Loading...
HomeMy WebLinkAboutJAMB CONNECTION SUPPLEMENTA Division of Overhead Door Corporation FIyLL CO" SCANNED BY St. Lucie Countv Jamb Connection Supplement This document provides a series of connection schedules and basic detailing concepts for the connection of garage door jambs to building frames with the use of various fasteners. DASMA Technical Data Sheet TDS-161 may be used as an alternate to this document. PM 324620 Rev. P16 SCHEDULEI 5/16" DIAMETER LAG SCREWS MAXIMUM SPACING OF LAG SCREWS PER JAMB IN MAIN SUPPORT MEMBER SPECIES SYP SPECIFIC GRAVITY-0.55 DOUGLAS FIR SPECIFIC GRAVITY -0.46 SPF SPECIFIC GRAVITY -0.42 LOAD PER JAMB LB/ 0DTE3 100 24 24 24 120 24 24 24 140 24 24 24 160 24 24 24 180 24 24 24 200 24 24 24 220 24 24 22 240 24 24 20 260 24 22 19 280 24 20 17 300 24 19 16 320 22 18 15 340 21 16 14 360 20 16 13 380 19 15 13 400 18 14 12 420 17 13 11 440 16 13 11 460 15 12 10 480 15 12 10 500 14 11 10 520 14 11 9 540 13 10 9 560 13 10 8 580 12 9 8 600 12 9 8 620 11 9 8 640 11 9 7 660 11 8 7 680 10 8 7 700 10 8 7 720 10 8 6 740 9 7 6 760 9 7 6 780 9 7 6 Soo 9 7 6 NZ EN&FF % No.51737 ± \ ,r r. STATE OF 0 1. BASED ON 5116" DIAMETER LAG SCREWS WITH 1-1/2" O.D. WASHERS WITH A 1-9/32" THREAD PENETRATION INTO SEASONED DRY WOOD SUPPORTING STRUCTURE. 2. PROVIDE QUANTITY OF LAG SCREWS AS REQUIRED TO MAINTAIN MAXIMUM SPACING AS SHOWN IN TABLE WITH A MINIMUM OF THREE (3) LAG SCREWS PER JAMB. LAG SCREWS AT TOP AND BOTTOM OF JAMB SHALL BE PLACED A MAXIMUM OF 6" FROM THE END OF THE JAMB. 3. LOAD PER JAMB CALCULATED BY TAKING DESIGN LOAD (PSF) TIMES DOOR WIDTH (FT) DIVIDED BY 2. EXAMPLE: DESIGN LOAD = 30psf DOOR WIDTH = 16ft LOAD PER JAMB = 30psf x 16f /2 - 2401b/ft CUPY FILt 4. CHART IS BASED ON 6' 6" MINIMUM AND 24'-0" MAXIMUM DOOR HEIGHT. 5. DOOR JAMB TO BE 2x4 OR LARGER NO.2 GRADE SPF (SPECIFIC GRAVITY>=0.42) LUMBER OR BETTER MOUNTED TO SUPPORT STRUCTURE. IF MOUNTING OVER DRYWALL, INCREASE FASTENER LENGTH TO ACHIEVE MINIMUM REQUIRED PENETRATION. 6. DESIGN OF THE SUPPORT STRUCTURE SHALL BE THE SOLE RESPONSIBILITY OF THE BUILDING DESIGNER AND SHALL BE DESIGNED FOR THE JAMB LOAD LISTED IN ABOVE TABLE AS CALCULATED PER NOTE 3. 7. MINIMUM EDGE DISTANCE SHALL BE 1/2", MINIMUM FASTENER SPACING SHALL BE 1-1/2", AND ALL HOLES SHALL BE PRE -DRILLED TO PREVENT SPLITTING. 