HomeMy WebLinkAboutPRODUCT APPROVALProfessio 7 nal Renj ' I'at - ion
�Ll� : A;
BCS Home Log In 1 USer RegiStratiOn . Hot Topics Submit Surcharge Stats & Fach; ftbllcati.. FBC Staff BCJS Site Map U.ks Searclh
a QW OH! P'Mduct'Approval SCANNEL)
" 'u,
db 11 R: u ic Umr
pr By
product Approyal Menu > product or Aonflcaflo� Search > Applicotio, i,j > Applicaticon Detail St. Lucie Colint,
FL # FL7804-R9
Application Type Revision
Code Version 2014
Application Status Approved "T"ILE V�,
Comments
Archived
Product Manufacturer Entegra Roof Tile, Inc.
Address/Phone/Emall 1289 NE 9th Avenue
Okeechobee, FL 34972
(863) 467-0042 Ext 1228
tJohnson@rooftile.com
Authorized Signature
Terry Johnson
tjohnson@rooftile.com
THESE PLANS AND ALL PROPOSSD WOM
Technical Representative
Jim Deyarmond
ARE SMUT TO ANY COPIRECTIONS
Address/Phone/Emall
1289 NE 9th Avenue
REQUIRM BY FIELD INSPECTORS THAT
Okeechobee, FL 34972
MAY BE NECENANY 114 ORM TO
(863) 467-0042
JDeyarmond@rooftile.com CrAAPLY WrM ALL APPLICABLE CODES.
Quality Assurance Representative
Terry Johnson
Address/Phone/Email
819 South Federal Hwy Suite 300
Stuart, FL 34994
(800) 586-7663
tjohnson@rooftile.com
Category Roofing
Subcategory Roofing Tiles
Compliance Method Evaluation Report from a Florida Registered Architect or a Ucensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida Ucense PE-59166
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 11/04/2017
Validated By John W. Knezevich, PE
� Validation Checklist - Hardcopy Received
Certificate of Independence EL7804 R9 COI �Qjo Q1 COI Nieminen.pdf
Referenced Standard and Year (of Standard) Standard Yea
ASTM C1492 2003
FRSA/TRI April 2012 2012
SSTD 11 1997
TAS 100 1995
TAS 101 1995
TAS 102 1995
TAS 102(A) 1995
TAS 112
Equivalence of Product St-- cls
Certified By
1995
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
Date Validated
Date Pending FEC Approval
Date Approved
Summary of Products
I
Pul
FL#
game
Description
7804.1
Entegra Concrete Roof Tiles (HVHZ
�
Concrete Roof Tlle
jurisdictions)
Limits of Use
Installation Instructions
Approved for use In IHVHZ- Yes
FL7804 R9 H 2016 04 FINAL ER ENTEGRA FL7804-
R9 HVHZ.od
Approved fbr use outside HVHZ: No
Impact Resistant: N/A
Verified By: Robert Nleminen PE-59166
Design Pressure-. N/A
Created by Independent Third Party: Yes
Other: Refer to ER Section 5 for Umits of Use. Refer to ER
Evaluation Reports
Section 6 for Installation.
FL7804 R9 AE 2016 04 FINAL ER ENTEGRA FL7804-
R9 HVHZ.od
Created by Independent Third Party: Yes
7804.2
of Tiles (non-
Concrete Roof Tile
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FI-780 R9 if 2016 04 FTNAI� ER ENTEGRA FL7804-
R9 NON-HVHZ.pd
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nleminen PE-59166
Design Pressure: N/A
Other: Refer to ER Section 5 for Unnits of Use. Refer to ER
Created by Independent Third Party: Yes
Evaluation Reports
Section 6 for Installation.
FL7804 R9 Ar 2016 04 FINAL ER ENTEGRA FL7804-
R9 NON-HVHZ.od
Created by Independent Third Party: Yes
ED EA
Contort Us :: 2601 8I.Ir Ston. Road. Tallahassee FL 32399 Phone, 850-487-1824
ne State of Florida Is an AVEM employer. Cownght 2007-2013 Stuta of Florida. :: privacy SnIemen :: Ames,abliltv Statamen :: Refund Statemen
Under Florida law, email addresses am public mcoms. If you do not want your e-mail address released In nes;x,,,se to a public -records request, do not send electmm:
mail. to UnIs entry. Inatead, conitact the office by phone or by maditional mail. If you have any quasUons, please contact 850.487.1395. *Pursuant to Section
455.275(l), Florida statutes, offective October 1, 2012, licensees licensed under Chapter 455, F.S. most provide the Department with an email address If they have
one. ne emalls provided may be used for official communication with the licensee. However email addresses am public record. If you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the public To determine if you am a liceresee under Chapter
455, F.S., please dIcic hem
product Approval Accepts:
W M3X HE M
Credit Card
Safe
EXTERIOR RESEARCH & DESIGN, I.I.C.
