Loading...
HomeMy WebLinkAboutPLANSRECER'-D JAN 10 2017 M 160XC244 - A • M�, 5��'E�,��MIDWAY T0WE F RONT SBA# FL10049—A SIDES Sprint' CNR SID REAR TM 375 E MIDWAY ROAD LTECH& FORT PIERCE, FL 34982 2.5GHz EQUIPMENT DEPLOYMENT LOCAL MAP PROPERTY SUMMARY PROJECT DESCRIPTION INDEX OF DRAWINGS -� - fV�e� p FOLIO 3403 502 0055 020 3 - - - - 1 THE WIRELESS COMMUNICATIONS FACILITY IS NOT ED FOR HUMAN CREQUI �NFACILITY SHT. DESCRIPTION REV NO. TO1 TITLE SHEET if PROPERTY OWNER 0. DOES NOT E POTABLE WATER AND WILL NOT PRODUCE ANY SEWAGE T2 SPRINT SPECIFICATIONS 0 it T( r n —.. kil¢ = SBA TOWERS II, LLC. TAX DEPARTMENT 5900 BROKEN SOUND PARKWAY NW BOCA RATON, FL 33487 3. CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND -SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. T3 SPRINT SPECIFICATIONS 0 C7 C2 COMPOUND PLAN ELEVATION 0 0 '• III I.. SfiE LOCATON o LATITUD 27.3737fi0 N LONGITUDE 80.322445 W 14. THE SCOPE OF WORK CONSISTS OF MODIFYING THE EXISTING WIRELESS INSTALLATION: INSTALLATION OF (3) NEW PANEL ANTENNAS INSTALLATION OF (3) NEW RRUS (REMOTE RADIO UNITS) INSTALLATION OF (1) NEW HYBRID CABLE C3 ANTENNA LAYOUTS 0 C4 DETAILS 0 C5 DETAILS 0 E1 GROUNDING DETAILS AND NOTES 0 ' [•� _ - ZONING JURISDICTION INSTALLATION OF (1) NEW DISTRIBUTION UNIT ST LUCIE COUNTY SPRINT PROGRAM MANAGER DENNIS CZARNYSZKA e o..,.�..�., 9 (904) 928-1785 VICINITY MAP DESIGN CRITERIA CODE COMPLIANCE BY i� L i f ` ffi <_. 4 ' s DESIGN WIND SPEED: 160 MPH (ULTIMATE, 3-SECOND GUST) 124 MPH (NOMINAL, 3-SECOND GUST) EXPOSURE: C RISK CATEGORY: II OPEN STRUCTURE ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO 8E CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. I i. FLORIDA BUILDING CODE, 5th EDITION (2014). 2. NATIONAL FIRE NATIONAL ELECTRICAL OCODE, 20111 TION wEDITIOTION NNFPA) 70-U, 3. TIA-222-G WITH ADDENDUM 1 AND 2 APPLICABLE STANDARDS. 4. UFE SAFETY CODE NFPA-101-2012. S. FLORIDA FIRE -PREVENTION CODE, 5th EDITION (2014). 6. AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) 360-10 AND 341-10. i.Lucie County ; 4j a 7. UNDERWRITERS LABORATORIES (U.L) APPROVED ELECTRICAL PRODUCTS. 8. LOCAL JURISDICTIONAL REQUIREMENTS. 9. CITY/COUNTY ORDINANCES. CALL 48 HOURS BEFORE YOU DIG �- -MR IT'S THE LAW ! 1-800-432-4770 mn SUNSHINE STATE ONE CALL OF FLORIDA, INC. I , 4 REV DATE I DESCRIPTION A 3/31/141 PREUMINARY 0 6/2/141 FOR PERMIT 1 11/14/16 REVISED PROJECT NO.: 140-905.02 DFWWN BY: CHECKED BY: J. ACOSTA M. ABBEY THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF THE OWNER. M IS PRODUCED SOLELY FOR USE BY THE OWNER AND ITS AFFILIATES. REPRODUCDON OR USE OF THIS DRAWING AND/OR THE INFORMATION CONTAINED IN R IS FORBIDDEN WTOIOUT THE WRfOEN PERMISSION OF THE OWNER ' I THESE OUTLINE SPECIFICATIONS IN CONJUNCTION WITH THE SPRINT STANDARD CONSTRUCTION SPECIFICATIONS, INCLUDING CONTRACT DOCUMENTS AND THE CONSTRUCTION DRAWINGS DESCRIBE THE WORK TO BE PERFORMED BY THE CONTRACTOR. SECTION 01 100 — SCOPE OF WORK THE WORK: SHALL COMPLY WITH APPLICABLE NATIONAL CODES AND STANDARDS, LATEST EDITION, AND PORTIONS THEREOF. PRECEDENCE: SHOULD CONFLICTS OCCUR BETWEEN! THE STANDARD CONSTRUCTION SPECIFICATIONS FOR WIRELESS SITES INCLUDING THE STANDARD CONSTRUCTION DETAILS FOR WIRELESS SITES AND THE CONSTRUCTION DRAWINGS, INFORMATION ON THE CONSTRUCTION DRAWINGS SHALL TAKE PRECEDENCE. SITE FAMILIARITY'. CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH ALL CONTRACT DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS PRIOR TO PROCEEDING WITH CONSTRUCTION. ON —SITE SUPERVISION, THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. DRAWINGS SPECIFICATIONS AND DETARS REQUIRED AT OB THE CONSTRUCTION CONTRACTOR