HomeMy WebLinkAboutPLANSVACUUMAIRTI. �21GX
OPERATOR, CONTRUL'AND BLOWER DETAILS
CALL 1-800-999-3600 13486G CUSTOMER UNIT DETAILS SEE PAGE 2 OF 8 FOR
38'
z
z z
zz
00
zz
ILI III
J�
TRAFFIC FLOW...
'0
Z� PLAN VIEW
A
13.. (T) DIX CONDUIT�
TO HOUSE OPTIONAL
CCTV CABLES
SEE VAT 21GX TYPICAL
SCHEMATIC USING ONE-WAY
AND TWO WAY CCTV SYSTEM
FILE NUMBER 178-2055
CO
UIL
0
LU
DUAL CALUSEND
INTERFACE FEATURE
0
g�
z
Lq
L-L
LISTINGSAND APP
(4) BOLLARDS RECOMMENDED- SIZE AND LOCATION
AS REQUIRED BY OWNER.
508 RECOMMENDED LOCATION FOR NEW CONSTRUCTION.
OUTLINE OF REQUIRED
CLEAR SERVICE AREA
38mm (IM CONDUIT TO STU&UP 51mm III')
ABOVE TOP OF ISLAND (FOR CONTROL, AUDIO
AND OPTIONAL CCTV CABLES)—
z
12
z
0
C)PRUI 0
ic
A!
45 1
NOTE:
USED WITH 13485G OPERATOR UNIT
r� OF CUSTOMER
UNIT
OR
iOFCONDUIT
13483 DUAL SIDED OPERATOR UNIT
DETAIL
A
SEE PAGE 2 AND 3 OF 8
MAXIMUM TUBE LENGTH 152 METERS
(WHEN CONTROL AND AUDIO CABLES
(500 LINEAR FEET)
ARE TO BE RUN UNDER TO UNDER)
13mm (y) DIA. CONDUIT TO HOUSE CONTROL AND AUDIO CABLES
IDENTIFICATION PANEL -
NUMBER AND COLOR CODED
CONTROLCABLE 'GG'CABLE #20 GAUGE STRANDED TINNED COPPER TO MATCH OPERATOR UNIT
7 CONDUCTOR. UNSHIELDED, 300V PPIPVC (19-200216-0062) BY DIEBOLD
AUDIO CABLE - 'DD' CABLE #20 GAUGE STRANDED TINNED COPPER,
3 SHIELDED TWISTED PAIRS, INDIVIDUP MFIL
IfflE
'AN VH DRAIN.
COLOR CODED (91-20D170-0082) BY DIE
---------- ----------- --
-------- BY
I -:)t. Lucie Counbf
IE OUNTI
S 'UG C
LAN R IEV�
ZOPTIONAL 13724 (GX)
CUSTOMER UNIT COL
AND COLOR DISPLAY
z I?
RECEIVED
DEC 2 8 20'6
PER.MrrrING
oulnt, FL
t2 Is
I FRONT VIEW
IE VIEW
"J.11EBOLff
VACUUMAIRI E21GX
13485G OPERATOR UNIT DETAILS
zz
00
w w
z z
w w
z 2
am
I
A
w
LL
0
N
U-I
CD
EL
71
ILI
CALL 1-800-999-3600
PLAN VIEW
NOTE:
MAX MUM TUBE LENGTH 152 METERS
(SOD LINEAR FEET)
114.m (4;�") Olk PNEUMATIC TUBE
OPERATOR CONTROL PANEL
iEND BUTTON: A MOMENTARY ACTION BUTTON, WHEN
-RESSED BY THE OPERATOR, DISPATCHES THE CARRIER
'0 THE CUSTOMER.
RING BUTTON: A MOMENTARY ACTION BUTTON WHEN
I
PRESSED BY THE OPERATOR. RECALLS THE CARRIER FROM
THE CUSTOMER UNIT (NOT N-FUGHT).
POWER SWITCH: TURNS SYSTEM ON AND OFF. BEFORE
SYSTEM IS TURNED OFF CARRIER MUST BE RETURNED
TO OPERATOR UNIT AND OPERATOR DOOR MUST BE OPEN
FRONT VIEW SIDE VIEW
Lib I INIJb ANU AJ'eKUVALb
• CLASSIFIED TO UL 345R SAFETY OF
INFORMATION TECHNOLOGY EQUIPMENT
• UL TESTED TO THE FOLLOWING STANDARDS'
UL 114 OFFICE APPLIANCE & BUSINESS
EQUIPMENT, ILL 50 RAIN TEST SPECIFICATION
• UNDERWRITERS LABORATORIES (UL)
CORPORATE HEADQUARTERS
333 PFINGSTEN ROAD
NORTHBROOK, IL 60062-2096
CUSTOMER CONTROL PANEL X 2
SEND BUTTON:A MOMENTARY ACTION BUTTON. WHEN
PRESSED BY THE CUSTOMER, DISPATCHES THE CARRIER
TO THE OPERATOR.