Certiftate of Authorization #9.503
QTRINITY ERD 353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
PHONE: (203) 262-9245
EVALtATION REPORT FAX: (203) 262-9243
Entegra Roof Tile, LLC Evaluation Report E39310.11.11-2-R4
ENTEGRA 1289 NE 9 th Avenue
R 0 D F T I L E FL7804-R9
Okeechobee, FL 34972 Date of issuance: 11/02/2011
SCOPE: Revision 4: 04/18/2016
This Eviluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
constrErtion materials in the State of Florida. The documentation submitted has been reviewed by Robert Nlemlnen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
product described herein have been evaluated for compliance with the 51h Edition (2014) Florida Building Code (non-
HVHZ) sections noted herein.
DESCRIPTION: Entegra Concrete Roof riles (non-kVHZ Jurisdictions)
LABEUNC: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report bythe named client constitutes agreemeritto notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete
review ofthis Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity]ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTIO\I: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Offlcial.
This Evaluation Report consists of pages I through 6.
Prepared by:
Robert JI.M. Nierninen, P.E.
Florida Regisnationr10- 59166, Florida DC4 ANE1983
Me fe-froll. �.el a,00do, Wu =!,ordod by Robed Nfiernfinen,
P-E On 04/18/2016. This doe, n.t�om,.e d .1ev.nk.11yM9n.d
CERTIFICA71ON OF INDEPENDENCE: . . ...... m ProdudAPP�l AdMinls�t.r.od W 0, da.ed dera
I. Trinity] ERD does not have, nor does it intend to acquire or will it acquire, a financial interest In any company manufacturing or
distributing products it evaluate,.
2. Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E, does not have nor will acquire, a financial interest In any company manufacturing or distributing products for
which the evaluation reports are being Issued.
4. Robert Nierninen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither TrinitVl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record fo r any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY ERD
4. PRODucr DESCRIPTION:
4.1 BERMuDA FLAT, PLANTATION FLAT and HORtzoN FLAT are ASTM C1492, Type III (low -profile) concrete roof tiles.
13"
16'
16'
Bermuda Flat
Plantation Flat
M
Horizon Flat
)f Evaluation Report E39310.11.11-Z-R4
MLE 4
Bderlor Research and Design, I.I.C. F CC)""
r-,UfWe of Authark.Un #9S03 Ed FL7804-R9
Revision 4:04/18/2016
Page 3 of 6
TRINITY ERD
4.3 GALENA SPANISH "S" and REGAL are ASTM C1492, Type I (high -profile) concrete roof tiles.
Regal
S. UivimiciNs:
5.1 This is a building code evaluation. Neither Trinity] ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire classification is not part of this evaluation; refer to FBC Section 1505, Exception 2 or current Approved
Roofing Materials Directory forfire rating of this product.
5.4 Underlayment shall be that approved by Entegra Roof Tile, which holds Florida Local or Statewide Product
Approval for use with tile roofing systems. The underlayment Product Approval shall specify allowable
method(s) of tile installation (mechanical attachment, mortar -set and/or adhesive -set) for use with the
specific underlayment. For mortar -set or adhesive -set tile roofing applications, the underlayment Product
Approval shall specify attachment methods for the underlayment system to resist wind uplift design loads in
accordance with Table 1A of FRSA/TRl April 2012 (04-12).
5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and F.A.C. Rule 61G20-3.
Exterior Research and Design, I.I.C.
Cerilfcate of AWhorlzatlon MEG
Evaluation Report E39310.11.11-2-R4
FL78O4-R9
Revision 4-.04/18/2016
Page 5 of 5
Prolessional R,-
PAZ M
acts Home Log In I UserikeglAnation Hot Topics SubmIt Surcharge Stats & Faeta . ftbil.tions � FBC Staff I acts Site Map Un� ! Seamh
ProductApproval
db USM �bllc Uwr sGANNED
a BY
Pmduct Approval Man > Product or Amligall.. S.an�h > Appligation U > Apprication Detall St. Lucip countv
FL # FL5259-R25
Application Type Revision
Code Version 2014
Application Status Pending FBC Approval
Comments A7—m
Archived Y
FILE Go"OP"
Product Manufacturer POLYGLASS USA
Address/Phone/Emall 150 Lyon Drive
Fernley, NV 89408
(570) 384-1230 Ext 242
jakins@poiyglass.com
Authorized Signature James Akins
lakinsOpolyglass.com
Technical Representative Steve Wadding
Address/Phone/Email 150 Lyon Drive
Fernley, NV 98408
(602) 363-7139
st,evew@polyglass.com
Quality Assurance Representative James Akins
Address/Phone/Email 555 Oakridge Road
Humboldt Industrial Pkwy
Hazleton, PA 18201
(800) 894-4563
jakins@polyglass.com
Category Roofing
Subcategory Underlayments;
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida Ucense PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 04/24/2018
Validated By John W. Knezevich, PE
� Validation Checklist - Hardcopy Received
Certificate of Independence FL5259 R25 COI ZQ16
01 COI Nieminen,pdf
Referenced Standard and Year (of Standard) Standard
Year
ASTM D1970
2009
ASTM D226
2006
ASTM D6164
200S
ASTM D6222
2008
ASTM G154
2006
ASTM G155
2005
ri., "'� 2004
FRSAM April 2012 2012
TAB 103 199S
UL 1897 2004
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Summary of Products
Method I Option D
10/17/2016
10/18/2016
10/19/2016
FL At
Model, Number or Name
Description
5259.1
Polyglass Roof
Roofing underlayments
Underlayments
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
Approved for use outside HVHZ: Yes
FL5259 R25 11 2016 IQ FINAI, �R POIYGI ASS UNDERLAYMENTS FL5259-
R25.pd
Impact Resistant: N/A
Design Pressure; +N/A/-622.5
Other. 1.) The design pressure in this
application relates to one particular
underlayment system (over concrete deck) for
Verified By: Robert Nieminen PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
FL5259 R25 AE 2015 10 FINAL ER POLYGLASS UNDERLAYMENTS FL5259-
R25.Dd
use under foam -on tile systems (where the
underlayment forms part of the load -path).
