HomeMy WebLinkAboutPROJECT INFORMATIONR Y-+ M L Engineering, Inc. Consulting Engineers 2030 37" Avenue SCNN�Vt1J Vero Beach, Florida 32960 BY Phone (772) 569-1257 Fax (772) 5694041 St. LUCI2 County mlengineeringinc.com Project No. 16-175 Report No. 1 cc: Gene Ross Elliott Merrill Bob Stark Structure -Con. Carl Peterson SLC Bldg Dept File OCEAN HARBOR SOUTH CONDOMINIUMS CONCRETE REPAIRS 4250 NORTH HIGHWAY AIA, FT. PIERCE, FLORIDA THRESHOLD INSPECTION REPORT SLC BUILDING PERMIT NUMBER: 1608-0114 PROJECT NAME: Ocean Harbor South Bldg A DATE: October 3, 2016 CLIENT: Elliott Merrill Community Mgt. LOCATION: Ft. Pierce, Florida CONTRACTOR: Structure -Con PROJECT MGR: Khris McConnell INSPECTED BY: Mike Luc WEATHER: Overcast slight rain WORK INSPECTED: Building A — North Building Balcony repairs — Unit 508 Demolition of the concrete was observed at several locations which included the following: 1. Surface repair along the exterior at the south sliding glass door. This appeared to be loose decorative topping on a previously repaired area and no structural damage to the slab. 2. Slab edge of the south facing balcony. There was some corrosion of the reinforcing and no post tension cables are affected, repair as per the documents 3. Full depth repair in the middle of the slab on the south side. This was caused by a corroded post tension splice coupler that was not encapsulated or taped. The coupler should be mechanically cleaned, coated with a corrosion inhibitor and wrapped with a PVC tape. Do not excavate any further behind the bearing end of the anchor. 4. Column repair at the north end. There is corrosion of the reinforcing at the bottom of the column which extends down into the columns. Further excavation into the slab is required to repair the column as per the documents. Re-inspedt prior to concrete placement. M L Engineering, Inc. Consulting Engineers 2030 37' Avenue Vero Beach, Florida 32960 Phone (772) 569-1257 Fax (772) 569-4041 mlengineeringinc.com Project No. 16-175 Report No. 1 cc: Gene Ross Elliott Merrill Bob Stark Structure -Con. Carl Peterson SLC Bldg Dept File 2 M L Engineering, Inc. Consulting Engineers 2030 37' Avenue Vero Beach, Florida 32960 Phone (772) 569-1257 Fax (772)569-4041 C mlengineeringinc.com JVHIV _ NED Project No. 16-175 Report No. 2 cc: Gene Ross Elliott Merrill Bob Stark Structure -Con. Carl Peterson SLC Bldg Dept File OCEAN HARBOR SOUTWCOl"' S CONCRETE REPAIRS 4250 NORTH HIGHWAY AlA, T. PIERCE, FLORIDA THRESHOLD INSPECTION REPORT SLC BUILDING PERMIT NUMBER: 1608-0114 PROJECT NAME: Ocean Harbor South Bldg A CLIENT: Elliott Merrill Community Mgt. CONTRACTOR: Structure -Con INSPECTED BY: Mike Lue WORK INSPECTED: Building A — North Building Balcony repairs DATE: October 14, 2016 LOCATION: Ft. Pierce, Florida PROJECT MGR: Khris McConnell WEATHER: Overcast slight rain Unit 208 1. There are 3 post tension cables that Be completely corroded and broken in the upper surface of the balcony slab. The pt anchors at the balcony edge are set back in about 12 inches from the slab edge with no pockets. The cables appear to have been tensioned from the other end of the building on the west side. 2. The anchors on the west elevation are to be located and the cables replaced. The slab should be shored when excavating the balcony slab to place the new section of cable. Unit 508 1. The reinforcing and post tension splice coupler have been coated and taped and are approved for concrete placement at the repair areas. 