Loading...
HomeMy WebLinkAboutSTRUCTURAL EVALUATIONEng. Number OAA689477_C2_01 61LANNED November 3 2016 �} BY Page 1 of 2 AMERICAN Tavi6WCIe County CORPORATION 5t� - ural Eva uatio ' ATC Site Number & Name 5100, Midway Road, FL Carrier Site Number & Name MI33XC052, ATS - FT Pierce -Exit 64 Site Location 5690 Environment Drive Fort Pierce, FL 34981-4811, St Lucie County 27.37959167 N /-80.3821 W Tower Description 300 ft Self Supported Tower Basic Wind Speed Code 123 mph (3-Second Gust, Vad) / 159 mph (3-Second Gust, V.0 ANSI/TIA-222-G/ 20121BC/Sth Edition (2014) Florida Building Code Existing and Reserved Equipment Elevation' (ft) QtY 1. Antenna MountType Lines Carrier Mount RAD 293.0 293.0 4 CSS AXP18-80-2 Sector Frame (10) 15/8" Coax (2) 21/4" Coax Vedzon 2 CSSAXP19-60-2 3 CSS X7-665-4 262.0 262.0 6 RFSAPXV86-906515-C Sector Frame (12)15/8" Coax Sprint Nextel 6 Scala AP15-850/090 179.0 179.0 3 RFSATMAA1412D-1A20 Sector Frame (12)15/8" Coax (3)1.24" Hybrid T-Mobile 3 Nokia FRIG w/o Solar Shield 3 RaycapASU9338TYP01 3 Nokia FXFB 3 AndrewSBNHH-1D65B 6 CellMaXCMA-BDHH/6520/EG-8 170.0 170.0 9 RFS ACU-A20-N Sector Frame (3)11/4" Hybriflex (1) 0.87" Fiber Sprint Nextel rz: �EriE�on RRUS 31 B25 � =Eritsso�tn ROS-S1800MHz +" "R%,APXV9f131118-C 155.0 155.0 6 RFSFDGW5504/30-3 Sector Frame - AT&TMobility 153.0 153.0 3 Kathrein 78210254 (2) 0.76" 8 AWG 6 Coax )0.39" Fiber (1) 3/8" Fiber Trunk (1) 3/8" ableRET Control Cable 6 Kathrein 86010025 3 RaycapDC2-48-60-0-9E 9 RFSATM192012B-0 1 Raycap DC6-08-60-18-8F. 6 Ericsson RRU511(Band 12) (551b) 6 Kathrein 80010121 3 Kathrein 80010764 K 141.0 141.0 2 Andrew UHX6-59W Leg (4) EW52 121.0 121.0 1 AndrewUHX6-59W Leg (2)EW52 Verizon 101.0 101.E 1 AndrewUHX6-59W Leg (2)EW52 Equipment to be Removed Elevation' (ft) C1ty Antenna Moun[Type Lines Carrier Mount RAD 170.0 170.0 - - Sprint Nextel 3 TM 5AP-lXR ATCTower Services, Inc 3500 Regency Parkway, Suite 100- Cary, NC2751g-91946"112 Eng. Number OAA689477_C2_01 ANovember 3 2016 Page 2 of 2 AMERICAN TOWER' CO R PO P AT ION Pr000sed Eauioment Elevation' (ft) Qty Antenna MountType Lines Carrier Mount RAD ,owArgus;LLPX411R-V4 (3) 0.21" Cat 5e 170.0 170.0 Sector Frame (2) 0.87" Fiber Sprint Nextel kia*FWHR (1)1.16" SCOW (1)1" Conduit 'Mount elevation is defined as height above bottom of steel structure to bottom of mount, RAD elevation is defined as center of antenna above grade level (AGL). Install proposed coax alongside existing Sprint Nextel coax. The existing and proposed loads listed in the tables above are compared to the tower's current design capacity or previous structural analysis. The tower should be re-evaluated as future loads are added or if actual loads are found different from those listed in the tables. a su -lect tower`and-fomrdation-ore a eauatexo su000rt the 1D8/EDR Aldin Tan Nov 3 2016 1:06 PM Reviewed By: AldinN.Tan, PE Structural Engineer IV x No.68883 or *a — �� STATE OF Aldin N. Tan, PE COSTATCTowerServices, Inc 3500 Regency Parkway, Suite 101) Cary, NC27518 PY FLo. 53 "'! L FLCOA COANo903 ATCTower Services,Inc 3500 Regency Parkway, Suite 100-Cary, NC 27518-919A68-MI2 Office —919-46G5414 Fax -w .americantower.mm