Created by Independent Third Party: Yes
Refer to ER Section 5.6.4 for other systems,
other deck types and associated maximum
design pressures. 2.) Refer to ER Section 5 for
other limits of use.
EC] ED
Contact Us :: 2WI Blair Stone need, `Tbllaha��ec Fl- 3ZI99 Phone, 85�487-1824
ne State of Flodda IS an WEE0 employer. Copvdcht 207-2013 State of Florida. :: privacy statement :: Acocssibility Statemen :; Refund Statelone
Under Florida law, email addresses am public records. if you do not want your e-mail address released In ms;,cmm to a public-recends request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traciltional mail. If you have any questions, please contact 850.,187.1395. *Puisuart to section
45S.275(l), Florida Statutes, effective Octolmr 1, 2012, licensees liceemed under Chapter 4S5, F.S. must provide the Department with an email address if they have
one. The ernalls provided may be used for official communication with the licemee. However email addresses am public mci If you do not wish to supply a
personal address, please provide the Deloartment with an email address which an be made available to the Publ1Q To determine if You am a licensee under Chapter
455, F.S., please dicIr
Product Approval Accepts:
Credit Card
Safe
FILE Cum Y
EXTERIL v',".ESEARCH & DESIGN, I.I.C.
Certificate of Authorization #9503
I RINI-rY ERD 353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
PHONE: (203) 262-9245
REPORT - FAX: (203) 262-9243
lolyglass USA, Inc. Evaluation Report P12060.02.09-RZ1
L50 Lyon Drive FL5259-R25
:ernley, NV 98408 Date of Issuance: 02/24/2009
;COPE: Revision 21:10/17/2016
-his Evaluation Report is issued under Rule 6IG20-3 and the applicable rules and regulations governing the use of
:onstruction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.
or use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
lescribed herein have been evaluated for compliance with the 51h Edition (2014) Florida Building Code sections noted
ierein.
)ESCRIPTION: Polyglass Roof UnderlayMents
ABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
:ONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Itiality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
valuation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
aferenced Quality Assurance documentation changes. Trinityl ERD requires a complete review of this Evaluation Report
elative to updated Code requirements with each Code Cycle.
LDVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
dvertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
JsPEcTloN: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
istributors and shall be available for inspection at the job site at the request of the Building Official.
his Evaluation Report consists of pages 1 through 13.
repared by:
Dbert J.M. Nieminen, P.E.
odda Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert Nieminen,
P.E. on 10/17/2016. This does not serve as an electronically
signed document. Signed, sealed hardcoples have been
transmitted to the Product Approval Administrator and to the
named client
'RTIFICATION OF INDEPENDENCE:
Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturin g or
distributing products it evaluates.
Trinity I ER D is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
Robert Nlemlnen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
Robert Nlemlnen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
This is a building code evaluation. Neither Trinityl ERD nor Robert Nleminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
- 4.1 14JIM-010MIN 01,O)NO,
TRINI-rY ERD
ROOFING COMPONENT EvAwATiON:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is
subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind Uplift
FIVI 4474
2004
1504.3.1
Wind Uplift
UL 1897
2004
1504.6
Accelerated Weathering
ASTM G154
2006
1504.6
Accelerated Weathering
ASTM GISS
2005
1507.2.3,1507.3.3,1507.5.3,1507.7.3,
Physical Properties
ASTM D226
2006
1507.8.3, 1507.9.3
1507.2.4, 1507.2.9.2, 1507.5.3, 1507.7.3
Physical Properties
ASTM D1970
2009
1507.11.2
Physical Properties
ASTM D6164
2005
1507.11.2
Physical Properties
ASTM D6222
2008
1507.3.3
Installation Practice
FRSA/TRI April 2012
2012
1523.6.5.2.1
Physical Properties
TAS103
1995
3. REFERENCES:
fLnft
Examination
Reference
Date
FM Approvals (TST 1867)
Wind Uplift
3004091
01/1212000
FRI (TST 5878)
Physical Properties
PRiO1111
04/08/2002
PRI (TST 5878)
Physical Properties
