Loading...
HomeMy WebLinkAboutREVIEW COMMENTSi Planning & Development Services Building& Code Regulation Division 2300 Virginia Avenue Fort Pierce;FL 34982 Phone:(772(462.2172 Fax:(772)462-6443 Address: 6023-6143 S U S 1 Project City / State / Zip: Fort Pierce, FI 34982 Parcel#: 3410-701-0006-000/2 Zoning: CG APPLICATION INFORMATION Permit Number: 1609-0126 Permit Type: COMMERCIAL ADDITION CONTRACTOR INFORMATION REVIEW COMMENTS 'UBy ED ;t Lucie Coanty 1 Owner(s): Fine Investment Properties Inc Jurisdiction: SAINT LUCIE COUNTY Lot#: 10 Block: Stories: Automatic Sprinkler System? No Contractor Name: Roderick J Waller Fax Number: 772-907-0420 Business Name: Sundse City Community Housing Development Org ' Inc Email: Rodwallerl@Gmail.Com Business Addr: 3550 Okeechobee Road ' City / State / Zip: Fort Pierce, FI 34947 REVIEWS AND COMMENTS Review Tyne Status Reviewed By Date Started Date Completed Date Released DOCUMENTS MISSING PENDING 9/8/2016 Comment: NEED ELECTRICAL, PLUMBING SUB & SUMMARY 10/5/2016 Comment: FILLED LANDS AFFIDAVIT. FRONT COUNTER REVIEW COMPLETE Lashahna Ingram 918/2016 9/812016 9/8/2016 Comment: PLANS EXAMINER ELECTRIC INCOMPLETE Walter Pride 10/1812016 10/18/2016 Comment: PLEASE ADD ALL RECPS.,FOR WASHERS,DRYERS,LIGHTING,SWITCHES,ETC.ALSO ELECTRICAL LOAD CAL.TO EXISTING PANEL,WALT PRIDE SR. PLANS EXAMINER PLUMBING INCOMPLETE Greg Smyth 912912016 9/29/2016 Comment: THIS IS A COMMERCIAL LAUNDRY FACICLITY PLEASE CLASSIFY OCCUPANT TYPE AND OCCUPANT COUNT PER SECTION 403.1 FPC 2014 9/29/2016 Comment: PLEASE SHOW THE REQUIRED RESTROOM FACILITIES REQUIRED PER TABLE 403.1 FPC 2014 9/29/2016 Comment: PLEASE SHOW THE REQUIRED FLOOR DRAINS REQUIRED PER SECTION 412.4FPC 2014 9/29/2016 Comment: PLEASE SHOW REQUIRED DRINKING FOUNTAINS PER TABLE 403.1 FPC 2014 9/29/2016 Comment: PLEASE SHOW SERVICE SINK PER TABLE 603.1 FPC 2014 PLANS EXAMINER REVIEW INCOMPLETE Joe Clcio 912812016 Comment: SUBMIT [ 31 ST LUCIE COUNTY "CERTIFICATION FOR DESIGN LOAD COMPLIANCE" SHEETS 9/28/2016 COMPLETELY FILLED OUT W/ ORIGINAL SIGNATURE, DATED AND SEALED BY THE ENGINEER OF RECORD THESE ARE AVAILABLE ON THE ST LUCIE COUNTY PERMIT WEBSITE Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982. Phone:(772)462-2172 Fax:(772)462�6443 REVIEW COMMENTS 9/28/2016 Comment: " SUBMITTED PLANS DO NOT MATCH WHAT HAS BEEN CONSTRUCTED " Comment: SUBMIT A SIGNED, SEALED AND DATED ORIGINAL SOIL TEST TESTED TO THE REQUIRED 2000 PSF BY 9/28/2016 THE ENGINEER Comment: EXTERIOR WALLS MUST BE DESIGNED PER FBC 2304' PLANS SPEC T & G • SHOW THE REQUIRED WALL 9/28/2016 STUD SPACING PER 2304.6 9/28/2016 Comment: ENGINEER TO DESIGN THE WINDOW BUCK/ FRAMING ON PLANS WITH THE INFILLS Comment: SUBMIT [ 3 ] ST LUCIE COUNTY PRODUCT REVIEW AFFIDAVITS FOR THE EXTERIOR WINDOWS / GLAZING 9/2812016 AND SWING DOORS THAT WERE REPLACED • THESE MUST BE SIGNED, SEALED AND DATED BY THE ENGINEER 9/28/2016 Comment: ENGINEER TO DESIGN ALL OF THE SISTERING OF THE