Loading...
HomeMy WebLinkAboutTEST AND BALANCE REPORTs CERTIFIED TEST AND BALANCE REPORT PERFECT BALANCE, INC., P. O. Box 1584 (561) 575-4919 Jupiter, Florida 33468-1584 SCANNED (561) 746-0726 (fax) BY St. Lucie Countv PROJECT: Uncle Bob's Self Storage 8531 South US Hwy,1 Port St. Lucie, Florida ® ARCHITECT: Stinard Architecture, Inc. i E 322 East Main Street i Cartersville, Georgia 30120 �' `° ENGINEER: Stinard Architecture, Inc. N � O U 322 East Main Street Q *U Cartersville, Georgia 30120 LU E HVAC: D& H/ Magic Air 4180 Dow Road Melbourne, Florida 32934 . This is to certify that Perfect Balance, Inc. has balanced the systems described herein to their optimum performance capabilities. The test and balancing has been performed in accordance with the standard requirements and procedures of the Associated Air Balance Council and the results of these tests are herein recorded. Associated Air Balance Council Certification Number 91-09-22 illiam C. Halm Test and Balance Engineer July 23, 2018 Project: Uncle Bob's Self Storage Location: 8531 S. US Hwy 1, Port St. Lucie, Florida Split System Unit Test Report System: FC-1/HP-1 Make Carrier Make/Frame Marathon I NA Model Number FV4CNB006 H.P./RPM %11075 Serial Number 0318FO8094 Volts/Phase/Hertz 208-230 /1 / 60 Make Sheave Direct Drive Full Load Amps/S.F. 6.8 / NA Sheave Diam/Bore NAP Make Sheave Direct Drive No. Belts/Size NAP Sheave Diam/Bore NAP No. Filters/Size (1) 21)(23X1 Sheave CL Distance NAP Type Heating Section Reverse Cycle EyaporatoiUataDesign_ Actualpawq Supply Air CFM 2000 1993 Condensor Manufacturer Carrier Outside Air CFM 525 517 Condensor Model No. 25HCE460A Return Air CFM 1475 1476 Condensor Serial No. 0518E23354 Compressor Model No. ZP51KCETF5 -NAP Compressor Serial No. 18A5115FL NAP Outside Air DB/WB NA 90.1/80.0 Return Air DBMB NA 73.2/63.1 Entering Air DBIWB NA 77.6/67.5 Condensor Fan HP Leaving Air DBMB NA 57.3/56.6 No. of Fans/Fan RPM 1/1100 Cond Fan Volt/Phase/Hz 208-23011 /60 Fan RPM NA 1075 Condensor Fan Amps 1.52 Motor Voltage T1 T2 T3 208 200 Compr. Volts TI T2 T3 200-20I-200 NAP Motor Amperage TI T2 T3 6.8 6A Compr. Amps T1 12 n 15.3 15.5 15.4 NAP Remarks: rAMCN 12= 'Raw AIMAIIASPIC MULIAM Q HALM NL TBE A 91-0 - 094'� Test Date: 07-23-20IS Readings By: Chillerm Page 1 of 12 Project: Uncle Bob's Self Storage Location. 8531 S. US Hwy 1, Port St. Lucie, Florida Air Outlet Test Report System: FC-1 Test Apparatus: Flowhood AN Units 104 1 S-1 10X6 175 55 174 Units 104 2 S-1 I0X6 200 69 187 Units 104 3 S-1 I0X6 175 51 173 Units 104 4 S-1 10X6 175 77 177 Units 104 5 S-1 1 OX6 175 95 168 Units 104 6 8-1 I0X6 175 53 170 Units 104 7 S-1 1 OX6 175 69 179 Units 104 8 S-1 I0X6 175 63 183 Units 104 9 S-1 I0X6 200 175 199 Units 104 10 S-1 1 OX6 175 207 188 Units 104 11 S-1 1 OX6 200 64 195 SUPPLY TOTAL 2000 1993 Remarks: ANSIALM31= MILUIAM Q HAW t, TEE A Test Date: 07-23-2018 Readings By: Chilleml Page 2 of 12 ANIL - System Unit Test Report Split Project: Uncle Bob's Self Storage