Loading...
HomeMy WebLinkAboutDESIGN CERTIFICATION FOR WIND LOAD COMPLIANCE:In St. Lucie County PUBLIC WORKS DEPARTMENT CODE COMPLIANCE DIVISION 2300 Virginia Avenue Fort Pierce, FL 34982 772.462.1553 Design Certification for Wind Load Compliance BY This Certification F1tst UG!Q 9JVhe project design architect or engineer. This Certification must be submitted in duplicate with all applications for building permits involving the construction of new residence (single or multi- family), residential addition, any accessory structure requiring a building permit, and any nonresidential structure. This Certification shall not apply to interior renovations (provided that no exterior structural walls, columns or other components are being affected) and certain other minor building permits. For further assistance, please contact the Building Inspection Office at (772)462-2172. Project Name oceenHaiborconao �OfficeiUs�Onl� Street Address 5269 FLA1A Permit Number FORT PIERCE, FLORIDA OccupancyT e Construction Type Certification Statement: I certify that, to the best of my knowledge and belief, these plans and specifications have been designed to comply with the applicable structural portion of the Building Codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the wind loads and forces specified by current code provisions. Design Parameters and Assumptions Used: (Please check or complete the appropriate box.) 1 Florida Building Code 2014 Edition with 2010 Supplements and ASCE 7 -10 2. Building Design is: Enclosed: Partially Enclosed: Open Building: X 3. Mean Roof Height: N/A Roof Pitch: N/A Internal Pressure Coefficient: N/A 4. Width of End Zone: Wind Speed: 165 (3 sec gust) 5. Building Classification Table �ASCE 710 EEC Table 1604.5 1 6. Wind Exposure Classificatior� Adjustment Factor for Exposure & Height: 1.21 7. Components & Cladding Wind Pressure on Roof Zone 1 N/A 2 N/A 3 N/A PSF 8. Components & Cladding Wind Pressure on Wall Zone 4 sost-sa.t STD.v-T4.5 PSF 9. Components & Cladding wind Pressure on Overhead Garage Door N/A PSF 10. Loads: Floor 40 PSF Roof/dead N/A PSF Roof/live N/A PSF 11. Shear Walls Considered for Structure? Yes X No (if No, attach explanation) 12. Continuous Load Path provided? Yes X No _ (if No, attach explanation) 13. Are Component and Cladding Details Provided? Yes X No _ (if No, attach explanation) 14. Minimum Soil Bearing Pressure: N/A Presumptive: By Test: PSF As witnessed by my seal, I hereby certify that the information included with this certification is true and correct, to the best of my knowledge and belief. Name: BOWDOIN G. HUTCHINSON p01H G. Design Firm: BENCHMARK ENGINEERING Tl� �0:'ii]101k7t sU�pg%T ' 2 l tP SLCCDV Form # 020.00 Revised 5/18/09 (CL) r-. St. Lucie County PUBLIC WORKS DEPARTMENT CODE COMPLIANCE DIVISION 8CA1VIVE6 2300 Virginia Avenue By Pierce, FL 34982 772-462-1553 St Lucie Count, Design Certification for Wind Load Compliance This Certification must be completed by the project design architect or engineer. This Certification must be submitted in duplicate with all applications for building permits involving the construction of new residence (single or multi- family), residential addition, any accessory structure requiring a building permit, and any nonresidential structure. This Certification shall not apply to interior renovations (provided that no exterior structural walls, columns or other components are being affected) and certain other minor building permits. For further assistance, please contact the Building Inspection Office at (772)462-2172. Project Name Owm H.i ,Condo �Offic'e1UsZOn1� Street Address 5269 FLAIR I Permit Number FORT PIERCE, FLORIDA Occupancy e Construction Type Certification Statement: I certify that, to the best of my knowledge and belief, these plans and specifications have been designed to comply with the applicable structural portion of the Building Codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the wind loads and forces specified by current code provisions. Design Parameters and Assumptions Used: (Please check or complete the appropriate box.) 1 Florida Building Code 2014 Edition with 2010 Supplements and ASCE 7 -10 2. Building Design is: Enclosed: Partially Enclosed: Open Building: X 3. Mean Roof Height: N/A Roof Pitch: NIA Internal Pressure Coefficient: N/A 4. Width of End Zone:1 Wind Speed:165 (3 sec. gust) 5. Building Classification TableE 710 FBC Table 1604.5 1 6. Wind Exposure Classscatio Adjustment Factor for Exposure & Height: 1.21 7. Components & Cladding Wind Pressure on Roof Zone 1 N/A 2 N/A 3 N/A PSF 8. Components &Cladding Wind Pressure on Wall Zone 4 60.61-64.1 70.V-74.s 5 PSF 9. Components & Cladding wind Pressure on Overhead Garage Door N/A PSF 10. Loads: Floor40 PSF Roof/dead N/A PSF Roof/live N/A PSF �� .. �i) t explanation) 11. Shear Walls Considered for Structure? Yes X No _ (if No, attache "y"C'�T� � v� 12. Continuous Load Path provided? Yes X No _ (if No, attach explanation) Ej 13. Are Component and Cladding Details Provided? Yes X No _ (if No, attach explanation) i+ 14. Minimum Soil Bearing Pressure: N/A Presumptive: By Test: PSF As witnessed by my seal, I hereby certify that the information included with this certification is true and correct, to the best of my knowledge and belief. Name: BOWDOIN G. HUTCHINSON Cert P 74878 ,T�r�i i7 \\\\\COIN G. H� Design Firm: BENCHMARK ENGINEERING TC \�,4/4itTfp2Ee: •.rC. �� Og)N — 8 ,� Z — SLCCDV Form # 020.00 — M — SEAL Revised 5/18/09 (CL) 00 S A74�- =