Loading...
HomeMy WebLinkAboutVOID PLANS6L;ANNED BY St. Lucie County S p r SITE INFORMATION PROPERTY OWNER: FCC ENVIRONMENTAL LLC 523 N. SAM HOUSTON PARKWAY E., SUITE 400 HOUSTAN, TX 77060 LATITUDE (NAD8.3,)� 27 227 45.9978" N 1 27.379444' LONGITUDE '(NAD$3)� 80' 22' 54.9984" W -80.381944' COUNTY: ST. LUCIE ZONING JURISDICTION: ST. LUCIE COUNTY o) POWER COMPANY: FLORIDA POWER & LIGHT 1-(800)-468-8243 SPRINT CONTACT: O N USA BRYANT L3 MOBILE: (386) 717-1652 EMAIL' lisa.bryonf®sprint.com 0 int AREA MAP PROJECT: 2.5 MM OVERLAY ON NETWORK VISION SITE NAME: MIDWAY ROAD ST. LUCIE COUNTY SITE CASCADE: M 113XCO52 PLAN RED SITE ADDRESS: 5690 W. M 1 DWAY ROAD FORT PIERCE, FL 34981 BLDG:k1 DATE: Z -10- SITE TYPE: ±300'-0" SELF-SUPPORT TOW 10Ec: N �4, * " O - an6 Products„G,. Any �ertT� . Y�F Y i r 4K ,. t LOCATION MAP m *' 1 1 2 1 3 PROJECT DESCRIPTION • INSTALL (3) 2.5 ANTENNAS • INSTALL (3) MINI -MACRO RADIOS • INSTALL (3) JUMPERS • INSTALL (1) FIBER/ETHERNET CONDUIT / • INSTALL (1) POWER CABLE APPLICABLE CODES ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT CONDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES: 1. FLORIDA BUILDING CODE 2014 WIND DESIGN CRITERIA: A. ASCE 7-10 BASIC WIND SPEED= 158 MPH (ULTIMATE 3S GUST) RISK CATEGORY= 11 EXPOSURE- C B. ANSI/EIA/TIA-222-0 (ALLOWED PER EXCEPTIONS #5 OF 1609.1.1, FBC 2014) BASIC WIND SPEED= 122 MPH (NOMINAL 3S GUST) STRUCTURE CLASS= 11 EXPOSURE= C IMPORTANCE FACTOR= 1.0 2. FLORIDA FIRE PREVENTION CODE- 5th EDITION-2014 3. NATIONAL ELECTRICAL CODE (2011) 4. CITY AND/OR COUNTY ORDINANCES GENERAL NOTES U. COMRACTOR SHALL VERIFY ALL ALL NEW PLANS AND EXISDNG DIMENSIONS CONSTRUCTION AND COMMONS ON THE JOB _SRE AND SHALL IMMEDIATELY ITEMS TO BE NOTIFY TBE A/E nRM IN WRBNG INSTALLED PER OF ANY DISCREPANCIES BEFORE KnOWWIIBES below. PROCEEDING R BEERESPONSBIEMR SAME. SPECIFICATIONS SPRINT SPECIFICATIONS CBI1 before you dig. www.WI911.mm DRAWING NOTICE THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF SPRINT AND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUT THE EXPRESS WRITTEN CONSENT OF SPRINT 4 PLUMB: 30 f J. I D1.ECH ACT^E:J r ROBE R JERRYWW I Gyll• In REGISTEREDPRCRTECi STATE OF RORM DATE: 0 B2, DRA ,ING IN HEET NO SHEET TITLE ISSUE 0 11/m/18 ISSUED MR PERIL f T-1 TITLE SHEET & PROJECT DATA 0 A 10/14/16 ISSUED MR REVIEW No. Date Action SP-1 INSTALLATION SPECS & EQUIPMENT - 0- - Client