Loading...
HomeMy WebLinkAboutPLANS1. APP&ABLE C06E: 2014 FLORIDA BUILDING CODE (STH EDITION) & ASCE-7.10 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES. 2. BOLT DIAMETER AND EMBEDMENT LENGTHS ARE DESIGNED PER 2014 FLORIDA BUILDING CODE (5TH EDITION) REQUIREMENTS. ALL BOLT CAPACITIES ARE BASED ON A SOUTHERN YELLOW PINE (SYP) RESIDENTIAL WOOD ROOF TRUSS AS EMBEDMENT MATERIAL. 3. ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLE RESIDENTIAL ROOFS, CONSIDERING FROM A 7" TO A MAXIMUM 27 " (2/12 TO A MAXIMUM 6/12 PITCH) ROOF IN SCHEDULE. ALL RESIDENTIAL ROOFS SHALL NOT TO EXCEED 30'-0' MEAN ROOF HEIGHT. 4. WIND TUNNEL TEST DATA FOR THIS COLLECTOR MAY BE REQUESTED THROUGH UMA SOLAR, INC. AND HAS BEEN COMPILED BY PRI CONSTRUCTION AND MATERIAL TESTING, INC. S. ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511, AND IS THE RESPONSIBILITY OF THE CONTRACTOR TO PILOT FILL ALL HOLES. 6. THIS SHEET REFLECTS STRUCTURAL CONNECTIONS ONLY. REFER TO HELIOCOL INSTALLATION MANUAL FOR ALL ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND SOLAR SPECS. 7. LAG BOLTS SHALL BE ASTM A276 TYPE 304 STAINLESS STEEL UNLESS OTHERWISE NOTED. B. ALL HELIOOOL COLLECTOR MODELS MAY BE INSTALLED PER THIS STRUCTURAL CONNECTION DRAWING. 9. PVC PIPE RISER/SPACER IS REQUIRED FOR PIPE a -AMPS WHERE PIPE ELEVATION VARIES. 10. CONTRACTOR SHALL ENSURE ALL ROOF PENETRATIONS TO BE INSTALLED AND SEALED PER 2014 ULTIMATE Vm WIND Vm WIND Vm WIND QUANTITY OF LAG EMBEDMENT WIND SPEED PRESSURES PRESSURES PRESSURES BOLTS - CLAMPS DEPTH REQ. Vm (MPH) ZONE 1(PSF) ZONE 2 (PSF) ZONE 3* (PSF) PER COLLECTOR I10-160 22.4,-35.4 22.4,-61.7 22A,-91.3* (4)q'DIA. -(4)CLAMPS 2"** 161-175 26.9 ,-42.7 26.9 ,-74.3 26.9,-109.9 1 (4)1 DIA. - (4) CLAMPS 3' ** - PLUS AND MINUS SIGNS SIGNIFY PRESSURES ACTING TOWARD AND AWAY FROM SURFACES, RESPECTIVELY. - SCHEDULE REFLECTS COMPONENTS AND CLADDING (C&C) NOMINAL WIND SPEED PRESSURES WITH EXPOSURE'C', RISK CATEGORY II, ENCLOSED BUILDING AND h < 60'-0" PER ASCE 7-10'MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES" AND 2014 FLORIDA BUILDING CODE. - EFFECTIVE DESIGN WIND AREA IS 12.5 SF PER COLLECTOR FOR HC-50. - MINIMUM Vm WIND PRESSURE SHALL BE 16.0 PSF AND -16.0 PSF PER ASCE 7-10 SECTION 30.2.2. ** LAG BOLT DEPTH REQUIRED IN WOOD MEMBER SHALL EXCLUDE ANY ROOF DECKING THICKNESS. * INSTALLATION OF COLLECTORS