Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
STRUCTURAL INSPECTION REPORT
� I IM M B�lst ENGINEERING, INC. MOIA BOWLES VIU AMIZAR & ASSOCIATES a' gy ED STRUCTURAL INSPECTION REPORT Lucie County Project Number: 15-320 CIVIL. STRUCTURAL• SURVEYING . ENVIRONMENTAL Project Name: Treasure Cove Dunes 1835 20th Street. Vero Beach, FL 32960 772.569.0035 . Fax:772.778.3617 www.mbveng.com Crl#3)28 Owner: Treasure Cove Dunes Inspection Date: 8/1/2017 Weather: Sunny Permit #: Bldg 2: SLC 1606-0391 Contractor: Daniello and Associates Inspector: Rodolfo Villamizar, P.E. Project Address: 4100 N AlA, Bldg 2 Qualified By: Rodolfo Villamizar, P.E. Balcony #: 212 S Catwalk, 222 Elevator lobby Discipline: Special Threshold Type of Inspection:..: ' ' Partial -€final - °ew6peetkw Demolition Post Tension Lock Out Floor Slab (SOG) Reinforcing Steel Placement Floor Slab (SOG) Concrete Placement Elevated Slab Concrete Placement Elevated Slab Reinfor. Steel Placement Concrete Columns, Walls Reinf. Steel, Formwork, Embeds Concrete Placement for column(s) Cmu wall Erection/Placement, Fill Cell Rebar, Horiz J.R. Concrete Masonry Unit Fill Cell grouting Concrete Beam Reinf. Steel, Formwork, Embeds,.etc. Concrete Placement for Beam(s) Wall Sheathing, Blocking, Vapor Barriers, etc. Interior Framing and Firestopping Metal Floor Decking Metal Roof Decking Structural Steel Column(s) Erection Structural Steel Horizontal Framing Structural Steel Connections Wire Lath / Hock Lath Final etc. Attachments n Wall Framing & Glazing ural. Final (Use Additional member / Area Below) DISPOSITION OF INSPECTION (all pending inspections require a re -inspection) ❑Approved EX Approved as Noted l Pending Rejected ADDITIONAL INFORMATION ON MEMBER/AREA INSPECTED (From inspection items above): 212 S catwalk: Observed finished slab. 222 S catwalk: Observed in -progress concrete demolition of partial depth slab repairs. VERBAL INSTRUCTIONS: Contractor to continue partial depth slab repairs. ME 1VI Bel ENGINEERING, INC. MOIA BOWLS VILLAMIZAR & ASSOCIATES CIVIL• STRUCTURAL• SURVEYING • ENVIRONMENTAL STRUCTURAL INSPECTION REPORT Project Number: 15-320 Project Name: Treasure Cove Dunes 1835 20th Street. Vero Beach, FL 32960 772.569.0035 . Fax:772.778.3617 Inspection Date: 7/26/2017 www.mbveng.com C 93718 Weather: Sunny Owner: Treasure Cove Dunes Permit #: Bldg 2: SLC 1606-0391 Contractor: Daniello and Associates Inspector: Rodolfo Villamizar, P.E. Project Address: 4100 N A1A, Bldg 2 Qualified By: Rodolfo Villamizar, P.E. Balcony #: 212 S Catwalk Discipline: —Speda' Threshold Type of Inspection: Initial Partial FiRa1— —R mspest on Demolition Post Tension Lock Out Floor Slab (SOG) Reinforcing Steel Placement Floor Slab (SOG) Concrete Placement Elevated Slab Concrete Placement Elevated Slab Reinfor. Steel Placement Concrete Columns, Walls Reinf. Steel, Formwork, Embeds Concrete Placement for column(s) Cmu wall Erection/Placement, Fill Cell Rebar, HorizJ.R. Concrete Masonry Unit Fill Cell grouting Concrete Beam Reinf. Steel, Formwork, Embeds, etc. Concrete Placement for Beam(s) Wall Sheathing, Blocking, Vapor Barriers, etc. Interior Framing and Firestopping as Noted Metal