HomeMy WebLinkAboutTRUSS PAPPERSw
` Lumber design values are in accordance with ANSI/TPI 1-2007 section 6.3
A_1 ROOF - These truss designs rely on hlmber values established by_ -others.---- - - - --
TRUSSES
AFLORIDACORPORAmON
RE: Job 68633 A-1 Roof Trusses
4451 St Lucie Blvd
Site Information: Fort Pierce, FL 34946
Customer Info: CARE NET PREGNANCY SVC Project Name: CARE NET ADDITION
Lot/Block: Model: SCANNED
6704 S US 1, PORT ST LUCIE, FL Subdivision:
City: County: EXEMPT State: FL BY
Name Address and License # of Structural Engineer of Record, If there is one, for the buildingSt, Lucie Count%/
Name: License #:
Address:
City:
General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FBC2014frP12007 Design Program: MiTek 20/20 8.0
Wind Code: ASCE 7-10 Wind Speed: 160 MPH
Roof Load: 40.0 psf Floor Load: 0.0 psf
This package includes 4 individual, dated Truss Design Drawings and 0 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61Gl5-31.003,section 5 of the Florida Board of Professional Engineers Rules.
No.
Seal #
Truss Name
Date
I
A0005247
CA
-
5/15/17
2
A0005248
CJ3
5115117
3
A0005249 -
HJ5
5115117
4
A0005250
J5
5115117
The Architect's or Architect's representative's
shop drawing approval is NOT a
"double cheek" of the contractor.
The contractor shall remain responsible
for checking field measurements and
other construction criteria. Architect's
approval covers general roof shape,
review of truss strapping, and loading on
structure from gravity and uplift loads and
their Ias ti locations.
Approved By:,
Dale:
Brzeftrif & Braden A.I.A. P.A.
The truss drawing(s) referenced have been prepared by MTek Industries, Inc. under my direct supervis'on based on the parameters provided byA-1 Roof Trusses,
Ltd.
Truss Design Engineer's Name: Anthony Tombo III
My license renewal date for the state of Florida is February28,2019.
NOTE:The seal on these drawings indicate acceptance of professional
engineering responsibility solely for the truss components shown.
The suitability and use of components for any particular building is the responsibility of the
building designer, per ANSIfTPI-1 Sec. 2.
The Truss Design Drawing(s)(TDD[s]) referenced have been prepared based on the
construction documents (also referred to attimes as Structural Engineering Documents)
provided by the Building Designer indicating the nature and character of the work.
The design criteria therein have been transferred to Anthony Tombo III PE by [Al Roof
Trusses or specific location]. These TDDs.(alsoreferred to attimes as 'Structural
Engineering Documental are specialty structural component designs and may be part ofthe
projects deterred or phased submittals. As a Truss Design Engineer g.e., Specialty
Engineer), the seal here and on the Too represents an acceptance of professional Anthony T.
engineering responsibility for the design of the single Truss depicted on the TDD only. The
Building Designer is responsible for and shall coordinate and review the TODs for
compatibility with their written engineering requirements. Please review all TDDS and all
related notes.
Page 1 of 1
-'•)Yti ,}:rr,.:rgG. }n9tlSv:r,w. ... �.$::. nOT
t: 'e C:.i ai {.S v+.:r[Gn s�rvwntir yprS.�
ui', e•.:a07 U3 i !.. '>lJ"+!p •.4d W;!i'
-rid:r�IGgll `.t :P.I:fb�;4 lie. ;: tOE )4YHur75A 1'
A;u: r::-e=*;�+�+�c•t n- 1.1^„' +,n:r rrvn> rnl
r ..:•r lion,�. .: •i'r •: ti'; n :1. n. iu�f .n., n totitr.
,•K!L .<� trn*t h:a'.:v 5; ruvun iq e::r ,u r.
r- aq:bt. nt it r.r. .i:vxc::Y;•+t2 '.: rt`; V.r w•rr. •„
'6r•� rtf. o! )7+icp+ St rl:; qi.'+ ='Ir .norl a!+rf die q:
r: Mott G;r:rl •:. ':}•+q; a1'•+^1!
h,.q .AS r4 1: a ;;F J, :r ......