MUST BE LOCATED IN ROOF WIND ZONE I AND 2. WIND ZONE 3 REQUIRES SITE SPECIFIC STRUCTURAL ENGINEER'S APPROVAL. END CAP HELIOCOL SHORT CLAMP O.C. TYR HELIOCOL COLLECTOR RISER SYSTEM TYP. 11r1 rnl l I l ,. LI,1C TYPICAL HELIOCOL CLAMP. REFER TO SCHEDULE FOR BOLT SIZE PER DETAIL THIS SHEET COLLECTOR ARRAY HELIOCOL SHORT CLAMP T-0" O.C. TYP. HELIOCOL COLLECTOR RISER SYSTEM TYP. HELIOCOL LONG CLAMP 2'-01, O.C. TYP. (2) #6 HEX SCREWS - 4' LENGTH TYP PER_\ HELIOCOL CLAMP ROOF ASPHALT SHINGLES OR SV METAL ROOF TYP. WOOD SHEATHING TYP — a" DIA. ST STL LAG BOLT - SEE SCHEDULE FOR EMBED. DEPTH REQ. TYP. EACH CLAMP REFER TO SCHEDULE FOR REQUIRED EMBEDMENT DEPTH LABELED "X" IN THIS DETAIL 'OP - BOTTOM ASPHALT - METAI SHINGLE CONNECTION WOOD SHEATHING TYP S.Y.P. 2X4 LOCATE BETWEEN - TRUSSES AND NAIL WITH 2-16D NAIL PATTERN AT EACH END TO WOOD TRUSS 170 ASSEMBLY. RE -INSTALL, RE -FILL AND RE -SEAL AFFECTED WITH APPROVED ROOF MATERIALS IV 49g3[Ql'Iy:10bill 14IX11 (2) #6 HEX SCREWS - LENGTH TYP PER CLAI "UMA SOLAR" LIFT KIT TYP PER CLAMP HELIOCOL SHORT CLAMP 2'-0" O.C. TYP. s HELIOCOL PANEL RISER SYSTEM TYP. HELIOCOL � LONG CLAMP T-O" O.C. s TYP. \ " WOOD SHEATHING .3 FLAT OR BARREL TILE TYP. Y \—q" DIA. ST STL LAG BOLT - SEE #2 S.Y.P. WOOD SCHEDULE FOR EMBED. DEPTH ROOF TRUSS TYP. REQ. TYP. EACH CLAMP OPTIONAL FLAT TILE - BARREL TILE ROOF CLAMP TOP CONNECTION DETAIL%3� SCALE: 1"=V-0" HC-2 (U� t I1DCD SHORT CLAMP O Z Q-0" O.C. TYR HELIOCOL COLLECTOR RISER SYSTEM TYP. HELIOCOL LONG CLAMP T-O" O.C. TYP. (2) #6 HEX SCREWS a' LENGTH TYP PER HELIOCOL CLAMP \—WOOD ROOF TRUSS TYP. SCANNED BY St. Lucie Countv `WOOD ROOF TRUSS TYP. ROOF ASPHALT SHINGLES ROOF ASPHALT OR 5V METAL ROOF SHINGLES OR TYP. 5V METAL ROOF TYP. '.'DIA. ST STL LAG WOOD SHEATHING TYP 2X PT S.Y.P. WOOD BOLT - SEE SCE. FOR EMBED. DEPTH OR ALUMINUMn REQ.TYP.EACH a DIA ST STL ALL-THRD ROD UNISTRUT C NN jv W/ NUT -WASHERS MAX. 3'-0" ALONG CO\ CLAMP REFER TO SCHEDULE FOR REQUIRED EMBEDMENT DEPTH LABELED "X"IN THIS DETAIL OPTIONAL WOOD SPANNER OPTION CONNECTION DETAIL 5 SCALE: 1"=V-0" . HG2 O.C: LOCTITE ALL NUTS TYP. ALL CONNECTIONS LIMITED SPACE OPTION FOR UNALIGNED TRUSS OPTIONAL ALL THREAD CONNECTION DETAIL we I PROJECT: w J w z cn x 0 N F, U W Z w2z JO o=z n�o Z?¢� ce ,i'x � �L w J C3 J oo�o J � LL ¢ a =oww 0 1—I w (~z�ir xa¢aa I 16-16Y: JAT JAT# 29127SNOTED DEC i,2.2016