Project Name: South Shore Condo of Harbour Ridge
Project Address: 12406 and 12408 Harbour Ridge Blvd.
Permit#: Occupancy Type: R-2 Construction Type: V
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure. F I LEE` C 0 P
' Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida 2014 Code Fifth Edition with 20 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category: _I X II _III _ IV Exposure Category: _B _C X D
4. Design Wind Velocity 165 mph X ASD _LRFD End Zone Width: 3 ft
S. Mean Roof Height 15 ft Roof Pitch: 6 :12 Parapet: ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Garage: +40/-50
7. Design Loads: Floor: PSF Roof/Dead: 30 PSF Roof/Live: 20 Balcony: PSF
Dock: PSF Deck: _PSF Stairs: PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not
10. Design Soil Bearing Pressure: PSF Soil Test Reports -Submitted? _Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the b st of my knowledge and belief, the attached plans & specifications have been designed to
11I I
comply with\th9�� li1c able11�s�fNpfural portions of the building codes currently adopted and enforced by St. Lucie
County.;�biS�[t'tln-/atA.'stQy+;tu>lal�elements depicted on these plans provide adequate resistance to the design
forcessped: L\�EI.SE �N�•_i,
' 10 Charles A. Darden Jr. 76910
No:7,69'•
j_- Print Name Cent # & Co. Cert Auth.
A 1�: I CSM Engineering, LLC.
2081 SE Ocean Blvd., Suite 1A, Stuart, FL 34996
A� F.;�\�� Company Name & Address