4
Job
Job
Truss
Tus
peOty
Ply
A0005247
POMTr Jack
q
Job Reference optional)
Al Koor Issas, con rler , rL Y ue , aeslgn(mal nu...r"
LOADING(psf)
SPACING-
2-0-0
TCLL
20.0
Plate Grip DOL
1.25
TCDL
10.0
Lumber DOL
1.25
BCLL
0.0 '
Rep Stress Incr
YES
BCDL
10.0
Code FBC2014/TP12007
LUMBER -
TOP CHORD- 2x4 SP No.2
BOT CHORD 2x4 SP No.2
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 0-11-11 oc
pudins.
BOTCHORD
Rigid ceiling directly applied or 6-M oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation gum
REACTIONS. (lb/size)
2 = 80/Mechanical
3 = O/Mechanical
Max Harz
2 = 68(LC 1)
3 = -68(LC 1)
Max Uplift
2 = -30(LC 8)
Max Grav
2 = 80(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vul1=160mph (3-second gust)
Vasd=124mph; TCDL=5.Opsf, BCDL=5.Opsf; h=1211;
Cat II; Exp C; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Extenor(2) zone; cantilever left and right
exposed ; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) Plates checked for a plus or minus 0 degree rotation
about its center.
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
-4)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-0-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 30lb uplift at joint
2. 1
nun: a.uzn s
CSI.
TC 0.07
BC 0.05
WE 0.00
Matrix -MP
LOAD CASE(S)
Standard
2x4 =
Iw
a
3
DEFL. in (loc) Udeft
Vert(LL) 0.00 6 n/r
Vert(TL) -0.00 6 n/r
Horz(TL) 0.00 n/a
L/d PLATES GRIP
90 MT20 2441190
80
n/a
Weight: 3lb FT = 0%
hmr mna.n}r mrmuuesea,uiulruwu n^mey'Iwsr7zra-mrrars..rnr,.,y�mm,am:.au o.,gb..gm.:.msl.�rrm.¢rt�..n�bs,M. m4.,m.a.ud.rw..e.
W'.,1 Wlbr.�mraYmin b,far LumuyhlYri Jea16Wi.NW IP.RMe,os,Aatl4P6Y.2^P mim+WR bkPabd?I rY b'Pl mleV RL A1nV^m Nt9i ,^Lti1
MthonY T. Ill. P.E.
mw1N 4 b4Mi5rsMnpiNytlb4 s.mEw Maiprs0.mbgtnp. mmCtldbC,6HmrLdFlS�m�m1I41 il,p:ntltlYn'olnlbd tlrN.titldgbryNgwSJa.mMagS9Ym;e:lo.H49
Mx83
WN3
h WallMrH(meb. irehMq b6BmYrymo MrKndM1lilm4petlW(IEma 3alruadhwm¢o M�YPdntar. nHKmb,: Nr,M[snob'xtf�uptlm,rJ�bgn¢mmu/duN4tleu
da51S G LiK128ivd.
amm.anip waynp ambal�m,nd.d rt4 h�yYpnnelbYYgbup 1 is. bl�agbMq lOmMmm nnidel4RVl
FUT Pierce, 1134946
� - (npplyY@ltlikl ledfieau laAmrl.lxals A;; Pi PzpNw6wdkirdxpima,omplarnp,Nh'vedxrlea0emmevra.'swetreakltodtnsus WHe,l.rom1a 14N
Job
Truss
TrussType
Oly
Ply
AO0O5248
68633
CJ3
Comer Jack
4
1
Jab Reference (optional)
- - -At RoofTrusses, Fort Pierce; FL 34946, design@al Wss.com
LOADING(psf)
SPACING-
2-0-0
TCLL
20.0
Plate Grip DOL
1.25
TCDL
10.0
Lumber DOL
1.25
BCLL
0.0 '
Rep Stress Inc
YES
BCDL
10.0
Code FBC2014/TPI2007
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 2-11-11 oc
pudins, except end verficals.
BOTCHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. Qb/size)
3 =
0/Mechanical
2 =
228/Mechanical
Max Harz
3 =
-217(LC 1)
2 =
217(LC 1)
Max Uplift
2 =
-89(LC 12)
Max Grav
2 =
228(LC 1)
FORCES. Qb)
Max. Comp./Max. Ten. - All forces 250 Qb) or less except
when shown.
TOPCHORD
1-2=534/266
BOTCHORD
1-3=213/555
NOTES-
1) Wnd: ASCE 7-10; Vuh=160mph (3-second gust)
Vasd=124mph; TCDL=S.Opsf, BCDL=S.Opsf; h=12ft;
Cat. 11; Exp C; End., GCpi=0.18; MWFRS (envelope)
and C-C Extenor(2) zone; cantilever left and right
exposed ; end vertical left exposed;C-C for members
and forces 8 MWFRS for reactions shown;. Lumber
DOL=1.60 plate grip DOL=1.60
2) Plates checked for a plus or minus 0 degree rotation
about its center.
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcument with any other two loads.
Run: 8.020 s Aug 31 2016 Print 8.020 s Aug 31 2016 MiTek Industries, Inca -Man May 1544:30:23 2017 Page 1
ID:vD1jxM_xSyg7jXL6BnpgBAxGFh6 _lot hM?MOwLI?Cj362YAye_iF8326fCeGdl li¢GEn_
2-tt-11
' 2-11-11
19
2.4 =
CS].
DEFL-
in
Qoc)
Udell
Ud
PLATES
GRIP
TC 0.20
Ven(LL)
0.00
6
Wr
90
MT20
244/190
BC 0.30
Ven(TL)
-0.01
3-0
Wr
80
We 0.00
Hoa(TL)
0.00
We
n/a
Matrix -MP
Weight: 12 lb
FT=0
4)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 69 lb uptdt at
joint 2.
7) Gap between inside of top chord bearing and first
diagonal or vertical web shall not exceed 0.500in.
LOAD CASE(S)
Standard
pu+l'bab>p!mnb'N naln,T3(V19'j,'RiYlIDrn4�Y•:E(61:tl(LLY,i1M:lleiirbi luflvypv,u,iitl W �NLrxby Mq�fTdb![,nlr,tl,ll21bv9Ntl, �x kbu,btlumuleblr.`,c,
Lfuwsllb,;tdlatlkblRYbKY 4,1.u4vp41ape.IMII4Pu{nWuglnnrrmeMcYbP,F.sI^Vn^9,MubY144kAdkA41.•a4^fiubit•,n.erlrii ➢,b4 agYatYq umf6
Anthony T. ill. P.E.
el'u1Mlubg4tl#b4nyuJlgdbbs.bt�m5e4Rtl,xtlubWgbtipu,Y4aeib0.b[fWbktlb4,tWdM lq,�ddblWWghxn,d44af Y16gmE4ID4kn.^d[MJdY4nyNatl
SM3
:BOUB3
blubl4Jrev1(uoL.WunuuYJ,Mtl4peaeWN(dn444i44yuulrs,tivX+,APII�f4J111111dN1gi6,nikPudPr�T'I YnbioM,ld„dNutlblmt+•iy.Lm,bglgwul l,wpsbiF, hp
44515L Lade K".
u,r,bbbJ4e�m WMquumyghmptluN.d hhe,bplyubmlbNtlgGye,u lnnywhl�Jq MJy JigYul6nnuvd Ylµ
F0.K %ene, FL 3 946
(,Alto 31541lud 6eum-1mlmpi.ToolaBLpJ. 4pelm.d5isdlugm,uorla,y opnlitudih. aegmea pmmu4tl6ee 41 rM lmvt. hix( Lhq YL Pt.
