Loading...
HomeMy WebLinkAboutREVIEW COMMENTSPlanning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982. Phone:(772)462-2172 Fax:(772)462.6443 REVIEW COMMENTS SIL ANNED BY St. Li iri Q rnnn PROPERTY INFORMATION Address: 14191 Rangeline Rd Owner(s): Port St Lucie City OF City / State / Zip: Port St Lucie, FI 34987 Parcel #: 4233-111-0001-00016 Jurisdiction: SAINT LUCIE COUNTY Zoning: AG-5 Lot#: Block: APPLICATION INFORMATION Permit Number: 1607-0157 Stories: Automatic Sprinkler System? No Permit Type: UTILITY CONTRACTOR INFORMATION Contractor Name: Thomas J Carrick Fax Number: 561-844-5641 Business Name: Carrick Contracting Corporation Email: Lwatts@Canickcontracting. Business Addr: 1450 Kinetic Rd Ste A Com City / State / Zip: Lake Park, FI 33403 REVIEWS AND COMMENTS Review Type Stabjfi Reviewed By Date Started Date Completed Date Released ADDRESSING ASSIGNMENT COMPLETE Lydia Galbraith 711412016 7/15/2016 7/1512016 Comment: DOCUMENTS MISSING PENDING Audrey Humphrey 71812016 7/8/2016 Comment: NEEDS AN ELECTRICAL SUB AGREEMENT AND SUB SUMMARY. FRONT COUNTER REVIEW COMPLETE Audrey Humphrey 7/8/2016 7/8/2016 7/812016 Comment: PE REVIEW COMMENTS (2) INCOMPLETE Joe Cicio 81312016 Comment: ALL PLANS MUST BE DESIGNED TO THE 2014 FLORIDA BUILDING CODES AND TIA-222 AS DEFINED IN FBC 7/20/2016 3108 NOT THE 2009 IBC' DESIGN PROFESSIONAL TO NOTE ALL DESIGN CODES ON PLANS Comment: SUBMIT [ 2 ] ST LUCIE COUNTY "CERTIFICATION FOR DESIGN LOAD COMPLIANCE "SHEETS COMPLETELY FILLED OUT AND SIGNED, SEALED AND DATED BY THE DESIGN PROFESSIONAL OF RECORD 7/20/2016 • ALL P.E.SEALS AND SIGNATURES MUST BE IN ORIGINAL FORMAT' THESE BLANK DOCUMENTS ARE AVAILABLE ON THE SY LUCIE COUNTY WEBSITE Comment: THIS RISK CAT III STRUCTURE MUST BE DESIGNED TO 168 MPH WINDSPEED / EXPOSURE C NOT 130 MPH 7/20/2016 ' SEE FBC 1609E FIGURE Comment: PAGE 2 OF 41 FOUNDATION NOTES ] WE ARE CURRENTLY ENFORCING ACI-318 2011 [ NOT 2008 ] DESIGN 7/20/2016 PROFESSIONAL TO MODIFY PLAN NOTES Comment: SUBMIT A PLAN OVERVIEW AS TO THE LOCATIONS OF THE FOUNDATIONS /PLANS ARE NOT CLEAR AS 7/20/2016 TO WHICH FOUNDATIONS ARE LOCATED' ELIMINATE ANY ALTERNATIVES FROM PLANS Comment: FAG 61 G15-23 REQUIRES THE ENGINEER TO FOLLOW CERTAIN CRITERIA' SEE NOTE [ 2 ] (3) NOTES 1-41 7/20/2016 [ 3 ] (A) FOR THE ENGINEERS TITLE BLOCK - Comment: SUBMIT AN ENGINEERED ELECTRICAL PLAN FOR THE REVIEWER IN ACCORDANCE WITH THE 2011 NEC / 7/20/2016 SHOW ALL RINGS, CAD WELDING AND REQUIRED BONDING PER CODE / NOT IN PACKAGE' CANNOT REVIEW AT THIS TIME Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone•.