Loading...
HomeMy WebLinkAboutCERTIFICATIONAdvanced Architecture & Planning LLC Architect & Planning 4929 S. Indian River Drive Ft. Pierce, FL 34982 (772)631-5709 Sliding Glass Door Replacement Certification: December 19,2016 Bill Laprade Glass Professionals 6GANNEL) Stuart, Florida. Cell: 772-745-3459 13Y Email: glassprofessionals@gmail.com St- LUde C01inh, Proiect: Sliding Glass Door Replaceme 9600 S. Ocean Drive, Suite 20 1, Jensen Beach, FL 34957 Dear 1W. Laprade: Please know I personally completed the wind load analysis for the new vinyl, sliding glass door, NOA, 15- 1210.02 by PGT, Series 5470, vinyl, non -impact rated doors. This suite has existing accordion type shutters. Using the ASCE7-10. The following parameters were used: Single vinyl sliding glass door height is less than 20 feet; Exposure D; Wind speed 170 mph; Enclosed Structure, wind zone 5; When taking into account the external and internal pressure coefficients and adjustments per the ASCE7-10, the resulting and governing applied wind pressure comes to +52.3 psf / -57.4 psf for Zone 5. With the fasteners spacing, edge distances and embedment and door installation completed per the respective NOA, the allowable loads of +1-65.8 psf for this door exceeds the applied loads in this application, and is acceptable to my office. It is recommended that all fasteners be of high quality stainless steel. If you have any questions, please contact me at any time. Thank you, kaymond Chladny, B.aich,�c., M.arch, AIA, NCARB, LicA AA26002573