PUSA-005-02-01
01/31/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-01
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-02
12/2312002
PRI (TST 5878�
Physical Properties
PUSA-013-02-03
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-019-02-01
07/14/2003
PRI (TST 5878)
Physical Properties
PUSA-02"2-01
07/13/2005
PRI (TST 5878)
Physical Properties
PUSA-033-02-01
01/12/2006
PRI (TST5878)
Physical Properties
PUSA-035-02-01
09/29/2006
PRI (TST 5878)
Physical Properties
PUSA-055-02-02
12/10/2007
PRI (TSTS878)
Physical Properties
PUSA-061-02-02
01/28/2008
PRI (TST 5878)
Physical Properties
PUSA-076-02-01
02/22/2008
PRI (TST 5878)
Physical Properties
PUSA-083-02-01
04/14/2008
FRI (TST 5878)
Physical Properties
PUSA-088-02-01
07/29/2009
MTI (TST 2508)
Physical Properties
JX20H7A
04/01/2008
MTi (TST 2509)
Physical Properties
RX14ESA
01/29/2009
ERD (TST 6049)
Physical Properties
11752.09.99-1
02/08/2000
ERD (TST 6049)
Wind Uplift
11757.08.01-1
08113/2001
ERD (TST 6049)
Wind Uplift
11776.06.02
01/16/2003
ERD (TST 6049)
Physical Properties
02200.07.03
07/14/2003
ERD (TST 6049)
Wind Uplift
P1740.01.07
01/04/2007
ERD (TST 6049)
Physical Properties
P5110.04.07-1
04/11/2007
ERD (TST 6049)
Wind Uplift
P9260.03.08
03/21/2008
ERD (TST 6049)
Physical Properties
P134SO.09.09
08/13/2009
ERD (TST 6049)
Wind Uplift
P30540.11.09-RI
11/30/2009
ERD (TST 6049)
Physical Properties
P11030.11.09-1
11/30/2009
ERD (TST 6049)
Wind Uplift
P11030.11.09-2
11130/2009
ERD (TST 6049)
Physical Properties
P11030.11.09-3
11/3012009
ERD (Tsr 6049)
Physical Properties
P33360.06.10
05/25/2010
Exterior Research and Design, LLr—
Certificate OfAuthorization #9503
FBC NON-HVHZ EVALUATION
4M,
.--FAY
Evaluation Report P12060.02.09-1121
FL5259-R2S
Revision 21:10/17/2016
Page 2 of 13
4.
TRINITY ERD
Entity Examination Reference Date
ERD (TST 6049) Physical Properties P33370.03.11 03/02/2011
ERD (TST 6049) Physical Properties P33370.04.11 04/26/2011
ERD (TST 6049) Physical Properties P37300.10.11 10/19/2011
ERD (TST 6049) Physical Properties P40390.08.12-1 08/06/2012
ERD (TST 6049) Physical Properties P40390.08.12-2 08/07/2012
ERD (TST 6049) Physical Properties C41420.09.12-3 09/11/2012
ERD (TST 6049) Wind Uplift P39680.03.13 03/04/2013
ERD (TST 6049) Physical Properties P45370.04.13 04/26/2013
ERD (TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013
ERD (TST 6049) Wind Uplift 11757.04.01-1-RI 04/30/2013
ERD (TSr 6049) WindUplift P41630.08.13 08/06/2013
ERD (TST 6049) WindUplift P11751.05.03-111 11/26/2013
ERD (TST 6049) WindUplift P11781.11.03-RI 11/26/2013
ERD (TST 6049) Physical Properties P45270.05.14 05/12/2014
ERD (TST 6049) Physical Properties 6020.07.14-1 09/08/2014
ERD (TST 6049) Physical Properties 6020.09.14-2 09/08/2014
ERD (TST 6049) Physical Properties 6020.09.14-3 09/08/2014
ERD (TST 6049) Physical Properties 6020.09.14-4 09/08/2014
ERD (TST 6049) Physical Properties 6020.09.14-5 09/08/2014
ERD (TST 6049) Physical Properties 6020.09.14-6 09/08/2014
ERD (TST 6049) Physical Properties P46520.10.14 10/03/2014
ERD (TST 6049) Physical Properties P44360.10.14 10/07/2014
ERD (TST 6049) Physical Properties P43290.10.14 10/17/2014
ERD (TST 6049) Physical Properties PLYG-SC7550.03.15 03/24/2015
ERD (TST 6049) Physical Properties P40390.04.15 04/03/2015
ERD (TST 6049) Physical Properties PLYG-SC8080.05.15-1 05/20/2015
ERD (TST G049) Wind Uplift PLYG-SCS905.05.16-1 05/17/2016
ERD (TST 6049) Physical Properties PLYG-SCS080.07.16 07/16/2016
ERD (TST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016
ICC-ES (EVL 2396) IBC Compliance ESR-1697 11/01/2014
Miami -Dade (CER 1592) HVHZ Compliance NOA 14-0717.08 01/22/2015
Polyglass USA Manufacturing Affidavit Products Current 02/18/2009
Polyglass USA P/1-Afficlavit Mule -Hide Cross Ltg 03/01/2008
Polyglass USA Materials Afficlavit Polystick SA Compound 08/18/2011
UL, U.C. (QUA9625) Quality Control Service Confirmation Exp.04/24/2018
PRODUCT DESCRIPTION:
4.1 Mechanically Fastened Underlayments:
4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet.
4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet.
4.1.3 Polyglass GZ Base is a fiberglass -reinforced, asphaltic base sheet.
4.1.4 Polyglass APIP Base is a fiberglass -reinforced, APP modified bitumen base sheet.
4.2 Self -Adhering Underlayments:
4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced
with polyolefinic film surface; meets ASTIVI D1970 and TAS 103.