SHALL MAINTAIN A FULL SET OF THE CONSTRUCTION DRAWINGS AT THE JOBSITE FROM MOBILIZATION THROUGH CONSTRUCTION COMPLETION. A DETAILS ARE INTENDED TO SHOW DESIGN INTENT. PROVIDE ALL MATERIALS AND LABOR AS REQUIRED TO PROVIDE A COMPLETE AND FUNCTIONING SYSTEM. MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. B. CONTRACTOR SHALL NOTIFY SPRINT CONSTRUCTION MANAGER OF ANY VARIATIONS PRIOR TO PROCEEDING WITH THE WORK.DIMENSIONS SHOWN ARE TO FINISH SURFACES UNLESS NOTED OTHERWISE. MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. C. MARK THE FIELD SET OF DRAWINGS IN RED, DOCUMENTING ANY CHANGES FROM THE CONSTRUCTION DOCUMENTS. METHODS OF PROCEDURE (MOPS) FOR CONSTRUCTION - CONTRACTOR SHALL PERFORM WORK AS DESCRIBED IN A COAX COLOR CODING SWEEPS AND FIBER TESTING TS-0200 AND EL-0568 B. CABLE LABELING EN-2012-00 C. APPLICABLE INSTALLATION MOPS IDENTIFIED ELSEWHERE IN THE CONTRACT DOCUMENTS SECTION 01 200 — COMPANY FURNISHED MATERIAL AND EQUIPMENT COMPANY FURNISHED MATERIAL AND EQUIPMENT IS IDENTIFIED ON THE RF DATA SHEET IN THE CONSTRUCTION DRAWINGS. CONTRACTOR IS RESPONSIBLE FOR SPRINT PROVIDED MATERIAL AND EQUIPMENT TO ENSURE IT IS PROTECTED AND HANDLED PROPERLY THROUGHOUT THE CONSTRUCTION DURATION. CONTRACTOR RESPONSIBLE FOR RECEIPT OF SPRINT FURNISHED EQUIPMENT AT CELL SITE OR CONTRACTORS LOCATION. CONTRACTOR TO COMPLETE SHIPPING AND RECEIPT DOCUMENTATION IN ACCORDANCE WITH COMPANY PRACTICE. SECTION 01 300 — CELL SITE CONSTRUCTION NOTICE TO PROCEED: NO WORK SHALL COMMENCE PRIOR TO COMPANY'S WRITTEN NOTICE TO PROCEED AND THE ISSUANCE OF WORK ORDER. SITE CLEANLINESS: CONTRACTOR SHALL KEEP THE SITE FREE FROM ACCUMULATING WASTE MATERIAL, DEBRIS, AND TRASH. AT THE COMPLETION OF THE WORK, CONTRACTOR SHALL REMOVE FROM THE SITE ALL REMAINING RUBBISH, IMPLEMENTS, TEMPORARY FACILITIES, AND SURPLUS MATERIALS. SECTION 01 400 — SUBMITTALS h TESTS ALTERNATES: AT THE COMPANY'S REQUEST, ANY ALTERNATIVES TO THE MATERIALS OR METHODS SPECIFIED SHALL BE SUBMITTED TO SPRINTS CONSTRUCTION MANAGER FOR APPROVAL SPRINT WILL REVIEW AND APPROVE ONLY THOSE REQUESTS MADE IN WRITING. NO VERBAL APPROVALS WILL BE CONSIDERED. TESTS AND INSPECTIONS: A THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION TESTS, INSPECTIONS AND PROJECT DOCUMENTATION. B. CONTRACTOR SHALL ACCOMPLISH TESTING INCLUDING BUT NOT LIMITED TO THE FOLLOWING: 1. COAX SWEEPS AND FIBER TESTS PER TS-0200 REV 4 ANTENNA LINE ACCEPTANCE STANDARDS. 2. AGL, AZIMUTH AND DOWNTILT PROVIDE AN AUTOMATED REPORT UPLOADED TO ST'ERRA USING A COMMERCIAL MADE —FOR THE PURPOSE ELECTRONIC ANTENNA ALIGNMENT TOOL (MT). INSTALLED AZIMUTH, CENTERUNE AND DOWNTILT MUST CONFORM WITH RF CONFIGURATION DATA 3. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY AND ALL CORRECTIONS TO ANY WORK IDENTIFIED AS UNACCEPTABLE IN SITE INSPECTION ACTIVITIES AND/OR AS A RESULT OF TESTING. 4. ALL TESTING REQUIRED BY APPLICABLE INSTALLATION MOPS. C. REQUIRED CLOSEOUT DOCUMENTATION INCLUDES, BUT IS NOT LIMITED TO THE FOLLOWING; 1. AZIMUTH, DOWNTILT, AGL FROM SUNSIGHT INSTRUMENTS — ANTENNAUGN ALIGNMENT TOOL (AAT) 2. SWEEP AND FIBER TESTS 3. SCALABLE BARCODE PHOTOGRAPHS OF TOWER TOP AND INACCESSIBLE SERIALIZED EQUIPMENT 4. ALL AVAILABLE JURISDICTIONAL PERMIT AND OCCUPANCY INFORMATION 5. PDF SCAN OF REDUNES PRODUCED IN FIELD B. A PDF SCAN OF REDUNE MARK—UPS SUITABLE FOR USE IN ELECTRONIC AS —BUILT DRAWING PRODUCTION 7. LIEN WAVERS 8. FINAL PAYMENT APPLICATION 9. REQUIRED FINAL CONSTRUCTION PHOTOS 10. CONSTRUCTION AND COMMISSIONING CHECKLIST COMPLETE WITH NO DEFICIENT ITEMS 11. APPLICABLE POST NTP TASKS INCLUDING DOCUMENT UPLOADS COMPLETED IN SIERRA (SPRINTS DOCUMENT REPOSITORY OF RECORD). 