EXISTING ROOF RAFTERS ON PLANS ` SHOW ALL STRAPPING AND FASTENERS Comment: ENGINEER TO SHOW THE ROOF ASSEMBLY ON THE PLANS W/ SHEATHING, WEATHER BARRIERS AND 9/28/2016 ROOF COVERING MATERIAL SPECIFICATIONS 9/28/2016 Comment: ENGINEER TO STATE THE CORRECT REFERENCE STANDARD NUMBERS ON A-2 FROM THE 2014 BUILDING CODE CHAPTER 35 • REMOVE ALL STRUCTURAL NOTES THAT DO NOTAPPLY TO THIS PROJECT Comment: DETAIL ON A-2 STATES TO SEE ROOF TRUSS LAYOUT FOR SPECIFICATIONS `THERE ARE NO 9/28/2016 STRAPPING, TRUSS ANCHOR OR FASTENER SPECIFICATIONS ON PLANS' ENGINEER IS SHOWING THE PERIMETER BEAMS HANGING OFF OF THE COLUMNS IN THE DETAIL Comment: PLAN SHEET A-1 IS SPECIFYING 2500 PSI CONCRETE AND A-2 IS SPECIFYING 3000 PSI ?? ENGINEER TO 9/28/2016 CLARIFY Comment: DESIGN PROFESSIONAL TO CLASSIFY THIS FACILITY ON PLANS PER FBC CHAPTER 3 • SHOW 9/28/2016 CONSTRUCTION TYPE, OCCUPANT LOAD, OCCUPANCY CLASSIFICATION ETC ON PLANS 10/13/2016 Comment: ENGINEEER TO SHOW THE LOCATION OF THE MALTESE CROSS ON PLANS AS REQUIRED BY F.A.C.69A- 60.0081 10/19/2016 Comment: UPON RE -SUBMITTAL PLEASE SUBMIT[ 31 SETS OF ORIGINAL, SIGNED, SEALED AND DATED PLANS W/ [ 2 ] PDF DISCS 10/19/2016 Comment: COMMENTS E-MAILED TO CONTRACTOR AS OF THIS DATE ZONING REVIEW INCOMPLETE Lydia Galbraith 10/512016 10/5/2016 Comment: PLEASE PROVIDE PLOT PLAN TO SCALE SHOWING EXISTING LAUNDRY, PROPOSED PORCH ADDITION AND SETBACKS. SIDE STRUCTURE TO STRUCTURE, FRONT TO THE EDGE OF THE ROAD. Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462-2172 Fax:(772)462-6443 PROPERTY INFORMATION Address: 6023-6143 S U S 1 Project City / State I Zip: Fort Pierce, FI 34982 Parcel#: 3410-701-0006-000/2 Zoning: CG APPLICATION INFORMATION Permit Number: 1609-0126 i Permit Type: COMMERCIAL ADDITION 1 i CONTRACTOR INFORMATION Contractor Name: Roderick J Waller 4 REVIEW COMMENTS S(;B� EV St Lucie COunti Page 1 Owner(s): Fine Investment Properties Inc Jurisdiction: SAINT LUCIE COUNTY Lot#: 10 Stories: Business Name: Sunrise City Community Housing Development Org Inc Business Addr: 3550 Okeechobee Road City / State / Zip: Fort Pierce, FI 34947 Block: Automatic Sprinkler System? No Fax Number: 772-907-0420 REVIEWS AND COMMENTS Review Type Status Reviewed By Date Started DOCUMENTS MISSING PENDING 9/8/2016 Comment: NEED ELECTRICAL, PLUMBING SUB & SUMMARY 10/612016 Comment: FILLED LANDS AFFIDAVIT. FRONT COUNTER REVIEW COMPLETE Lashahna Ingram 918/2016 Comment: PE REVIEW COMMENTS (2) Comment: 9/28/2016 Comment: 9/28/2016 9/28/2016 Comment: Comment: 9/2812016 9/28/2016 Comment: 9/28/2016 Comment: 10/19/2016 Comment: INCOMPLETE Joe Ciclo 1211312016 Email: Rodwallerl@Gmail.Com Date Completed Date Released 9/812016 91812016 SUBMIT [ 3 ) ST LUCIE COUNTY" CERTIFICATION FOR DESIGN LOAD COMPLIANCE" SHEETS COMPLETELY FILLED OUT WI ORIGINAL SIGNATURE, DATED AND SEALED BY THE ENGINEER OF RECORD ' THESE ARE AVAILABLE ON THE ST LUCIE COUNTY PERMIT WEBSITE'• DID NOT RECEIVE •` SECOND REVIEW