CALL BUTTON: A MOMENTARY ACT10N BUTTON, WHEN
PRESSED BY THE CUSTOMER, ACTIVATES THE AUDIO
CHIME, INDICATING COMMUNICATION IS DESIRED.
LOCATION ABOVE AND BELOW CARRIER ACCESS
TYPICAL TRANSACTION
CUSTOMER ARRIVES AT THE CUSTOMER UNIT, WITH DOOR OPEN AND THE
CARRIER PRESENT. CUSTOMER PLACES TRANSACTION INSIDE CARRIER, AND
PRESSES SEND BUTTON. BLOWERS ENERGIZE AND THE CARRIER IS DISPATCHED
TO THE OPERATOR. UPON ARRIVAL AT THE OPERATOR, THE OPERATOR TERMINAL
DOOR WILL OPEN AND TH E CUSTOMER UNIT DOOR WILL CLOSE.
MPLE TIES THE TRANSACTION, THE CARRIER IS PLACED
IAL, AND THE SEND BUTTON IS PRESSED. BLOWERS
IER IS DISPATCHED TO THE CUSTOMER. AFTER THE
CUSTOMER UNIT. THE CUSTOMER UNIT DOOR WILL
R UNIT DOOR WILL CLOSE.
MULTIPLE UNIT CONFIGURATION
SIDE VIEW
PLAN VIEW
(4) UNITS
(2) UNITS
(3) UNITS
VACUUMAIRTUBE' GXSYSTEM
13660 DUAL SIDED OPERA i OR UNIT DETAILS
065
w w
mz
UI
It
m
z z
00
0 m
z z
w III
22
00
pow
fl 0
z I-
L)
ucl-�)
00
LL
0
m
LU
aw
0
z
CALL 1-800-999-3600
114 (4T) DIA. OPERATOR CONTROL PANEL
PNEUMATIC TUBE SIDE WITH
POWER 4pmww
SWITCH I
SIDE WITH --Myb� I
No POWER
SWITCH L 11 1
SEND BUTTON: A MOMENTARY ACTION BUTTON, WHEN
102 102
PRESSED BY THE OPERATOR, DISPATCHES THE CARRIER
(4') (4')
TO THE CUSTOMER.
204
BRING BUTTON: A MOMENTARY ACTION BUTTON, WHEN
M
PRESSED BYTHE OPERATOR, RECALLS THE CARRIER FROM
PLAN VIEW
THE CUSTOMER (NOT IN-FLIGHT).
POWER SWITCH: LOCATED ONLY ON ONE SIDE OF THE
UNIT. TURNS SYSTEM ON AND OFF. BEFORE
SYSTEM IS TURNED OFF CARRIER MUST BE RETURNED
TO OPERATOR UNIT AND OPERATOR DOOR MUST BE OPEN.
COUNTERTOP
FRONT VIEW
CONDUITTOHOUSE
CABLE, -GG' CABLE
#20 GAUGE STRAND[
TINNED COPPER, 7 C
UNSHIELDED, 300V P
(91 .200216-0062) BY I
229
SIDE VIEW
CUSTOMER CONTROL PANEL X 2
SEND BUTTON: A MOMENTARY ACTION BUTTON. WHEN
PRESSED BY THE CUSTOMER, DISPATCHES THE CARRIER
TO THE OPERATORL
CALL BUTTON: A MOMENTARY ACTION BUTTON, WHEN
PRESSED BY THE CUSTOMER, ACTIVATES THE AUDIO
CHIME, INDICATING COMMUNICATION IS DESIRED.
LOCATION ABOVE AND BELOW CARRIER ACCESS
ICA ully.-M ftzlilk 14iffoil d W �
CUSTOMER ARRIVES AT THE CUSTOMER UNIT, WITH THE DOOR OPEN AND THE
CARRIER PRESENT. CUSTOMER PLACES TRANSACTION INSIDE CARRIER, AND
PRESSES SEND BUTTON. BLOWERS ENERGIZE AND THE CARRIER IS DISPATCHED
TO THE OPERATOR. UPON ARRIVAL AT THE OPERATOR, THE OPERATOR TERMINAL
DOOR WILL OPEN AND TH E CUSTOMER UNIT DOOR WILL CLOSE.