C-1 SITE PLAN 0 A-1 EQUIPMENT PLAN ER PROFILE 0 A-2 ANTENNA T UNTING DETAILS 0 ® \ A-3 EQ NT DETAILS G Sprint ONCEALED FASTENERS OR ATTA 1ENTS eMOSPRINTPARRWAY ARE THE RESPONSI61LCf1' OF T ' E oVERLSND PARK, IANSAS WU1 CONTRACTOR OF REC9 A/E Consultant: E 1 AC POWER DISTRI O E-2 .,_ANTEN__JNHA ROU DING PLAN & GRO NG DETAILS 0 m�I THESE PLANS L PROPOSED WORK MORRISON H'1 S4 FIELD Tw SISON lry R SHFI Plenle4on FL]Sf20 p pp ������ /�/�qfp�/� p��L ARE SUI? I� illlY VD 1n ECTIDWS Tm: es OFFUss F,.:es 6rlmR STALE OFFLORI0A CO0MWt50a ...,mom:eon.anew.� REO SD6YFTELOI{JSf1 mongTHAT MAYBE NEC1160ARY IN OMER To Protect: QQMP6YWITH "APPI.JCA®L900D _, MIDWAY ROAD M113XCO52 569D W. MIDWAY ROAD FORT PIERCE, FL 34981 PROFESSIONA ' STATEMENT DfaI Title: TITLE SHEET AND I HEREBY CERTIFY THAT THESE DOCUMENTS ERE- A E PROJECT DATA APPROVED BY ME, AND THAT AM DULY LICENSED PRO ESSIONAL ENGINEER OR ARCHITECT UNDER THE LAWS OF THE STATE OF FLORIDA. 7160111 PROFESSIONAL OF RECORD: MORRISON HERSHFIELD CORPORATION D.Iprwr, Daly ROBERT LARA, AIA LB 11/02/16 rlara®morrisonhershfield.com PHONE: (954) 577-4655 D.. �, . EIMIked �„ FL LICENSEj/: 92624 RM CC RL PM Rabr DOI AavK•Lal YAN WANG. PE P8 � y W'ng®morrisonhershfield.com PHON ) 77-4655 FL LI 226. p ®q�7 so O T-1 5 1 6 CL[.K•II0a C 19 SO p� i LV REV. 0 7/25/16 SPRINT CONSTRUCTION SPECIFICATIONS MINI —MACRO CELL SITES BASIC REQUIREMENTS a) MEET ALL REQUIREMENTS OF JURISDICTIONS. b) IF EQUIPMENT FURNISHED BY COMPANY DOES NOT MATCH THE EQUIPMENT LISTED ON THE RFDS AND SHOWN ON THE PERMITTING DRAWINGS, RESOLVE DISCREPANCY THROUGH INSTALLER'S CONSTRUCTION MANAGER AND COMPANY'S POINT OF CONTACT. c) CABLE INSTALLATIONS I) ALL CABLES MUST BE OUTDOOR RATED AND HAVE UV RESISTANT OUTER JACKETS. ii) CABLE BENDS MUST NOT EXCEED MANUFACTURER'S ALLOWABLE CABLE BEND RADII. iii) AT RADIOS INSTALL SERVICE LOOPS FOR POWER, FIBER AND ETHERNET SECURED AT LEAST TWICE AT 180 TO THE STRUCTURE. iv) SPARE FIBERS MUST BE ENCASED IN A LOW PROFILE WEATHERTIGHT ASSEMBLY d) FIBERS MUST BE FIELD —TERMINATED WITH LC —TYPE CONNECTORS. e) CONDUITS IN EARTH: PROVIDE PVC. CONDUITS EXPOSED AND IN FACILITIES: PROVIDE RGS. HAND DIG TRENCHES IN COMPOUNDS. f)SECURE AND SUPPORT CONDUITS AND CABLES ON NO MORE THAN 48'INTERVALS. g) ON TOWER SITES RGS CONDUITS MAY BE SURFACE MOUNTED AWAY FROM WALKWAYS AND ACCESS/EGRESS PATHS. IF INSTALLATIONS IN WALKWAYS AND ACCESS/EGRESS PATHS CANNOT BE AVOIDED, IDENTIFY THE CONDUIT ENVELOPE / TRIP HAZARD BY ALTERNATING YELLOW AND BLACK STRIPES PAINTED ON CONCRETE AND CONDUIT. 