Location: 853j3.U8Hwy 1.Port St. Lucie, Florida System: FC-2/HP-2 Make Carrier Make/Frame Marathon / NA Make Sheave Direct Drive Full Load Amps/S.F. 6.8 / NA Sheave Diam/Bore NAP Make Sheave Direct Drive No. Belts/Size NAP Sheave Diam/Bore NAP pe Heating Section Reverse Cycle TNA Compressor Model No. ZP51KCETF5 NAP Compressor Serial No. 18A4843FL NAP Outside Air DBNVB 90.1180.0 Return Air DBNVB NA 72.8162.6 Entering Air DB/WB NA 77.2/67.1 Condensor Fan HP 1/4 Leaving Air DBAIVB NA 57.0156.4 No. of Fans/Fan RPM 1/1100 Fan RPM NA 1075 Condensor Fan Amps 1.52 test Date: 07-23.2018 Readings By: Chi|lemi Page 3of12 Project: Uncle Bob's Self Storage Location: 8531 S. US Hwy 1, Port St. Lucie, Florida Air Outlet Test Report System: FC-2 Test Apparatus: Flowhood k 4a,Servedl t �`�oohrNumdi+r No �TYPa� � 5ize�' at Jgn PfehPfellm,�+ F1�eemadce, Units 104 1 S-1 10X6 200 43 199 Units 104 2 S-1 10X6 175 97 173 Units 104 3 S-1 10X6 200 104 212 Units 104 4 S-1 10X6 175 273 177 Units 104 5 S-1 10X6 175 264 179 Units 104 6 S-1 10X6 175 87 184 Units 104 7 S-1 10X6 175 63 161 Units 104 8 S-1 10X6 175 99 174 Units 104 9 S-1 10X6 175 94 171 Units 104 10 S-1 10X6 200 57 202 Units 104 11 S-1 10X6 175 53 165 SUPPLY TOTAL 2000 1997 Remarks: Test Date: 07-23-2018 Readings By: Chillemi Page 4 of 12 AMIL .AMEEWWIP� AABC Project: Uncle Bob's Self Storage Location: 8531 S. US Hwy 1, Port St. Lucie, Florida Spilt System Unit Test Report w System: FC-3/HP-3 V- Make Carrier Make/Frame Marathon NA 'Model Number FV4CNB006 H.P./RPM %/1076 Serial Number 0618F0B558 Volts/Phase/Hertz 208-230 /1 /60 Make Sheave Direct Drive Full Load Amps/S.F. 6.8 / NA Sheave Diam/Bore NAP Make Sheave Direct Drive No. Belts/Size NAP Sheave Diam/Bare NAP No. Filters/Size (1) 21X23X1 Sheave CL Distance NAP Type Heating Section Reverse Cycle i2M ia-�ED 064010PO 9_ Supply Air CFM 2000 1986 Condensor Manufacturer Carder Outside Air CFM 525 533 Condensor Model No. 26HCE460A Return Air CFM 1475 1453 Condensor Serial No. 0518E23346 Compressor Model No. ZP51KCETF5 NA Compressor Serial No. 13SL122FL NAP Outside Air DBMS NA 90.1/80.0 Return Air DBAAfB NA 73.0162.7 Entering Air DBAAIB NA 77.6/67.3 Condensor Fan HP Leaving Air DB/WB NA 57.0156.0 No. of Fans/Fan RPM 11/1100 Cond Fan Volt/Phase/Hz 208-230/1 /60 Fan RPM NA 1075 Condensor Fan Amps 1.52 Motor Voltage TI T2 T3 208 200 Compr. Volts TI T2 T3 200-201-200 NAP Motor Amperage TI T2 T3 6.8 5.7 Compr. Amps TI T2 T3 15.2 15.4 15.2 NAP Remarks: rAft"Nfl o MAMAMN= 0 CMLUAM Q HALM ARE 91. - - , 09 29 Test Date: 07-23-2018 Readings By: Chillemi Page 5 of 12 NW AABC Project: Uncle Bob's Self Storage Location: 8531 S. US Hwy 1, Port St. Lucie, Florida Air Outlet Test Report System: FC-3 Test Apparatus: Flowhood Area`ServEdl r 3 ,� x loam Number 1 ,z _.Yfm ='g✓v- �.t.� �s.?`�"-,..