SUBMITA SIGNED, SEALED AND DATED ORIGINAL SOIL TEST TESTED TO THE REQUIRED 2000 PSF BY THE ENGINEER •• DID NOT RECEIVE "SECOND REVIEW" CONTRACTOR TO SUBMIT VERIFICATION PER PLAN NOTES ENGINEER TO DESIGN THE WINDOW BUCK / FRAMING ON PLANS WITH THE INFILLS " NOT ON PLANS " SECOND REVIEW SUBMIT [ 3 ] ST LUCIE COUNTY PRODUCT REVIEW AFFIDAVITS FOR THE EXTERIOR WINDOWS / GLAZING AND SWING DOORS THAT WERE REPLACED • THESE MUST BE SIGNED, SEALED AND DATED BY THE ENGINEER •' DID NOT RECEIVE "SECOND REVIEW ENGINEER TO DESIGN ALL OF THE SISTERING OF THE EXISTING ROOF RAFTERS ON PLANS' SHOW ALL STRAPPING AND FASTENERS •• NOT ON PLANS "SECOND REVIEW ENGINEER TO SHOW THE ROOF ASSEMBLY ON THE PLANS W/ SHEATHING, WEATHER BARRIERS AND ROOF COVERING MATERIAL SPECIFICATIONS" NEED ROOF COVERING SPECS ON AFFIDAVIT UPON RE -SUBMITTAL PLEASE SUBMIT [ 31 SETS OF ORIGINAL, SIGNED, SEALED AND DATED PLANS W/ [ 2 1 PDF DISCS Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Fox:(772)462.6443 12/13/2016 Comment: 12/13/2016 Comment: 12113/2016 Comment: 12121/2016 Comment: PLANS EXAMINER ELECTRIC 10/18/2016 Comment: PLANS EXAMINER PLUMBING Comment: PLANS EXAMINER REVIEW Comment: REVIEW COMMENTS 2 NEW PLANS SHOW [ 3 ] TYPES OF UP -RIGHT COLUMNS • PLEASE SELECT THE ONE PROPOSED WITH THE CORRESPONDING ATTACHMENT PLEASE DIMENSION THE LAUNDRY ROOM ON PLANS • S CLASSIFICATION IS NOT CORRECT • 2010 FLORIDA FIRE CODE IS INCORRECT ] SHOULD BE 5TH EDITION ] COMMENTS COMPLETE 12/13/2016 • PENDING RE -SEND RE -SENT COMMENTS • PENDING ELECTRIC REVIEW • 12121/2016 INCOMPLETE Walter Pride 10/18/2016 PLEASE ADD ALL RECPS.,FOR WASHERS,DRYERS,LIGHTING,SWITCHES,ETCALSO ELECTRICAL LOAD CAL.TO EXISTING PANEL,WALT PRIDE SR. COMPLETE Greg Smyth 9/2912016 1211412016 1211412016 COMPLETE Joe Cicio 9/2812016 12113/2016 12/1312016 ZONING REVIEW INCOMPLETE Lydia Galbraith 10/612016 Comment: PLEASE PROVIDE PLOT PLAN TO SCALE SHOWING EXISTING LAUNDRY, PROPOSED PORCH ADDITION AND SETBACKS. SIDE STRUCTURE TO STRUCTURE, FRONT TO THE EDGE OF THE ROAD. 10/5/2016 12/19/16 RECEIVED AND REVIEWED SURVEY. - LAUNDRY BUILDING NOT MATCHING WITH THE BUILDING PLANS, NO DIMENSIONS,NO INDICATION OF PROPOSED PORCH. - SETBACKS NOT ADDRESSED Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Fax:(772)462;6443 PROPERTY INFORMATION Address: 6023-6143 S U S 1 Project City / State / Zip: Fort Pierce, FI 34982 Parcel#: 3410-701-0006-000/2 Zoning: CG APPLICATION INFORMATION Permit Number: 1609-0126 Permit Type: COMMERCIAL ADDITION CONTRACTOR INFORMATION REVIEW COMMENTS S(,B� tb St. LUCIL'C01lnf- Owner(s): Fine Investment Properties Inc Jurisdiction: SAINT LUCIE COUNTY Lot#: 10 Block: Stories: Contractor Name: Roderick J Waller Business Name: Sunrise City Community Housing Development Org Inc Business Addr: 3550 Okeechobee Road City / State / Zip: Fort Pierce, FI 34947 1 Automatic Sprinkler System? No Fax Number: 772-907-0420 Email: Rodwallerl@Gmail.Com REVIEWS AND COMMENTS Review