2. Anchors for the shutter track and guard rail clip should be 1 maximum in length to avoid the possibility of damaging pt cables or touching the column reinforcing. Unit 808 1. There is a large ceiling spall at the underside of the 908 slab above that requires repair that was not on our original list. The two 2 sq ft surface spalls on the list do not require repairs. The edge crack on the southern edge needs as well as the column at the north side needs excavation and repair. Unit 1001 1. The spall at the door threshold has been excavated and found to be loose topping. The concrete needs to be chipped down further to allow a minimum repair mortar thickness of about 3/8" for adequate bonding. 2. Concrete has been chipped out at the edge spalls on the north and east balcony edges. There are 2 pt anchors on the east and 1 pt anchor on the north balcony edge. There is some corrosion of the pt anchors and bursting bars. The existing reinforcing bars perpendicular to the slab edges were too long and are corroded. 3. Continue cleaning the concrete from the top of the bursting bars just enough to verify if the extent of corrosion and without affecting the live anchors. M L Engineering, Inc. Project No. 16-175 Report No. 2 Consulting Engineers cc: Gene Ross Elliott Merrill 2030 37ih Avenue Bob Stark Structure -Con. Vero Beach, Florida 32960 Carl Peterson SLC Bldg Dept Phone (772) 569-1257 File Fax (772)569-4041 mlengineeringinc.com 4. If there is less than 20% loss of section, the bars and anchors can remain and repaired, if not, the cables are to be locked off, de -stressed and replaced per the specs. Pic 2 Unit 208 Anchors of the three cables at the balcony edge Note how that these anchors are set back in from the slab edge, and cables may have been pulled from the other end. 2 ti M L Engineering, Inc. Consulting Engineers 2030 37" Avenue Vero Beach, Florida 32960 Phone (772) 569-1257 Fax (772) 569AO41 mlengineeringino.com Project No. 16-175 Report No. 2 cc: Gene Ross Elliott Merrill Bob Stark Structure -Con. Carl Peterson SLC Bldg Dept File Pic 3 Unit 508 Bars coated and ready for concrete repair mortar Pic 5 Unit 1001 East balcony edge Two corroded pt anchors and bursting bars. Note the ends of the cables are too long and not encapsulated back. r 1 , M L Engineering, Inc. Consulting Engineers 203037' Avenue SCANNED Vero Beach, Florida 32960 Phone (772) 569-1257 BY Fax (772) 41 St. Lucie County mlengineeringinc.cginc.com Project No. 16-175 Report No. 3 cc: Gene Ross Elliott Merrill Bob Stark Structure -Con. Cart Peterson SLC Bldg Dept File OCEAN HARBOR SOUTH CONDOMINIUMS CONCRETE REPAIRS 4250 NORTH IHG14WAY AIA, FT. PIERCE, FLORIDA THRESHOLD INSPECTION REPORT SLC BUILDING PERMIT NUMBER: 1608-0114 PROJECT NAME: Ocean Harbor South Bldg A CLIENT: Elliott Merrill Community Mgt. CONTRACTOR: Structure -Con INSPECTED BY: Mike Lue WORK INSPECTED: Building A — North Building Balcony repairs DATE: October 26, 2016 LOCATION: Ft. Pierce, Florida PROJECT MGR: Khris McConnell WEATHER: Overcast slight rain Unit 1001 1. The spall at the door threshold has been repaired. 2. Concrete has been chipped out at the edge spalls on the north and east balcony edges. The reinforcing and pt anchors have been cut back, cleaned and coated with corrosion inhibitor on the east edge. Remove the excess paint from the anchor insert to allow the greased end caps to be placed. 