WHEN THE OPERATOR COMPLETES THE TRANSACTION, THE CARRIER IS PLACED
IN THE OPERATOR TERMINAL, AND THE SEND BUTTON IS PRESSED, BLOWERS
ENERGIZE, AND THE CARRIER IS DISPATCHED TO THE CUSTOMER. AFTER THE
CARRIER ARRIVES IN THE CUSTOMER UNIT, THE CUSTOMER UNIT DOOR WILL
OPEN, AND THE OPERATOR UNIT DOOR WILL CLOSE.
TUBE
MULTIPLE UNIT CONFIGI
ALTERNATE OPERATOR UNIT INSTALLATION
VIEW
PLAN VIEW (2) UNITS
PLAN VIEW (3) UNITS
PLAN VIEW (4) UNITS
VACUUM AIF ' -''IBE21GX
TYPICAL DRIVE -UP IN5TALLATION USING
TRANSACTION DRAWER AND (1) VAT 21GX SYSTEM
F -CALL 1-800-999-3600
o
NOTE:
MAX MUM TUBE LENGTH 152 METERS
I
'LINEAR
�_
(i 4YDIA.
(500 FEET)
TUBE
235 TRAFFIC
al w
#13486GVAT21GX
CUSTOMER UNIT
0
?9 FLOW
W
NOTE:
W
W
CHASE AND LOCATION AS REQUIRED
89mN3%aD71A LrXIBLE-
z
(BY OWNERS G.C.) SIZED TO HOUSE ALL
E 6�F
AIR LI m IT) RIGID
z
INTERCONNECTING CONTROUAUDIO CABLES
PVC TUBING
z z
9 Q #13485GVAT21GX CHASE
z z OPERATOR UNIT
SHOWN.
-
--------- CLTRANSACTION DRAWER ----- --
---- -------
-OPERATOR/CUSTOMER UNIT
BLOWER PACKAGES. OWNERS G.C.
TO PROMDE SERVICE ACCESS
Z
(LOCATION CAN VARY)
, 0 N7
TRAFFIC
J
z
52 CURB FLOW ..
M 0
660
(6')
2591 610
e
2591
(2-2)
w
U_
0
Lu
(D
d
z
PLAN VIEW
NOTES:
i. ALL WORK AND MATERIALS SHALL CONFORM TO THE NATIONAL,
ALL STATE, AND LOCAL ELECTRICAL CODES WHICH MAY BE APPLICABLE.
ELECTRICAL CONTRACTOR TO BE RESPONSIBLE FOR ANY CHANGES
NECESSARY TO COMPLY WITH THESE CODES.
2. ALL CONDUIT, POWER WIRES, JUNCTION BOXES, AND OVERLOAD PROTECTION
DEVICES, ARE TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOP-
I I 70mm (2)4") MIN. TO OBSTRUCTION
F /- TUBE SUPPORT SYSTEM
OPERATORICUSTOMER UNIT
BLOWER PACKAGES (LOCATION
CAN VARY)
#13485G 21GX
OPERATOR UNIT
SHOWN C?
�TRANSACTION DRAWER
4
762mm (Z-6") MINIMUM
CLEARANCE HEIGHT
REQUIRED TO CONCEAL
TUBE RADII AND CLAMPS
NOTE:
GENERAL CONTRACTOR TO PROVIDE
ACCESS TO BLOWER PACKAGE
ANDTLIBESYSTEM
114mm (4�") DIX CLEAR PLASTIC TUBING
21M (r4-) STANDARD
3G48 (10'-0-) OPTIONAL
—1 - #1348BG VAT T[GX CUSTOMER UNIT
ALL DIMEYNSIWMARKE�WITH AN �AS_MRISK
SECTION/ELEVATION MAY VAR W UU_D".,�.PY..N.T,.CTI..
05
ww
z
w
z z
00
w m
z z
w w
:2 2
an
z
'o
0
VACUUMAIRTI "21GX
13486G CUSTOMER ui�ff DETAILS
"s.. wEBMW FIRST LANE OR WALL RECESS INSTALLATION
CALL 1-800-999-3600
NOTE:
DETAILS SHOWN ARE FOR VAT 21GX INSTALLATIONS WHERE CUSTOMER'S SITE CONDITIONS REQUIRE THE
CUSTOMER UNIT POSITIONED IN THE FIRST LANE AND/OR AGAJNST THE BUILDING WALL
DETAILS SHOWN ARE FOR ILLUSTRATION ONLY AND ACTUAL SITE CONDITIONS MUST BE VERIFIED BEFORE INSTALLATION
SEE SHEET 4 OF 8 FOR TYPICAL DRIVE -UP SCENARIO.