Floor Decking Metal Roof Decking nStructural Steel Column(s) Erection I IStructural Steel Horizontal Framine Structural Steel Connections Wire Lath / Hock Lath nlnsulation Drywall, Type, Fastening, Rating, etc. Stucco Application In -Progress Stucco Application Final Exterior Veneers, Size, Type, Attachments Curtain Wall Framing & Glazing Structural Final X Other (Use Additional member/ Area Bek a re -inspection) Pending Rejected ADDITIONAL INFORMATION ON MEMBER/AREA INSPECTED (From inspection items above): Observed existing cracks along the slab edge. VERBAL INSTRUCTIONS: Contractor to repair crack per crack repair detail. 1 � CO P � N � INSPECTOR: Rodolfo Villamizar, P.E. 61000, 517021620 CERTIFIED By: Rodol o lllamiz r, P.E. 61000, 517021620 MBV ENGINEERING, INC. MOIA BOWLES VILLAMIZAR & ASSOCIATES CIVIL• STRUCTURAL• SURVEYING• ENVIRONMENTAL 1835 20th Street . Vero Beach, FL 32960 772.569.0035 . Fax:772.778.3617 www.mbveng.com CAK3)28 Owner: Treasure Cove Dunes STRUCTURAL INSPECTION REPORT Project Number: 15-320 Project Name: Treasure Cove Dunes Inspection Date: 7/13/2017 Weather: Sunny Permit #: Bide 2: SLC 1606-0391 Contractor: Daniello and Associates Inspector: Rodolfo Villamizar, P.E. Project Address: 4100 N A1A, Bldg 2 Qualified By: Rodolfo Villamizar, P.E. Balcony #: 211 Elevator Lobby & S Catwalk Discipline: Via' Threshold Type of Inspection: initial Partial —Final— ReWs e_t'._:: X Demolition Post Tension Lock Out Floor Slab (SOG) Reinforcing Steel Placement Floor Slab (SOG) Concrete Placement Elevated Slab Concrete Placement X Elevated Slab Reinfor. Steel Placement Concrete Columns, Walls Reinf. Steel, Formwork, Embeds Concrete Placement for column(s) Cmu wall Erection/Placement, Fill Cell Rebar, Horiz J.R. Concrete Masonry Unit Fill Cell grouting Concrete Beam Reinf. Steel, Formwork, Embeds, etc. Concrete Placement for Beam(s) Wall Sheathing, Blocking, Vapor Barriers, etc. Interior Framing and Firestopping Metal Floor Metal Roof Structural Steel Column(s) Erection Structural Steel Horizontal Framing Structural Steel Connections Wire Lath / Hock Lath Insulation Drywall, Type, Fastening, Rating, etc. Stucco Application In -Progress Stucco Application Final Exterior Veneers, Size, Type, Attachments I ICurtain Wall Framing & Glazing Structural Final Other (Use Additional member / Area DISPOSITION OF INSPECTION (all pending inspections require a re -inspection) Approved Approved as Noted X❑ Pending Rejected ADDITIONAL INFORMATION ON MEMBER/AREA INSPECTED (From inspection items above): Observed in -progress partial depth slab repairs; demolition extent, exposed rebar and PT -tendons. VERBAL INSTRUCTIONS: INSPECTOR: Rodolfo Villamizar, P.E. 61000, 517021620 ICERTIFIED BY: Rodo4/d UBkkhlihr, FI.E.