3. The anchor and reinforcing is slightly high in the slab but they cannot be moved deeper in to the slab unless other unaffected bars are removed. Clean the reinforcing bars and anchors and repair the cable end and concrete. 4. There is an area of approximately 9 sq feet of ceiling and edge spall at the northeast corner. This may require locking off at least one cable at the north edge. Contractor to verify if there are other cables along the adjacent east prior to chipping out the concrete. Unit 1006 5. Check for additional surface spall at balcony edge. l M L Engineering, Inc. Consulting Engineers 2030 37 ° Avenue Vero Beach, Florida 32960 Phone (772) 569-1257 Fax (772) 5694041 mlengineeringinc.com Project No. 16-175 Report No. 3 cc: Gene Ross Elliott Merrill Bob Stark Structure -Con. Carl Peterson SLC Bldg Dept File Pic I Unit 1001 East edge repair Pic 2 Unit 1001 North edge repair Anchor and bursting bar is close to surface 2 M L Engineering, Inc. Consulting Engineers 2030 37 ° Avenue Vero Beach, Florida 32960 Phone (772) 569-1257 Fax (772)569-4041 mlengineeringinc. com Project No. 16-175 Report No. 3 cc: Gene Ross Elliott Merrill Bob Stark Structure -Con. Cart Peterson SLC Bldg Dept File a M L Engineering, Inc. Consulting Engineers 2030 371° Avenue Vero Beach, Florida 32960 Phone (772) 569-1257 Fax (772)569-4041 mlengineeringino.com SCANNED BY St Lucie County Project No. 16-175 Report No. 4 cc: Gene Ross Elliott Merrill Bab Stark Structure -Con. Carl Peterson SLC Bldg Dept File OCEAN HARBOR SOUTH CONDOMINIUMS CONCRETE REPAIRS 4250 NORTH HIGHWAY AIA, FT. PIERCE, FLORIDA THRESHOLD INSPECTION REPORT SLC BUILDING PERMIT NUMBER: 1608-0114 PROJECT NAME: Ocean Harbor South Bldg A CLIENT: Elliott Merrill Community Mgt. CONTRACTOR: Structure -Con INSPECTED BY: Mike Lue WORK INSPECTED: Building A —North Building Balcony repairs DATE: November 11, 2016 LOCATION: Ft. Pierce, Florida PROJECT MGR: Khris McConnell WEATHER: Sunny Unit 808 1. The ceiling spalls have been excavated and all corroded reinforcing bars exposed. The corrosion has been chased and all bars have been cleaned, primed and ready for pour. The total area of ceiling repair is 19 square feet. 2. The edge crack at the southern edge needs excavation and repair. Unit 1001 1. The northern slab edge has been excavated and one pt cable has been locked off. The existing reinforcing bars have been cleaned, primed and ready for pour. The total area is 5 linear feet. 2. The northeast slab edge comer is in progress. One pt cable was discovered and will require locking off prior to further excavating. Unit 1101 1. The northeast corner has been excavated and one pt cable locked off. The existing reinforcing bars have been cleaned and primed. The end of one bar running in the north to south direction will require cutting to provide an edge clearance of 1 '/2". The total area of repair is 4 linear feet of edge and 2 square feet of full depth. All splice couplers shall be encapsulated in PVC or taped to prevent corrosion. 