Loading...
HomeMy WebLinkAboutREVISION 16UANNED BY ;t Lucie County April 13, 2017 St. Lucie County Building Department RE: International Diamond Center Interior Remodel 2014 Se Port St Lucie Blvd HEILMAN ARCHITECTURE Architecture Planning + Design' Heilman Architecture,.P.A. 999 Douglas Avenue Suite 2214 Altamonte Springs, Florida 32714 Tel. 407.493.3075 E-mail rsh(o)heilmanarch.com PARR Lucie, FI52 PARCEL 3414-501-01-5004-050/6 7RACTOR COPY Permit # 1610-0045 Dear Building Officials: .Please see the minor adjustments to the.original floor plans including: 1. Move break counter north on the same wall to accommodate the. HI-LO water cooler. 2. Relocation of watercooler for better access. 3. Open walls at room 116 Buying to accommodate adjusted cabinet locations. 4. None of the revisions affect fire egress and are accessible as shown. Sincerely, Heilman Architecture; P.A. Robert S. Heilman, AIA, NCARB, LEED AP, President Cc: File 4/14/2017 i suw%eU gt. December 22, 2016 St. Lucie County Building Department RE: International Diamond Center Interior Remodel 2010 Se Port St Lucie Blvd Port St Lucie, FI 34952 PARCEL 3414-501-5004-050/6 Permit # 1610-0045 Dear Building Officials: Please see comments and responses: Mechanical Comments (Carl Peterson): HEILMAN ARCHITECTURE Architecture Planning + Design Heilman Architecture, P.A. 999 Douglas Avenue Suite 2214 Altamonte Springs, Florida 32714 Tel. 407.493.3075 E-mail rsh(oheilmanarch.com PLEASE SHOW THAT AIR HANDLER UNITS ARE NOT IN WHAT IS CONSIDERED ATTIC SPACE IN ACCORDANCE WITH 403.2.7.6 OF THE 2014 FLORIDA ENERGY CODE RESPONSE: PER TEL COM WITH CARL, THE BUILDING/HVAC"SYSTEM IS EXISTING AND THE MECHANICAL REVISIONS ARE ADJUSTMENTS TO THE EXISTING DUCTS ONLY FOR SUPPLY AND RETURN LOCATIONS. THE EXISTING SYSTEM IS IN THE ATTIC. 2. ATTIC. AN ENCLOSED, UNCONDITIONED SPACE LOCATED IMMEDIATELY BELOW AN UNINSULATED ROOF AND IMMEDIATELY ABOVE THE CEILING OF A BUILDING. RESPONSE: PER TEL COM WITH CARL, THE BUILDING/HVAC SYSTEM IS EXISTING AND THE MECHANICAL REVISIONS ARE ADJUSTMENTS TO THE EXISTING DUCTS ONLY FOR SUPPLY AND RETURN LOCATIONS. THE EXISTING SYSTEM IS IN THE ATTIC. Building Comments (Greg Smith and Ed Roseberry) 3. PLEASE SHOW THE REQUIRED HI / LO DRINKING FOUNTAINS PER SECTION 211 OF THE FLORIDA ACCESSIBILITY CODE 2014. RESPONSE: SEE SHEET A2.1 WITH ADDED WATER COOLER AND SEE SHEETS A0.2 FOR COOLER DETAILS. It HEILMAN ARCHITECTURE Architecture Planning + Design 4. PLEASE SUBMIT TWO SETS OF FLORIDA PRODUCT APPROVALS OR NOA FOR ALL EXTERIOR DOOR AND/OR WINDOW REPLACEMENTS, PER FBC 107.2.1 RESPONSE: NO EXTERIOR WINDOWS OR DOORS IN THE SCOPE OF WORK 5. PLEASE INCLUDE REQUIRED PROJECT DESIGN PRESSURE REQUIREMENTS FOR ALL REPLACEMENT WINDOWS AND DOORS, PER FBC 107.2.1 RESPONSE: NO EXTERIOR WINDOWS OR DOORS IN THE SCOPE OF WORK 6. PLEASE NOTE BUSINESSES/OCCUPANCY USE ON BOTH SIDES OF PROJECT, PER FBC 107.2.1 