Job
Truss
Truss Type
Oly Ply
68633
HJ5
Roof Special Girder
2 1 1
A0005249
Job Reference (optional)
--Al Roof Trusses, Fod Pierre, FL 34945, demgn@albuss.4nm Run: 8.020 s
2x4 =
3x4 II
10
1.5x4 II 3x4 _4
LOADING (psi)
SPACING-
243-0
CSI.
DEFL.
in
(loc)
I/defi
L/d
TCLL 20.0
Plate Grip DOL
1.25
TC 0.40
Vert(LL
0.00
5
n/r
90
TCOL 10.0
Lumber DOL
1.25
BC 0.40
Vert
-0.02
4-5
n/r
80
BCLL 0.0 '
Rep Stress Inv
NO
WB 0.20
HOrz(TL)
0.00
n/a
n/a
BCDL 10.0
Code FBC20141TPI2007
Matrix -MP
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 5-10-10 oc
pudins, except end verticals.
BOTCHORD
Rigid ceiling directly applied or 6-0.0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
4 =
O/Mechanical
3 =
964/Mechanical
Max Harz
4 =
-1116(LC 1)
3 =
1116(LC 1)
Max Uplift
3 =
-484(LC 4)
Max Gmv
3 =
964(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. -All forcers 250 (Ib) or less except
when shown.
TOPCHORD
1-2=208/381, 2-3=588/1195,
3-4=257/520
BOTCHORD
1-9=323/219, 5-9=323/219,
5-10=323/219, 4-10=323/219
WEBS
24=889/466, 2-5=195/464
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=S.Opsf; BCDL=5.Opsf; h=12ft;
Cat. II; Exp C; Encl., GCpF0.18; MWFRS (envelope);
cantilever left and right exposed; end vertical left
exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) Plates checked for a plus or minus 0 degree rotation
about its center.
3) This truss has been designed for a 10.0 psf bottom
chord live load nonronwrent with any other live loads.
4)' This truss has been designed for a live load of
20.0psf on the bottom chord in all areas where a
rectangle 3-6.0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 4841b uplift at
joint 3.
7) Gap between inside of top chord bearing and first
diagonal or vertical web shall not exceed 0.500in.
8) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s) 52
lb down and 5016 up at 149. 5216 down and 50 I6
up at 149, and 20016 down and 1181b up at 4-2-8,
and 2001b down and 118 lb up at 4-2-8 on bottom
chord. The desigrdselection of such connection
device(s) is the responsibility of others.
9) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
, Plate Inaease=1.25
Uniform Loads (plf)
Vert 1-3=-60,4-6=-20
Concentrated Loads (lb)
Vert 9=-103(F=52, B=52) 10=399(F=200,
B=200)
R
PLATES GRIP
MT20 244/190
Weight 261b FT = 0%
rur bvb}LLmh�i'NY"JO4M19S:Y{O:iYly'1YIMPV.4:£JIt�n3iUaiTiPllr4al%Ib$P��M1�elMah,�MY Fuir'^q',I"JOIh1Mll,b{IkIMq,9N Ya,ra PNOewvuedvb'.R,�1r
b'tlacYlYn,klbMbb14141,K14e4giv�6pxOr.!palYPa}41Y I[yMov,r,vtl6pinYa/,q"meq,epNxlbbb4tlYsyelm, LpMebll Jr�Al 6Mpa,gM.Wy,�age„38e
A111ony T.Tvmb0lI11,1,
vlwiti fegkiighbnpmNgdbt�qM1C�n,4eGlyeeYbLLjb{q bpctl2bKYLsiMMYbLL+r,LWR{bepriJhl[-0alaikYa,IbSrtH2gbfgbW�.aelY�gJibb„�tlYri
960083
b[ify ipv eiGnb.lO4a YNeb1@vlb P^so¢IPlmtln Wirt,ryfkbtlnPa%YpfylF�ledWnMevdbrwlpHilM1llfmb,gadJfnglb46LntGSp.InahJp4pr YYgMe4ma.W�
44515L Me Blvd.