2 SPRINT —FURNISHED EQUIPMENT a) INSTALL THE FOLLOWING EQUIPMENT AT LOCATIONS AND AZIMUTHS SHOWN ON THE CONSTRUCTION DRAWINGS. i) PANEL ANTENNAS ii) RADIOS iii) GPS ANTENNAS iv) FILTERS iw)120 VOLT DIN —RAIL CIRCUIT BREAKER ASSEMBLY 3 TOWER INSTALLATIONS a) MEET ALL REQUIREMENTS OF THE TOWER OWNER. b) INSTALL CORRUGATED FLEXIBLE CONDUIT UP THE TOWER TO COMPANY'S RAD CENTER. c) PROVIDE HANGING GRIPS OR CONDUIT CLAMPS AND ENSURE CONDUITS AS WELL AS INNER CABLES ARE SUPPORTED. d) CONDUIT RISERS: AT TOP OF TOWER TURN CONDUIT DOWN AND PROVIDE CABLE TERMINATION FITTINGS. EXTEND CABLES TO RADIOS EXPOSED AND SECURED TO STRUCTURE. AT CONDUIT EXIT FROM TOWER, PROVIDE DRIP LOOPS AND WEEP HOLES. e) AT ICE BRIDGE RUN CABLES IN RGS CONDUIT. UTILIZE CONDULETS TO MAKE COMPACT 90 DEGREE TURNS. 4 AC POWER TIE—IN a) INSTALL SPRINT'S 120 VOLT DIN —RAIL CIRCUIT BREAKER ASSEMBLY IN THE EXISTING POWER PROTECTION CABINET TELCO SECTION. b) INSTALL A 20 AMPERE MOLDED CASE CIRCUIT BREAKER IN AVAILABLE SPACE IN THE ADJACENT PPC POWER SECTION LOAD CENTER. 5 GROUNDING a) 120 VOLT CIRCUITS: POWER CABLES MUST BE 3—WIRE WITH EQUIPMENT GROUNDING CONDUCTOR. b) SUPPLEMENTAL GROUNDING: ALL GROUNDING HARDWARE MUST BE UL STAMPED AS SUITABLE FOR GROUNDING HARDWARE. - c) RADIOS: BOND RADIO TO THE TOWER TOP OR SECTOR GROUND BAR WITH #8 BARE TINNED COPPER WIRE (GREEN INSULATED ON ROOFTOPS). d) DIN —RAIL CIRCUIT BREAKER ASSEMBLY: BOND SURGE ARRESTOR TO PPC TELCO BOARD GROUND BAR. 6 MINOR DETAILS a) CONDUIT b) i) RIGID GALVANIZED STEEL CONDUIT (RGS): UL LISTED, COMPLIANT WITH ANSI STANDARD C80, HOT —DIP GALVANIZED, WITH THREADED FITTINGS. MANUFACTURERS: ALLIED REPUBLIC, WHEATLAND, OR EQUAL 1i) CORRUGATED FLEXIBLE CONDUIT: DURAUNE OR EQUAL. iii) LIQUID —TIGHT FLEXIBLE METALLIC CONDUIT (LFMC): UL LABELED, UV RESISTANT, FLAME RETARDANT PVC JACKET, HOT —DIP GALVANIZED, GREY. MANUFACTURERS: AFC, ANACONDA, SOUTHWIRE OR EQUAL iv) PVC CONDUIT: SCHEDULE 40. CARBON OR EQUAL v) CABINET HUBS AND CABLE TERMINATION FITTINGS: OZ GEDNEY OR ROXTEC b) COAXIAL CABLE JUMPERS: %"LDF-4. MANUFACTURERS: COMMSCOPE, RFS OR FCT. c) FASTENERS AND HARDWARE i) TO SECURE RACEWAYS, UTIUZE NON CORRODING NON—MAGNETIC METALLIC FASTENERS AND HARDWARE SUITABLE FOR THE PURPOSE. d) POWER