$lobo. 517021620 I 6L N ED STRUCTURAL INSPECTION REPORT ENG IN EERI NG; IN(,St. Lucie CoVr% roJect Number: 15-320 M01ABQWLE5VIL1./iMIZAA &ASStlCIATES CIVIL x STRUCTURAL • SURVEYING • ENVIRONMENTAL 1835 20th Street. Vero Beach, FL.32960 772.56960035 ■ Fax: 772:778.3617 w. wwmbv4ang.com cA#3M Owner: Treasure Cove Dunes Contractor: Project Address: Project Name: Treasure Cove Dunes Inspection Date: 5/17/2017 Weather: Sunny Permit #: Daniello and Associates Inspector: 4100 N A1A, Bldg 2 qualified By: Bldg 2: SLC 1606-0391 Terence Schlitt, P.E. Rodolfo Villamizar, P.E. Balcony #: 211, 212, 222 Discipline: — Threshold Type of Inspection: Initial Partial Fil-i AeWspeetiGp Post Tension Lock Out Floor Slab (SOG) Reinforcing Steel Placement Floor Slab (SOG) Concrete Placement Elevated Slab Concrete Placement r Elevated Slab Reinfor. Steel Placement Concrete Columns, Walls Reinf. Steel, Formwork, Embeds _ Concrete Placement for column(s) _ Cmu wall Erection/Placement, Fill Cell_Rebar, Horiz J.R. Concrete Masonry Unit Fill Cell grouting Concrete Beam Reinf. Steel, Formwork, Embeds, etc. Concrete Placement for Beam(s) Wall Sheathing, Blocking, Vapor Barriers, etc. as Noted ADDITIONAL INFORMATION ON VERBAL INSTRUCTIONS: Metal Floor Decking Metal Roof Decking Structural Steel Column(s) Erection Structural Steel Horizontal Framing Structural Steel Connections Wire Lath / Hock Lath Insulation Drywall, Type, Fastening, Rating, etc. Stucco Application In -Progress Stucco Application Final Exterior Veneers, Size, Type, Attachments re a re-inspe( ❑ Pending i Wall Framing & Glazing ual Final (Use Additional member/Area Lion) Rejected inspection items above): Mill 610n0 �C)T,�. STATE OF 0, I'-(r%I 7y�/7 �i(n'• c<0 INSPECTOR: Terence Schlitt. P.E. 81238 CERTIFIE6* � * 'ap% P.. 10 0, SI7021620 Irrrnni��� ®mmMBV' ENGINEERING, INC. MOIA BOWLESVILLAMIZA &ASSOCIATES CIVIL. STRUCTURAL• SURVEYING . ENVIRONMENTAL STRUCTURAL INSPECTION REPORT Project Number: 15-320 Project Name: Treasure Cove Dunes 1835 20th Street. Vero Beach, FL 32960 772.SM0035 . Fax: 772t778.3,617 Inspection Date: 6/14/2017 www.mbveng.com �g3J Weather: Sunny Owner: Treasure Cove Dunes Permit #: Bldg 2: SLC 1606-0391 Contractor: Daniello and Associates Inspector: Terence Schlitt, P.E. Project Address: 4100 N A1A, Bldg 2 Qualified By: Rodolfo Villamizar, P.E. Balcony #: 211, 212, 222 Discipline: —Sp.�l— Threshold Type of Inspection: Initial Partial Final °ei;,ap %fiGI4 'ost Tension Lock Out loor Slab (SOG) Reinforcing Steel Plac_emer loor Slab (SOG) Concrete Placement levated Slab Concrete Placement levated Slab Reinfor. Steel. Placement Concrete Columns, Walls Reinf. Steel, Formwork, Embeds Concrete Placement for column(s) Cmu wall Erection/Placement, Fill Cell Rebar,_Ho_riz J.R. Concrete -Masonry Unit Fill Cell grouting Concrete Beam Reinf. Steel, Formwork, Embeds, etc. Concrete Placement for Beam(s) Wall Sheathing, Blocking, Vapor Barriers,. etc. Interior Framing and Firestopping Metal Floor Decking Metal Roof Decking Structural Steel Column(s) Erection Structural Steel Horizontal Framing Structural Steel Connections Wire Lath / Hock Lath Insulation Drywall, Type, Fastening, Rating, etc. Stucco Application In -Progress Stucco Application Final Exterior Veneers, Size, Type, Attachments Curtain Wall Framing &'Glazing Structural Final Other (Use -Additional member / Area Below) as Noted I I Pending INFORMATION ON MEMBER/AREA INSPECTED (From inspection items VERBAL INSTRUCTIONS: NOTES: Rejected 7% O i i�1StSORID � INSPECTOR: Terence Schlitt. P.E. 81238 CERTIFIED BY: i $m , P.E. 6100 , SI 7021620