• Je,1,ilWh [uNgM.pen ybdlaani"l M14 iuplryahx'IYINgk Ge, lNwbpnielbtlmY lO pLLilb a,elEelxlM:
Fort Pimee FL 34946
fgf,gbC inY4l btlLeumlm4mrl. ivala0l, Pi Fpelydgddisleumauv.ImnnpeYraidxAwdemm�pniiwe6e�Fl toofimurkteni.Io-s4ailLN.
3x4 =
1.5x4 II
Plate Offsets (X V)—
[2:0-2-0 0-1-4)
LOADING(pst)
SPACING- 2-0-0
CSI.
DEFL
in
Qoc)
Wei
L/d
PLATES GRIP.
TCLL 20.0
Plate Grip DOL 1.25
TC 0.47
Vert(LL)
0.01
3-6
n/r
90
MT20 2441190
TCDL 10.0
Lumber DOL 1.25
BC 0.58
Vert(TL)
-0.03
3-6
n/r
80
BCLL 0.0 '
Rep Stress Ina YES
WB 0.00
Hom(TL)
0.00
n/a
n/a
BCDL 10.0
Code FBC20141-rP12007
Matrix -MP
Weight; 17 lb FT= 0%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 4-3-0 oc
pudins, except end verticals.
BOTCHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
3 =
0/Mechanical
2 =
331/Mechanical
Max Harz
3 =
-018(1-C 1)
2 =
318(LC 1)
Max Uplift
2 =
-123(LC 8)
Max Grev
2 =
331(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (Ib) or less except
when shown.
TOP CHORD
1-2=-810/395
BOTCHORD
1-3=318/833
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vesd=124mph; TCDL=5.Opsf; BCDL=5.Opsf; h=12ft;
Cat. II; Exp C; End., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed;C-C for members
and forces 8 MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) Plates checked for a plus or minus 0 degree rotation
about its center.
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
4)' This truss has been designed for a live load of
20.0psf on the bottom chord in all areas where a
rectangle 3-&0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss
to hearing plate capable of withstanding 123 lb uplift at
joint 2.
7) Gap between inside of top chord bearing and first
diagonal or vertical web shall not exceed 0.500m.
LOAD CASE(S)
Standard
hvgM bw}{mzab'1J[v$Fi{6Y3'dANP�R' {ORTEnPtlY(I6ffjU4uiI1P.JiSa i.rykgpmb�d:d Mnw9nl rsbvl0nhipSldbIM111ub4124barYkY PhaWmWadin,iP
Wrdoobtl•'wdhr6bblM pMh6 Wti1h1®P �Fa#rMn{dvtl YnP� ^i:WObPi'!W+°4 Mm2'ifbbkPYbuAI Mai 4'a:w,aY1R{M1hepaoMmF:hl rt'-�u.IhT.
hlL anY T. i7[. P.E.
dyih`I b bYalkaznpWfgtlb4 Sl.n'M.vJys bblf'gbp."bsentlb Cb4d#Ytlb1y YWILL Bagntld#IC:da1M dblm.Wi:im9y.Yerpin30a'.wtlhayJlbbieyedYrd
oNW3
�3
'
b ldtyB.yetllIXW.11ehWM blpwlbpnnwir¢MdbWBq Lap:6ePWah:TN,pikhtMlMdT3 k dbpatlpbillFldnh�ynNJh�dlmA#imp#ywlw#Ja[q�mdYUXd¢mn,Wu
�
d45
Judeifidp uftlgal}:hWgpGptr,Nti iT M_p Lpn fil6di:hlk� 1 Wu6pnJ b+tf-; IDW:+6Mh neiMe151
FOR PI¢Ice, FL 3'1916
Pmr..RM
� rrryrR-I Q; JrUAlbdL rr AvR YI.Ie�1erl.lE repdafiwtll4.dvimen nIW«npMe^ad.Mvvl@enrevpebsroatrea}Iredrmsn lalevll lemE llL/1.