HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department limo`J Epril'iS
Building & Code Regulations Division As
2300 Virginia Avenue, Fort Pierce, FL 34982- (772) 462-1553 MINNVOS
Certification for Design Load Compliance
Project Name: South Shore Condo of Harbour Ridge
Project Address: 12410, 12412, 12414, and 12416 Harbour Ridge Blvd.
Permit #: Occupancy Type: R-2 Construction Type: V
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family) FILE
C%Ioey
o Residential Addition _
o Any accessory structure requiring a building permit M III
o Any non-residential structure.
` Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the It above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida 2014 Code Fifth Edition with 20Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category: _I X II _III —IV Exposure Category: B _C X D
4. Design Wind Velocity 165 mph X ASD _LRFD End Zone Width: 3 ft
5. Mean Roof Height 75 ft Roof Pitch: 6 :12 Parapet: ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Garage: +40/-50
7. Design Loads: Floor: PSF Roof/Dead: 30 PSF Roof/Live: 20 Balcony: PSF
Dock: PSF Deck: _PSF Stairs: PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? _Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify thatkyt9%tW,•b✓ b1 pfiny knowledge and belief, the attached plans & specifications have been designed to
comply \�Ni�,t!5. a0pl j@6t(tiq ral portions of the building codes currently adopted and enforced by St. Lucie
Counh� . ac�;r..�aAQ %4. u ,elements depicted on these plans provide adequate resistance to the design
for fi3 t ied: u�
_ No. 76910 - Charles A. Darden Jr. 76910
' L Print Name Cart # & Co. Cert Auth.
CSM Engineering, LLC.
SignatCvq��'an�Seal�%���` 2081 SE Ocean Blvd., Suite 1A, Stuart, FL 34996
Company Name & Address
Revised 07/25/2014