CABLES — 3/C 012 SOOW BY SOUTHWIRE OR EQUAL. e) ETHERNET CABLES AND CONNECTORS: OUTDOOR RATED, CAT SE, BELDEN OR EQUAL. f) FIBER CABLES: CORNING 'FREEDOM FAN OUT'OUTDOOR RISER CABLE, 4F, SINGLE MODE, OR EQUAL. g) RF TRANSPARENT PAINT FOR ANTENNA CONCEALMENT: SELECT NO/LOW CARBON PAINTS, WITH NO/LOW TITANIUM DIOXIDE, AND WITHOUT SUSPENDED METAL PARTICLES (ALUMINUM, ZINC, COPPER, ETC.) 7. COLOR CODING N) COLOR CODE CABLES AND CONDUITS AS REQUIRED BY SPRINT STANDARD TS-0200. B. TESTING AND CONSTRUCTION COMPLETE a) SWEEP ALL COAXIAL CABLES ACCORDING TO SPRINT STANDARD TS-0200. b) PANEL ANTENNA ALIGNMENT — USING ELECTRONIC ALIGNMENT TOOL. AZIMUTH/DOWNTILT +/— 1 DEGREE. c) LEAVE EQUIPMENT DE —ENERGIZED UNTIL INSTRUCTED BY THE COMMISSIONING AND INTEGRATION TEAM TO ENERGIZE. d) OTHER REQUIREMENTS AND DELIVERABLES MAY BE REQUIRED BEFORE THE CONSTRUCTION COMPLETE MILESTONE CAN BE ACTUALIZED IN SITERRA (SPRINT'S DATABASE —OF —RECORD). LL2X310R— V4 RADOME MATERIAL: FIBER GLASS. UV RESISTANT RADOME COLOR: LIGHT GRAY DIMENSIONS, HxWxD.in (mm): 42.1"xl 1.8"x4.5" (107Ox3OOxl 15mm) WEIGHT: 28.66 Ibs CONNECTORS: (4) LV a 4.5 SIDE VIEW FRONT VIEW RF CONNECTORS O O O o CALIBRATION ® CONNECTOR AISG BOTTOM ANTENNASPECS VIEW ANTENNA SPECS RADIO SPECS J. ROSERTJEWLAPA REGISTEREDARCHITECT STATE OF FLORIDA 0 1 11/02/18 ISSUED FOR PEHOF A 1 10/14/18 ISSUM FOR RE&V No. Date I Action CIlenb. Sprint \00* e5805PRINTPARMAY OVERLAND PARKK SAS=51 A/E Consultant: m� MORRISON HERSHFIELD Twrt sam umwmry Lrte, smu eas, PlsndWn. FL,••,a Ttl; B5G.5i1Afi55 Fu:GN.5714LY STAR OF FLORIOA LO/ WSLSOL w.v.martlsoNwrNMN.am Project:MIDWAYROAD M113XCO52 5690 W. MIDWAY ROAD FORT PIERCE, FL 34981 DTowing Title: INSTALLATION SPECS & EQUIPMENT PY R~. MrA Appvai PB lam No. D.Inp No. 0 SP-1 C C 3 0 2 3 4 1 5 6 a S.mwxwv. 1i N m EXISTING 6'-0" WIDE //^\+EACCESS GATE (TYP.) x—x—x—x x x x—X—! —x+fix—x—x—x—x� x x EXISTING CONCRETE EQUIPMENT x a PAD (BY OTHERS) (TYP.) `+ ` EXISTING 3300'-O" HIGH x SELF-SUPPORT TOWER / x EXISTING SPRINT/NEXTEL EXISTING AT&T CONCRETE x CABLE BRIDGE EQUIPMENT PAD i EXISTING 2B SPRINT/NEXTEL EXISTING CHAIN Ix EQUIPMENT SHELTER LINK FENCE �I x EXISTING SPRINT CABLE BRIDGE 2A EXISTING SPRINT/NEXTEL TELCO x CABINET EXISTING CABLE BRIDGE (TYP.) I EXISTING 10'-0" NO SPARK BUFFER ZONE L " EXISTING PROPANE TANK I x O I x ' \ x— EXISTING SPRINT CABLE BRIDGE KEYED CONDUIT CALL OU15: ® PROPOSED 1 1/2' CONDUIT FOR AC POWER W/ SOOW CABLE FROM EXISTING PPC TELCO CABINET TO SPRINT ICE BRIDGE TERMINATION POINT AT CELL TOWER. SEE SHEET E-1 FOR CONDUIT MATERIAL & ROUTING DETAILS. 