Loading...
HomeMy WebLinkAboutAPPLICATION LETTERA 2 AMERICAN TAWER-- C'6'RPOARATI'GR - November 11, 2016 Sprint Nextel Property Services Mailstop: KSOPHTO101 —Z2650 6391 Sprint Parkway Overland Park, KS 66251 - 2650 Attn: Real Estate Attorney; Sprint/Nextel Law Department SCANNEL) BY St. Lucie Counts Re: APPLICATION APPROVAL LETTER ATC Site Name / Number:M�dw_ayy Road / 5100 ATC Contract Number: SE00-241_`� Sprint/Nextel's Site ID• 1,1M XC0. 2 Schedule: License Agreement dateU March 5, 1997 (as amended, the "Schedule") Dear Customer: Capitalized terms used in this letter shall have the same meaning described for them in the Schedule unless otherwise indicated herein. Attached please find an approved application for Sprint's modification to its equipment at the above -referenced Tower Facility. The attached application and equipment exhibit, Exhibit D-3, shall memorialize, as of the date above, Sprint's equipment configuration and ground space at the Tower Facility and shall hereinafter be deemed "Licensee's Equipment" under the Schedule. Prior to the commencement of any construction activity, Sprint is required to request a Notice to Proceed from ATC. The parties agree that a scanned copy of this letter bearing the signature of ATC shall be deemed an original. Please do not hesitate to contact me with any questions in this regard. Very truly yours, DanieCBroe Daniel Broe Sr. Counsel, US Tower Enclosure: (1) •' 4 �L✓y �fP �• Y4�lY Exhibit D-3 Approved Auplication 4 Exhibit D-3 Customer Name: ATC Asset Name: ATC Asset #: SPRINTNEXTEL Midway Road 5100 Customer Site Name: Customer Site #: ATS - FT Pierce -Exit 64 M113XC052 GROUND SPACE REQUIREMENTS Total Lease Area Sq. Ft 170.00' Primary Contiguous Lease Area 1-:10DO' W:17.00' H: Sq. Ft: 170.00 Concrete Pad 10.00' 17.00' WA 170.00 Outside Primary Lease Area WA N/A N/A Sq. Ft: N/A BACKUP POWER REQUIREMENTS Generator. WA Capacity(KW): WA Fuel Tank Size(gal): WA Fuel Type: WA Fuel Tank Setback(redius): WA UTILITY REQUIREMENTS Power Provided By: Utility Company Direct Telconnterconnect Fiber Optics TRANSMF iffM B RECEIVER SPECIFICATIONS Type: WA Quantity: WA TX Power(watts): WA ERP(watts): WA ANTENNA EQUIPMENT SPECIFICATIONS Type PANEL PANEL RET/RCU RRUIRRH RRU/RRH RRU/RRH Manufacturer Mrg0e Qi@5' APrT emn 'aka grEritSson <EErm ills Model # LO44.1dR--W ABPAERfti9-C P`U:A20-N 19MIAiR aRRUSAV800,MHz RRFZ$.3. 1"B2_5 Dimensions HxWxD 46.1"x 11.8"x4.5" 72"x 11.8"x7" 4"x2"x3.5" 12.8"x9.7"x6.3" 17"x 17.8"x9.2" 16.5"x11.8"x9.3" Welght(lbs.) 26.5 50.0 1.0 26.5 54.0 56.1 Location Tower Tower Tower Tower Tower Tower RAD Center AGL 170.0' 170.0' 170.0' 170.0' 170.0' 170.0' Antenna Tip Height 171.9' 173.0' 170.2' 170.5' 170.7' 170.7' Antenna Base Height 168.1' 167.0' 169.8' 169.5' 169.3' 169.3' Mount Type Platform with Handrails Platform with Handrails Platform with Handrails Platform with Handrails Platform with Handrails Platform with Handrails Quantity gr;i7 qI> lrl or& 4�!f— Gx3Z5 Azimuths/Dir. of Radiation 3351110/210 34011001270 340/100/270 33511101210 34011001270 340/100/270 Quant Per Azimuthf5eclor 1/111 N/A WA 1/111 WA 1/1/1 DURX Frequency Units MHz MHz WA MHz N/A MHz TX Frequency 2496-2690 862A69,1950-1965, 1990-1995 WA 2496-2690 WA 2496 RX Frequency 2496-2690 817-824,187DA885, 1910-1915 WA 2496-2690 N/A 2496 Using Unlicensed Frequencies? Na No No No No No Antenna Gain 13.7114.4 11.9114.6114.6 WA WA 0 N/A Total # of Lines 1 3 0 1 0 0 Line Quant Per AzimuWSector 1/0/0 N/A WA 110/0 WA WA Line Type Coax Fiber/Hybdd N/A Conduit WA N/A Line Oiameter5ize 1.16"(29.5mm) SCOW 11/4" Hybdflex Cable WA 1"conduit WA N/A Line Con0guation WA N/A N/A 3 - CATS; 0.21" (5.3mm) Cat 5e 3 - Fiber/Hybdd; 0.87"(22.0mm) Fiber WA N/A OA48094P a r ::-