8. LAG SCREWS SHALL CONFORM TO ANSI /ASME STANDARD B18.2.1. Digitally signed by John E. Scates, P.E. Date: 2015.02.20 09:56:33-06'00' John E. Scates, P.E. 3121 Fairgate Dr. Carrollton, TX 75007 FL PE 51737 TX PE 56308/F2203 Revision P16 SCHEDULE2 16d COMMON WIRE NAILS AND 16d THREADED HARDENED -STEEL NAILS MAXIMUM NAIL SPACING PER JAMB IN MAIN SUPPORT MEMBER SPECIES SYP SPECIFIC GRAVITY -0.55 DOUGLAS FIR SPECIFIC GRAVITY -0.46 SPF SPECIFIC GRAVITY -0.42 LOAD PER JAMB LB1FTNDTE3 100 24 24 19 120 24 20 16 140 21 17 14 160 18 15 12 180 16 13 10 200 15 12 9 220 13 11 8 240 12 10 8 260 11 9 7 280 10 8 7 300 10 8 6 320 9 7 6 340 8 7 n/a 360 8 6 n/a 380 7 6 n/a 400 7 6 n/a 420 7 n/a n/a 440 6 n/a n/a 460 6 n/a n/a 480 6 n/a n/a 500 6 Na n/a 520 Na n/a Na 540 n/a n/a n/a 560 ` n/a Na n/a 580 n/a n/a n/a 600 n/a Na n/a 620 n/a n/a n/a 640 n/a n/a n/a 660 n/a n/a n/a 680 Na n/a n/a 700 n/a Na n/a 720 n/a _ n/a n/a 740 Na Na n/a 760 Na n/a n/a 780 Na Na n/a 800 n/a n/a n/a \`\\, gC,� 4. M737 -O , 16STATE OF Z, A"'AORVDp ,�///�ss 1. BASED ON 16d COMMON WIRE NAILS (0.162"x3-1/2") OR 16d THREADED HARDENED -STEEL NAILS(0.148"x3-1/2") WITH A MINIMUM PENETRATION OF 2" INTO SIDE GRAIN OF MAIN MEMBER. 2. NAILS SHALL BE PROVIDED IN PAIRS AT MAXIMUM SPACING AS SHOWN IN TABLE WITH A MINIMUM OF THREE (3) PAIRS OF NAILS PER JAMB. NAILS AT TOP AND BOTTOM OF JAMB SHALL BE PLACED A MAXIMUM OF 6" FROM THE END OF THE JAMB. 3. LOAD PER JAMB CALCULATED BY TAKING DESIGN LOAD (PSF) TIMES DOOR WIDTH (FT) DIVIDED BY 2. EXAMPLE: DESIGN LOAD =30ps1 DOOR WIDTH =I6R i�gMDj�.COPY 4. CHART IS BASED ON 6'-6" MINIMUM AND 4LOAD PER '-0" MAXIMUM6DOOR HEIGHT. F e ��'` S. DOOR JAMB TO BE 2x4 OR LARGER NO. 2 GRADE SPF (SPECIFIC GRAVITY>=0.42) LUMBER OR BETTER MOUNTED TO SUPPORT STRUCTURE. IF MOUNTING OVER DRYWALL, INCREASE FASTENER LENGTH TO ACHIEVE MINIMUM REQUIRED PENETRATION. 6. DESIGN OF THE SUPPORT STRUCTURE SHALL BE THE SOLE RESPONSIBILITY OF THE BUILDING DESIGNER AND SHALL BE DESIGNED FOR THE JAMB LOAD LISTED IN ABOVE TABLE AS CALCULATED PER NOTE 3. 7. EDGE DISTANCES, END DISTANCES AND SPACINGS SHALL BE SUFFICIENT TO PREVENT SPLITTING OF THE WOOD. Digitally signed by John E. Scates, P.E. .