12. CLOSEOUT PHOTOGRAPHS AND CLOSEOUT CHECKLIST: SPRINT WILL PROVIDE SEPARATE GUIDANCE SUMMARY: THIS SECTION SPECIFIES INSTALLATION OF ANTENNAS, RRU'S, AND CABLE EQUIPMENT, INSTALLATION, AND TESTING OF COAXIAL FIBER CABLE THE NUMBER AND TYPE OF ANTENNAS AND RRU'S TO BE INSTALLED IS DETAILED ON THE CONSTRUCTION DRAWINGS. HYBRID CABLE: HYBRID CABLE WILL BE DC/FIBER AND FURNISHED FOR INSTALLATION AT EACH STE. CABLE SHALL BE INSTALLED PER THE CONSTRUCTION DRAWINGS AND THE APPLICABLE MANUFACTURER'S REQUIREMENTS. JUMPERS AND CONNECTORS: FURNISH AND INSTALL 1/2- COAX JUMPER CABLES BETWEEN THE RRU'S AND ANTENNAS. JUMPERS SHALL BE TYPE LDF 4, FLC 12-50, CR 540. OR FXL 540. SUPER —FLEX CABLES ARE NOT ACCEPTABLE JUMPERS BETWEEN THE RRU'S AND ANTENNAS OR TOWER TOP AMPLIFIERS SHALL CONSIST OF 1/2 INCH FOAM DIELECTRIC, OUTDOOR RATED COAXIAL CABLE, MIN LENGTH FOR JUMPER SHALL BE SO AS TO ALLOW FOR PROPER BEND RADIUS PER MANUFACTURER OR SPRINTS SPECIFICATIONS. REMOTE ELECTRICAL TILT (REr) CABLES - MISCELLANEOUS, INSTALL SPUTTERS, COMBINERS, FILTERS PER RF DATA SHEET, FURNISHED BY SPRINT. ANTENNA INSTALLATION: THE CONTRACTOR SHALL ASSEMBLE ALL ANTENNAS ONSFE IN ACCORDANCE WITH THE INSTRUCTIONS SUPPLIED BY THE MANUFACTURER. ANTENNA HEIGHT, AZIMUTH, AND FEED ORIENTATION INFORMATION SHALL BE A DESIGNATED ON THE CONSTRUCTION DRAWINGS. A. THE CONTRACTOR SHALL POSITION THE ANTENNA ON TOWER PIPE MOUNTS SO THAT THE BOTTOM STRUT IS LEVEL THE PIPE MOUNTS SHALL BE PLUMB TO WITHIN 1 DEGREE. B. ANTENNA MOUNTING REQUIREMENTS: PROVIDE ANTENNA MOUNTING HARDWARE AS INDICATED ON THE DRAWINGS. HYBRID CABLE INSTALLATION: A THE CONTRACTOR SHALL ROUTE, TEST, AND INSTALL ALL CABLES AS INDICATED ON THE CONSTRUCTION DRAWINGS AND IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. B. THE INSTALLED RADIUS OF THE CABLES SHALL NOT BE LESS THAN THE MANUFACTURER'S SPECIFICATIONS FOR BENDING RADII. C. EXTREME CARE SHALL BE TAKEN TO AVOID DAMAGE TO THE CABLES DURING HANDLING AND INSTALLATION. 1. FASTENING MAIN HYBRID CABLE: ALL CABLES SHALL BE INSTALLED INSIDE MONOPOLE WITH CABLE SUPPORT GRIPS AS REQUIRED BY THE MANUFACTURER. 2. FASTENING INDIVIDUAL FIBER AND DC CABLES ABOVE BREAKOUT ENCLOSURE (MEDUSA), WITHIN THE MMBS CABINET AND ANY INTERMEDIATE DISTRIBUTION BOXES: a. FIBER: SUPPORT FIBER BUNDLES USING 1/2• VELCRO STRAPS OF THE REQUIRED LENGTH ® 18- OC. STRAPS SHALL BE W. OIL AND WATER RESISTANT AND SUITABLE FOR INDUSTRIAL INSTALLATIONS AS MANUFACTURED BY TEXTOL OR APPROVED EQUAL b. DC: SUPPORT DC BUNDLES WITH ZIP TIES OF THE ADEQUATE LENGTH. ZIP TIES TO BE W STABILIZED, BLACK NYLON, WITH TENSILE STRENGTH AT 12,000 PSI AS MANUFACTURED BY NELCO PRODUCTS OR EQUAL 3. FASTENING JUMPERS: SECURE JUMPERS TO THE SIDE ARMS OR HEAD FRAMES USING STAINLESS STEEL TIE WRAPS OR STAINLESS STEEL BUTTERFLY CLIPS. 4. CABLE INSTALLATION: a. INSPECT CABLE PRIOR TO USE FOR SHIPPING DAMAGE, NOTIFY THE CONSTRUCTION MANAGER. b. CABLE ROUTING: CABLE INSTALLATION SHALL BE PLANNED TO ENSURE THAT THE LINES WILL BE PROPERLY ROUTED IN THE CABLE ENVELOP AS INDICATED ON THE DRAWINGS. AVOID TWISTING AND CROSSOVERS. G. HOIST CABLE USING PROPER HOISTING GRIPS. DO NOT EXCEED MANUFACTURES RECOMMENDED MAXIMUM BEND RADIUS. REV DATE DESCRIPTION A 3/31/14 PRELIMINARY 0 6/2/14 FOR PERMIT CTNO.: 14 905.02 V RAWN BY: CHECKED BY: . ACOSTA M. ABBEY THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF THE OWNER. IT IS PRODUCED SOLELY FOR USE BY THE OWNER AND ITS AFFILIATES. REPRODUCTION OR USE OF THIS DRAWING AND/OR THE INFORMATION CONTAINED IN R IS FORBIDDEN WITHOUT THE WRITTEN PERMISSION OF THE OWNER Telecom .ADO LAKESIDE DRIVE SUITE 525 uIR . R 33027 CERTIFM E OF AIITHORIZATON 29214 Sprint' 6391 SPRINT PARKWAY OVERLAND PARK, KS 66251 (913) 315-8081 .h No. 683 •••'0 :N :C :W • S TE OF • �_�, A P:% ��i AS •• O Rio • U' ,%% OVAL DATE OF IGNATURE: 11/14/16 160XC244-A MIDWAY SHEET NAME SPRINT SPECIFICATIONS (SPRINT SPECIFICATIONS Ii l T2 CONTINUE FROM T2 5. GROUNDING OF TRANSMISSION LINES: ALL TRANSMISSION LINES SHALL BE GROUNDED AS INDICATED ON DRAWINGS. 