HomeMy WebLinkAboutDESIGN CALCULATIONSEasy Seals easyseals.com DESIGN CALCULATIONS 6UANNED FOR BY St. Lucie Countv NEXAIR WALL -MOUNTED SIGNS 7466 Commercial Cir - Fort Pierce GENERAL NOTES: 1. Design is in accordance with the Florida Building Code 5th Edition (2014) for use within and outside the High Velocity Hurricane Zone (HVHZ). 2. Wind loads have been calculated per the requirements of ASCE 7-10 as shown herein. 3. These engineering calculations pertain only to the structural integrity of those systems, components, and/or other construction explicitly specified herein and/or in accompanying engineering drawings. The existing host index: structure (if any) must be capable of supporting the loaded system as Pg 1 cover verified by building department or architect / engineer of record. No Pg 2 wind toads warranty, either expressed or implied, is contained herein. Pg 3 Anchor Design 4. System components shall be as noted herein: All references to named components and installation shall conform to manufacturer's or industry specifications as summarized herein. 5. Where site conditions deviate from those noted herein, revisions maybe required or a separate site -specific engineering evaluation performed. Engi i! t r obi � 6. Aluminum components in contact with steel or embedded in concrete shall o� .t. be protected as prescribed in the 2010 Aluminum Design Manual, Part 1. No. 67 8 Steel components in contact with, but not encased in, concrete shall be = *: coated, painted, or otherwise protected against corrosion. 7. Engineer seal affixed hereto validates structural design as shown only. Use TATE '��00 . OC 2 of this specification by contractor, et. Al, indemnifies and saves harmless Chrisfil this engineer for all costs & damages including legal fees & apellate fees resulting from deviation from this design. Easy S�WSinrm sdL t valid # 67382 # 31124 Federal Hwy, g200 EasSeals.com Page 1 Bocaoca Raton, y ton, FL 33432 1 ' EasySeaLs /SCE 7-10 Design Wind Loads WALL -MOUNTED SIGNS Building Specs V = . 160 mph ( Basic wind speed Exposure' C Calculations a=9.5 3-sec gust speed power law exponent zg = 900' Nominal ht. of atmos. boundary layer Gcpi = 0 Internal pressure coeff CALCULATION, '011 WALL -MOUNTED SIGNS ASD Load Combo Coeff: 0.6 Kd = 0.85 Directionalityfactor Kzt=i- 1.0 _ �Topographicfactor A =; 10 sq ft ,Tributaryarea ivv mN11 - LAIJ a WALL -MOUNTED SIGNS ASD WIND PRESSURES SIGN HEIGHT CENTER (Zone 4) CORNER (Zone 5) Y Y qz U v U 9 15 ft 31.2 psf 39.7 psf 0.85 47.3 -1.10 -1.40 20 ft 33.2 psf 42.2 psf 0.90 50.2 -1.10 -1.40 25 ft 34.8 psf 44.2 psf 0.95 52.7 -1.10 -1.40 30 ft 36.1 psf 46.0 psf 0.98 54.7 -1.10 -1.40 35 ft 37.3 psf 47.5 psf 1.01 56.5 -1.10 -1.40 40 ft 38.4 psf 48.8 psf 1.04 58.1 -1.10 -1.40 45 ft 39.3 psf 50.1 psf 1.07 59.6 -1.10 -1.40 Soft 40.2 psf 51.2 psf 1.09 60.9 -1.10 -1.40 55 ft 41.0 psf 52.2 psf 1.12 62.2 -1.10 -1.40 60 ft 41.8 psf 53.2 psf 1.14 63.3 -1.10 -1.40 70 ft 35.3 psf 70.6 psf 1.17 65.4 -0.90 -1.80 80 ft 36.3 psf 72.6 psf 1.21 67.3 -0.90 -1.80 90 ft 37.2 psf 74.5 psf 1.24 69.0 -0.90 -1.80 100 ft 38.1 psf 76.1 psf 1.27 70.5 -0.90 -1.80 110 ft 38.8 psf 77.7 psf 1.29 71.9 -0.90 -1.80 120 ft 39.6 psf 79.1 psf 1.32 73.3 -0.90 -1.80 130 ft 40.2 psf 80.5 psf 1.34 74.5 -0.90 -1.80 140 ft 40.9 psf 81.7 psf 1.36 75.7 -0.90 -1.80 150 ft 41.5 psf 82.9 psf 1.38 76.8 -0.90 -1.80 175 ft 42.8 psf 95.7 psf 1.42 79.3 -0.90 -1.80 200 ft 44.1 psf 88.1 psf 1.46 81.6 -0.90 -1.80 250 ft 46.2 psf 92.3 psf 1.53 85.5 -0.90 -1.80 Page 2 EasySeals Wall Sign Anchor Design Structure Dimensions & Loading CALCULATION!' DR WALL -MOUNTED SIGNS Design wind pressure: P=i_ 46.0 Ipsf Sign type: Raceway Sign size: h 36.0 inches (height) Wall material: Metal '.Steel studs or extrusions/shapes Anchor type/size: #10 SMS Ref: Min 18ga studs (grd 33) or 0.090" 6063-T6 Min Embedment: Full Min edge dist: 0.75" Anchor tensile capacity: Tcap = 115.8 lb (per anchor) Check Anchors for Pullout Total Reaction: Rt = 138 Ib/ft ... = P•h (along raceway) Anchor spacing req'd s = 20.2 in O.C. ... = (2*Tcap)/Rt Pairs of anchors at 20 inches on center (max) 1.7 feet on center Ok, typical anchor option shown (qualifies 3/16" pop rivets). Ref anchor schedule for other anchor options. Page 3