RESPONSE: ADJACENT BUSINESS OCCUPANCY 7. PLEASE NOTE WHERE FIRE WALLS, WHICH ARE DETAILED ON SHEET A7.1, ARE BEING USED ON FLOOR RESPONSE: NO FIREWALL REVISIONS IN THE SCOPE OF WORK. 8. PLEASE SUBMIT COMMENT SUMMARY SHEET DETAILING RESPONSE TO EACH COMMENT RESPONSE: INCLUDED 9. PLEASE SUBMIT 2 UPDATED PDF COPIES OF PLANS ON 2 CD. RESPONSE: INCLUDED Sincerely, Heilman Architecture, P.A. Robert S. Heilman, AIA, NCARB, LEED AP, President Cc: File 12/29/2016 2 d,;N = 3 2911 SCANNED HEILMAN ARCHITECTURE BY Architecture Planning St. Lucie County + Design Heilman Architecture, P.A. 999 Douglas Avenue Suite 2214 Altamonte Springs, Florida 32714 Tel. 407.493.3075 E-mail rsh(c heilmanarch.com December 22, 2016 St. Lucie County Building Department RE: International Diamond Center Interior Remodel 2010 Se Port St Lucie Blvd Port St Lucie, FI 34952 PARCEL 3414-501-5004-050/6 Permit# 1610-0045 Dear Building Officials: Please see comments and responses: Mechanical Comments (Carl Peterson): PLEASE SHOW THAT AIR HANDLER UNITS ARE NOT IN WHAT IS CONSIDERED ATTIC SPACE IN ACCORDANCE WITH 403.2.7.6 OF THE 2014 FLORIDA ENERGY CODE RESPONSE: PER TEL COM WITH CARL, THE BUILDING/HVAC SYSTEM IS EXISTING AND THE MECHANICAL REVISIONS ARE ADJUSTMENTS TO THE EXISTING DUCTS ONLY FOR SUPPLY AND RETURN LOCATIONS. THE EXISTING SYSTEM IS IN THE ATTIC. 2. ATTIC. AN ENCLOSED, UNCONDITIONED SPACE LOCATED IMMEDIATELY BELOW AN UNINSULATED ROOF AND IMMEDIATELY ABOVE THE CEILING OF A BUILDING. RESPONSE: PER TEL COM WITH CARL, THE BUILDING/HVAC SYSTEM IS EXISTING AND THE MECHANICAL REVISIONS ARE ADJUSTMENTS TO THE EXISTING DUCTS ONLY FOR SUPPLY AND RETURN LOCATIONS. THE EXISTING SYSTEM IS IN THE ATTIC. Building Comments (Greg Smith and Ed Roseberry) 1<7A PLEASE SHOW THE REQUIRED HI / LO DRINKING FOUNTAINS PER SECTION 211 OF THE FLORIDA ACCESSIBILITY CODE 2014. RESPONSE: SEE SHEET A2.1 WITH ADDED WATER COOLER AND A0.2 FOR COOLER DETAILS. J;4N 32017 HEILMAN ARCHITECTURE Architecture Planning + Design 4. PLEASE SUBMIT TWO SETS OF FLORIDA PRODUCT APPROVALS OR NOA FOR ALL EXTERIOR DOOR AND/OR WINDOW REPLACEMENTS, PER FBC 107.2.1 RESPONSE: NO EXTERIOR WINDOWS OR DOORS IN THE SCOPE OF WORK 5. PLEASE INCLUDE REQUIRED PROJECT DESIGN PRESSURE REQUIREMENTS FOR ALL REPLACEMENT WINDOWS AND DOORS, PER FBC 107.2.1 RESPONSE: NO EXTERIOR WINDOWS OR DOORS IN THE SCOPE OF WORK 6. PLEASE NOTE BUSINESSES/OCCUPANCY USE ON BOTH SIDES OF PROJECT, PER FBC 107.2.1 RESPONSE: ADJACENT BUSINESS OCCUPANCY 7. PLEASE NOTE WHERE FIRE WALLS, WHICH ARE DETAILED ON SHEET A7.1, ARE BEING USED ON FLOOR RESPONSE: NO FIREWALL REVISIONS IN THE SCOPE OF WORK. 8. PLEASE SUBMIT COMMENT SUMMARY SHEET DETAILING RESPONSE TO EACH COMMENT RESPONSE: INCLUDED 9. PLEASE SUBMIT 2 UPDATED PDF COPIES OF PLANS ON 2 CD. RESPONSE: INCLUDED Sincerely, Heilman Architecture, P.A. Robert S. Heilman, AIA, NCARB, LEED AP, President Cc: File 12/29/2016 2