1 1 M L Engineering, Inc. Consulting Engineers 203037' Avenue Vero Beach, Florida 32960 Phone (772) 569-1257 Fax (772) 5694041 mlengineeringine.com Project No.16-175 Report No. 4 cc: Gene Ross Elliott Merrill Bob Stark Structure -Con. Carl Peterson SLC Bldg Dept File `A 1. M L Engineering, Inc. Consulting Engineers 2030 37" Avenue Vero Beach, Florida 32960 Phone(772) 569-1257 Fax (772) 5694041 mlengineeringine.com Project No. 16-175 Report No. 4 cc: Gene Ross Elliott Merrill Bob Stark Structure -Con. Carl Peterson SLC Bldg Dept File M L Engineering, Inc. Consulting Engineers 2030 371h Avenue Vero Beach, Florida 32960 Phone (772) 569-1257 CM Fax (772)569-4041 I ED mlengineeringinc.com B St Curio n__ Project No. 16-175 Report No. 5 cc: Gene Ross Elliott Merrill Bob Stark Structure -Con. Carl Peterson SLC Bldg Dept File OCEAN HARBOR SOUTH CONDOMYV@ft CONCRETE REPAIRS 4250 NORTH HIGHWAY AlA, FT. PIERCE, FLORIDA THRESHOLD INSPECTION REPORT SLC BUILDING PERMIT NUMBER: 1608-0114 PROJECT NAME: Ocean Harbor South Bldg A CLIENT: Elliott Merrill Community Mgt. CONTRACTOR: Structure -Con INSPECTED BY: Mike Lue WORK INSPECTED: Building A — North Building Balcony repairs DATE: November 22, 2016 LOCATION: Ft. Pierce, Florida PROJECT MGR: Khris McConnell WEATHER: Sunny Unit 208 1. The 3 post tension cables have been spliced and replaced from inside the unit east to the balcony edge. The new anchors were placed all the way out to the edge so they can be stressed. Provide 2 #4 bursting bars behind the anchors at the slab edge. Bars need to be epoxy anchored in the middle of the slab. Since the slab is only about 4 to 5 inches thick the bars should be offset and should not be aligned vertically. 2. There were existing splices in the same 3 cables which had to be excavated to so that the new cables can be tensioned. 3. Tape all exposed post tension cables and connections. Unit 1001 1. Concrete repair needed at NE corner of balcony. There is one pt cable that had to be locked off and will require to be spliced and re -tensioned. 2. The repair to the cable at the north edge has been completed. Cable spliced, re -tensioned and encapsulated, ready for concrete repair mortar. Unit 1101/1001 1. The 2 cables at NE corner of the 1101 floor slab (1001 ceiling) have been repaired, re - tensioned and first concrete pour completed. The second pour is now ready. All splice couplers shall be encapsulated in PVC or taped to prevent corrosion. _ 1 M L Engineering, Inc. Consulting Engineers 2030 37' Avenue Vero Beach, Florida 32960 Phone (772) 569-1257 Fax (772) 569AO41 mlengineeringinc.com Project No. 16-175 Report No. 5 cc: Gene Ross Elliott Merrill Bob Stark Structure -Con. Cart Peterson SLC Bldg Dept File 2 M L Engineering, Inc. SCProject No. 16-175 Report No. 6 Consulting Engineers cc: Gene Ross Elliott Merrill 2030 3r Avenue BY Bob Stark Structure -Con. Vero Beach, Florida 32960 Carl Peterson SLC Bldg Dept Phone (772) 569-1257 St. Lucie Count, File Fax (772) 569AO41 ralengineeringinc.com OCEAN HARBOR SOUTH CONDOMINIUMS CONCRETE REPAIRS 4250 NORTH HIGHWAY ALA, FT. PIERCE, FLORIDA THRESHOLD INSPECTION REPORT SLC BUILDING PERMIT NUMBER: 1608-0114 PROJECT NAME: Ocean Harbor South Bldg A DATE: December 5, 2016 CLIENT: Elliott Merrill Community Mgt. LOCATION: Ft. Pierce, Florida CONTRACTOR: Structure -Con PROJECT MGR: Khris McConnell INSPECTED BY: Mike Lue WEATHER: Sunny WORK INSPECTED: Building A — North Building Balcony repairs Unit 208 1. The 3 post tension cables have been spliced and replaced from inside the unit east to the balcony edge. The new anchors were placed all the way out to the edge so they can be stressed. Concrete around the anchors have been poured and cables stressed. 