4.2.2 Polystick MITS PLUS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced,
surfaced with poly -film surface; meets TAS 103.
4.2.3 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an
aggregate surface; meets ASTM D1970.
Exterior Research and Design, ULC. Evaluation Report P12060.02.09-R21
Certificate of Authorization #9503 FBC NON.HVHZ EVALUATION FL5259-RZS
Revision 21:10/17/2016
FRILE COPY Page 3 of 13
�JTRINJ_FY ERD
4.2.4
PolystickTU Plus is a nominal 80-milthick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a
polyester fabric surface; meets ASTM D1970 and TAS 103.
4.2.5
Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester
reinforced, with a granular surface; meets ASTIVI D1970 and TAS 103.
T" 4.2.6
Polystick TU'Max is a nominal 6G-mil thick rubberized asphalt waterproofing membrane With a 190 g/M2 polyester
fabric surface; meets ASTM D1970 and TAS 103.
4.2.7
Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet [FR) are polyester
reinforced, APP modified bitumen cap sheets; meet ASTM D6222.
4.2.8
Polystick Dual ProYs' is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTM D1970.
4.2.9
Polystick Tile Pro'"s is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTM D1970 and TAS 103.
4.2.10
Polystick MU-X is a nominal 54-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polypropylene film surface; meets AC188 and physical requirements of ASTM D1970.
4.3
Mechanically Fastened and/or Bonded Underlayments*
4.3.1
Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced, SIBS modified bitumen cap sheets; meet ASTM D6164.
4.3.2
Polyflex G and Polyflex 6 FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTIVI D6222.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity] ERD nor Robert Nieminen, P.E. are, in anyway, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evalbation Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. if not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers:
TABLE 1: 11130FCOM OPTIONS
Underlayment
Asphalt Shingles
Nafl-OnTile
I'min-On rile
Metal
Wood Shakes &
Slate
Shingles
Yes
Yes
Elastobase
Yes
(�eahakb,2-ply
(base sheetin 2-ply
Yes
Yes
Yes
�-nnl
"tam)
Yes
Yes
Elastobase P
Yes
(bo,.sheetin2,1,
(basaaheethnZ-ply
Yes
Yes
Yes
'Ww.)
,be.)
Yes
Yes
Polyglass G2 Base
No
(basesheetin 2-ply
Ibaseshaetfn2-ply
No
No
No
awt.m)
systa.)
Yes
Yes
Polyglass APP Base
No
(basesheetha:t-phy
(base sheet In 2-ply
No
No
No
swtem)
Polystick NITS
Yes
Yes
No
Yes
Yes
Yes
Polystick MTS PLUS
Yes
Yes
No
Yes
Yes
Yes
Polystick IR-Xe
Yes
No
No
No
Yes
Yes
PDlystick TU P
Yes
Yes
Yes
No
Yes
Yes
SeeS.S.1
PolystickTU Plus
Yes
i
Yes
Yes
Yes
Yes
Yes
I
See S.S.1 I
Exterior Research and Design, LLC Evaluation Report P12060.02.09-R21
Certificate ofAutharization #9503 FBC NON-HVHZ EVALUATION FL5259-RZ5
Revision 21:10/17/2016
FILE COPY Page 4 of 13
i'TPJNITY ERD
TABLE I: ROOF COM OPTIONS
Underlayment
Asphalt Shingles
Nall -On Tile
Foarn-On Tile
metal
I
Wood Shakes &
Slate
ee �,
Shingles
Polystick TU Max
No
Yes
Yes
Yes
No
No
� 5.5.1
Polystick Dual Pro
Yes
Yes
No
Yes
Yes
Yes
Polystick rile Pro
Yes
Yes
Yes
Yes
Yes
Yes
See 5.5.1
Polystick MU-X
Yes
No
No
Yes
Yes
Yes
Elastollex S6 G
Yes
Yes
Yes
No
Yes
Yes
See S.S.1
Elastoflex S6 G FR
Yes
Yes
No
No
Yes
Yes
polyflex 6
Yes
Yes
Yes
No
Yes
Yes
See S.S.1
Polyflex G FR
Yes
Yes
No
No
Yes
Yes
Polyflex SAP or SAP FR
Yes
Yes
Yes
No
Yes
Yes
See S.S.1
Mule -Hide SA-APP Cap Sheet
Yes
or SA-APP Cap Sheet (FR)
Yes
Yes
SeeS.S.1
No
Yes
Yes
5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives unless tensile adhesion / long term aging
data from an accredited testing laboratory is provided.
3M'm 2-Component Roof Tile Adhesive AH-160 (FL6332): Polystick TU P, Polystick TU Plus, Polystick TU Max,
Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP
Cap Sheet (FR) or Tile Pro.
3Mm Foam Roof Tile Adhesive RTA-1 (FL6276): Polystick TU P, Polystick TU Plus, Polystick TU Max, Elastoflex S6
G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
or Tile Pro
Convenience Products' Touch 'n Seal StormElond Roof Tile Adhesive (FL14506): Polystick TU Plus, Polystick TU
Max.
Dow TileBond (FL717): Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro.