6. HYBRID CABLE COLOR CODING: ALL COLOR CODING SHALL BE AS REQUIRED IN TS 0200 REV 4. 7. HYBRID CABLE LABELING: INDIVIDUAL HYBRID AND DC BUNDLES SHALL BE LABELED ALPHA -NUMERICALLY ACCORDING TO SPRINT CELL SITE ENGINEERING NOTICE - EN 2012-001. REV 1 A ALL FIBER & COAX CONNECTORS AND GROUND KITS SHALL BE WEATHERPROOFED. B. WEATHERPROOFED USING ONE OF THE FOLLOWING METHODS. ALL INSTALLATIONS MUST BE DONE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND INDUSTRY BEST PRACTICES. 1. COLD SHRINK: ENCOMPASS CONNECTOR IN COLD SHRINK TUBING AND PROVIDE A DOUBLE WRAP OF 2' ELECTRICAL TAPE EXTENDING 2' BEYOND TUBING. PROVIDE 3M COLD SHRINK CXS SERIES OR EQUAL 2. SELF -AMALGAMATING TAPE CLEAN SURFACES. APPLY A DOUBLE WRAP OF SELF -AMALGAMATING TAPE 2' BEYOND CONNECTOR. APPLY A SECOND WRAP OF SELF -AMALGAMATING TAPE IN OPPOSITE DIRECTION. APPLY DOUBLE WRAP OF 2' WIDE ELECTRICAL TAPE EXTENDING 2' BEYOND THE SELF -AMALGAMATING TAPE. 3. 3M SUM LOCK CLOSURE 716; SUBSTITUTIONS WILL NOT BE ALLOWED. 4. OPEN FLAME ON JOB SITE IS NOT ACCEPTARL SUMMARY: A. THIS SECTION SPECIFIES MMBS CABINETS, POWER CABINETS, AND INTERNAL EQUIPMENT INCLUDING BY NOT LIMITED TO RECTIFIERS, POWER DISTRIBUTION UNITS, BASE BAND UNITS, SURGE ARRESTORS, BATTERIES, AND SIMILAR EQUIPMENT FURNISHED BY THE COMPANY FOR INSTALLATION BY THE CONTRACTOR (OFCI). B. CONTRACTOR SHALL PROVIDE AND INSTALL ALL MISCELLANEOUS MATERIALS AND PROVIDE ALL LABOR REQUIRED FOR INSTALLATION EQUIPMENT IN EXISTING CABINET OR NEW CABINET AS SHOWN ON DRAWINGS AND AS REQUIRE BY THE APPUCABLE INSTALLATION MOPS. C. COMPLY WITH MANUFACTURERS INSTALLATION AND START-UP REQUIREMENTS DC CIRCUIT BREAKER LABELING A NEW DC CIRCUIT IS REQUIRED IN MMBS CABINET SHALL BE CLEARLY IDENTIFIED AS TO RRU BEING SERVICED SECTION 26 100 - BASIC ELECTRICAL REQUIREMENTS SUMMARY: THIS SECTION SPECIFIES BASIC ELECTRICAL REQUIREMENTS FOR SYSTEMS AND COMPONENTS. QUALITY ASSURANCE: A ALL EQUIPMENT FURNISHED UNDER DIVISION 26 SHALL CARRY UL LABELS AND LISTINGS WHERE SUCH LABELS AND USTINGS ARE AVAILABLE IN THE INDUSTRY. B. MANUFACTURERS OF EQUIPMENT SHALL HAVE A MINIMUM OF THREE YEARS EXPERIENCE WITH THEIR EQUIPMENT INSTALLED AND OPERATING IN THE FIELD IN A USE SIMILAR TO THE PROPOSED USE FOR THIS PROJECT. C. MATERIALS AND EQUIPMENT: ALL MATERIALS AND EQUIPMENT SPECIFIED IN DIVISION 26 OF THE SAME TYPE SHALL BE OF THE SAME MANUFACTURER AND SHALL BE NEW, OF THE BEST QUALITY AND DESIGN, AND FREE FROM DEFECTS SUPPORTING DEVICES: A ALL EQUIPMENT FURNISHED UNDER DIVISION 26 SHALL CARRY UL LABELS AND USTINGS WHERE SUCH LABELS AND LISTINGS ARE AVAILABLE IN THE INDUSTRY.- - - - B. MANUFACTURERS OF EQUIPMENT SHALL HAVE A MINIMUM OF THREE YEARS EXPERIENCE WITH THEIR EQUIPMENT INSTALLED AND OPERATING IN THE FIELD IN A USE SIMILAR TO THE PROPOSED USE FOR THIS PROJECT. C. MATERIALS AND FQUIPMFNTj ALL MATERIALS AND EQUIPMENT SPECIFIED IN DIVISION 26 OF THE SAME TYPE SHALL BE OF THE SAME MANUFACTURER AND SHALL BE NEW. OF THE BEST QUALITY AND DESIGN, AND FREE FROM DEFECTS SUPPORTING DEVICES: A MANUFACTURED STRUCTURAL SUPPORT MATERIALS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY THE FOLLOWING: 1. AWED TUBE AND CONDUIT 2. B-LINE SYSTEM 3. SUNISTRUT DIVERSIFIED PRODUCTS 4. THOMAS & BELTS B. FASTENERS: TYPES, MATERIALS, AND CONSTRUCTION FEATURES AS FOLLOWS: 1. EXPANSION ANCHORS: CARBON STEEL WEDGE OR SLEEVE TYPE 2. POWER -DRIVEN THREADED STUDS: HEAT -TREATED STEEL, DESIGNED SPECIFICALLY FOR THE INTENDED SERVICE. 