2. The three splice couplers have been taped. The cable ends need to be cut shorter with a torch so that the greased end caps can be placed and properly grouted. The concrete can be poured around the splice couplers at the door sill. All anchors for the re- installation of the door track shall be stainless steel anchors in holes sealed with a polyurethane sealant with a maximum embedment of 1" so as to avoid damaging pt cables Unit 1001 1. The one pt cable has been locked off and spliced. 2. Provide a 90 degree corner lap bar with 12 inch legs each way to tie the edge bars. Raise the bursting bars and corner bar for proper concrete coverage. Pour concrete and re -tension once the concrete has achieved a minimum of 3500 psi r M ,~44 M L Engineering, Inc. Consulting Engineers 2030 371 Avenue Vero Beach, Florida 32960 Phone (772) 569-1257 Fax (772)569-4041 mlengineeringinc.com Project No. 16-175 Report No. 6 cc: Gene Ross Elliott Merrill Bob Stark Structure -Con. Carl Peterson SLC Bldg Dept File Pic 3 Unit 1001 Pt cable splice and ready for concrete pour before re -stressing cable Note the bottom bars at the corner and under the anchor needs to be raised up to provide the proper concrete coverage Provide a 90 degree #4 corner lap bar. 2 M L Engineering, Inc. Consulting Engineers 2030 3r Avenue Vero Beach, Florida 32960 Phone (772) 569-1257 Fax (772)569-4041 mlengineeringine.mm SLAMMED BY St. Lurie Cnnr Project No. 16-175 Report No. 7 cc: Gene Ross Elliott Merrill Bob Stark Structure -Con. Carl Peterson SLC Bldg Dept File OCEAN HARBOR SOUTH CONDOMINIUMS CONCRETE REPAIRS 4250 NORTH HIGHWAY AlA, FT. PIERCE, FLORIDA THRESHOLD INSPECTION REPORT SLC BUILDING PERMIT NUMBER: 1608-0114 PROJECT NAME: Ocean Harbor South Bldg A CLIENT: Elliott Merrill Community Mgt. CONTRACTOR: Structure -Con INSPECTED BY: Mike Luc WORK INSPECTED: Building A — North Building Balcony repairs DATE: December 23, 2016 LOCATION: Ft. Pierce, Florida PROJECT MGR: Khris McConnell WEATHER: Sunny Unit 1001 1. The one pt cable at the north east corner has been tensioned and the pocket where the lock off was placed can be poured. 2. Two additional pt cables along the north slab edge required repair due continued corrosion of the reinforcing bars behind the cables along the slab. 3. The reinforcing bars have been cleaned and coated with rust inhibitive primer. The cables have been locked off and spliced. The first pour at these to cables is approved in order to re -tension the two cables and will allow the lock to be removed and then the final pour once the concrete has achieved a minimum of 3500 psi 4. Once this pour is completed, the concrete water proofing and the final coating and stucco can be finished. This will complete the repairs to this balcony. 1 M L Engineering, Inc. Project No. 16-175 Repor ; ajG Consulting Engineers cc: Gene Ross Elliott Alt 203037' Avenue SCANNED Bob Stark Structure -Con. Vero Beach, Florida 32960 pv Carl Peterson SLC Bldg Dept Phone (772) 569-1257 v T File Fax (772) 569-4041 St. Lucie County mlengineeringinc.com , OCEAN HARBOR SOUTH CONDOMINIUMS CONCRETE REPAIRS 4250 NORTH HIGHWAY AlA, FT. PIERCE, FLORIDA THRESHOLD INSPECTION REPORT SLC BUILDING PERMIT NUMBER: 16 8-0114 PROJECT NAME: Ocean Harbor South Bldg A CLIENT: Elliott Merrill Community Mgt. CONTRACTOR: Structure -Con INSPECTED BY: Mike Lue WORK INSPECTED: Building A —North Building Balcony repairs Unit-208 DATE: December 5, 2016 LOCATION: Ft. Pierce, Florida PROJECT MGR: Khris McConnell WEATHER: Sunny 1: The 3 post tension cables have been spliced and replaced from inside the unit east to the balcoriy edge. The new anchors were placed all the way out to the edge so they can be stressed. *Concrete around the anchors have been poured and cables stressed. 