Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEIr Ir \y ) rJag �Planning& Development Services Department `! NNE Building& Code Regulations Division- JVHNrYCD •3y 2300 Virginia Avenue, Fort Pierce, FL 34982- (772) 462-1553 BY Certification for Design Load Compliance St. LUde County Project Name: ,t /1L q Project Address: F 9 23 - ,6 1-/ J Permit M-J_WN-01 Z,6 Occupancy Type;�,v -s Construction Type:___ INSTRUCTIONS FOR USE: • This cenification must be completed, signed; and sealed by the design professional of record.. • Submit (2) copies for residential(3) copies for commercial with all permit applications involving the following: ily) o Any accessory structure remulinga bull RUM MW Ad"k 0 PAfty o Residential nd s (on a Any accessory dditlo Lure requiringa building permit ® Any non residential structure. ' Note: Form not required for Interior renovations provided that no exterior structural elements are affected and certain minor building permits at the gIscretian of the local building official. Contact the # above for questions, DESIGN PARAMETERS AND ASSUMPTIONS IISM (complete all that apply) 1. DESIGN CODE: Plorlda V� Code Fifth Edition with 20 t ly. Supplements using ASCE 740 2. Structure Designed as (check one): .Enclosed _Partially Enclosed }(' Open. 3. Risk Category: _ D .III _IV Exposure Category:._B _C _p 4. Design Wind velocity. 1'70 mph _A -ID -„LRFD End Zane. Width: ft 5. Mean Roof Height 5 ft Roof Fitch; ) ;12 Parapet: _ ft 6. Components& Cladding Design Pressures Used: (ESE, based on 10sgft@ISWRH, cleirly label on all plan openings): Zone 1:_ Zone 2: .Zone 3:. Zoned: Zane 5: Garage; . 7. Design Loads: Float P5F Roof/Dead: __PSF Rdof/Live:, 7-0 Balcony: PSF Dock: PSF Deckh..PSF Stairs: PSF'Fence: PSF Railings:: PSF & Were Shear Walls Considered' For .Strucure?__yes Not Applicable Explain Why Not: 9, Is A Continuous Load Path .Provided? -.k-YeS ,_,Not Applicable Ezpfain Why Not: 10. Design Soil Bearing Pressure; 35(7bPSf' Soil. Test Reports Submitted'1 DESIGN PROFESSIONAL CERTIFICATION STATEMENT: i certify that, to the best of my knowledge and belief, the attached,plans & specifications have been designed to comply with the applicable structural portions Of the building codes currently adopted and enforced by St:. Lucie County, I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Print Name Cert # & Co. CertAuth.. 7 SI , D to n Sea /dtMU�/�ry�lAl j �i 17gi f 0)ZLhMW, FL Company Name Si Address 32 e ns" Revised UT/25/201A. 7/r.+ \\,\\\\\\\llllllll// //,,,, P� N G N 3 3 STATE OF :1fzof;nvP' SS1ONAL ENG\\��� r� '"� 1910j7