(772)462.2172 Fax:(772[462-6443 REVIEW COMMENTS 2 7/20/2016 Comment: PLS RE -SUBMIT PLANS IN ORIGINAL, SIGNED, SEALED AND DATED FORMAT [ DUPLICATE ] FOR RE - REVIEW 8/3/2016 Comment: ADDITIONAL REVIEW COMMENTS BASED UPON THE RE -SUBMITTED PLANS FROM AMEC FOSTER WHEELER DATED 5/20/2016 8/3/2016 Comment: WE WILL NEED A SEPARATE PERMIT APPLICATION FOR THE EQUIPMENT SHELTER WITH THE STATE APPROVED DOCUMENTS IN TRIPLICATE' FOUNDATIONS ARE ON MAIN PLANS 8/3/2016 Comment: PLEASE SUBMIT A SEPARATE PERMIT FOR THE FENCE W/ PLANS 8/3/2016 Comment: PLEASE SUBMIT A SEPARATE PERMIT FOR THE FUEL TANK SYSTEM' FOUNDATION IS ON MAIN PLANS 8/3/2016 Comment: PLEASE SUBMIT A PERMIT FOR THE GENERATOR W/ MANUFACTURERS SPECIFICATIONS AND TIE DOWNS " FOUNDATION SPECS ARE IN MAIN PLANS 8/3/2016 Comment: PLEASE SUBMITA SEPARATE PERMIT FOR THE ICE BRIDGE " PLANS ARE WITHIN THE MAIN PLANS 8/3/2016 Comment: NOTE: ALL ENGINEERS OR ARCHITECTS SEALS MUST BE IN ORIGINAL FORMAT THEN SIGNED AND DATED OVER SEAL `ALL SEALS SHALL BE A MIN OF 1 & 7/8" IN DIAMETER 8/3/2016 Comment: COMMENTS E-MAILED TO MOTOROLA AND CONTRACTOR AS OF THIS DATE PLANS EXAMINER REVIEW COMPLETE Joe Ciclo 7/2012016 81312016 8/312016 Comment: ZONING REVIEW INCOMPLETE Linda Pendarvis 7/1212016 7/15/2016 Comment: THE GENERATOR AND GAS TANK REQUIRE A SEPARATE,PERMIT APPLICATION. THE SUBMITTED APPLICATION WILL ONLY BE FOR THE TOWER. Comment: PLEASE BE AWARE THAT THE TOWER REQUIRES AN APPROVED SITE PLAN FROM THE PLANNING DIVISION. THEREFOR WE WERE NOT ABLE TO COMPLETE THE ZONING REVIEW. THE PERMIT WILL 7/15/2016 PROCEED THRU THE PERMITTING PROCESS BUT WILL NOT BE ISSUED UNTIL WE HAVE RECEIVED THE SITE PLAN APPROVAL AND ZONING HAS BEEN ABLE TO FINALIZE THE REVIEW. OUR PLANNING MANAGER WILL INFORM CRAIG MONTGOMERY OF THE REQUIRED SITE PLAN APPROVAL. 7/15/2016 Comment: PLEASE BE AWARE THAT ADDITIONAL ZONING REVIEW COMMENTS MIGHT BE APPLICABLE AFTER SITE PLAN APPROVAL HAS BEEN RECEIVED. 7/15/2016 Comment: ABOVE COMMENTS ONLY REFLECT THE ZONING REVIEW COMMENTS. THE PLANS EXAMINER MIGHT HAVE ADDITIONAL COMMENTS. n JG. �ErG1Ci UOviav�az Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:V72)462.2172 Fax:(772)462-6443 PROPERTY INFORMATION Address: 14191 Rangeline Rd City / State / Zip: Port St Lucie, FI 34987 Parcel#: 4233-111-0001-00016 Zoning: AG-5 APPLICATION INFORMATION Permit Number: 1607-0157 Permit Type: UTILITY REVIEW COMMENTS SCANNED BY St. Lucie County Page 1 Owner(s): Port St Lucie City OF Jurisdiction: SAINT LUCIE COUNTY Lot#: Stories: Contractor Name: Thomas J Carrick Business Name: Carrick Contracting Corporation Business Addr: 1450 Kinetic Rd Ste A City / State / Zip: Lake Park, FI 33403 REVIEWS AND COMMENTS Review Tvoe Status Reviewed By ADDRESSING ASSIGNMENT COMPLETE Lydia Galbraith Comment: DOCUMENTS MISSING 7/8/2016 Comment: FRONT COUNTER REVIEW Comment: PLANS EXAMINER REVIEW 7/20/2016 Comment: Comment: 7/2012016 7/20/2016 Comment: 7/20/2016 Comment: 7/20/2016 Comment: 7/20/2016 Comment: 7/20/2016 Comment: Block: Automatic Sprinkler System? No Fax Number: 561-844-5641 Email: Lhaylett@Cardckcontracting .Com Dale Started Dale Completed Date Released 7/1412016 7/1512016 7/1512016 PENDING Audrey Humphrey 7/8/2016 NEEDS AN ELECTRICAL SUB AGREEMENTAND SUB SUMMARY. COMPLETE Audrey Humphrey 7/8/2016 718/2016 7/812016 INCOMPLETE Joe Clcio 7/20/2016 ALL PLANS MUST BE DESIGNED TO THE 2014 FLORIDA BUILDING CODES AND TIA-222 AS DEFINED IN FBC 3108 NOT