3. FASTEN BY MEANS OF WOOD SCREWS ON WOOD. 4. TOGGLE BOLTS ON HOLLOW MASONRY UNITS. 5. CONCRETE INSERTS OR EXPANSION BOLTS ON CONCRETE OR SOLID MASONRY. 6. MACHINE SCREWS, WELDED THREADED STUDS, OR SPRING -TENSION CLAMPS ON STEEL 7. EXPLOSIVE DEVICES FOR ATTACHING HANGERS TO STRUCTURE SHALL NOT BE PERMITTED. 8. DO NOT WELD CONDUIT, PIPE STRAPS, OR ITEMS OTHER THAN THREADED STUDS TO STEEL STRUCTURES. 9. IN PARTITIONS OF LIGHT STEEL CONSTRUCTION, USE SHEET METAL SCREWS. SUPPORTING DEVICES: A INSTALL SUPPORTING DEVICES TO FASTEN ELECTRICAL COMPONENTS SECURELY AND PERMANENTLY IN ACCORDANCE WITH NEC. S. COORDINATE WITH THE BUILDING STRUCTURAL SYSTEM AND WITH OTHER TRADES. C. UNLESS OTHERWISE INDICATED ON THE DRAWINGS, FASTEN ELECTRICAL ITEMS AND THEIR SUPPORTING HARDWARE SECURELY TO THE STRUCTURE IN ACCORDANCE WITH THE FOLLOWING: D. ENSURE THAT THE LOAD APPLIED BY ANY FASTENER DOES NOT EXCEED 25 PERCENT OF THE PROOF TEST LOAD. E. USE VIBRATION AND SHOCK -RESISTANT FASTENERS FOR ATTACHMENTS TO CONCRETE SLABS. E. LIQUID TIGHT FLEXIBLE MEIAWC CONDUIT SHALL BE USED FOR FINAL CONNECTION TO EQUIPMENT. FITTINGS SHALL BE METALLIC GLAND TYPE COMPRESSION FITTINGS, MAINTAINING THE INTEGRITY OF CONDUIT SYSTEM. SET SCREW CONNECTIONS SHALL NOT BE ACCEPTABLE MAXIMUM LENGTH OF FLEXIBLE CONDUIT SHALL NOT EXCEED 6-FEET. LFMC SHALL BE PROTECTED AND SUPPORTED AS REQUIRE BY NEC. MANUFACTURERS OF FLEXIBLE CONDUITS SHALL BE CAROL, ANACONDA METAL HOSE OR UNIVERSAL METAL HOSE, OR APPROVED EQUAL F. MINIMUM SIZE CONDUIT SHALL BE 3/4 INCH (21MM). HUBS AND BOXES: A AT ENTRANCES TO CABINETS OR OTHER EQUIPMENT NOT HAVING INTEGRAL THREADED HUBS PROVIDE METALLIC THREADED HUBS OF THE SIZE AND CONFIGURATION REQUIRED. HUB SHALL INCLUDE LOCKNUT AND NEOPRENE 0-RING SEAL PROVIDE IMPACT RESISTANT 105 DEGREE C PLASTIC BUSHINGS TO PROTECT CABLE INSULATION. B. CABLE TERMINATION FITTINGS FOR CONDUIT 1. CABLE TERMINATORS FOR RGS CONDUITS SHALL BE TYPE CRC BY 0-Z/GEDNEY OR EQUAL BY ROX TEC. 2. CABLE TERMINATORS FOR LFMC SHALL BE ETCO - CL2075; OR MADE FOR THE PURPOSE PRODUCTS BY ROXTEC. C. EXTERIOR PULL BOXES AND PULL BOXES IN INTERIOR INDUSTRIAL AREAS SHALL BE PLATED CAST ALLOY, HEAVY DUTY, WEATHERPROOF, DUST PROOF, WITH GASKET, PLATED IRON ALLOY COVER AND STAINLESS STEEL COVER SCREWS, CROUSE-HINDS WAB SERIES OR EQUAL D. CONDUIT OUTLET BODIES SHALL BE PLATED CAST ALLOY WITH SIMILAR GASKETED COVERS. OUTLET BODIES SHALL BE OF THE CONFIGURATION AND SIZE SUITABLE FOR THE APPLICATION. PROVIDE CROUSE-HINDS FORM 8 OR EQUAL E. MANUFACTURER FOR BOXES AND COVERS SHALL BE HOFFMAN, SQUARE V. CROUSE-HINDS, COOPER, ADALET, APPLETON, O-Z GEDNEY, RACO, OR APPROVED EQUAL SUPPLEMENTAL GROUNDING SYSTEM A FURNISH AND INSTALL A SUPPLEMENTAL GROUNDING SYSTEM TO THE EXTENT INDICATED ON THE DRAWINGS. SUPPORT SYSTEM WITH NON-MAGNETIC STAINLESS STEEL CUPS WITH RUBBER GROMMETS. GROUNDING CONNECTORS SHALL BE TINNED COPPER WIRE, SIZES AS INDICATED ON THE DRAWINGS. PROVIDE STRANDED OR SOLID BARE OR INSULATED CONDUCTORS EXCEPTED AS OTHERWISE NOTED. B. SUPPLEMENTAL GROUNDING SYSTEM: ALL CONNECTIONS TO BE MADE WITH CAD WELDS, EXCEPT AT EQUIPMENT USE LUGS OR OTHER AVAILABLE GROUNDING MEANS AS REQUIRED BY MANUFACTURER; AT GROUND BARS USE TWO HOLE SPADES WITH NO OX. C. STOLEN GROUND -BARS: IN THE EVENT OF STOLEN GROUND BARS, CONTACT SPRINT CM FOR REPLACEMENT INSTRUCTION USING THREADED ROD KITS. (REV I DATE I DESCRIPTION 1 I PROJECT NO.: 140-905.021 J. ACOSTA I M. ABBEY THIS