2. The'three splice couplers have been taped. The cable ends need to be cut shorter with a torch so that the greased end caps can be placed and properly grouted. The concrete can be poured around the splice couplers at the door sill. All anchors for the re- installation of the door track shall be stainless steel anchors in holes sealed with a polyurethane sealant with a maximum embedment of 1" so as to avoid damaging pt cables Unit 1001 1. The one pt cable has been locked off and spliced. 2. Provide a 90 degree comer lap bar with 12 inch legs each way to tie the edge bars. Raise the bursting bars and corner bar for proper concrete coverage. Pour concrete and re -tension once the concrete has achieved a minimum of 3500 psi 91018 0 J30 03AGJ3a M L Engineering, Inc. Consulting Engineers 2030 37" Avenue Vero Beach, Florida 32960 Phone (772) 569-1257 Fax (772)569-4041 mlengineeringinc.com Project No. 16-175 Report No. 6 cc: Gene Ross Elliott Merrill Bob Stark Structure -Con. Carl Peterson SLC Bldg Dept File Pic 3 Unit 1001 Pt cable splice and ready for concrete pour before re -stressing cable Note the bottom bars at the corner and under the anchor needs to be raised up to provide the proper concrete coverage Provide a 90 degree #4 corner lap bar. M L Engineering, Inc. Consulting Engineers 2030 37' Avenue Vero Beach, Florida 32960 SCANNED Phone (772)569-1257 Fax (772) 5694041 p" mlengineeringinc.com O I St. LUCID (,our Project No. 16-175 Repo No. S cc: Gene Ross Elliott Merrill Bob Stark Structure -Con. Carl Peterson SLC Bldg Dept File OCEAN HARBOR SOUTH CONDOMINIUMS CONCRETE REPAIRS 4250 NORTH HIGHWAY AIA, FT. PIERCE, FLORIDA THRESHOLD INSPECTION REPORT SLC BUILDING PERMIT NUMBE i 60$ 0114 PROJECT NAME: Ocean Harbor South Bldg A CLIENT: Elliott Merrill Community Mgt. CONTRACTOR: Structure -Con INSPECTED BY: Mike Lue DATE: November 22, 2016 LOCATION: Ft. Pierce, Florida PROJECT MGR: Khris McConnell WEATHER: Sunny WORK INSPECTED: ILE Building A —North Building Balcony repairsFCOPY Unit 208 ; E The 3 post tension cables have been spliced and replaced from inside the unit east to the balcony edge. The new anchors were placed all the way out to the edge so they can be stressed. Provide 2.44 bursting bars behind the anchors at the slab edge. Bars need to be epoxy anchored in the middle of the slab. Since the slab is only about 4 to 5 inches thick the bars should be offset and should not be aligned vertically. 2. There were existing splices in the same 3 cables which had to be excavated to so that the new cables can be tensioned. 3. Tape all exposed post tension cables and connections. Unit 1001 1. Concrete repair needed at NE corner of balcony. There is one pt cable that had to be locked off and will require to be spliced and re -tensioned. 2. The repair to the cable at the north edge has been completed. Cable spliced, re -tensioned and encapsulated, ready for concrete repair mortar. Unit 1101/1001 1. The 2 cables at NE corner of the 1101 floor slab (1001ceiling) have been repaired, re - tensioned and first concrete pour completed. The second pour is now ready. All splice couplers shall be encapsulated in PVC or taped to prevent corrosion. RECEIVED NOT 2 8 1016 M L Engineering, Inc. Consulting Engineers 2030 376 Avenue Vero Beach, Florida 32960 Phone (772) 569-1257 Fax (772)569-4041 mlenginceringinc.com Project