Polyglass PolyLok of Tile Adhesive (FL17855): Polystick TU Plus or Polystick TU Max.
O'yg'ass PO'VLO"
5.6 Alin bleSubstrat I
S.6.1 Direct- nd,to it:
Polystick 11 ariations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet
(FR) self -a ered to:
> New ntr ted plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing
0 p I
,
ood; N or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
S rl 1
5 XthernYello snoel'; ASTM D41 primed structural concrete; Huber Engineered Woods ZIP System" Panels
Sig stal
designed and instal d to meet wind loads for project),
Note: Polyglass.does not.require priming of new or existing plywood or 05B sheathing. New or existing plywood or
OSEI sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes.
Elastoflex S6 G or S6 G Fil in hot asphalt to:
> ASTM 041 primed structural concrete.
Polyflex G or G FIR torch -applied to:
> ASTM D41 primed structural concrete.
Exterior Research and Design, I.I.C.
certificate of Authorization #9503
F8C NON-HVHZ EVAWATION
Evaluation Report P12060.02.09-R21
FL5259-RZS
Revision 21: 10/17/2016
Page 5 of 13
TRINITY ERD
5.6.2 Bond -to -insulation:
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered
to:
> ASTM C1289, Type 11, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck
DuraGuard; Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board.
ElastoflexS6 G or S6 G FR in hot asphaitto:
> Dens Deck Prime or SECU ROCK Gypsum -Fiber Roof Board.
Polyflex G or G FR torch -applied to:
> ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile
systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of
the insulation/underlayment system in accordance with FBC Section 1504.3.1.
5.6.3 Bond to Mechanically Attached Base Layer:
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or
Tile Pro self -adhered to:
> ASTM D226, Type I or 11 felt; Elastobase; Elastobase P or Mule -Hide Nail Base.
Elastoflex 56 G or S6 G FR in hot asphalt to:
> ASTM D226, Type I or 11 felt; Elastobase; Elastobase P, Mule -Hide Nail Base or PolVglass G2 Base.
Polyflex G or G FR torch -applied to:
> Elastobase, Elastobase P, Mule -Hide Nail Base, Polyglass G2 Base or Polyglass APP Base.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
6odified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in
accordance with FBC Section 1504.3.1.
5.6.4 Wind Resistance for Underlayment Systems in Foam -On 'rile Applications: FRSA/TRl April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment
forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRJ April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure
divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRl April 2012 (04-
12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads.
5.6.4.1 Maximum Design Pressure = -90 ps :
Deck; Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, PolystickTU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet [FR), self -adhered.
5.6-4.2 Maximum Design Pressure = -97.5 psf.*
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: PolystickTU P, PolystickTU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
1W ring shank nails through 32 ga., 1-5/9" diameter tin caps spaced 12-inch o.c.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R21
Certificate of Authorization #9503 FBC NON-HVHZ EVAUUATION FL5259-R25
Revision 21:10/17/2016
Page 6 of 13
*A
AA
TRINITY ERD
5.6.4.3 Maximum Design Pressure -105 psf-.
Deck: Min. 15/32-inch plywood to meet project requirementsto satisfaction of Authority Having Jurisdiction.
Primer: WB-3000
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: PolystickTU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP Fil, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
W ring shank nails through 32 ga., 1-5/9" diameter tin ups spaced 12-inch o.c.
5.6.4.4 Maximum Design Pressure = -135 p
Deck; Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) PG100 or ASTM D41
Joints: Min. 4-Inch wide strips of Elastoflex SA-V over all plywood joints.
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, PolystickTU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
5.6.4.5 Maximum Design Pressure = -325 ps
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having.luriscliction.
Primer! PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment; Polystick TU P, PolystickTU Plus, Polystick TU Max, Tile Pro, PoWex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap
Sheet and Mule�Hide SA-APP Cap Sheet (FR), self -adhered,
5.6-4.6 Maximum Design Pressure = -622.5 ps :
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Elastoflex S6 G, applied In fu 11 mo pping of hot asphalt o r Polyflex G, torch -a pplied.
5.6.4.7 Maximum Design Pressure = -30.0 psf*:
Deck: Min. 15/32-Inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round ' meta[ cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: PolystickTU P, PolystickTU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
5.6.4.8 Maximum Design Pressure = -37.5 psf*:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: PolystickTU P, PolystickTU Plus, PolystickTU Max, Polyflex SAP, Polyfl"SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
5.6A.9 Maximum Design Pressure = -37.5 psf*:
Deck; Min. 19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) or two (2) layers ASTM D226, Type 11 felt
Fasteners: 11 ga. x 1.25-Inch long x 1-inch head diameter round metal cap nails
Spacing: G-Inch o.c. at the 3-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
y
. iv M
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R21
Certifimte ofAuthorization #9503 FBC NON-HVHZ EVALUATION FL5259-RZS
Revision 21: 10/17/2016
Page 7 of 13
TRINITY ERD
5.6-4-10 Maximum Design Pre sure -4S psf*:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) layer ASTIM D226, Type 11 felt
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diametertincaps
Spacing: 4-inch o.c. at the 2-Inch wide side laps and 4-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex S6 G, applied in full mopping of hot asphalt
5.6-4-11 Maximum Design Pressure = -45 psf*:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Two (2) layers ASTM D226, Type 11 felt
Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 9-inch o.c. at the 2-Inch wide side laps and 9-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex S6 G, applied in full mopping of hot asphalt
S.6.4.12 Maximum Design Pressure = -45 ps
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot�asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MA)O(Cap Fasteners
Spacing: 9-inch o.c. at the 2-inch wide side laps and 18-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
5.6.4.13 Maximum Design Pressure = -52.5 ps :
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
5.6.4.14 Maximum Design Pressure= -52.5 psf.
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastabase or Mule -Hide Nall Base (poly -film top surface)
Fasteners; Simplex Original Cap Nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, PolystickTU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FRI, self -adhered.
