, the first sheet overlapping the eave protection by 19", followed by full 36" widths overlapping each preceding course by 19" or other Approved underlayments in accordance with the qualified application instructions. For areas where the roof slope is 4" per foot or greater, cover the deck with one ply of underlayment laid parallel to the eaves, with 2" horizontal laps and 4" end laps. Apply metal drip edges on top of any underlay along rake edges and directly to the deck along eaves in accordance with building code requirements. i NAILING: Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 3/8" diameter heads, long enough to penetrate through plywood or 3/4" into boards. Use 4 nails per shingle placed 6-1/8" above the butt edge, approx. 1" and 13'i from each end and 1/2" above each cutout. Drive nails straight so that nail head is flush with, but not cutting into shingle surface. a NAILING ON STEEP SLOPES: For steep slopes of 21" per foot (600) or more, use 6 nails per shingle placed as shown below. Ensure that no nail is within 2" of a joint/cutout of the underlying shingle. Seal down each shingle at time of application with three 1" diameter (approx. size and thickness of a quarter) spots of asphalt plastic cement placed udder the shingle 2" above the bottom edge and equally spaced along the shingle. Apply plastic cement inIlmoderation since excessive amounts may cause blistering. CAUTION: Shingles should seal to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the heat of direct sunlight. EXPOSURE: Installed s ingles shall have a maximum average exposur 811 . CON I � STEEP SLOPES SEALING STRIP i • •t-- i •� !1 \ 1 NAILS NAILS DO NOT NAIL INTO OR ABOVE THE SEALING STRIP PRI construction Materials Technologies, -I-C. 6412 Badger Drive Tampa, FL 33510 Tel: 813-621-5777 Fax; 813-621-5840 e-mail: matenalstestng@pdcmt.com WebSite: htlelw .;mcmt.com IKO Installation Instructions for Asphalt Shingles Page 3 of 5 IKO Laminated Shingles Application Instructions (ASTM D3161, Class F— Cambridge, Cambridge HD, and CRC Biltmore AR) F NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT, THESE INSTRUCTIONS WILL GOVERN. ROOF DECK: Solidly sheathed and fastened deck conforming to 2014 FBC. UNDERLAYMENT: Applied in accordance with building code requirements. For areas where the roof slope is less than 4" per foot down to 2" per foot, use 2 layers of underlayment conforming to building code requirements, the first sheet overlapping the eave protection by 19", followed by full 36" widths overlapping each preceding course by 19" or other Approved underlayments in accordance with the qualified application instructions. For areas where the roof slope is 4" per foot or greater, cover the deck with one ply of underlayment laid parallel to the eaves, with 2" horizontal laps and 4" end laps. Apply metal drip edges on top of any underlay along rake edges and directly to the deck along eaves in accordance with building code requirements. NAILING: Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at lead .3/8" diameter heads, long enough to penetrate through plywood or 3/4" into boards. Use 4 nails per shingle placed in the nail line 7-3/8" below the top edge, approx. 1" and 13" in from each end. Drive nails straight so that nail head is flush with, but not cutting into shingle surface, d NAILING ON STEEP SLOPES: For steep slopes of 21" per foot (60°) or more, use 6 nails per shingle placed as shown below. Ensure that no nail is within 2" of a joint/cutout of the underlying shingle. Seal down each shingle at time of application with three 1" diameter (approx. size and thickness of a quarter) spots of asphalt plastic cement placed under the shingle 2" above the bottom edge and equally spaced along the shingle. Apply plastic cement in moderation since excessive amounts may cause blisterting. CAUTION: Shingles should seal to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the heat of direct sunlight. I EXPOSURE: Installed shingles shall have a maximum average exposure of 5-7/6". G 3/ NAIL LINE PROPER APPLICATION REQUIRES THAT THE NAILS PENETRATE BOTH THE OVERLAY AND PORTIONS OF THE SHINGLE PRI Construction Materials Technologies, LLC. 641213adgerDwe Tampa,FL33610 Tel:813.621-5777 Fax:813-621.5840 e-mail:matenalstesting@pncmLwm WebSits:Nlp:1Nw .pdcmt.wm IKO Installation Instructions for Asphalt Shingles. Page 4 of 5 IKO Hip and Ridge 12 Application Instructions I (ASTM D3161, Class F — IKO Hip and Ridge 12) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT, THESE INSTRUCTIONS WILL GOVERN. Cut hip and ridge shingles into thirds, using the perforation marks as a cutting guide. These shingles are