No. 16-175 Report No. 5 cc: Gene Ross Elliott Merrill Bob Stark Structure -Con. Carl Peterson SLC Bldg Dept File PA dJ( .N �\ M L Engineering, Inc: Consulting Engineers 2030 371° Avenue s` Vero Beach, Florida 32960 \\ Phone (772) 569-1257 Fax (772)569-4041 mlengineeringinc.com SCANNED BY St. Lucie County Project No. 16-175 Report No. 4 cc: Gene Ross Elliott Merrill Bob Stark Structure -Con. Carl Peterson SLC Bldg Dept File OCEAN HARBOR SOUTH CONDOMINIUMS CONCRETE REPAIRS 4250 NORTH HIGHWAY AIA, FT. PIERCE, FLORIDA THRESHOLD INSPECTION REPORT SLC BUILDING PERMIT NUMBE . I6 8- 714 PROJECT NAME: Ocean Harbor 1 CLIENT: Elliott Merrill CONTRACTOR: Structure -Cori INSPECTED BY: Mike Lue South Bldg A DATE: November 11, 2016 Community Mgt. LOCATION: Ft. Pierce, Florida PROJECT MGR: Khris McConnell WORK INSPECTED: Building A — North Building Balcony repairs Unit 808 WEATHER: 'Sunny 1. The ceiling spallslbave been excavated and all corroded reinforcing bars exposed. The corrosion has.beemi hased and all bars have been cleaned, primed and ready for pour. The total area of ceiling repair is 19 square feet. 2. The edge crack'at the southern edge needs excavation and repair. Unit 1001 1. The northern slab edge has been excavated and one pt cable has been locked off. The existing reinforcing bars have been cleaned, primed and ready for pour. The total area is 5 linear feet. 2. The northeast slab edge comer is in progress. One pt cable was discovered and will require locking off prior to further excavating. Unit 11� 1. The northeast corner has been excavated and one pt cable locked off. The existing reinforcing bars have been cleaned and primed. The end of one bar running in the north to south direction will require cutting to provide an edge clearance of 1 r/2". The total area of repair is 4 linear feet of edge and 2 square feet of full depth. All splice couplers shall be encapsulated in PVC or taped to prevent corrosion. RECEIVED NOV 18 7016 A M L Engineering, Inc. Consulting Engineers 203037' Avenue Vero Beach, Florida 32960 Phone (772) 569-1257 Fax (772)569-4041 mlengineeringinc.com Project No. 16-175 Report No. 4 cc: Gene Ross Elliott Merrill Bob Stark Structure -Con. Carl Peterson SLC Bldg Dept File M L Engineering, Inc. Project No. 16-175 Report No. 4 Consulting Engineers 2030 37' Avenue Vero Beach, Florida 32960 Phone (772) 569-1257 Fax (772)569-4041 mlengineeringinc.com cc: Gene Ross Elliott Merrill Bob Stark Structure -Con. Carl Peterson SLC Bldg Dept File M L Engineering, Inc. Consulting Engineers ,VNIVItlC® 2030 37 ° Avenue SCANNED Vero Beach, Florida 32960 BY Phone (772) 569-1257 7t 1_IIt;IP r%oUOty Fax (772) 5694041 q mlengineeringine. com Project No. 16-175 Report No. 3 cc: Gene Ross Elliott Merrill Bob Stark Structure -Con. Carl Peterson SLC Bldg Dept File OCEAN HARBOR SOUTH CONDOMINIUMS CONCRETE REPAIRS 4250 NORTH HIGHWAY AIA, FT. PIERCE, FLORIDA THRESHOLD INSPECTION REPORT SLC BUILDING PERMIT NUMBER: 1 - 114 PROJECT NAME: Ocean Harbor South Bldg A DATE: October 26, 2016 CLIENT: Elliott Merrill Community Mgt. LOCATION: Ft. Pierce, Florida CONTRACTOR: Structure -Con PROJECT MGR: Khris McConnell INSPECTED BY: Mike Lue WEATHER: Overcast slight rain WORK INSPECTED: Building A — North Building Balcony repairs Unit 1001 1. The spall at the door threshold has been repaired. 