__-_.._. Date: 2015.02.2009:56:58-0600' John E. Scates, P.E. 3121 Fairgate Dr. Carrollton, TX 75007 FL PE 51737 TX PE 56308/F2203 Revision P16 SCHEDULES 3/8"0 A307 HEADED OR HOOKED ANCHOR BOLTS IN NORMAL WEIGHT CONCRETE MAXIMUM SPACING OF ANCHOR BOLTS PER JAMB (IN) LOAD PER JAMB (LB/FT)"' 2000 PSI CONCRETE 2500 PSI CONCRETE 3000 PSI CONCRETE 100 24 24 24 120 24 24 24 140 24 24 24 160 24 24 24 180 24 24 24 200 24 24 24 220 24 1 24 24 240 24 24 24 260 24 24 24 280 24 24 24 300 24 24 24 320 24 24 24 340 24 24 24 360 23 24 24 380 22 24 24 400 20 24 1 24 420 19 24 24 440 19 23 24 460 18 22 24 480 17 21 24 500 16 20 24 520 16 20 24 540 15 19 23 560 14 18 22 580 14 1 18 21 - 600 13 17 20 620 13 16 20 640 13 16 19 660 12 15 19 680 12 15 18 700 11 14 17 720 11 14 17 740 11 14 16 760 11 13 16 780 10 13 1 16 800 10 13 1 15 \��)0?y�pENdF•�44 //� i : No. 51737 r r. 4 STATE OF r: �rIr ,fy\ /i O.o •.!�LORVA i -p . /�Z/�sSIONA; 0a��\\ 1. BASED ON 3/8"0 A307 HEADED OR HOOKED (1.69" MIN. HOOK LENGTH) ANCHOR BOLTS WITH A2" O.D. WASHER WITH A MINIMUM EMBEDMENT DEPTH OF 3" AND A MINIMUM EDGE DISTANCE OF 3". 2. PROVIDE QUANTITY OF ANCHOR BOLTS AS REQUIRED TO MAINTAIN MAXIMUM SPACING AS SHOWN IN TABLE WITH A MINIMUM OF THREE (3) ANCHOR BOLTS PER JAMB. ANCHOR BOLTS AT TOP AND BOTTOM OF JAMB SHALL BE PLACED A MAXIMUM OF 6" FROM THE END OF THE JAMB. 3. LOAD PER JAMB CALCULATED BYTAKING DESIGN LOAD (PSF) TIMES DOOR WIDTH (FT) DIVIDED BY 2. EXAMPLE: DESIGN LOAD = 30psf DOOR WIDTH = 16ft , / LOAD PER JAMB = 30psf x 16ft/2 = 2401b/ft pffm 09— F` (COPY' 4. CHART IS BASED ON 6'-6" MINIMUM AND 24'-0" MAXIMUM DOOR HEIGHT. F I LK3 5. DOOR JAMB TO BE 2x6 OR LARGER NO.2 GRADE SPF (SPECIFIC GRAVITY>=0.42) LUMBER OR BETTER MOUNTED TO SUPPORT STRUCTURE. IF MOUNTING OVER DRYWALL, INCREASE FASTENER LENGTH TO ACHIEVE MINIMUM REQUIRED PENETRATION. 6. DESIGN OF THE SUPPORT STRUCTURE SHALL BE THE SOLE RESPONSIBILITY OF THE BUILDING DESIGNER AND SHALL BE DESIGNED FOR THE JAMB LOAD LISTED IN ABOVE TABLE AS CALCULATED PER NOTE 3. Digitally signed by John E. Scates, P.E. Approved Date: 2015.02.20 09:57:27 -06'00' John E. Scates, P.E. 3121 Fairgate Dr. Carrollton, TX 75007 FL PE 51737 TX PE 56308/F2203 Revision P16 J SCHEDULE4 3/8"0 SIMPSON TITEN HD SCREW ANCHORS MAXIMUM SPACING OF ANCHORS PER JAMB (IN) LOAD PER JAMB LB/FTNOTs4 2500 PSI