HomeMy WebLinkAboutPRODUCT EVALUATIONi Intertek. g O a. W W jI,1ANNtL BY St. Lucie Cmint, REPORT NUMBER: 100810057MID-002C ORIGINAL ISSUE DATE: July 12, 2012 REVISED DATE: N/A EVALUATION CENTER Intertek 8431 Murphy Drive Middleton, VVI 53562 RENDERED TO Glen Raven Technical Fabrics 1821 North Park Ave Glen Raven, NC 27217 PRODUCT EVALUATED: Patio EVALUATION PROPERTY: NFPA 701-10, Method 2 Report of testing Patio for compliance with the applicable requirements of the following criteria: NFPA 701-10, METHOD 2 Standard Methods of Fire Tests for Flame Propagation of Textiles and Films -This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client Is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not Imply that the material, product, or service is or has ever been under an Intertek certification program." Glen Raven Technical Fabrics July 12, 2012 Report No. 100810057MID-002C Page 2 of 6 1 Table of Contents 1 TABLE OF CONTENTS...........................................................................................2 2 INTRODUCTION...................................................................................................... 3 3 TEST SAMPLES......................................................................................................3 3.1. SAMPLE SELECTION...................................................................................... 3 3.2. SAMPLE AND ASSEMBLY DESCRIPTION.....................................................3 4 TESTING AND EVALUATION METHODS..............................................................3 4.1. TEST STANDARD 1......................................................................................... 3 5 TESTING AND EVALUATION RESULTS................................................................4 5.1. RESULTS AND OBSERVATIONS....................................................................4 6 CONCLUSION......................................................................................................... 5 Intertek Glen Raven Technical Fabrics Report No. 100810057MID-002C 2 Introduction July 12, 2012 Page 3 of 6 Intertek has conducted testing for Glen Raven Technical Fabrics, on Patio to assess the propagation of flame beyond the area exposed to the ignition source. Testing was conducted in accordance with NFPA 701-10, Method 2 - Standard Methods of Fire Tests for Flame Propagation of Textiles and Films. This evaluation began July 11, 2012 and was completed July 11, 2012. 3 Test 3.1. SAMPLE SELECTION Samples were submitted to Intertek directly from the client. Samples were not independently selected for testing. Samples were received at the Evaluation Center July 5, 2012. 3.2. SAMPLE AND ASSEMBLY DESCRIPTION Four (4) pieces of Patio were prepared by client. Samples measuring 610 mm x 1200 mm t 25 mm were tested. Samples were conditioned in an oven at 105'C t 3'C for no less than 1 hour but no more than 3 hours before testing. 4 Testing and Evaluation Methods 4.1. TEST STANDARD 1 Four (4) specimens of material 24 in. x 47.25 in. are cut with their long dimension parallel to the length direction ("with" machine). The test specimens are conditioned to 220-225OF (105-1080C) for not less than one hour, and not more than 3 hours. Specimens are removed from the oven one at a time and tested immediately. The specimens are supported with clips in a three -sided vertical column and exposed to an 1 V flame for two minutes. The flame impinges approximately 7 inches on the specimen. No specimen shall continue flaming for more than two seconds. Length of char shall not exceed 41.3 inches from the bottom edge of the specimen. There shall be no flaming on the floor of the apparatus for longer than two seconds., Intertek Glen Raven Technical Fabrics Report No. 100810057MID-002C 5 and Evaluation Results 5.1. RESULTS AND OBSERVATIONS July 12, 2012 Page 4 of 6 Sample contracted away from the point of the flame. No other flaming events were observed. TEST RESULTS Specimen Afterflame Duration (sec) Floor Flaming (sec) Char Length (in.) 1 0 0 6.00 2 0 0 6.75 3 0 0 4.88 4 0 0 4.37 Average 0 0 5.50 The specimen passes the test criteria for NFPA 701-10, Method 2 Standard Methods of Fire Tests for Flame Propagation of Textiles and Films. . Glen Raven Technical Fabrics July 12, 2012 Report No. 100810057MID-002C Page 5 of 6 6 Conclusion Intertek has conducted testing for Glen Raven Technical Fabrics, to assess the propagation of flame beyond the area exposed to the ignition source. Testing was conducted in accordance with NFPA 701-10, Method 2- Standard Methods of Fire Tests for Flame Propagation of Textiles and Films. The specimen passes the test criteria of NFPA 701-10, Method 2 Standard Methods of Fire Tests for Flame Propagation of Textiles and Films. The conclusions of this test report may not be used as part of the requirements for Intertek product certification. Authority to Mark must be issued for a product to become certified. INTERTEK Reported by: Andrew Maximiuk Lab Technician i, Verification Center 9j� Reviewed by: Stewart Relyea Engineering Team Leader, Verification Center tlnterfelr Glen Raven Technical Fabrics Report No. 100810057MID-002C REVISION SUMMARY DATE SUMMARY July 12, 2012 -Original Report July 12, 2012 Page 6 of 6