DRAWING IS COPYRIGFTIED AND IS THE SOLE PROPERTY OF THE OWNER. IT IS PRODUCED SOLELY FOR USE BY THE OWNER AND IS AFFILIATES. REPRODUCTION OR USE OF THIS DRAWING AND/OR THE INFORMAIION CONTAINED W IT IS FORBIDDEN WIDIOUT NE WROTEN PERMISSION OF THE OWNER Telecom 3400 W MIDE DRIVE SUITE 525 MNAWR, R 33027 CMFTFl E OF AUTHORRAMIN 29214 Sprint* 6391 SPRINT PARKWAY OVERLAND PARK, KS 56251 (913) 315-8081 ELECTRICAL IDENTIFICATION: EXISTING STRUCTURE - A. BREAKERUPDATE AND PROVIDE TYPED CIRCUIT SCHEDULES IN THE INSIDE DOORS 0 AC PANNEL BOAR S WITH ANY CHANGES MAD TO THE ACNGM. A EXISTING EXPOSED WIRING AND ALL EXPOSED OUTLETS, RECEPTACLES, SWITCHES, ����, V "• JP DEVICES, BOXES, AND OTHER EQUIPMENT THAT ARE NOT TO BE UTIUZED IN THE �� �:•••(, E N•• B. BRANCH CIRCUITS FEEDING AVIATION OBSTRUCTION LIGHTING EQUIPMENT SHALL BE COMPLETED PROJECT SHALL BE REMOVED OR DE -ENERGIZED AND CAPPED IN THE `��`• •••VA `S CLEARLY IDENTIFIED AS SUCH AT THE BRANCH CIRCUIT PANELBOARD. WALL, CEILING, OR FLOOR SO THAT THEY ARE CONCEALED AND SAFE. WALL, CEILING, OR FLOOR SHALL BE PATCHED TO MATCH THE ADJACENT CONSTRUCTION. No. 68312 SECTION 26 200 - ELECTRICAL MATERIALS AND EQUIPMENT CONDUIT: A. RIGID GALVANIZED STEEL (RGS) CONDUIT SHALL BE USED FOR EXTERIOR LOCATIONS ABOVE GROUND AND IN UNFINISHED INTERIOR LOCATIONS AND FOR ENCASED RUNS IN CONCRETE. RIGID CONDUIT AND FITTINGS SHALL BE STEEL. COATED WITH ZINC EXTERIOR AND INTERIOR BY THE HOT DIP GALVANIZING PROCESS. CONDUIT SHALL BE PRODUCED TO ANSI SPECIFICATIONS C80.1, FEDERAL SPECIFlCA11ON WW-C-581 AND SHALL BE LISTED WITH THE UNDERWRITERS' LABORATORIES. FITTINGS SHALL BE THREADED - SET SCREW OR COMPRESSION FDTINGS WILL NOT BE ACCEPTABLE RGS CONDUITS SHALL BE MANUFACTURED BY AWED, REPUBLIC OR WHEATLAND. B. UNDERGROUND CONDUIT IN CONCRETE SHALL BE POLYVINYLCHLORIDE (PVC) SUITABLE FOR DIRECT BURIAL AS APPLICABLE JOINTS SHALL BE BELLED, AND FLUSH SOLVENT WELDED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. CONDUIT SHALL BE CARLON ELECTRICAL PRODUCTS OR APPROVED EQUAL C. TRANSITIONS BETWEEN PVC.AND RIGID (RGS) SHALL BE MADE WITH PVC COATED METALLIC LONG SWEEP RADIUS ELBOWS. _ D. EMT OR RIGID GALVANIZED STEEL CONDUIT MAY BE USED IN FINISHED SPACES CONCEALED IN WALLS AND CEIUNS. EMI SHALL BE MILD STEEL, ELECTRICALLY WELDED, ELECTRO-GALVANIZED OR HOT -DIPPED GALVANIZED AND PRODUCED TO ANSI SPECIFICATION C80.3, FEDERAL SPECIFICATION WW-C-563, AND SHALL BE UL LISTED. EMT SHALL BE MANUFACTURED BY AWED, REPUBUC OR WHEATAND, OR APPROVED EQUAL FITTINGS SHALL BE METALLIC COMPRESSION. SET SCREW CONNECTIONS SHALL NOT BE ACCEPTABLE CONDUIT AND CONDUCTOR INSTALLATION: A CONDUITS SHALL BE FASTENED SECURELY IN PLACE WITH APPROVED NON -PERFORATED STRAPS AND HANGERS. EXPLOSIVE DEVICES FOR ATTACHING HANGERS TO STRUCTURE WILL NOT BE PERMITTED. CLOSELY FOLLOW THE LINES OF THE STRUCTURE, MAINTAIN CLOSE PROXIMITY TO THE STRUCTURE AND KEEP CONDUITS IN TIGHT ENVELOPES. CHANGES IN DIRECTION TO ROUTE AROUND OBSTACLES SHALL BE MADE WITH CONDUIT OUTLET BODIES. CONDUIT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER, PARALLEL AND PERPENDICULAR TO STRUCTURE WALL AND CEILING UNES. ALL CONDUIT SHALL BE FISHED TO CLEAR OBSTRUCTIONS. ENDS OF CONDUITS SHALL BE TEMPORARILY CAPPED TO PREVENT CONCRETE, PLASTER OR DIRT FROM ENTERING. CONDUITS SHALL BE RIGIDLY CLAMPED TO BOXES BY GALVANIZED MALLEABLE IRON BUSHING ON INSIDE AND GALVANIZED MALLEABLE IRON LOCKNUT ON OUTSIDE AND INSIDE. B. CONDUCTORS SHALL BE PULLED IN ACCORDANCE WITH ACCEPTED GOOD PRACTICE k R1 AL DATE OF SIGNATURE: 11/14/16 M160XC244-A MIDWAY TOWER ROAD 349U SPRINT SPECIFICATIONS SHEET NUMBER SPRINT SPECIFICATIONS T3 REV DATE