TRAFFIC FLOW ... >
CO
UL
0
m
UILI
OL
z
w
—OUTUNE OF REQUIRED
CLEAR SERVICE AREA
/X7
,\\/7777/777�, \/,(/
PLAN VIEW - FIRST LANE MINIMUM CURB
(2) BOLLARDS RECOMMENDED.
SIZE AND LOCATION AS REQUIRED
BY OWNER. RECOMMENDED LOCATION
FOR NEW CONSTRUCTION.
PLAN VIEW - MINIMUM WALL RECESS
w �i
w w
W z
A
It w
z z
z z
LU w
22
mo
on
.A
z
m
LL
0
LU
OL
41022812 VACUUM AIR TUBE 3X CONTROL BOX
".111EBOLDr AND
BLOWER PACKAGE ASSEMBLY
CALL 1-BOO-999-3600
TRANSFORMER CABLE-'HHm CABLE
#20 GAUGE STRANDED TINNED COPPER.
2 CONDUCTOR. PVC INSULATION. TWISTED,
WITH SHIELD, 300V (91-200212mOO62)
BY DIEBOLD
133
Pyl)
(A,
PLAN VIEW
BLOWER CONTROL CABLE -.HH- CABLE
#20 GAUGE STRANDED TINNED COPPER
2 CONDUCTOR, PVC INSULATION, TWISTED,
WITH SHIELD, 300V (,I.2DO212-0062) BY
DIEBOLD
CONTROL CABLE - 'GG' CABLE
#20 GAUGE STRANDED TINNED COPPER
7 CONDUCTOR, UNSHIELDED, 300V PP/PVC
(91-200216-0062) BY DIEBOLD
TRANSFORMER CABLE
1828 (6'-0-)
A
B
FRONT VIEW
SIDE VIEW
NOTE:
LOCATE IN OPERATORS KNEE SPACE AREA
BACK VIEW
VACUUM AIR TUBE 21 GX CONTROL BOX
:RS
PLAN VIEW
NOTE:
BLOWER CAN BE MOUNTED VERTICALLY.
BLOWER WEIG14T 3.3 kg (7.2 LES.)
CLEARANCE
RECOMMENDED
FOR SERVICING
BLOWERS
1,624mm (6-0') OF FLEXIBLE CONDUI� TO ALLOW FOR 1
FRONT VIEW SERVICEABILITY (BY OWNERS E.C.). CONDUIT MAY BE REQUIRED
WHEN LOCAL CODES SPECIFY HARD WIRE INSTALLATION.
OWNERS E.C. TO PROVIDE"DISCONNECT'SWITCH TO BLOWER
WHEN HARD WIRED. SEE CUT SHEET FILE NUMBER 178-2080 FOR
HARD WIRED INSTALLAnON REQUIREMENTS.
. wo
PERSPECTIVE
(0) 10.m W) DIA. HOLES FOR
BLOWER HANGERS OR MOUNTING
SIDE VIEW
VACUUM AIR TUBE 21 GX BLOWER PACKAGE ASSEMBLY
CALL 1-800-999-3600
BEAM
W
2 7mm (Y,"-20)
-1
ww
8.m -18) V HOOK
-w LOCALPURCHASE
z
00
8mm (�16-
LOCAL P�
z z
w w
� 2 1 0
cc
ld7
0 0
wz
,0
Z�
0 SECTION VIEW
DIRECT MOUNTING
WOOD TRUSS OR BEAM
VACUUM AIR lbuE 21 GX
BLOWER PACKAGE MOUNTING DETAILS
BLOWER MOUNTING FROM SUSPENDED UNISTRUT
AND 6mm (1/4"-20) THREADED ROD
CABLES
I
------------- — bi ---------------------
0
L
8mm 0',��18) F � (-Y,,%18)"J'HC
U.1 "J* HOOKS OCAL PURCHASE
LOCAL PURCHASE
Z�
OL
(,P
1829..