-.k No i u''.p J pe ,r r —0l..... size 3 Derr n 9 _1m rtFM` s P i CPM Pre ilm 3£CFM y7 r FirlaI CFM `M marker . µ� k Units 104 1 S-1 10X6 200 272 194 Units 104 2 8-1 10X6 175 184 165 Units 104 3 6-1 10X6 175 255 178 Units 104 4 S-1 10X6 175 223 171 Units 104 5 S-1 10X6 175 263 181 Units 104 6 8-1 10X6 175 165 173 Units 104 7 S-1 10X6 175 234 179 Units 104 8 S-1 10X6 175 87 181 Units 104 9 S-1 10X6 200 92 189 Units 104 10 S-1 10X6 176 83 173 Units 104 11 S-1 10X6 200 74 202 SUPPLY TOTAL 2000 1986 Remarks: Wt L s n N� C. LME HALM 91. .092- Test Date: 07-23-2018 Readings By: Chillemi Page 6 of 12 Project: Uncle Bob's Self Storage Location: 8531 S. US Hwy 1, Part St. Lucie, Florida Split System Unit Test Report FC-gHP-4 Make Carrier Make/Frame Marathon / NA Make Sheave Direct Drive Full Load Amps/S.F. 6.8 / NA Sheave Diam/Bore NAP Make Sheave Direct Drive No. Belts/Size NAP Sheave Diam/Bore NAP No. Filters/Size (1) 21X23X1 Sheave CL Distance NAP Type Heating Section Reverse Cycle Compressor Model No. ZP51KCETFB NAP Compressor Serial No. 18AB414FL NAP Outside Air DBMB NA 90.1180.0 Return Air DBNVB NA 72.5/62.4 Leaving Air DBANB NA 52.8162.0 No. of Fans/Fan RPM II1100 Fan RPM NA 1075 Condensor Fan Amps 1.52 Test Date: 07^23^2018 Readings By: Ch0enli PoQa7of12 Project: Uncle Bob's Self Storage Location: 8531 S. US Hwy 1, Port St. Lucie, Florida Air Outlet Test Report System: FC-4 Test Apparatus: Flowhood k C Flff pi,00, vil W"M --l"0 IN"' M-5 Units 104 1 S-1 10X6 170 93 179 Units 104 2 SA 10X6 170 51 174 Units 104 3 S-1 10X6 170 99 170 Units 104 4 S-1 10X6 170 73 172 Units 104 5 S-1 10X6 165 64 168 Units 104 6 S-1 10X6 165 85 169 Units 104 7 S-1 10X6 165 82 170 Units 104 8 S-1 10X6 165 71 153 Units 104 9 S-1 10X6 165 264 159 Units 104 10 S-1 10X6 165 312 167 Units 104 11 S-1 10X6 165 33 161 Units 104 12 S-1 10X6 165 94 167 SUPPLY TOTAL 2000 2009 Remarks: rAMWN :01MEW 1qW JI&AMEMOU MLUAM C. HALM kh, TEE J 91 Test Date: 07-23-2018 Readings By: Chillemi Page 8 of 12 Project: Uncle Bob's Self Storage Location: 8531 S. US Hwy 1, Port St. Lucie, Florida Split System Unit Test Report System: FC-5/HP-5 NX Make Carrier Make/Frame Marathon / NA Model Number FV4CNB006 H.P./RPM- %/1075 Serial Number 0518F24888 Volts/Phase/Hertz 208-230 /1 / 60 Make Sheave Direct Drive Full Load Amps/S.F. 6.8 / NA Sheave Diam/Bore NAP Make Sheave Direct Drive No. Belts/Size. NAP Sheave Dlam/Bore NAP No. Filters/Size (1)21X23XI Sheave CL Distance NAP Type Heating Section Reverse Cycle 9v IPWA POP Ifd en90XA?AI*I' F-C -.-I V_ 9 Supply Air CFM 2000 1938 Condensor Manufacturer Carrier Outside Air CFM 525 503 Condensor Model No. 25HCE460A Return Air CFM 1475 1435 Condensor Serial No. 051BE16570 Compressor Model No. ZP51KCETF5 NAP Compressor Serial No. 118A4806FL NAP Outside Air DBMB NA 90.1/80.0 Return Air DB/WB NA 73.5/63.6 Entering Air DBNVB NA 77.8/67.9 Condensor Fan HP Leaving Air D8AAfB NA 57.5/66.9 No. of Fans/Fan RPM 1/1100 Cord Fan Volt/Phase/Hz 208-230 / I / 60 Fan RPM NA 1075 Condensor Fan Amps 1.52 Motor Voltage TI T2 T3 208 200 Compr. Volts T1 T2 T3 200-201-200 NAP Motor Amperage Ti T2 T3 6.8 8.2 Compr. Amps TI T2 T3 14.7 14.9 14.7 NAP Remarks; -0 91 � 094 Test Date: 07-23-2018 Readings By: Chill6ml Page 9 of 12 Project: Uncle Bob's Self Storage Location: 8531 S. US Hwy 1, Port St. Lucie, Florida Air Outlet Test Report System: FC-5 Test Apparatus: Flowhood -, � Area Served,[. `� �s �, ., v ... �.n'.Y n .r.