DESCRIPTION A D/2/1 4 PREFOR PERMIT MINARY 0 6/2/14 FOR PERMIT PROJECT NO-- 140-205.02 DRAWN BY: CHECKED BY: J. ACOSTA M. ABBEY THIS DRAWING IS COPYRIGHTED AND IS ME SOLE PROPERTY OF THE OWNER IT IS PRODUCED SOLELY FOR USE EY THE OWNER LATES REPRODUCTION OR O USE OFTHISS DRAWING AND/OR ME INFORMATION CONTAINED IN '0 IT IS FORBIDDEN WITHOUT THE WRITTEN n 5. fop PERMISSION OF THE OWNER A2� Re w� TTO 4y wp PROPOSED SPRINT Telecom u 2.SGFtr fiRU (lYP OF 3) 3409 IAKE9mE DarvE tl" (SEE NOTE 1) 3 MIZI ,Vfa pR525 / CER➢FlG1TE OF AUIHCRIIATION 29214 1 ;a B e E 770• 1� E EV. PROPOSED FIBER T50't ELEV. JUMPER 50 (SEE NOTE 'lop EXISTING SPRINT TOCDM.%&' PROPOSED SPRINT 5 p r I n t m Mom, BE RELOCATED 2.5GHz ANTENNA /�y�OF 8) f A.. r. K'�,.r, CM. OF 3) 1 8391 SPRINT PARKWAY C4 OVERLAND PARK. KS 66251 (913) 315-8 0B1 D(ISTING SPRINT ANTENNA MOUNT (TYP. OF 3) �` 1j pppMMMAAA///LLL ` : 0♦ G SPRINT p�TEELOC TED � PROPOSED SPRINT N UNIT lD""�'E RELOCATED (ATTACHED TO MOUNT U� No. 6B :N (TYP. OF 3) �4^b WO STAINUSS STEEL Tm SPRINT C' ti° 'V HOSE CLAMPS) n, . CyO�MA/LTE tD1U : 1y yy� (lYP. OF 6) ST F 41 /Cl RELOCATED SPRINT '♦.,Sj'••• R � ••.�COW/L7E ANTENNA ��q NAL* OF 3) DATE OF SI TURE 11/14/1s M160XC244-A MIDWAY NOTES, 62'1 AIL CAPY- 1. ALL RRU'S MUST BE ELECTRICALLY POWERED WITHIN 24 HOURS OF BEING REMOVED FROM THE MANUFACTURER'S PACKAGING. SHEET NAME 2. CONTRACTOR SHALL DETERMINATE EXACT ROUTING IN FIELD. ANTENNA 3. THIS DRAWING IS INTENDED TO DEPICT THE GENERAL LOCATION AND HEIGHT OF THE PROPOSED ANTENNAS ON THE EXISTING ANTENNA LAYOUTS MOUNTING SYSTEM. CONSTRUCTION SHALL NOT PROCEED UNTIL A STRUCTURAL ANALYSIS REPORT HAS BEEN COMPLETED BY A PROFESSIONAL ENGINEER REGISTERED IN THIS STATE, CONCLUDING THAT THE EXISTING ANTENNA MOUNTING SYSTEM IS STRUCTURALLY SHEET NUMBER ADEQUATE TO RESIST THE EXISTING AND PROPOSED LOADS. EXISTING ANTENNA LAYOUT NTS 1 IPROPOSED ANTENNA LAYOUT NTs 12., C3 9 (03sn ION) S (a3Sf1 ION) -V I sw �IV134 ISVW VNN3INV UM Had Z j0 'dW n09—n ox a3sodoNd ('du) 3NVaW wnow VNN3INV ONOSI%3 (HQLDM Had � d0 'dW 0 M .0—.9 'IM ONIWnON —MUM -0.0 .99 0MU(Md 2 sw �MDG 0NI1Nfl0W flab ZHOS'Z Z (43sn ION) l JsLN -lIV134 0NI1Nnm VNN3INV 'ONIOMIOVd S,?13iln1OV3nNVW 3HL HOW 03AOVN38 ONI39 d0 SVOH bZ WWM 030MOd kimi j.65b m Ism s,naa rro VNK WV /M 030VONd e'0'0 . 03SOONd 13)IOWS VNN3WV 03SOdOHd q0p b i p IIhgg i � iM VNN3INV �'0'0 .99 MUM �Mm fl 1NMd5 03SOdONd Ir, ,� I�! ' SO VNN3LNV ZH07Z a i+ pt MHdS 03S0d0Vd • :non AN 13mm ('dW VNN3WV3dld • /M ci3avmd S13 om • ONONnOn 3dld 03SOdONd VNN3INV /M 03Orim 13MOVN9 nLL VNN3WV 03SOdONd REV DATE DESCRIPTION A 3/31/14 PREUMINARY �12•�-i 0 6/2/14 FOR PERMIT PROJECT NO.: 140-905.02 DRAWN BY: CHECKED BY: J. ACOSTA M. ABBEY ••.1 THIS DRAWING 0 COPYRIGHTED AND IS THE SOLE PROPERTY OF THE OMER. IT e 5 PRODUCED SOLELY FORAFFILIATES. USE THE OWNER ANDOR S THISD < REPRODUCTION FO USE OF THIS DRAWING ri AND/OR THE INFORMATION THE WRITTEN IN R IS FORBIDDEN OFTHWITHOUT THE WRIREN PERMISSION OF THE OWNER- 1�8.7------ F- 17.4• -I Telecom o SHIO IAKESIOE DRIVE 525 F-12.0•—� PLAN VIEW FRONT VIEW SCR, 33027 CERPFIGTE CF AI ORI}ATION 29214 PLAN VIEW FRONT VIEW MODEL- 55.4 LBS TTTf65AP-1XR MODEL: N5. RRU FLHJ \`� WEIGHT: 55.4 LBS WEIGHT. 