Type Status Reviewed By Date Started Date Com feted Date Released DOCUMENTS MISSING PENDING 9/8/2016 Comment: NEED ELECTRICAL, PLUMBING SUB & SUMMARY 10/512016 Comment: FILLED LANDS AFFIDAVIT. FRONT COUNTER REVIEW COMPLETE Lashahna Ingram 9/8/2016 9/812016 9/812016 Comment: i PE REVIEW COMMENTS (2) INCOMPLETE Joe Ciclo 12/1312016 Comment: SUBMIT [ 3 ] ST LUCIE COUNTY " CERTIFICATION FOR DESIGN LOAD COMPLIANCE " SHEETS 9/28/2016 COMPLETELY FILLED OUT W/ ORIGINAL SIGNATURE, DATED AND SEALED BY THE ENGINEER OF RECORD • THESE ARE AVAILABLE ON THE ST LUCIE COUNTY PERMIT WEBSITE.• DID NOT RECEIVE "SECOND REVIEW Comment: SUBMITA SIGNED, SEALED AND DATED ORIGINAL SOIL TEST TESTED TO THE REQUIRED 2000 PSF BY 9/28/2016 THE ENGINEER" DID NOT RECEIVE •• SECOND REVIEW •• CONTRACTOR TO SUBMIT VERIFICATION PER PLAN NOTES 9/28/2016 Comment: ENGINEERTO DESIGN THE WINDOW BUCK/ FRAMING ON PLANS WITH THE INFILLS •' NOT ON PLANS" SECOND REVIEW Comment: SUBMIT [ 3 ] ST LUCIE COUNTY PRODUCT REVIEW AFFIDAVITS FOR THE EXTERIOR WINDOWS / GLAZING 9/2812016 AND SWING DOORS THAT WERE REPLACED `THESE MUST BE SIGNED, SEALED AND DATED BY THE ENGINEER "DID NOT RECEIVE'• SECOND REVIEW 9/28/2016 Comment: ENGINEER TO DESIGN ALL OF THE SISTERING OF THE EXISTING ROOF RAFTERS ON PLANS `SHOW ALL STRAPPING AND FASTENERS — NOT ON PLANS'• SECOND REVIEW 9/28/2016 Comment: ENGINEER TO SHOW THE ROOF ASSEMBLY ON THE PLANS W/ SHEATHING, WEATHER BARRIERS AND ROOF COVERING MATERIAL SPECIFICATIONS •. NEED ROOF COVERING SPECS ON AFFIDAVIT 10/19/2016 Comment: UPON RE -SUBMITTAL PLEASE SUBMIT [ 3 ] SETS OF ORIGINAL, SIGNED, SEALED AND DATED PLANS W/ [2 1 PDF DISCS ,SLr.�i•.rile 4iozcn�c� Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Fex:(772)462.6443 12/13/2016 Comment: 12/13/2016 Comment: 12/13/2016 Comment: 12/21/2016 Comment: PLANS EXAMINER ELECTRIC 10/18/2016 Comment: PLANS EXAMINER PLUMBING Comment: PLANS EXAMINER REVIEW Comment: REVIEW COMMENTS 2 NEW PLANS SHOW[ 3 ] TYPES OF UP -RIGHT COLUMNS -PLEASE SELECT THE ONE PROPOSED WITH THE CORRESPONDING ATTACHMENT' PLEASE DIMENSION THE LAUNDRY ROOM ON PLANS' S CLASSIFICATION IS NOT CORRECT • 2010 FLORIDA FIRE CODE IS INCORRECT [ SHOULD BE 5TH EDITION ] COMMENTS COMPLETE 12113/2016' PENDING RE -SEND RE -SENT COMMENTS `PENDING ELECTRIC REVIEW • 12/21/2016 INCOMPLETE Walter Pride 10/18/2016 PLEASE ADD ALL RECPS.,FOR WASHERS,DRYERS,LIGHTING,SWITCHES,ETC.ALSO ELECTRICAL LOAD CAL.TO EXISTING PANEL,WALT PRIDE SR. COMPLETE Greg Smyth 912912016 1211412016 12/1412016 COMPLETE Joe Cicio 9/2812016 12/13/2016 1211312016 ZONING REVIEW INCOMPLETE Lydia Galbraith 101512016 Comment: PLEASE PROVIDE PLOT PLAN TO SCALE SHOWING EXISTING LAUNDRY, PROPOSED PORCH ADDITION AND SETBACKS. SIDE STRUCTURE TO STRUCTURE, FRONT TO THE EDGE OF THE ROAD. 10/5/2016 12/19/16 RECEIVED AND REVIEWED SURVEY. - LAUNDRY BUILDING NOT MATCHING WITH THE BUILDING PLANS, NO DIMENSIONS,NO INDICATION OF PROPOSED PORCH. - SETBACKS NOT ADDRESSED