THE 2009 IBC • DESIGN PROFESSIONAL TO NOTE ALL DESIGN CODES ON PLANS SUBMIT [2) ST LUCIE COUNTY - CERTIFICATION FOR DESIGN LOAD COMPLIANCE' SHEETS COMPLETELY FILLED OUT AND SIGNED, SEALED AND DATED BY THE DESIGN PROFESSIONAL OF RECORD ALL P.E.SEALS AND SIGNATURES MUST BE IN ORIGINAL FORMAT • THESE BLANK DOCUMENTS ARE AVAILABLE ON THE SY LUCIE COUNTY WEBSITE SUBMIT AN ORIGINAL SIGNED, SEALED AND DATED SOIL REPORT DATED 05/10/2016 FOR REVIEW FBC 107.1 THIS RISK CAT III STRUCTURE MUST BE DESIGNED TO 168 MPH WINDSPEED / EXPOSURE C NOT 130 MPH SEE FBC 1609E FIGURE PAGE 2 OF 4 [ FOUNDATION NOTES ) WE ARE CURRENTLY ENFORCING ACI-318 2011 [ NOT 20081 DESIGN PROFESSIONAL TO MODIFY PLAN NOTES SUBMIT A PLAN OVERVIEW AS TO THE LOCATIONS OF THE FOUNDATIONS / PLANS ARE NOT CLEAR AS TO WHICH FOUNDATIONS ARE LOCATED • ELIMINATE ANY ALTERNATIVES FROM PLANS FAC 61G15-23 REQUIRES THE ENGINEER TO FOLLOW CERTAIN CRITERIA. SEE NOTE [ 21 (B) NOTES 1-4! [31 (A) FOR THE ENGINEERS TITLE BLOCK Planning & Development Services Building & Code Regulation. Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Fax:(772]462.6443 REVIEW COMMENTS Comment: SUBMIT AN ENGINEERED ELECTRICAL PLAN FOR THE REVIEWER IN ACCORDANCE WITH THE 2011 NEC / 7/2012016 SHOW ALL RINGS, CAD WELDING AND REQUIRED BONDING PER CODE / NOT IN PACKAGE • CANNOT REVIEW AT THIS TIME 7/20/2016 Comment: PLS RE -SUBMIT PLANS IN ORIGINAL, SIGNED, SEALED AND DATED FORMAT [ DUPLICATE ] FOR RE - REVIEW ZONING REVIEW INCOMPLETE Linda Pendarvis 7/12/2016 7/15/2016 Comment: THE GENERATOR AND GAS TANK REQUIRE A SEPARATE PERMIT APPLICATION. THE SUBMITTED APPLICATION WILL ONLY BE FOR THE TOWER. Comment: PLEASE BE AWARE THAT THE TOWER REQUIRES AN APPROVED SITE PLAN FROM THE PLANNING DIVISION. THEREFOR WE WERE NOTABLE TO COMPLETE THE ZONING REVIEW. THE PERMIT WILL 711512016 PROCEED THRU THE PERMITTING PROCESS BUT WILL NOT BE ISSUED UNTIL WE HAVE RECEIVED THE SITE PLAN APPROVAL AND ZONING HAS BEEN ABLE TO FINALIZE THE REVIEW. OUR PLANNING MANAGER WILL INFORM CRAIG MONTGOMERY OF THE REQUIRED SITE PLAN APPROVAL. 711512016 Comment: PLEASE BE AWARE THAT ADDITIONAL ZONING REVIEW COMMENTS MIGHT BE APPLICABLE AFTER SITE PLAN APPROVAL HAS BEEN RECEIVED. 7/15/2016 Comment: ABOVE COMMENTS ONLY REFLECT THE ZONING REVIEW COMMENTS. THE PLANS EXAMINER MIGHT HAVE ADDITIONAL COMMENTS. 1 �opmentServices REVIEW COMMENTS egulation Division Avenue1Tz __ _ REM'.' :D JUL 2 72016 � aal3s PROPERTY INFORMATION Address: 14191 Rangeline Rd City / State / Zip: Port St Lucie, FI 34987 Parcel #: 4233-111-0001-000/6 Zoning: AG-5 APPLICATION INFORMATION Permit Number: 1607-0157 Permit Type: Contractor Name: UTILITY Thomas J Carrick 5(:HNIVED BY St. Lucie County 1 Owner(s): Port St Lucie City OF Jurisdiction: SAINT LUCIE COUNTY Lot#: Stories: Business Name: Carrick Contracting Corporation Business Addr: 1450 Kinetic Rd Ste A City / State / Zip: Lake Park, FI 33403 REVIEWS AND COMMENTS Review Tvpe Status Reviewed By ADDRESSING ASSIGNMENT COMPLETE Lydia Galbraith Comment: DOCUMENTS MISSING 7/8/2016 Comment: FRONT COUNTER REVIEW Comment: PLANS EXAMINER REVIEW 7/20/2016 Comment: Comment: 7/2012016 7/20/2016 Comment: 7/2012016 Comment: 7/2012016 Comment: 7/20/2016 Comment: 7/20/2016 Comment: Block: Automatic Sprinkler System? No Fax Number: 561-844-5641 Email: Lwatts@Carrickeontracting. Corn Date Started 7/14/2016 PENDING Audrey Humphrey 71812016 NEEDS AN ELECTRICAL SUB AGREEMENT AND SUB SUMMARY. COMPLETE Audrey Humphrey 71812016 INCOMPLETE Joe Cicio 712012016 Date Completed Date Released 7/15/2016 7/15/2016 71812016 71812016 ALL PLANS MUST BE DESIGNED TO THE 2014 FLORIDA BUILDING CODES AND TIA-222 AS DEFINED IN FBC 3108 NOT THE 2009 IBC' DESIGN PROFESSIONAL TO NOTE ALL DESIGN CODES ON PLANS SUBMIT [ 21 ST LUCIE COUNTY " CERTIFICATION FOR DESIGN LOAD COMPLIANCE " SHEETS COMPLETELY FILLED OUT AND SIGNED, SEALED AND DATED BY THE DESIGN PROFESSIONAL OF RECORD `ALL P.E.SEALS AND SIGNATURES MUST BE IN ORIGINAL FORMAT' THESE BLANK DOCUMENTS ARE AVAILABLE ON THE SY LUCIE COUNTY WEBSITE SUBMIT AN ORIGINAL SIGNED, SEALED AND DATED SOIL REPORT DATED 05110/2016 FOR REVIEW FBC 107.1 THIS RISK CAT III STRUCTURE MUST BE DESIGNED TO 168 MPH WINDSPEED / EXPOSURE C NOT 130 MPH ' SEE FBC 1609E FIGURE PAGE 2 OF 4 [ FOUNDATION NOTES 1 WE ARE CURRENTLY ENFORCING ACI-318 2011 [ NOT 20081 DESIGN PROFESSIONAL TO MODIFY PLAN NOTES SUBMIT A PLAN OVERVIEW AS TO THE LOCATIONS OF THE FOUNDATIONS / PLANS ARE NOT CLEAR AS TO WHICH FOUNDATIONS ARE LOCATED' ELIMINATE ANY ALTERNATIVES FROM PLANS FAC 61 G15-23 REQUIRES THE ENGINEER TO FOLLOW CERTAIN CRITERIA' SEE NOTE [ 21 (B) NOTES 1-4 I [ 31 (A) FOR THE ENGINEERS TITLE BLOCK / REVIEW COMMENTS SCANNED St. Luc a Countv 2 Comment: SUBMIT AN ENGINEERED ELECTRICAL PLAN FOR THE REVIEWER IN ACCORDANCE WITH THE 2011 NEC / 7/20/2016 SHOW ALL RINGS, CAD WELDING AND REQUIRED BONDING PER CODE / NOT IN PACKAGE `CANNOT REVIEW AT THIS TIME 7/20/2016 Comment: PLS RE -SUBMIT PLANS IN ORIGINAL, SIGNED, SEALED AND DATED FORMAT I DUPLICATE ] FOR RE - REVIEW ZONING REVIEW INCOMPLETE Linda Pendarvis 7/1212016 7/1512016 Comment: THE GENERATOR AND GAS TANK REQUIRE A SEPARATE PERMIT APPLICATION. THE SUBMITTED APPLICATION WILL ONLY BE FOR THE TOWER. Comment: PLEASE BE AWARE THAT THE TOWER REQUIRES AN APPROVED SITE PLAN FROM THE PLANNING DIVISION. THEREFOR WE WERE NOT ABLE TO COMPLETE THE ZONING REVIEW. THE PERMIT WILL 7/1512016 PROCEED THRU THE PERMITTING PROCESS BUT WILL NOT BE ISSUED UNTIL WE HAVE RECEIVED THE SITE PLAN APPROVAL AND ZONING HAS BEEN ABLE TO FINALIZE THE REVIEW. OUR PLANNING MANAGER WILL INFORM CRAIG MONTGOMERY OF THE REQUIRED SITE PLAN APPROVAL. 7/1512016 Comment: PLEASE BE AWARE THAT ADDITIONAL ZONING REVIEW COMMENTS MIGHT BE APPLICABLE AFTER SITE PLAN APPROVAL HAS BEEN RECEIVED. 7/1512016 Comment: ABOVE COMMENTS ONLY REFLECT THE ZONING REVIEW COMMENTS. THE PLANS EXAMINER MIG T HAVE ADDITIONAL COMMENTS. G •XWOLQ SG) 1607 1ois7 4/"E v �S ��yE r02 — M�� • s o C,S .s6AL5 — /nc/ST $e e�/3;p-xo 044 — NO a ap/1BD qt2 qNy 333