designed for a 5 1/8" (130 mm) exposure. (For a neater appearance, the top of each side of each piece has been factory trimmed on a 1" (25 mm) taper (see drawing). Bend each piece over the hip or ridge, and nail 5 5/8" (143 mm) above the butt edge 1" (25 mm) in from each edge, exposing each piece 5 1/8" (130 mm). Apply hip pieces starting at the lower end of the hip, working up toward the ridge. On hip roofs, apply ridge pieces starting at each end, meeting in the middle. On gable roofs, apply ridge pieces starting at the end opposite to the prevailing wind direction and continue to the other end. Note: To obtain a three-dimensional effect, (which is recomrr"ended, but not required), apply hip and ridge shingles double thickness by stacking 2 pieces on top of one another, the lower piece extending about 3/4" (19 mm) further than the top piece (see diagram). The final shingle should be set in cement, and the exposed nail heads of the final shingle should be covered with cement. Prior to application in cold weather, storing the shingles in a heated area will allow for easier bending. I I 3 NOTE: SHINGLES MUST BE APPLIED PROPERLY. THEY ARE DESIGNED FOR USE AS HIP AND RIDGE SHINGLES ONLY, AND SHOULD NOT BE USED FOR ANY OTHER APPLICATIONS. WE ASSUME NO RESPONSIBILITY FOR?LEAKS OR DEFECTS RESULTING FROM POORAPPLICATION OR FAILURE TO PROPERLY PREPARE$THE SURFACE TO BE ROOFED OVER, OR FAILURE TO PROVIDE PROPER VENTILATION IN ACCORDANCE WITH MINIMUM PROPERTY STANDARDS REQUIREMENTS. REVIEW ALL APPLICABLE BUILDING CODES, MINIMUM PROPERTY STANDARDS, AND REQUIREMENTS PRIOR TO APPLYING THESE SHINGLES USING THESE APPLICATION INSTRUCTIONS. a7) e 4' iAFEP COi T "Irk OREM PRI Construction Materials Technologies, U.C. 641?Badger Drive Tampa, FL 33610 Tel: 813-621-5777 Fax: 813-621-5840 e-mail: matedalstes6ng@pdcmtcom WebSite: htlp9AM .ladcmt.mm IKO Installation Instructions for Asphalt Shingles Page 5 of 5 k Leading Edge Plus Application Instructions (ASTM D3161, Class F — IKO Leading Edge Plus) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED , APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT, THESE INSTRUCTIONS WILL GOVERN. I I N 1. Apply any underlayment, eave protection, valley flashings, or drip edges to roof deck as required. 2. Each 39 3/8" x 131/4" (1000 mm x 336 mm) IKO Leading Edge Plus strip is perforated lengthwise for separation into two (2) shingles. Take one IKO Leading Edge Plus strip and fold flat at perforation to separate. 3. Take one of the separated shingles 39 3/8" x 6 5/8" (1000 mm x 168 mm) and remove approximately 20"(500 mm). Install this shingle on the lower left corner of the roof deck, granule side up, with the factory installed sealant adjacent to the eaves. The shingle should overharg the rake edge and eaves by a nominal 1/4" (6 mm) minimum. Fasten the shingle to the roof deck with nails located 3" to 4" (75 mm to 100 mm) from the eave edge and 1" (25 mm) in from each end. i' 4. Take the leftover 20" (500 mm) piece shingle. Rotate the piece and align itivertically up the rake edge with the factory installed sealant adjacent to the outer edge of the roof. The shingle should overhang the rake edge by a nominal 1/4" (6 mm) minimum. Fasten the shingle to the roof deck with fasteners located 3" to 4" (75 mm to 100 mm) from the rake edge and 1" (25 mm) in from each end. IKO 5. Repeat Steps 3 — 4 for the right lower corner of the roof deck. NAILING: Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 3/8" (9 mm) diameter heads, long enough to penetrate through plywood or 3/4" (20 mm) into boards. Use 4 nails per shingle placed 3" to 4" (75 mmlto 100 mm) from the eave edge and approximately 1" and 13" (25 mm and 330 mm) in from each end. 6. Apply full-length IKO Leading Edge Plus shingles to the remaining eave edges of the roof deck. Install the shingles granule side up with the factory applied sealant adjacent to the eaves. The shingles should overhang the rake edge and eaves by a nominal 1/4" (6 mm) minin4um. Fasten the shingles to the roof deck with nails located 3" to 4" (75 mm to 100 mm) from the eave edge, 4 nails per shingle. 7. Apply roof shingles as per the instructions printed on each product's package. Make certain the first course of field shingle. lies flush with the edges of the fastened IKO Leading Edge Plus. In this way, the sealant on the IKO Leading Edge Plus shingles will adhere to the first`; course field shingles and help keep them from lifting in high winds. e PRI Construcgon Materials Technologies, I.I.C. 6412 Badger Drive Tampa, FL 33610 Tel: 813.621-57T7 Fax: 813-621.5840 Ir 5� email: matedalsles Fng@pticmLwm ) WebSite: http:lAv .pricml.wm