Loading...
HomeMy WebLinkAboutPLAN REVIEW FORMSAINT LUCIE COUNTY FIRE DISTRICT v��u PLAN REVIEW FORM off. 5160 N.W. Milner Drive - Port Saint Lucie, FL 34983 x Telephone:772-621-3322 S(;ANNtL Fax: 772-621-3604 BY Web Address: www.slcfd.com St. Lucie Counts Building Dept. SLC FMO Permit# B-16-278 'Project Name New York Arcade BLDG Permit # 1608-0541 Address 6666 South US Hwy 1 City PSL Contractor TRB Contracting Address 7548 South US Hwy 1 City PSL State FL Zip 34952 Telephone (772)260-0758 Architect/Engineer Advanced Architect Telephone Occupancy Type Assembly Construction Type IIIB Square Feet 3081 Occupant Load Number of Stories Access Box Required Access Key Switch AFS Permit FA Permit FFP Permit JJ General Notes 1. An electronic copy ofthe construction documents submitted on a CD is required. The file format shall be.pdf only. 2. All revisions, Including the electronic copy must be received prior to permitting. 3. The Fire Marshal requires 24 hour notice on all inspections. 4. The respective Building Department shall schedule all final inspections through the Fire Marshal's Office. 5. Failed inspections require payment offeepriorto rescheduling of further inspections. 6. Penetrations through rated assemblies shall be of the proper UL design. Design criteria shall be submitted with the construction plans. 7. Fire alarm panels shall be located Indoors within air conditioned space. S. Plans and construction are subject to corrections in the field to maintain code compliance. 9. Automatic fan shutdown is required for HVAC system/s that exceed 2,000 cfm design capacity. 10. The Installation or Alteration of Fire Sprinklers, Fire Alarms, and Fixed Fire Protection Systems require a separate review and permit. THE FLORIDA FIRE PREVENTION CODE, 2012 EDITION IS CURRENTLY ENFORCED. BUILDINGS WITH LIGHT -FRAME TRUSS -TYPE CONSTRUCTION SHALL BE MARKED WITH APPROVED FIREFIGHTER SAFETY WARNING SIGNS IN ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODES 69A-3.012 AND 69A-60.0081 PRIOR TO RECEIVING A CERTIFICATE OF OCCUPANCY. bee trenerai notes Hoove ano nequirea nevisions oeruw 1. Portable fire extinguishers from a licensed contractor are required. Pageof 1❑ Reviewed by TonyJerger Date 11-04-16 1❑ rU,-- SAINT LUCIE COUNTY FIRE DISTRICT Jt,HIVIVEp 3 _MAC PLAN REVIEW FORM S'I��'; 5160 N.W. Milner Drive BY $ ` _s Port Saint Lucie, FL 34983 �r Lucie County Telephone:772-621-3322 Fax: 772-621-3604 Web Address: www.slcfd.com Building Dept. SLC FMO Permit # B-17-67 Project Name Newyork New York Arcade BLDG Permit# 1608-0541 Address 6666 South US Hwy 1 City PSL Contractor TRB Contracting Address 7548 South US Hwy 1 City PSL State FL Zip 34952 Telephone (772)260-0758 1 Architect/Engineer Advanced Architect Telephone Occupancy Type Assembly Construction Type 111E Square Feet 3081 Occupant Load Number of Stories Access Box Required Access Key Switch AFS Permit F FA Permit FFP Permit General Notes 1. An electronic copy of the construction documents submitted on a CD Is required. The file format shall be .pdf only. 2. All revisions, Including the electronic copy must be received prior to permitting. 3. The Fire Marshal requires 24 hour notice on all Inspections. 4, The respective Building Department shall schedule all final inspections through the Fire Marshal's Office. S. Failed Inspections require payment of fee prior to rescheduling of.further Inspections. 6. Penetrations through rated assemblies shall be of the proper UL design. Design criteria shall be submitted with the construction plans. 7. Fire alarm panels shall be located Indoors within air conditioned space. 8. Plans and construction are subject to corrections In the field to maintain code compliance. 9. Automatic fan shutdown is required for HVAC system/s that exceed 2,000 din design capacity. 10, The Installation or Alteration of Fire Sprinklers, Fire Alarms, and Fixed Fire Protection Systems require a separate review and permit. THE FLORIDA FIRE PREVENTION CODE, 2012 EDITION IS CURRENTLY ENFORCED. BUILDINGS WITH LIGHT -FRAME TRUSS -TYPE CONSTRUCTION SHALL BE MARKED WITH APPROVED FIREFIGHTER SAFETY WARNING SIGNS IN ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODES 69A-3.012 AND 69A-60.0081 PRIOR TO RECEIVING A CERTIFICATE OF OCCUPANCY. aee uenerai rvvtes noove anu neuwreu nevra,vns oe,uw 1. Portable fire extinguishers from a licensed contractor are required. 2. Panic hardware is required on all exit doors. Page i l of 1❑ Reviewed by TonyJerger Date 03-27-2017