5.6.4.15 Maximum Design Pressure = -52.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: 6-Inch o.c. at the 3-inch wide side laps and 6-Inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: ElastoflexS6 G, applied in full mopping of hot asphalt or PolVflex G, torch -applied.
5.6.4.16 Maximum Design Pressure = -60 ps
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: 11 ga. x 1.25-Inch long x 3/8-Inch head diameter annular ring shank roofing nails at 1-5/8-Inch diameter tin caps
Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex SG G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
FILC UUPY
Exterior Research and Design, ULC.
Certifimte of Authorization #9503
rsC NON-HVHZ EVALUATION
Evaluation Report P12060.02.09-R21
FL5259-R25
Revision 21: 10/17/2016
Page 8 of 13
TRINITY ERD
5.6.4.17 Maximum Design Pressure -60 a
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-Inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
5.6.4.19 Maximum Design Pressure = -67.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment)
Fasteners: 12 ga. x 1.25-Inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-518-Inch diameter tin caps
Spacing: 8-Inch o.c. at the 4-inch wide side laps and 8-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment; Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
5.6.4.19 Maximum Design Pressure = -75 psf-
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-Inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 113-Inch o.c. at the 4-inch wide side laps and 10-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
5.6.4.20 Maximum Design Pressure = -90 psh
DecL- Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MW Cap Fasteners
Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, a ppI led in fu I I mopping of hot asphalt or Polyflex G, to rch-a ppl led.
5.6.4.21 Maximum Design Pressure= -90 ps :
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roolgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6-inch o.c. at the 4-Inch wide side laps and 6-Inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex SG G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
5.6.4.22 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast#14 HD with Trufast 3" Metal Insulation Plates
Spacing: G-Inch o.c. at the 4-inch wide side laps and 6-Inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
5.6.4.23 Maximum Design Pressure = -90 psf.
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underloyment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-Inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
Exterior Research and Design, U.C. Evaluation Report P12060.02.09-R21
Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION FL5259-R25
Revision 21: 10/17/2016
Page 9 of 13
TRINrrY ERD
5.6-4-24 Maximum Design Pressure= -97.5 p
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c. at the 4-inch wide side laps and 4Anch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: PolystickTU P, Polystick TU Plus, Polystick TU Max, Po"ex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
5.6-4-25 Maximum Design Pressure = -105 ps
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex SIS G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
5.6.4.26 Maximum Design Pressure = -112.5 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule,Hide Nail Base (polV-film top surface)
Fasteners: 11 ga. X 1.25-inch x 3/8-Inch head diameter annular ring shank roofing nails at 1-5/8-inch diametertincaps
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Primer. PG100orASTM D41 primerat all tin -caps
Base Ply: Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
5.6-4-27 Maximum Design Pressure = .220 0
DecL, Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roolgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing; 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows.
Undedayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
5.6A.28 Maximum Design Pressure = -120 p
Deck; Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet; Elastobase (sanded top surface)
Fasteners: Trufast #12 OP orTrufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at rive (5) equally spaced staggered center rows.
Underlayment: ElastoflexS6 G, applied in full mopping of hot asphalt.
5.6-4-29 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on tile systems carry a Maximum
Design Pressure of -45 psf.
5.6-4-30 For mechanically attached base sheet, the maximum design pressure for the selected assembly shall meet or exceed
the Zone 1 design pressure determined in accordance with FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC
1609. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the
elevated pressure criteria. Commonly used methods are RAS 117, FM LPDS 1-29 and ANSI/SPRI WD1. Assemblies
marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FIVI Loss Prevention Data Sheet 1-29
(January 2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days
after installation.
Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after installation.
Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Dual Pro or Tile Pro shall not be left exposed for longer than 180-
days after installation.
Exterior Research and Design, ULC. Evaluation Report P12060.02.09-R21
Certificate ofAuthorizaton #9503 FBC NON-HVHZ EVALUATION FL5259-RZ5
Revision 21: 10/17/2016
Page 10 of 13
' J"�.p
0 in,
TRINITY ERD
Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30
days.
Elastoflex S6 G or S6 G FR or Polyflex G or G FR does not have an exposure limitation, unless the prepared roof
covering is to be adhesive -set tile (Elastoflex 56 G or Polyflex G only), in which case the maximum exposure is 180
days.
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be Installed in accordance with Polyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Elastobase. Elastobase P or Mule -Hide Nail Base:
6.3.1 Shall be installed in compliance with the codified requirements for ASTM D226, Type 11 underlayment in FEC Sections
1507 for the type of prepared roof covering to be installed.