55.2 LBS V1 ANTENNA SPECS HTs 1 (NOT USED) 2 2.5GHz RRU SPECS NT5 3 Sprint* 6391 SPRINT PARKWAY OVERIAND PARK. KS 65251 (913) 315-8031 OEM i No. 6831 Q: :W O� 5T T OF .A QP: ♦♦♦♦ ��I AS• O R I• • � •�0 ♦♦ ��o� DNA L � ♦♦• DATE OF IGNATURE: 11/14/16 160XC244-A MIDWAY — - �� R MI AY ROAD PIERC FL 34902 SHEET NAME DETAILS SHEET NUMBER (NOT USED) 14 (NOT USED) 5 (NOT USED) 6 C5 REV DATE DESCRIPTION A 3/2/14 FORPRE PERMIT ARY EXISTING TOWER 0 6/2/14 FOR PERMR GROUND BAR (TBGB) (REMOVE ISOLATORS IF • ' THEY EXIST) (SEE NOTE 1) / PROPOSED HYBRID D KIT PER I PROPOSED SPRINT 2.5GHZ ANTENNA MANUFACTURER'S (TYP.) SPECIFICATIONS (TYP. PROJECT NO.: 140-905.02 (SEE NOTE 2; DwTwN er: CHECKED ar: PROPOSED J. ACOSTA M. ABBEY ANTENNA MAST PROPOSED SPRINT ` THIS DRAWING IS COPYRIGHTED AND IS HYBRID CABLE / THE SOLE PROPERTY OF THE OWNER R I (SEE NOTES) I IS PRODUCED SOLELY FOR USE BY THE OWNER AND ITS AFFILIATES. REPRODUCTION OR USE OF THIS DRAWING I AND/OR THE INFORMATION CONTAINED IN IT IS FORBID DEN WITHOUT THE WRITTEN i PERMISSION OF THE OWNER. EXISTING MASTER GROUND BAR (MGB) • I "• (SEE NOTE 1)Mm I Telecom °ti��lll�l 3400 uIE IDE52 DRIVE SORE 525 MIRAINR FL 3302T I ��I .ITIT I�1 II �I III Al CERTIRGITE OF AUTHORIZATION 2921a EXISTING SECTOR i GROUND BAR (REMOVE ISOLATORS IF THEY EXIST) NDIEi: (TYP) 1. PROVIDE GROUND CONNECTION FOR HYBRID CABLES TO TOWER BOTTOM GROUND BAR (TBGB) AND r� PROPOSED 6 AWG GREEN jyQg: It STRANDED 1t STRANDED COPPER CONDUCTOR MASTER GROUND BAR (MGB). PROVIDE GROUND CONNECTION FOR HYBRID ') 2. DEPICTION OF GROUND KR ROUTING IS IS GABLES TO TOWER BOTTOM GROUND BAR DIAGRAMMATIC, CONTRACTOR SHALL ENSURE THAT (TBGB) AND MASTER GROUND BAR (MGB). RRO� 15CHz ALL INSTALLED GROUNDING DOES NOT CREATE A (TYP.) "REVERSE GROUNDING' CONDITION. 6391 SPRINT PARKWAY OVERUNO PARK, KS 66251 GROUNDING DIAGRAM (TYP.) NTS1 1 GROUNDING PLAN NTS 2 (913) 315-8031 1. RECORD DRAWINGS: MAINTAIN A RECORD OF ALL CHANGES, SUBSTITUTIONS BETWEEN WORK AS SPECIFIED AND INSTALLED. RECORD CHANGES ON A CLEAN SET OF CONTRACT DOCUMENTS ,��% A; .pE%ii WHICH SHALL BE NRNED OVER TO THE CONSTRUCTION MANAGER UPON COMPLETION OF THE � p `G E IV S ••• �, PROJECT. ,� `r �C• I �i 2. GUARANTEE/WARRANTY: GUARANTEE INSTALLATION TO BE FREE OF DEFECTS, SHORTS, GROUNDS, No. 6831 ••• 4 EXISTING GROUND ETC., FOR A PERIOD OF ONE YEAR. FURNISH WARRANTY SO THE DEFECTIVE MATERIAL ANO/OR BAR COPPER CONDUCTOR (TYP.) WORKMANSHIP WILL BE REPAIRED/REPLACED IMMEDIATELY UPON NOTIFICATION AT NO COST TO THE OWNER FOR PERIOD OF WARRANTY. : O: 3. ALL TIE WRAPS SHALL BE CUT FLUSH WITH APPROVED CUTTING TOOL TO REMOVE SHARP EDGES. ST IF •• CTRICAL MErALUC BING (EMT) OR CON UIT (I.E., RIGID PVC WASHER 4 SCHEDULE 40. OR RIGID NPVC SCHEDULE 80 RIGID LOCATIONSUBJ CTDTO PHYSICAL DAMAGE) �i�sS/� ® SHALL BE USED FOR EXPOSED INDOOR LOCATIONS. ��I� NAL• O` 0 0 0 %•x1y4" SS BOLT ®0000 0 5. LIQUID -TIGHT FLEXIBLE METAWC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED INDOORS AND DATE OF SI NRE. 11/74/16 00®®0 00® ®� OUTDOORS, WHERE VIBRATION OCCURS OR FLEXIBIUTY IS NEEDED. 0000 ° S. WIREWAYS SHALL BE EPDXY -COATED (GRAY) AND INCLUDE A HINGED COVER, DESIGNED TO Ivy 6OXC244-A / BETTER) INDOORS, SWING OPEN NWARD; SHALL BE PANDUIT TYPE E OR EQUAL); AND RATED NEMA 1 (OR OR NEMA 3R (OR BETTER) OUTDOORS. MIDWAY i 0 7. EQUIPMENT CABINETS TERMINAL BOXES, JUNCTION BOXES AND PULL BOXES SHALL BEFILE TER �• WASHER GALVANIZED OR EPDXY -COATED SHEET STEEL, SHALL MEET OR EXCEED UL 50, AND RATED NEMA 1 (OR BETTER) INDOORS, OR NEMA 3R (OR BETTER) OUTDOORS. E MAY ROAD SS LOCK WASHER 8. METAL RECEPTACLE, SWITCH, AND DEVICE BOXES SHALL BE GALVANIZED, EPDXY -COATED, OR P PI FL 34982 36• SS NUT NON -CORRODING; SHALL MEET OR EXCEED UL 514A AND NEMA OS 1; AND RATED NEMA 1 SHEET NAME (OR BETTER) INDOORS, OR WEATHER PROTECTED (WP OR BETTER) OUTDOORS. GROUNDING 9. NONMETAWC RECEPTACLE, SWITCH, AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2; AND RATED NEMA 1 (OR BETTER) INDOORS, OR WEATHER PROTECTED (WP OR BETTER) DETAILS AND NOTES OUTDOORS. SHEET NUMBER TYPICAL GROUND BAR CONNECTION DETAIL NTs 3 GROUNDING NOTES 4 E1