HomeMy WebLinkAboutMISC EMAILArchitectonic Inc
November 6, 2017
Saint Lucie County Building Department
Attn: Roof Permit Plan Review
2300 Virginia Avenue
Ft. Pierce, FL 34982
RE: 5908 Sunset Blvd.
Saint Lucie County
Permit # SLC 1610-0350
To Whom It May Concern:
SGANNtb
By
St. Lucie Cnnnt,
RECEIVED
NOV 13 2017
Permitting Department
St. Lucie County, FL
Please be advised that qualified personnel of Architectonic, Inc. has performed an on -site inspection on
November 8, 2017 at the above referenced location and found the following work to be done, to the best
of our knowledge.
1. Roof Dry -In
We hereby certify that the roofing is in compliance with the 2014 Florida Building Code, 160 mph wind
Zone, exposure "B", risk category II.
806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com
Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1
JRE INC.
COOK & MET ,_ �RD ARCHITEC.i
806 Delaware Avenue, Fort Pierce, Florida 34950
PHONE (772) 460-7751 FAX (772) 460-4244
EMAIL cookmenard@yahoo.com
November 2, 2016 EPermitting
VED
2017
Saint Lucie County Building Department partment
Attn: Roof Permit Plan Review JI,BYtL_ nty, FL
2300 Virginia Avenue St. Lucie Cnilnt•
Ft. Pierce, FL 34982
Re: Roofing specification prepared for the St. Lucie County Building Dept. for the structure located at
5908 Sunset Blvd, Saint Lucie County, Florida
Manufacturer:
Profiles:
Code:
Wind Speed:
Exposure:
Mean Roof Height:
Pitch:
Required Design Pressure:
Maximum Uplift Pressure:
Roof Decking:
Base:
Ply Sheet:
Cap:
Johns Manville
Johns Manville Modified Bitumen Roof System FL# 1046-117
FBC 2014; Section R 905.10
160 MPH; Ultimate Design Wind Speeds
B
30' Maximum
'/a 112
Zonel: -42.1 Zone 2: -50.0 Zone3: -82.9
-45 PSF Zone 1, -64.5, Zone 2, -92.5 Zone 3
Min 19/32" plywood at max, 24" spans attached 6" o.c., 8d x2"ring shank nails
JM APP Base, PermaPly 28, Glasbase Plus or Ventsulation
Fasteners: Zone 1)12-inch o.c. in 4-inch lap and 18-inch o.c. in two, equally spaced,
staggered center rows, Zone 2) 12-inch o.c. in 4-inch lap and 12-inch o.c. in two, equally
spaced staggered center rows, Zone3) 8-inch o.c. in 4-inch lap and 8-inch o.c. in two,
equally spaced staggered center rows
APP-TA (Torch Applied)
The above approved, as per Florida Building Code Compliance acceptances, 2014 Florida Building Code, and the
Manufacturer's recommendations.
Respectfully Submitted,
Peter B. Cook
Cook & Menard Architecture, Inc.