HomeMy WebLinkAboutMISC EMAILArchitectonic Inc November 6, 2017 Saint Lucie County Building Department Attn: Roof Permit Plan Review 2300 Virginia Avenue Ft. Pierce, FL 34982 RE: 5908 Sunset Blvd. Saint Lucie County Permit # SLC 1610-0350 To Whom It May Concern: SGANNtb By St. Lucie Cnnnt, RECEIVED NOV 13 2017 Permitting Department St. Lucie County, FL Please be advised that qualified personnel of Architectonic, Inc. has performed an on -site inspection on November 8, 2017 at the above referenced location and found the following work to be done, to the best of our knowledge. 1. Roof Dry -In We hereby certify that the roofing is in compliance with the 2014 Florida Building Code, 160 mph wind Zone, exposure "B", risk category II. 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1 JRE INC. COOK & MET ,_ �RD ARCHITEC.i 806 Delaware Avenue, Fort Pierce, Florida 34950 PHONE (772) 460-7751 FAX (772) 460-4244 EMAIL cookmenard@yahoo.com November 2, 2016 EPermitting VED 2017 Saint Lucie County Building Department partment Attn: Roof Permit Plan Review JI,BYtL_ nty, FL 2300 Virginia Avenue St. Lucie Cnilnt• Ft. Pierce, FL 34982 Re: Roofing specification prepared for the St. Lucie County Building Dept. for the structure located at 5908 Sunset Blvd, Saint Lucie County, Florida Manufacturer: Profiles: Code: Wind Speed: Exposure: Mean Roof Height: Pitch: Required Design Pressure: Maximum Uplift Pressure: Roof Decking: Base: Ply Sheet: Cap: Johns Manville Johns Manville Modified Bitumen Roof System FL# 1046-117 FBC 2014; Section R 905.10 160 MPH; Ultimate Design Wind Speeds B 30' Maximum '/a 112 Zonel: -42.1 Zone 2: -50.0 Zone3: -82.9 -45 PSF Zone 1, -64.5, Zone 2, -92.5 Zone 3 Min 19/32" plywood at max, 24" spans attached 6" o.c., 8d x2"ring shank nails JM APP Base, PermaPly 28, Glasbase Plus or Ventsulation Fasteners: Zone 1)12-inch o.c. in 4-inch lap and 18-inch o.c. in two, equally spaced, staggered center rows, Zone 2) 12-inch o.c. in 4-inch lap and 12-inch o.c. in two, equally spaced staggered center rows, Zone3) 8-inch o.c. in 4-inch lap and 8-inch o.c. in two, equally spaced staggered center rows APP-TA (Torch Applied) The above approved, as per Florida Building Code Compliance acceptances, 2014 Florida Building Code, and the Manufacturer's recommendations. Respectfully Submitted, Peter B. Cook Cook & Menard Architecture, Inc. Florida Registration No. AA0003494, NCARB Certification No. 31789