6.3.2 Non-T-ile Applications:
Reference is made to the current edition of the NRCA Steep -slope Roofing Manual and ARMA recommendations for
installing shingle underlayments and flashings
Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP or SAP FR,
Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or -Tile Pro, self -adhered, Elastoflex S6 G or S6 G FR in
hot asphalt or Polyflex G or G FR, torch applied.
6.3.3 Tile Applications:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table I herein, using the instructions noted
above as a guideline.
6.4 Polystick MTS, MTS PLUS, IR-Xe, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or MU-X or Polyflex SAP, Polyflex SAP FR
Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FRI:
6.4.1
6.4.2
Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Sections 1507
for the type of prepared roof covering to be Installed.
Direct -to -Deck with Mechanically Fastened Roof Covers:
All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP Cap
Sheet or SA-APP Cap Sheet (FR) should be back -nailed In selvage edge seam in accordance with Polyglass / Mule -Hide
Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch diameter
metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back -nailed using
the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane. The
head lap membrane is to cover the area being back -nailed
All seal -lap seams (selvage laps) must be
firmly rolled with a minimum 28 lb. hand
roller to ensure full contact and adhesion.
For Dual Pro and Tile Pro, align the edge of
the top sheet to the end of the glue pattern
(the sheet will overlap the fabric).
View of Ovelap Scam of Dual Pro and rile Pro
Exterior Research and Design, U.C. Evaluation Report P12060.02.09-R21
Certificate OfAuthorization #9S03 FBC NON-HVHZ EVALUATION FL5259-R25
Revision 21: 10/17/2016
Page 21 of 13
IF-ILE CUR -
TRINITY ERD
All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified
Wet/Dry Cement or Polyglass PGSOO Modified Cement applied in between the application of the lap.
Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys,
or exposed roof to wall details
Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or
Polyglass PGSOO Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the
Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be
installed in a water shedding manner.
All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a
minimum of 40-lb weighted -roller or, an steep slopes, use of a stiff broom with approximately 40-lbs of load applied
for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the
roof that are not accessible to a large roller or broom.
6.4.3 Tile Applications (not allowed foripolystickw-xe or Polystick MU-X):
Reference is made to FRSA/TRI April 2012 (04-12) installation Manual and Table I herein, using the instructions noted
above as a guideline.
For mechanically fastened tile roofing over 2-ply system, consisting of base sheet and self -adhering top sheet(s), base
sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1.
For adhesive -set tile applications, refer to Section 5.6.4 herein.
For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile.
For nail -on tile systems over Polystick MTS PLUS:
> Battens are required for loading/stagingof lugged tile regardless of slope.
> Battens are required for loading/staging of flat tile at slopes in excess of 5:12.
6.4.4 Two (21 Ply Underlayment Systems:
Polystick MTS or MTS PLUS followed by Poiystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Tile Pro, MU-X or Polyflex
SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with
the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired.
Polystick MTS PLUS followed by Polystick TU P, TU Plus, TU Max, Tile Pro or Polyflex SAP is allowable for use under
foam -on tile systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is
allowable if a 2-ply underlayment system is desired.
6.5 Elastoflex S6 G or S6 G FIR:
6.5.1 Elastoflex S6 G or S6 G FR shall be installed in compliance with current Polyglass published installation requirements.
For use in tile applications, reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table I herein.
6.5.2 Elastoflex SIS G or 56 G FR shall be fully asphalt -applied to the substrates noted in Section 5.6. Side laps shall be
minimum 3-inch and end -laps minimum 6-Inch wide, off -set minimum 3 feet from course to course. Side and end
laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch
beyond the lap edge.
6.6 Polyflex G or G FR:
6.6.1 Polyflex G or G FR shall be installed in compliance with current Polyglass published installation requirements. For use
in tile applications, reference is made FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein.
6.6.2 Polyflex G or G FR shall be fully torch -applied to the substrates noted in Section 5.6. Side laps shall be minimum 3-
inch and end -laps minimum 6-inch Mide, off -set minimum 3 feet from course to course. Side and end laps shall be
fully heat -welded and inspected to ensure minimum 3/8-Inch flow of modified compound beyond the lap edge.
6.7 Tile Staging:
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to
Polyglass published requirements for file staging.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R21
Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION FL5259-RZS
Revision 21: 10/17/2016
Page 12 of 13
FIL�Fm
TRINITY ERD
6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used
an all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nail -
boards, to prevent tile sliding and/or damage to the underlayment during the loading process.
6.7.3 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile.
6.7.4 For nail -on tile systems over Poiystick MTS PLUS:
> Battens are required for loading/staging of lugged tile regardless of slope.
> Battens are required for loading/staging of flat tile at slopes in excess of 5:12.
6.7.5 The minimum cure time after installation of seif-adhering membranes and before loading of roofing tiles is forty-eight
(48) hours.
7. BUILDING PERMIT REQUIREMENTS:
A:s required bythe Building Official orAuthority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contactthe noted QA agency for information on product locations covered for F.A.C. Rule 61G20-3 CIA requirements.
9. QUALITY ASSURANCE ENTITY:
UL, LLC— QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -