HomeMy WebLinkAboutREVISIONOFFICE USE ONL )
DATE FILED: /
REVISION FEE: �� _ 0 (D
St, Lucie County
n� Lq` Lly S `� q F; 3I'IY7
PERMIT # v,-HW ali [''l / ; ,N^✓,a2
RECEIPT# Iev7 ► 7-) �k �iJ 1�`YV�►V\f
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982-5652
(772) 462-1553 FAX (772) 462-1578
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
1. LOCATION/STTE
ADDRESS: 4400 N AIA, Fort Pierce
2. DETAILED DESCRIPTION OF PROJECT
REVISIONS:
NT
3.
CONTRACTOR INFORMATION:
STATE of FL REGJCERT. #:
BUSINESS NAME:
QUALIFIERS NAME:
ADDRESS: 305 Avenue
CITY: Fort Pierce
PHONE (DAYTIME): !%247
4. OVVNER/BUH.DER INFORMATION:
NAME:
ADDRESS:
CITY:
PHONE:
INFORMATION:
NAME: _
ADDRESS: _
CITY: _
PHONE (DAYTE%IE):
Revised 07/22/2014
TMES6 PLANS AND ALL PROPOSED W04€{
ARE SUBJECT TO ANY CORRECTIONS
`REQUIRED BY FIELD INSPECTORS THAT
NIAY BE NECESSARY IN ORDER TO
CCPAPCf WITH ALL APPLICABLE CODES.
ST. LUCIE COUNTY CERT. #: 25568
Construction LLC;
.1lAl E:
FAX:
STATE:
STATE:
ZIP:
FAX:
ZIP:
FAX:
'Q
ST. LY IE COUN
BUILDING DIVISION
REVIEW
FOR CO
REVIEWED Y
DATE - p
PLANS AfJD PEAMIT
MUST BE KEPT ON JOB OR
NO INSPECTION WILL BE MADE
rixyc L V1 �
BCIS Home Log In j User Registration Hot Topics : Submit Sumhame stats & Facts Publimtlons I MC Staff BCIS site Map i Links Search
bip,
v Product Approvalr rUSER: Publlr ser
<�=C'
Prod um Aoomval Me� 11 > a I Sea rMh > ADoli a�'stt > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
S`
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Emall
Category .
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida license
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
FLvision 25
Revision
2014
Approved
0
POLYGLASS USA
150 Lyon Drive
Fernley, NV 89408
(570) 384-1230 Ext 242
jakins@polyglass.com
James Akins
jakins@polyglass.con
Steve Wadding
150 Lyon Drive
Fernley, NV 98408
(602) 363-7139
stevew@polyglass.com
James Akins -
555 Oakridge Road
Humboldt Industrial Pkwy
Hazleton, PA 18201
(800) 894-4563
jakins@polygla ss. tom
Roofing
Underlayments
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
!_j Evaluation Report - Hardcopy Received
Robert Nieminen
PE-59166
UL LLC
04/24/2018
John W. Knezevkh, PE
Validation Checklist - Hardcopy Received
FL5259 R25 COI 2016 01 COI Nieminen odf
Standard
Year
ASTM D1970
2009
ASTM D226
2006
ASTM D6164
2005
ASTM D6222
2008
ASTM G154
2006
ASTM G155
2005
FM 4474
2004
https://www. floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3Crk... 3/1/2017
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summ2ry of Products
FRSA/TRI April 2012
TAS 103
UL 1897
2012
1995
2004
Method 1 Option D F Nti. - � Cop,"
}
10/17/2016
10/18/2016
10/19/2016
1211512016
FL #
Model, Number or
Description
Name
5259.1
Polyglass Roof
Roofing underlayments
Underayments
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FL5259 R25 Il 2016 10 FINAL ER POLYGLASS UND RI AYMENTS FLS 59
R25.odF
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure in this
Evaluation Reports
application relates to one Particular
FL5259 R25 AE 2016 10 FINIAL ER POLYGLASS UNDERLAYMENTS F 25g
underlayment system (over concrete
2R 5_odf
deck) for use under foam -on the systems
Created by Independent Third Party: Yes
(where the underlayment forms part of
the load -path). Refer to ER Section 5.6.4
for other systems, other deck types and
associated maximum design pressures.
2.) Refer to ER Section 5 For otter limits
of use.
Back Next
contact Us :: 201 ala r Ston, Road. TIlah,llSg FL 32399 Phnnn, 050-491-1814
The State of Force Is an AVEED employer. Cow,rcht 2007- 013 State of Florida. :: Pnvacv Staemwn:: 4 rn,e.ihIIIN State
ment:: 0.nfiuntl statement
Under Florida law, email addresses are public records. Ifyou do not want your e-mall atltlress released in response to a public -records request, do not send
electronic mall to this entity. Instead, mould Me office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to section 455.275(1), Florida Statutes,-Uedlve October 1, 2012, licensees loomed under chapter 455, F.S. most provide the Department with an email address if
May have one. The emaik pravided may be used for official communlmUon with the licensee. However email addresses are public real If you d0 not wish to
Supply a personal address, please provide We Department with an email address which can be made available to the public. To determine if you are a licensee under
Chapter 455, F.S., please tlich Jt{gi
Product Approval Accepts:
WRI Ed®-
.SCCi11'lT}'Af 171tIC3'
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3 Crk... 3/1 /2017
�� TRINITY! ERD
EVALUATION REPORT
EXTERIOR RESEARCH & DESIGN, I.I.C.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
Polyglass USA, Inc. W py Evaluation Report P12060.02.09-R21
150 Lyon Drive LE FL5259-R25
Fernley,FerNV 98408 Date of Issuance: 02/24/2009
SCOPE: Revision 21:10/17/2016
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 5u' Edition (2014) Florida Building Code sections noted
herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the jab site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 13.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59165, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert Nieminen,
P.E. an 10/17/2016. This does not serve as an electronically
signed document. Signed, sealed hardcoples have been
transmitted to the Product Approval Administrator and to the
named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity) ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
{
' TRIRllTY'; ERD
ROOFING COMPONENT EVALUATION: � LE
COPY
1. SCOPE: F
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is
subject to the Installation Requirements and Limitations / Conditions of Use setforth herein.
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind Uplift
FM 4474
2004
1504.3.1
Wind Uplift
UL 1897
2004
1504.6
Accelerated Weathering
ASTM G154
2006
1504.6
Accelerated Weathering
ASTM G155
2005
1507.2.3, 1507.3.3, 1507.5.3, 1507.7.3,
Physical. Properties
ASTM D226
2006
1507.8.3, 1507.9.3
1507.2.4, 1507.2.9.2, 1507.5.3,1507.7.3
Physical Properties
ASTM-D1970
2009
1507.11.2
Physical Properties
ASTM D6164
2005
1507.11.2
Physical Properties
ASTM D6222
2008
1507.3.3
Installation Practice
FRSA/TRI April 2012
2012
1523.6.5.2.1
Physical Properties
TAS 103
1995
3. REFERENCES:
Entity
Examination
Reference
Date
FM Approvals (TST 1867)
Wind Uplift
3004091
01/12/2000
PRI (TST 5878)
Physical Properties
PRIO1111
04/08/2002
PRI (TST 5978)
Physical Properties
PUSA-005-02-01
01/31/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-01
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-02
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-03
12/23/2002
PRI (TST 5878)
.Physical Properties
PUSA-018-02-01
07/14/2003
PRI (TST 5878)
Physical Properties
PUSA-028-02-01
07/13/2005
PRI (TST 5878)
Physical Properties
PUSA-033-02-01
01/12/2006
PRI (TST 5878)
Physical Properties
PUSA-035-02-01
09/29/2006
PRI (TST 5878)
Physical Properties
PUSA-055-02-02
12/10/2007
PRI (TST 5878)
Physical Properties
PUSA-061-02-02
01/28/2008
PRI (TST 5878)
Physical Properties
PUSA-076-02-01
02/22/2008
PRI (TST 5878)
Physical Properties
PUSA-083-02-01
04/14/2008
PRI (TSTS878)
Physical Properties
PUSA-088-02-01
07/29/2009
MTI (TST 2508)
Physical Properties
JX20H7A
04/01/2008
MTI (TST2508)
Physical Properties
RXIMA
01/29/2009
ERD (TST 6049) _
Physical Properties
11752.09.99-1
02/08/2000
ERD (TST 6049)
Wind Uplift
11757.08.01-1
08/13/2001
ERD (TST 6049)
Wind Uplift
11776.06.02
01/16/2003
ERD (TST 6049)
Physical Properties
02200.07.03
07/14/2003
ERD (TST 6049)
Wind Uplift
P1740.01.07
01/04/2007
ERD (TST 6049)
Physical Properties
P5110.04.07-1
04/11/2007
ERD (TST 6049)
Wind Uplift
P9260.03.08
03/21/2008
ERD (TST 6049)
Physical Properties
P13450.08.09
08/13/2009
ERD (TST 6049)
Wind Uplift
P30540.11.09-R3
11/30/2009
ERD (TST 6049)
Physical Properties
P11030.11.09-1
11/30/2009
ERD (TST 6049)
Wind Uplift
P11030.11.09-2
11/30/2009
ERD (TST 6049)
Physical Properties
P11030.11.09-3
11/30/2009
ERD (TST 6049)
Physical Properties
P33360.06.10
06/25/2010
Exterior Research and Design, LLC.