2. Concrete has been chipped out at the edge spalls on the north and east balcony edges. The reinforcing and pt anchors have been cut back, cleaned and coated with corrosion inhibitor on the east edge. Remove the excess paint from the anchor insert to allow the greased.end caps to be placed. 3. The anchor and reinforcing is slightly high in the slab but they cannot be moved deeper in to the slab unless other unaffected bars are removed. Clean the reinforcing bars and anchors and repair the cable end and concrete. 4. There is an area of approximately 9 sq feet of ceiling and edge spall at the northeast corner. This may require locking off at least one cable at the north edge. Contractor to verify if there are other cables along the adjacent east prior to chipping out the concrete. Unit 1006 5. Check for additional surface spall at balcony edge. [E0F.0 7 OCT 3 1 RM t. y I M L Engineering, Inc. Consulting Engineers 2030 37 ° Avenue Vero Beach, Florida 32960 Phone (772) 569-1257 Fax (772) 5694041 mlengineeringinc.wm Project No. 16-175 Report No. 3 cc: Gene Ross Elliott Merrill Bob Stark structure -Con. Carl Peterson SLC Bldg Dept File Pic I Unit 1001 East edge repair Pic 2 Unit 1001 North edge repair Anchor and bursting bar is close to surface Pic 3 Unit 1001 Ceiling spall at north east corner May have to lock off this cable Check for cables along this edge Prior to lock off and demolition ^ M L Engineering, Inc. - Consulting Engineers 2030 37' Avenue Vero Beach, Florida 32960 Phone (772) 569-I257 Fax (772)569-4041 mlengineeringinc.com S AiVNED St. LucBY County Pra No. 16-175 Report No. 1 cc: Gene Ross Elliott Merrill Bob Stark Structure -Con. Carl Peterson SLC Bldg Dept File OCEAN HARBOR SOUTH CONDOMINIUMS CONCRETE REPAIRS 4250 NORTH HIGHWAY AIA, FT. PIERCE, FLORIDA THRESHOLD INSPECTION REPORT SLC BUILDING PERMIT NUMBER: M0011147 PROJECT NAME: Ocean Harbor South Bldg A DATE: October 3, 2016 CLIENT: Elliott Merrill Community Mgt. LOCATION: Ft. Pierce, Florida CONTRACTOR: Structure -Con PROJECT MGR: Khris McConnell INSPECTED BY: Mike Luc WEATHER: Overcast slight rain WORK INSPECTED: (l3uildin W — orth Building Balcony repairs Unit Demolition of the concrete was observed at several locations which included the following: 1. Surface repair along the exterior at the south sliding glass door. This appeared to be loose decorative topping on a previously repaired area and no structural damage to the slab. 2: Slab edge 6f the."outh facing balcony. There was some corrosion of the reinforcing and no post tension ;cables are affected, repair as per the documents 3:' Full depth repair -in the middle of the slab on the south side. This was caused by a corroded post tension splice coupler that was not encapsulated or taped. The coupler should be mechanically cleaned, coated with a corrosion inhibitor and wrapped with a PVC tape. Do not excavate any further behind the bearing end of the anchor. 4. Column repairat the north end. There is corrosion of the reinforcing at the bottom of the column which extends down into the columns. Further excavation into the slab is required to repair the column as per the documents. Re -inspect prior to concrete placement. OCT 1 3 REC'D P + M L Engineering, Inc. Consulting Engineers 2030 37 ° Avenue Vero Beach, Florida 32960 Phone(772) 569-1257 Fax (772)569-4041 mlengineeringine.com Prtt• - t No. 16-175 Report No. 1 cc: Gene Ross Elliott Merrill Bob Stark Structure -Con. Carl Peterson SLC Bldg Dept File Pic 2 Loose decorative topping in front of the exterior sliding glass door. At previously repaired area 2