(6'-0') LONG 1
POWER
CORDS
..............
mm (%e)
S. HOOK
LOCAL
CH S
5 8mm (910 89 mm (3%') AIRLINE
2 "S'HOOK TO PNEUMATIC TUBE 8.m 'S'HOOKS -
2 LOCAL LOCAL PURCHASE
PURCHASE AIR NIPPLE
...................
c�
..................
cc
0 0
7 9 UO
89 mm (3Y) AIRLINE -/
z TO PNEUMATIC TUBE
SECTION VIEW
AIR NIPPLE FRONT VIEW
BLOWER MOUNTING FROM SUSPENDED UNISTRUT SUPPORT WITH HANGERS
VACUUM AIR -BE 21 GX
CONTROL AND AUDIO SCHEMATIC DETAILS
0 �i
III w
w
ww
zz
00
w w
zz
ww
m 2
00
I
A
m
LL
0
m
LU
Q)
EL
w
z
LL
CALL 1-800-999-3600
CONTROL CABLE - *GG' CABLE
420 GAUGE STRANDED TINNED COPPER,
7 CONDUCTOR, UNSHIEUDED, 30DV PP/PVC
(91-200215-0062) BY DIEBOLD
CONTROL
BOX
FLEXIBLE HOSE
L
(AIR 1-14NE
BLOWER
PACKAGE
OPTIONAL TUBE
HEATER
FLEXIBLE HOSE
(AIR LINE)
BUILDINGS AUDIO UE-'DD"CABUE
ELECTRICAL 8 ' U .. 0 112B GAUABE STRANDED TINNED COPPER,
SUPPLY C OL 3 SHIELDED TWISTED PAIRS, INDIVIDUAL
M DULE FOIL SHIELDS WITH DRAIN, COLOR CODED
W45 INTERCONNECTNG (91-20017MO62) BY DIEBOLD
CMLE4.267 METERS I j
02PTIONAL CUSTOMER DOOR RAIL HEATER
(2�01686�00A) A # 0 GAUGE STRANDED TINNED COPPER,
2 %0NDUCTOR. PVC INSULATION, TWISTED,
W ELD, 300V (91-200212-0052)
'HH' CABLE BY DIEBOLD
8�O'POWERCORD OR ...f
DUAL SIDED
AUDIO SWII CHER BOX .1. UNIT
CUSTOMER
OPERATOR UNIT
LOCATE IN OPERATORS KNEE SPACE AREA UNIT
SCHEMATIC FOR CONTROL/AUDIO CABLES OVER TO OVER
NOTE:
OWNERS ELECTRICAL CONTRACTOR TO PROVIDE (1 ) DUPLEX OUTLET AT EACH 'A'
ON (1) 120 VAG. 60 HZ, SINGLE-PHASE (3W). 20 AMP DEDICATED BRANCH CIRCUIT
SEE CUT SHEET FILE NUMBER 178-2080 FOR HARD WIRED
INSTALLATION REQUIREMENTS.
SEE CUT SHEET FI UE NUMBER 178-1953 FOR POWER CONSOLIDATION AND
DISTRIBUTION GUIDELINES.
CONTROL CABLE -'GG"CASUE
#20 GAUGE STRANDED TINNED COPPER CONTROL CABLE - 'GG' CABLE
SLOWER CONTROL CABLE -"HH'CABLE
#20 GAUGE STRANDED TINNED Cl
7 CONDUCTOR, UNSHIELDED jp�c OPPER.
Ppi
GAUGE STRANDED TINNED COPPER,
.3000)V
(91-200216-0062) BY DIE 7 CONDUCTOR, UNSHIEUDED, 300
2 CONDUCTOR, PVC INSULATION, TWISTED
(91-200216-0062) BY DIEBOLD ///f#20
WITH SHIELD, 300V (91-200212-0062) BY DIEBOLD
TUBE
V---OPTIONAL
HEATER
CONTROL
BOX
BUILDINGS �;� fl:-816AUOIO
ELECTRICAL CONTROL
SUPPLY MODULE
OPTIONAL CUSTOMER DOOR RAIL HEKrER
#20 GAUGE STRANDED TINNED COPPER,
2 CONDUCTOR, PVC INSULATION. TWISTED,
WITH SHIELD. 300V (91-200212-0062)
'HK' CABLE BY DIEBOLD
RELOCATION IN CANOPY. OPTIONAL
LOCATION IN OPERATORS KNEE SPACE
AREA
FLEXIBLE HOSE
(AIR LINE)
BLOWER
PACKAGE
< ..........
OR
DUAL SIDED
� UNIT A
OPERATOR UNIT
SWITCHER BOX
BLOWER
PACKAGE
AUDIO CABLE -'DO'CABLE
420 GAUGE STRANDED TINNED COPPER,
3 SHIELDED TWISTED PAIRS, INDIVIDUAL
FOIL SHIELDS WITH DRAJN, COLOR CODED
(91-20017G.0062) BY DIEBOLD
(AIR LINE)
CUSTOMER
1 38m. (I I�') CONDUIT REQUIRED UNIT
LOCATE IN OPERATORS KNEE SPACE AREA (1) PER CUSTOMER UNIT
SCHEMATIC FOR CONTROL/AUDIO CABLES UNDER TO UNDER