Certificate of Authorization #9503
FBC NON-HVHZ EVALUATION
Evaluation Report P12060.02.09-R21
FL5259-R25
Revision 21: 10/17/2016
Page 2 of 13
Entity
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERO,(TST6D49)
ERD (TST 5049)
ERD (TST 6049)
ERD OST 6D49)
ERD (TST 6049)
ERE) MT 6049)
ERE) (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD.(TW 6049)
ERO (TST 6049)
ERD tTST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD.(M 6049)
ERD (TST 60491
ERD (TST 60491
ERD (TST 6049)
ERD (TST. 6049)
ERD (TST 60491
ERD (TST 6049)
ERD (TST 6049) _
]CC -ES (EVL2396)
Miami -Dade (CER 1592)
Polyglass USA
Poiyglass USA
Po€yglassUSA
UL, U.C. (QUA9625)
4. PRODUCT DESCRIPTION:
4.1
4.1.1
4.1.2
4:1.3
4,1.4
4.2
Examination
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Wind Uplift
Physical Properties
Wind Uplift
Wind Uplift
Wind Uplift
Wind Uplift
Wind Uplift
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical-Pmperties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Wind Uplift
Physical Properties
Wind. Uplift
IRC.Compliance
HVHZ Compliance
Manufacturing Affidavit
P/LAffidavit
Materials Affidavit
Quality Control
Reference
P33370.03.11
1`33370.04.11
P37300,10.11
P40390.08.12-1
P40390.08.12.2
C41420.09.123
P39680,03:13
P45370.04.13
P1738.02.07-R2
11757.04.01-1-R1.
P41630:08.13
P11751.05.03-R1
P13781.11.03-R1
P45270.05.14
6020.07.14-1
6020.09.14-2
6020.09.143
6020,09.14-4
6020,09.14-5
602009.14.6
P46526.10.14
P44360.10:14
P43290.10.14
PLYG-50550.031S
P40390.04.1S
PLYG-SC8080A5:15-1
PLYG-SC8905.05.16.1
PLYG-SC8080.07.16
PLYG-SC12025.I0.16
E5114697
NOA 14-0717.08
Products Current
Mute-Hide'Cross Lig
POlyst(ck3A Compound
Seivi-ce2onfirmation
Mechanically Fastened Underlavments:
Elastobase Is a fiberglass reinforced, SBS modified bitumen'basesheet..
Elastobase Pis a polyester-reinforced,.SBS modified bitumen base sheet.
Polygiass G2 Base is a fiberglass-refrlforced, asphaltic tigA sheet-
Polygiass API Base is a
4.2.2 Polystick MTS
surfaced with
M
iai 60-mil thick
meets TAS 103.
g TRINITY ERD
Date
03/02/2011
04/26/2011
10/19/2011
08/06/2012
08/07/2012
09/11/2012
03104/2013
04/26/2013
04/29/2013
04/3012013
08/06/2013
11/2612013
11/26/2013
O5/12/2014
09/08/2014
09/08/2014
09/98/2014
09/08/2014
09/08/2014
09/08/2014
1D/03/2014
SD/07/2014
16/17/201-4
03/24/2015
04/03/2015
05/2012015
05/17/2016
07/16nGlii
10/1212016
11/01/2014
01/2212015
02118/2009
03/01/2008
08/18/2011
Exp-04/24/2018
asphalt waterproofing membrane, glass fiber reinforced, surfaced
membrane; glass fiber reinforced,
41.3 PolystickIR-Xe Wa nominal 60-mil. thick -rubberized asphalt waterproofing membrane, glass fiber reinforced,. with an
aggregate surface; meets ASTh9 D1970. -
Exterior Research and Design, I.I.C. Evaluation. Report P12060:02.09-R21
Certiirate o/Autlrorizotion 495M FBC NON-HVHZEVALUATION PL5259-R75
Revision 21:.10117/2016
Page 3 of13
TRI iTf iERD
43;4 Polystick TU Plus is a.nominal 80-mil thick rubberizedasphalt waterproofing membrane, glass fiber reinforced, with a
polyester fabric surface; meets ASTM 01970 and TAS 103.
4.2.5 Polystick TU P is a nominal 130,mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester
reinforced, with a granular surface; meets ASTM D1970 and TAS 103.
4.2.6 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing. membrane with a 190 g/m2 polyester
fabric surface; meets ASTM D1970 and TAS 103.
4.2.7 Polyfiex. SAP, Polyflex: SAPTR, Mute -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet.(FR) are polyester
reinforced, APP modified bitumen cap sheets; meet ASTM D6222.
4,2.8 Polystick-Dual-Pro s a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
enforced, w$h a polyester fabric surface; meetsASTM D1970.
4.2.9 Polystick Tile ProTM is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with.a.polyester rfabric surface; meetsASTM D1970. and TAS 103.
4.2.10 Polystick MU-X is a nominal 54-mit thick dual -layer rubberized -asphalt waterproofing membrane, fiberglass
reinforced, with a polypropylene film surface; meets.AC188and physical requirements: of ASTM 1)1970.
4.3 Mechanically Fastened and/or Banded'Underlayments•
4.3.1 Elastoftex $6 G and Eiastoflex S6 G FR are, polyester reinforced, 5BS modified bitumen cap sheets; meet,ASTM D6164.
4.3.2 Polyflex G and:Polyflez G FIR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM-D6222.
LlmrraioNS: \
SA This is a buiti ing•code evaluation. -Neither TrinhyffRD nor Robert Nleminen, P.E: are, In any way; the Designer of
Record for anyprojecton which this Evaluation Report, or previous versions thereof, is/was used for permittingor
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report isnot for use in the HVHZ
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Polygiass Roof Underlayments'may be used with any, prepared roof cover where theproductIs specifically referenced
within FBC -approval documents. "if not listed, a request may be made; to the Authority Having iurlsdiction for
approval based as this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers:
dk
7?A9teS:itoaP
Undedayrnent _ Asphalt S4ing!ps
Nail -On Tile
roam -On Tik
.Metal
Wood Shakes&shingles
slate
Yes
Yes
Elastobase Yes
(te+se sheet;
1t.yheet in z�m:
yes
Yes
Yes
-
system)
W."e).
Yes
Yes_
-
E!astn6ase F Yes
;e,;etrces;o 2,ryy.
jb>.nc:imz-y
Yes
Yes
Yes
__
i
arasm}
syitart)
Yes
Y2r
Polyglass G28ase. No
16sse.:heetm bpR
{eaaexnmin2:py
No
No
No
A_. 1
wemi
:n�ml
Yes'
- Yes
---
PolyglassAPPBase � No
lnaseanee:�zy!r
@sue: ebn zya
No
No
No
syvam)
ssstaml
PtilystickMTS Yes
Yes
No
'Yes
Yes
Yes - 1
__
. Pow lysti6i MTS.PLUS _------� Yc4
Yes
No
Yes
- Yes
yes
PoiystitkiR-Xe _ Yes
No
No
No
Yes
Yes
` PohstickTUP i Yes
Yes
Yes
No
Yes
Yes
See x:S;t
PoiystickTUPius Yes
Yas
Yes
Yes
Yes
Yes
5L
Exterior Research and Design; I.I.C.
tett)fcote ofAuthadrotion k9503 'FBC NON-HVHZ EVALUATION
Evaluation • Report P12060.02.09-R21
FLS259+R25
.Revision 21: J-0/17/2016
Page 4of13
t ': 'a lr�e ,Zrktaa 14, Y.iL
`TF IN"IERD
✓` i 7 -„ _ 'ra
<- TABI.!',.�,t ROgT Caveit0 71a
' •' �`
W000d
Underlayment� I AsphaltShrngles
Nail-OnTile
Foam-on'rie
Metal
Bows&�
Slate
i__........._..___.�.._._..._._
l Max No
Yes
i Yes
Yes
No
No
�Poiy$yckTU
See 5..5.1
j Polyttk alai Pro Yes
Yes
I No
Yes
Yes
Yes
Polystick Tit Pro Yes
Yes
Yes
Yes
Yes
Yes'
Sec5S1
PalysrirkMU-A Yes
W.-
a N
No
Yes
Yes
I Elastoflex S5G Yes
LL _
Yes
_
Yes
_Yes
No
Yes
_
Yes
—...._.._._ ._._..._____.._.,
See ss3
Elasmflcx SGGFR Yes
Yes
No
No
Yes
Yes_
PowexG Yes
Yes
Yes
No,
Yes
Yes
__
See 53.1
FR Yes
Yes
No
No
Yes
Yes
_PolyRexG
Potyllex SAP of SAP FR Yes
Yes
Yet
No
Yes
Yes
&e 55.1
Mule -Hide SA-APPc.P eet Yes
Yes
Yes
No
Yes
Yes
( orSA-APP Cap Sheet (FR) _ _ _ _
See s5:1
5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives unless tensile adhesion / long term aging
data from an accredited testinglaboratory, is provided.
✓ 3110'" 2-Component Roof Tile Adhesive AH-160 (FL6332): Polystick TU P, Polystick TU Plus, Polystick TU Max,
Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule-Hlde:SA-APP Cap Sheet or Mule -Hide SA-APP
Cap Sheet (FR) or Tile Pro.
✓ 31VI'" Foam Roof Tile. Adhesive RTA-1 (EL6276): Polystick TU P,.Polystick ?U Plus,Polystick TU -Max, Elastoflex S6
G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
or Tile Pro
✓ Convenience Products' Touch `n Seal Storm Bond Roof Tile Adhesive (FL14506): Polystick TU Plus, Polystick TU
Max.
✓ Dow TileBOnd (FL717) Polystick TU P;.PolystickTU Plus, Polyflex SAP or Tile Pro.
✓ Polyglass Polylok Roof Tile Adhesive (FL17855): Polystick TV Plus or Polystick TU Max.
5.6 Allowable Substrates:
S.6.1
Polystick (all. variations)filj- ile"Pro, Polyflex SAP or SAP FR, Mule-Hide-SA-APP Cap Sheet or SA-APP Cap Sheet.
(FR):.selfadhered to:
= New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing
plywood; New or existing, -unprimed 056;. ASTM 'D41 primed -058; Southern Yellow 'Pine; _ASTM D41 primed
Southern yellow Pine;- ASTM D41-primed structural concrete; Huber Engineered Woods 'ZIP System" Panels
(designed and installed to meet wind loads for project). -
Note: Polyglass does not require priming of new or existing plywood or OSB sheathing: New or existing plywood or
OSS sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes.
Elastoflex S6 G or S6 G FR in hot asphalt to:
ASTM D41 primed structural concrete.
Polyflex G or G FR torch -applied to:
ASTM D41 primed structural concrete.
11 "J"k
S 4
Exterior Research and Design,LLC. Evaluation Report: P12060,02.09•1121
Certificate of Authanzation #9503 FBC NON-HVHZ-EVALUATION FL5259-R25
Revision 21: 10/17/2016
Page 5 of 13
TRINITY ERD
5.6.2 Bond -to -Insulation:
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered
to:
➢ ASTM C1289, Type 11, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck
DuraGuard; Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board.
Elastoflex S6 G or S6 G FR in hot asphalt to:
➢ Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
Polyflex G or G FR torch -applied to:
➢ ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile
systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of
the insulation/underlayment system in accordance with FBC Section 1504.3.1.
5.6.3 Bond to Mechanically Attached Base Laver:
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or
Tile Pro self -adhered to:
➢ ASTM D226, Type I or 11 felt; Elastobase; Elastobase P or Mule -Hide Nail Base.
Elastoflex S6 G or S6 G FR in hot asphalt to:
➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P, Mule -Hide Nail Base or Polyglass G2 Base.
Polyflex G or G FR torch -applied to:
➢ Elastobase; Elastobase P, Mule -Hide Nail Base, Polyglass G2 Base or Polyglass APP Base.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minirrlum
codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested In
accordance with FBC Section 1504.3.1.
5.6.4 Wind Resistance for Underlavment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment
forms part of the load -path. The -following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications, Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure
divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-
12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads.
5.6.4.1 Maximum Design Pressure =-90 osf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None
Base Ply: (Optional) Polystick NITS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
5.6.4.2 Maximum Design Pressure =-97.5 osf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG 100 or ASTM D41
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
1Y." ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
Exterior Research and Design, LLC.
Certificate of Authorization #9503
FBC NON-HVHZ EVALUATION
Evaluation Report P12060.02.09-1121
FL5259-RZS
Revision 21: 10/17/2016
Page 6 of 13
\-IJTR1NIIY ERD
5.6.4.3 Maximum Design Pressure=-105 osf•
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-3000
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
134" ring shank nails through 32 ga., 1-5/9" diameter tin caps spaced 12-inch o.c.
5.6.4.4 Maximum Design Pressure=-135 osf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) PG100 or ASTM D41
Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints.
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
5.6.4.5 Maximum Design Pressure=-33.5 osf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Tile Pro, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap
Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
5.6.4.E Maximum Design Pressure = -622 5 osf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. -
5.6.4.7 Maximum Design Pressure = -30 0 osf*:
Deck: Min. 15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-Inch o.c. at the 3-Inch wide side laps and 6-Inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
5.6.4.8 Maximum Design Pressure =-37 5 osf•:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
5.6.4.9 Maximum Design Pressure=-37.5 osf*
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) or two (2) layers ASTM D226, Type II felt
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-Inch wide side laps and 12-inch o.c, at two (2) equal ly spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
FILEin
Exterior Research and Design, LLC.
Certificate ofAuthorizodon #9503
i
FBC NON-HVHZ EVALUATION
Evaluation Report P12060.02.09-1121
FL5259_R25
Revision 21: 10/17/2016
Page 7 of 13
TRINITY ! ERD
5.6.4.10 Maximum Design Pressure =.45 osf':
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) layer ASTM D226, Type II felt
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c. at the 2-inch wide side laps and 4-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex S6 G, applied in full mopping of hot asphalt.
5.6.4.11 Maximum Design Pressure =.45 osf':
Deck: Min.19/32-Inch plywood to meet: project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Two (2) layers ASTM D226, Type II felt
Fasteners: 11 ga.x 1.25-inch long 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 9-Inch o.c. at the 2-inch wide side laps and 9-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex 56 G, applied in full mopping of hot asphalt.
5.6.4.12 Maximum Design Pressure =-45 osf:
Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c. at the 2-inch wide side laps and 18-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
5.6.4.13 Maximum Design Pressure =-52.5 osf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastabase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
5.6.4.14 Maximum Design Pressure =-52.5 osf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-Inch o.c. at the 3-Inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
5.6.4.15 Maximum Design Pressure=-52.5 osf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: 6-Inch o.c. at the 3-Inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied.
5.6.4.16 Maximum Design Pressure =-60 osf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c, at the 4-inch wide side laps and 8-inch o.c. at three(3) equally spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
x71 s;M
+ c r 3f 3r "Y `{
;fit&; g.:.e. s`_"111 � a,
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-R21
Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION FL5259-R25
Revision 21: 10/17/2016
Page 8 of 13
l` TRINITY ERD
5.6.4.17 Maximum Design Pressure =-60 osf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: 12-Inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied.
5.6.4.18 Maximum Design Pressure = -67 5 osf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underloyment)
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or torches pplied or Polyflex G, torch -applied.
5.6.4.19 Maximum Design Pressure =-75 osf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torchapplied undedoyment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 1G-Inch o.c. at the 4-inch wide side laps and 10-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
5.6.4.20 Maximum Design Pressure=-90 osf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
5.6.4.21 Maximum Design Pressure =-90osf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c, at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
5.6.4.22 Maximum Design Pressure=-90 osf:
Deck: Mir'. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
5.6.4-23 Maximum Design Pressure = -90 osf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underloyment)
Fasteners: Dekfast 414 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c, at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied In full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-R21
Certificate OfAuthorization #9503 FBC NON-HVHZ EVALUATION FL5259-R25
Revision 21: 10/17/2016
Page 9 of 13
TRINIW ERD
5.6.4.24 Maximum Design Pressure =-97 5 osf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c. at the 4-inch wide side laps and 4-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
5.6.4.25 Maximum Design Pressure = -105 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 2-inch wide side laps and 5-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied.
5.6.4.26 Maximum Design Pressure =-112 5 psf;
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga.x1.25-inchx3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diametertincaps
Spacing: 6-inch o.c, at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer at all tin -caps
Base Ply: Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
5.6.4.27 Maximum Design Pressure = -120 osf:
Deck: .Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal
5.6.4.28
Plates
Spacing: 6-inch o.c. at the 4-.inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
Maximum Design Pressure = -120 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast#12 DP orTrufast#14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-Inch o.c, at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex SG G, applied in full mopping of hot asphalt.
5.6.4.29 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on tile systems carry a Maximum
Design Pressure of-45 psf.
5.6.4.30 For mechanically attached base sheet, the maximum design pressure for the selected assembly shall meet or exceed
the Zone 1 design pressure determined in accordance with FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC
1609. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the
elevated pressure criteria. Commonly used methods are RAS 117, FM LPDS 1-29 and ANSI/SPRI WD1. Assemblies
marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29
(January 2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days
after installation.
Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after installation.
Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Dual Pro or Tile Pro shall not be left exposed for longer than 180-
days after installation.
Exterior Research and Design, I.I.C.
Certificate of Authorization #9503
FBC NON-HVHZ EVALUATION
Evaluation Report P32060.02.09-R21
FL5259-R25
Revision 21: 10/17/2016
Page 10 of 13
FYTIRINITY ERD
Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30
days.
Elastoflex 56 G or 56 G FR or Polyflex G or G FR does not have an exposure limitation, unless the prepared roof
covering is to be adhesive -set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum exposure is 180
days.
6. INSTALLATION:
6.1
6.2
6.3
6.3.1
6.3.2
6.3.3
6.4
6.4.1
6.4.2
Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate (if applicable).
Elastobase. Elastobase P or Mule -Hide Nail Base:
Shall be installed in compliance with the codified requirements for ASTM D226, Type 11 underlayment in FBC Section's
1507 for the type of prepared roof covering to be installed.
Non -Tile Applications,
Reference is made to the current edition of -the NRCA Steep -slope Roofing Manual and ARMA recommendations for
installing shingle underlayments and flashings
Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP or SAP FR,
Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or Tile Pro, self -adhered, Elastoflex S6 G or S6 G FR in
hot asphalt or Polyflex G or G FR, torch applied.
Tile Applications:
Reference is made to FRSA/TRI April2O12 (04-12) Installation Manual and Table 1 herein, using the instructions noted
above as a guideline.
Polystick MTS, MTS PLUS, IR-Xe TU P TU Plus TU Max Dual Pro Tile Pro or MU X or Polvflex SAP Polyflex SAP FR
Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR):
Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Sections 1507
for the type of prepared roof covering to be installed.
Direct -to -Deck with Mechanically Fastened Roof Covers:
All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP Cap
Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam in accordance with Polyglass / Mule -Hide
Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch diameter
metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back -nailed using
the above noted fasteners and spacing, in area marked "nail area, area Para clavar" on the face of membrane. The
head lap membrane is to cover the area being back -nailed
All seal -lap seams (selvage laps) must be
firmly rolled with a minimum 28 lb. handW-1 roller to ensure full contact and adhesion. 4'
For Dual Pro and Tile Pro, align the edge of
the top sheet to the end of the glue pattern
(the sheet will overlap the fabric).
Exterior Research and Design, LLC.
Certiflrote ofAuthorizotion #9so3
View of OvelaP Seam of Dual Pro and Tile Pro
FBC NON-HVH2 EVALUATION
Evaluation Report P12060.02.09-R21
FL5259-R25
Revision 21: 10/17/2016
Page 11 of 13
6.4.3
E
TRINITY ERD
All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified
Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap.
Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys,
or exposed roof to wall details
Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or
Polyglass PG500 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the
Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be
installed in a water shedding manner.
All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a
minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied
for the field membrane. Hand rollers are'acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the
roof that are not accessible to a -large roller or broom.
Tile Applications (not allowed for PolysticklR-Xe or Polystick MU-X)• .
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted
above as a guideline.
For mechanically fastened tile roofing over 2-ply system, consisting of base sheet and self -adhering top sheet(s), base
sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1.
For adhesive -set the applications, refer to Section 5.6.4 herein.
For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile.
For nail -on tile systems over Polystick MTS PLUS:
➢ Battens are required for loading/staging of lugged tile regardless of slope.
➢ Battens are required for loading/staging of flat tile at slopes in excess of 5:12.
6.4.4 Two (2) Ply Underlayment Systems,
Polystick MTS or MTS PLUS followed by Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, rile Pro, MU-X or Polyflex
SAP is allowable for use under Mechanically attached prepared roof systems. Limits of use are those associated with
the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired.
Polystick MTS PLUS followed by Polystick TU P, TU Plus, TU Max, Tile Pro or Polyflex SAP is allowable for use under
foam -on tile systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is
allowable if a 2-ply underlayment system is desired.
6_5 Elastoflex S6 G or S6 G FR:
6.5.1 Elastoflex 56 G or S6 G FR shall be installed in compliance with current Polyglass published installation requirements.
For use in tile applications, reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein.
6.5.2 Elastoflex 56 G or S6 G FR shall be fully asphalt -applied to the substrates noted in Section 5.6. Side laps shall be
minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end
laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch
beyond the lap edge.
6_6 Polyflex G or G FR:
6.6.1 Polyflex G or G FR shall be installed in compliance with current Polyglass published installation requirements. For use
in tile applications, reference is made FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein.
6.6.2 Polyflex G or G FR shall be fully torch -applied to the substrates noted in Section 5.6. Side laps shall be minimum 3-
inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end laps shall be
fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge.
6_7 Tile Staging:
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to
Polyglass published requirements for tile staging.
Exterior Research and Design, U.C.
Certificate of Authorization #9503
FBC NON-HVH2 EVALUATION
Evaluation Report P12060.02.09-R21
FL5259-R25
Revision 21: 10/17/2016
Page 12 of 13
1
7.
8.
9.
"J TRINITY 11 ERD
6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used
on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or sail-
boards, to prevent tile sliding and/or damage to the underlayment during the loading process.
6.7.3 For nail -on tile systems over Polystick NITS, battens are required for loading / staging of the tile.
6.7.4 For nail -on tile systems over Polystick MTS PLUS:
➢ Battens are required for loading/staging of lugged tile regardless of slope.
➢ Battens are required for loading/staging of flat tile at slopes in excess of 5:12.
6.7.5 The minimum cure time after installation of self -adhering membranes and before loading of roofing tiles is forty-eight
(48) hours.
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
MANUFACTURING PLANTS:
Contact the noted CA agency for Information on product locations covered for F.A.C. Rule 61G20-3 QA requirements.
QUALITY ASSURANCE ENTITY:
UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com
Exterior Research and Design, U.C.
Certlf/cate Of AUthorization #9503
END OF EVALUATION REPORT-
:txo-
FBC NON-HVHZ EVALUATION
Evaluation Report P32060.02.09-R21
FL5259-RZS
Revision 21: 10/17/2016
Page 13 of 13