CONCRETENon" 4000 PSI CONCRETE NOTE1 2000 PSI GROUT FILLED CMUNorez 100 24 24 24 120 24 24 24 140 24 24 24 160 24 24 24 180 24 24 24 200 24 24 24 220 24, 24 24 240 24 24 24 260 24 24 16 280 24 24 16 300 24 24 16 320 24 24 16 340 24 24 16 360 24 24 16 380 24 24 8 400 24 24 8 420 24 24 8 440 24 24 8 460 24 24 8 480 24 24 8 500 24 24 8 520 24 24 8 540 24 24 8 560 23 24 8 580 22 24 8 600 21 23 8 620 21 22 8 640 20 22 8 660 19 21 8 680 19 20 8 700 18 20 8 720 18 19 8 740 17 19 N/A 760 17 18 N/A 780 16 1 18 WA 800 16 1 17 WA No. 51737 • -O STATE OF ///���•SSION L 1. BASED ON 3/8"0 SIMPSON TITEN HD SCREW ANCHOR WITH A 1-3/4" O.D. WASHER INTO NORMAL WEIGHT UNCRACKED CONCRETE WITH A MINIMUM EMBEDMENT DEPTH OF 2-3/4" AND A MINIMUM EDGE DISTANCE OF 2-3/4". 2. BASED ON 3/8"0 SIMPSON TITEN HD SCREW ANCHOR WITH A 13/4" O.D. WASHER INTO GROUT FILLED CMU WITH A MINIMUM EMBEDMENT DEPTH OF 2-3/4", A MINIMUM EDGE DISTANCE OF 4", AND A MINIMUM END DISTANCE OF 4". CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90 AND GROUT SHALL CONFORM TO ASTM C476. 3. PROVIDE QUANTITY OF SCREW ANCHORS AS REQUIRED TO MAINTAIN MAXIMUM SPACING AS SHOWN IN TABLE WITH A MINIMUM OF THREE (3) SCREW ANCHORS PER JAMB. SCREW ANCHORS AT TOP AND BOTTOM OF JAMB SHALL BE PLACED A MAXIMUM OF 6" FROM THE END OF THE JAMB. 4. LOAD PER JAMB CALCULATED BYTAKING DESIGN LOAD (PSF) TIMES DOOR WIDTH (FT) DIVIDED BY 2. EXAMPLE: DESIGN OORWIDTH=l6ft DOOR WIDTH = 16ft LOAD PER JAMB = 30psf x 16ft/2 = 240lb/ft 5. CHART IS BASED ON 6'-6" MINIMUM AND 24'-0" MAXIMUM DOOR HEIGHT. FIL'Imm COPY 6. DOOR JAMB TO BE 2x6 OR LARGER NO.2 GRADE SPF (SPECIFIC GRAVITY>=0.42) LUMBER OR BETTER MOUNTED TO SUPPORT STRUCTURE. IF MOUNTING OVER DRYWALL, INCREASE FASTENER LENGTH TO ACHIEVE MINIMUM REQUIRED PENETRATION. 7. DESIGN OF THE SUPPORT STRUCTURE SHALL BE THE SOLE RESPONSIBILITY OF THE BUILDING DESIGNER AND SHALL BE DESIGNED FOR THE JAMB LOAD LISTED IN ABOVE TABLE AS CALCULATED PER NOTE 4. 8. SCREW ANCHORS SHALL BE INSTALLED PER MANUFACTURER'S WRITTEN INSTRUCTIONS. Digitally signed by John E. Scates, P.E. Approved Date: 2015.02.20 09:58:01-06'00' John E. Scates, P.E. 3121 Fairgate Dr. Carrollton, TX 75007 FL PE 51737 TX PE 56308/F2203 Revision P16 SCHEDULES 3/8" 0 HILTI KWIK BOLT 3 EXPANSION ANCHOR MAXIMUM SPACING OF ANCHORS PER JAMB (IN) LOAD PER JAMB LB/F NOTs4 2500 PSI CONCRETENOTE' 4000 PSI CONCRETE NOTE ' 2000 PSI GROUT FILLED CMUNOTE2 100 24 24 24 120 24 24 24 140 24 24 24 160 24 24 24 180 24 24 24 200 24 24 24 220 24 24 24 240 24 24 24 260 24 24 24 280 24 24 24 300 24 24 24 320 24 24 16 340 24 24 16 360 24 24 16 380 24 24 16 400 24 24 16 420 24 24 16 440 24 24 16 460 24 24 16 480 24 24 8 500 24 24 8 520 24 24 8 540 24 24 8 560 24 24 8 580 24 24 8 600 23 23 8 22 8 22 8 21 8 20 8 S E22 20 8 19 8 19 8 18 8 780 18 8 800 17 17 8 \\\\\\�`�! g�`i� �0�,�\GeNd�i•�t4 //� No. 51737 — * STATE OF �� W` • (v Nt- //j, ION' ; �a�\\N 1. BASED ON 3/8"0 HILTI KW I BOLT 3 EXPANSION ANCHOR WITH A 1-3/4" O.D. WASHER INTO NORMAL WEIGHT UNCRACKED CONCRETE WITH A MINIMUM EMBEDMENT DEPTH OF 2-1/2" AND A MINIMUM EDGE DISTANCE OF 3". 2. BASED ON 3/8"0 HILTI KW IK BOLT 3 EXPANSION ANCHOR WITH A 1-3/4" O.D. WASHER INTO GROUT FILLED CMU WITH A MINIMUM EMBEDMENT DEPTH OF 2-1/2" AND A MINIMUM EDGE DISTANCE OF 4". ONLY ONE ANCHOR PER MASONRY UNIT CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90 AND GROUT SHALL CONFORM TO ASTM C476. 3. PROVIDE QUANTITY OF ANCHORS AS REQUIRED TO MAINTAIN MAXIMUM SPACING AS SHOWN IN TABLE WITH A MINIMUM OF THREE (3) ANCHORS PER JAMB. ANCHORS AT TOP AND BOTTOM OF JAMB SHALL BE PLACED A MAXIMUM OF 6" FROM THE END OF THE JAMB. 4. LOAD PER JAMB CALCULATED BY TAKING DESIGN LOAD (PSF) TIMES DOOR WIDTH (FT) DIVIDED BY 2. EXAMPLE: DESIGN LOADOORWIDTH =16ft DOOR WIDTH -16ft LOAD PER JAMB = 30psf x 16ft/2 = 240Ib/ffF I 5. CHART IS BASED ON 6'-6" MINIMUM AND 24'-0" MAXIMUM DOOR HEIGHT. L"E" 6. DOOR JAMB TO BE 2x6 OR LARGER NO. 2 GRADE SPF (SPECIFIC GRAVITY>=0.42) LUMBER OR BETTER MOUNTED TO SUPPORT STRUCTURE. IF MOUNTING OVER DRYWALL, INCREASE FASTENER LENGTH TO ACHIEVE MINIMUM REQUIRED PENETRATION. 7. DESIGN OF THE SUPPORT STRUCTURE SHALL BE THE SOLE RESPONSIBILITY OF THE BUILDING DESIGNER AND SHALL BE DESIGNED FOR THE JAMB LOAD LISTED IN ABOVE TABLE AS CALCULATED PER NOTE 4. 