-. ..—s .. .. Nai • �,rtypa� �. �s �ize'� �D@sjg�� pr�l�m ;Pretlrr� Diu .. �--v .. �F nal =_ • � % „Remarks - wi n v.... Units 104 1 S-1 10X6 200 89 194 Units 104 2 S-1 1oX6 175 59 162 Units 104 3 S-1 10X6 200 163 180 Units 104 4 S-1 10X6 175 72 177 Units 104 5 S-1 10X6 175 88 175 Units 104 6 S-1 10X6 175 91 159 Units 104 7 8-1 10X6 175 263 170 Units 104 8 S-1 Me 175 194 171 Units 104 9 S-1 1oX6 175 63 184 Units 104 10 8-1 1oX6 200 74 187 Units 104 11 S-1 1oX6 175 77 179 SUPPLY TOTAL 2000 1938 Remarks: Wrim,, Agkw +0 a 1 \ 113E / I 97,09.22 Test Date: 07-23-2018 Readings By: Chillemi Page 10 of 12 Project: Uncle Bob's Self Storage Location: 8531 S. US Hwy 1, Port St. Lucie, Florida Air Outlet Test Report System: Exhaust Fans Test Apparatus: Flowhood ea'Se tl/ No Typp Size pe�s�gr Prelims Pnllr Flnel Remarks EF-1 150 144 144 EF-2 150 148 148 Remarks: Test Date: 07-23-2018 Readings By: Chillemi Page 11 of 12 Instrument Calibration Report Project: Uncle Bob's Self Storage, 8531 S. US Hwy 1, Port St. Lucie, Florida r Instriitment� .-- ;tNanufacturer� Ilocel BenalNumber�,-"ngersrat�n Id 20 db to 140 db 01-29-18 Sound LevetMetef ' Quest Tea 2900 HWB070002 Octave Band Analyzer Quest Tech 2900 HWBO70002 31.5 to 16khz 01-29-18 Sound Level Calibrator Quest Tech QC-10/20 QIB070041 lkhz (114db) 01-29-18 Vibration Meter Quest Tech VI-100 QHB110007 .01-19.99 in/sec 01-29-18 Hydrodata Multimeter Shortridge HDM-300 W94078 .01" to 150 psi 02-16-18 Transit Time Flowmeter Polysonics DCT7088 B02KCO23 0 TO 50 R/sec NAP Flowhood Shortridge ADM-860 M88982 20 to 2500 CFM 10-04-17 Velometer Shortridge ADM-860 M88982 0 to 30000 FPM 10-04-17 Pyrometer Fluke 52 K/J 474502 -328 to +1400 F 12-21-17 Electronic Tachometer Pioneer 36 357M 0 to 12000 RPM 12-21-17 VolUAmpmeter AWS DSA2007 DD712313 0 to 600 amps 12-13-17 Duct Leakage Kit United McGill LTK-8 NA NA NAP Digital Light Meter Greenlee 93-172 00000826 .01 to 5000 Fe NAP Mercury Thermometer Taylor 6301 NAP -40 to +120 F NAP Mercury Thermometer Taylor 630 NAP 0 to +220 F NAP Dial Thermometer Universal H23-039 NAP -40 to +120 F NAP Dial Thermometer Universal H23-040 NAP 0 to +220 F NAP Incline Manometer Dwyer 100.5 3575-1 0" to 1.0" NAP Incline Vertical Manometer Dwyer 400-51- 3575-2 0" to 5.0" NAP U-Tube Manometer Dwyer 1223-36WM 3575-8 0" to 36.0" NAP Pilot Tube Dwyer NAP 3575-3 18" NAP Pilot Tube Dwyer NAP 35754 36" NAP VelGdd Shortridge VLG84 1406-7 14"X14" NAP VelProbe Shortridge SVP18 1406-8 18" NAP Magnehelic Gauge Dwyer 2000-0 R70902CS73 0"tow NAP Magnehelic Gauge Dwyer 2001 R8062311I67 Onto 1" NAP Magnehelic Gauge Dwyer 2005 R8042511128 0" to 5" NAP Remarks: �-y%I � 2 WR JAM C. HALM TEE 9r-09-22 Test Date: 07-23-2018 Readings By: Chillemi Page 12 of 12