8. SCREW ANCHORS SHALL BE INSTALLED PER MANUFACTURER'S WRITTEN INSTRUCTIONS. Digitally signed by John E. Scates, P.E. Approved Date: 2015.02.20 09:58:27 -06'00' John E. Scales, P.E. 3121 Fairgate Dr. Carrollton, TX 75007 FLPES1737 TXPE56308/F2203 Revision P16 Wa�e® 0 on 3395 ADDISON DRIVE PENSACOLA, FLORIDA 32514 (850) 474-9890 Digitally signed by John E. Scates, P.E. Date: 2015.02.20 09:58:53 -06'00' .KHN ESTATES, PE 312% PAIROAR DR. CAMVIXLRM', TX ]300T M PE 31137 TA PE MWS/Fi 03 PROFESSIONAL ENGNEDi5 SEAL PROMOM ONLY FOR YERSCATON OF WNOLWO CONSTPUCTON OETMLS. SEE DETAILS 1. 2. AND 3 - REQUIRED FOR VERTICAL ® POST REINFORCING SYSTEMS. 6' MAX. �' FASTENERS PER SCHEDULES 1 THIRD 4 MINIMUM 2K4 STRUCTURAL GRADE LUMBER FOR DOOR HEIGHT MAXIMUM SPACING ATTACHMENT TO WOOD SUBSTRATE OR MINIMUM 2r6 FOR ATTACHEMENT TO CONCRETE AND TROUT FlLLEO CMU, ttP. 6' MAX. DOOR WD1H DETAII I •YWYDY25VO P51 CONCHEEIYIIMM MINIMUM 25VO.P5 CONCHEEUM25VO P51 CONCRE7 NOT' MAXIMUM DESIGN LOAD CAPACITY OF 2085 LEE. HEADER LOCK LOCK L° J 1-1/2' /` J (4) 3/B' SIMPSON TIMM HD SCREW (4) 3/B' DIA. LAC SCREWS ANCHOR WTH A 1-1/4' WASHER AND WITH 1-1/4' O.O. WASHERS. A MINIMUM EMBEDMENT DEPTH OF EAG SCREWS SHAD. HAVE A 2-3/4' AND A MINIMUM EDGE MINIMUM PENETRATION OF DISTANCE OF 4'. 1-9/32' INTO THE MAIN SUPPORT MEMBER, DETAII I DETAILS MINIMUM 000 P5g0T FLONU MOD SUPPORT STRUCTURE SUPPORT STRMCT RE NOW, MAXIMUM DESIGN LOAD NOT MAXIMUM DESIGN LOAD CAPACTY OF 2400 IBS. CAPACITY OF 2430 LBS. DRAWN SHEET 1 OF 2 CHECKEDV DRAWING PART NO. REV. JAMB CONNECTION SUPPLEMENT 324620 P16 Wa_S0a pa�ton 3395 ADDISON DRIVE PENSACOLA. FLORIDA 32514 (850) 474-9890 JAMB MAC y�pENaF•.•S MAO Y: • i 10. 51737 E .. i �O �, gTATE OF ; ly 1111111 Digitally signed by John E. Scates, P.E. Date: 2015.02.20 09:59:26-06'00' 4MN E. SCAIEA PE 3121 PAIRCAIE DR. c51NOLLTw, 11 R PE SI"/IT TIC5.N!9/ PE 9FPSOJ FAQ 551014 1 ENONEMR YAL PRONGED ONLY FM YENNCATON OF WNDLOM CMSI MnC DETAILS. TIRE. DESIGN 2 3/4- LOIURE SHALL MIN EDGE GIST NSIBIUTY OF 7 RECORD PSON TIIEN HD, TIN EMBED. MIN EN JMB LOCAnON ACKET PND XT Ex xu DIRECT CLN R TE MWNTNC GFTAII MIN 2 Y 4 SPF (0-0.42) OR BETTER WALL SWD NOff; MAX ALLOWABLE FASTENER LOAD MAY EXCEED TIE DESIGN LOAD OF TIE STRUCTURE. DESIGN OF MPPORTING STRUCTURE SHALL BE THE SOLE RESPONSIBILITY OF THE PROFESSIONAL OF RECORD FOR THE STRUCTURE LAG SCREW JAMB BRACKET 1/4-20N9/16' TRACT( BOLT AND 1/4-20 HEX NU MAN DIRECT W000 PER IA FASTENER MAX b0 IRS PFR LAG FASTENER SHEET 2 OF 2 JAMB CONNECTION SUPPLEMENT DRAWING PART NO. REV. 324620 P16