2B PROPOSED SOOW CABLE FROM SPRINT ICE BRIDGE TERMINATION POINT AT CELL TOWER TO SPRINT LEASED RAD CENTER. SEE SHEET A-2 FOR ROUTING DETAILS. ® PROPOSED 1' CONDUIT FOR FIBER & ETHERNET FROM EXISTING NV MMBS CABINET TO SPRINT LEASED RAD CENTER. SEE SHEET A-2. USE EXISTING SPRINT UNDERGROUND CONDUITS FOR GROUND RUN. VERIFY UNDERGROUND CONDUITS CONDITIONS AND COORDINATE IN FIELD. NOTIFY MH OF ANY DISCREPANCY. 2 r SITE PLAN EXISTING SPRINT UNDERGROUND CONDUITS RUN FOR CABLES. � SEE KEYED CALL OUT7 x—x—x—x—x -EXISTING SPRINT EQUIPMENT CABINETS 24"x36" SCALE: 1/4" = 1'-0" 11"x17" SCALE: 1/8" = 1'-0" 4' 3' 2' V 0" 4' 3 t 4 —x= x EXISTING T-MOBILE CONCRETE EQUIPMENT PAD EXISTING UTILITY H-FRAME (TYP.) R01304JEIRYW 0 I i vamial issum mR PF]00f A 10/14/te mum FOR REVatl No.1 Date I potion Client Sprint 6MOSPRIMPARK AY OVERW DPARK,KANSASWB l A/E Consultant: rrEm MORRISON HERSHFIELD noswAu W omas��us, w.�ume. tissue r.,eusn.wss F..:essen.wsa SLATE OF FLO W OA COF [MtlSM wwmdXimp"NTYt[an Project: MIDWAY ROAD MI13XCO52 5690 W. MIDWAY ROAD FORT PIERCE, FL 34981 Drawing Title: SITE PLAN om.n er. Sr. OC/RL RM CC RL COPPM Rater. Caalt APP.1 ®pr(� PB v I e Na Olmlo9 NO. ([e o C-1 p 6 5 6 eai. eemuax>rvea C 3 11 9PROPOSED 1 1/2' CONDUIT FOR AC POWER W/ SOOW CABLE FROM EXISTING PPC TELCO CABINET TO SPRINT CABLE BRIDGE TERMINATION POINT AT CELL TOWER. SEE SHEET E-1 FOR CONDUIT MATERIAL & ROUTING DETAILS. 2B PROPOSED SCOW CABLE FROM SPRINT CABLE BRIDGE TERMINATION POINT AT CELL TOWER TO SPRINT LEASED RB COTTER. SEE SHEET A-2 FOR ROUTING DETAILS. ® PROPOSED I- CONDUIT FOR FIBER & ETHERNET FROM EXISTING NV MMBS CABINET TO SPRINT LEASED RAD CENTER. SEE SHEET A-2. USE EXISTING SPRINT UNDERGROUND CONDUITS FOR GROUND RUN. VERIFY UNDERGROUND CONDUITS CONDITIONS AND COORDINATE IN FIELD. NOTIFY MH OF ANY DISCREPANCY: EXISTING t300'—D" HIGH SELF—SUPPORT TOWER NOTE: THE NEW CONSTRUCTION WILL NOT DISTURB OR DESTROY EXISTING LANDSCAPING OR TREES. 3RD PARTY INSPECTIONS CONTRACTOR SHALL BE RESPONSIBLE FOR HIRING ALL 3RD PARTY SPECIAL INSPECTIONS AS REQUIRED BY MUNICIPALITY NOTE PLAN INFORMATION CONTAINED HEREIN IS TAKEN FROM DOCUMENTS PROVIDED BY THE CLIENT. NEITHER WARRANTY NOR GUARANTEE IS GIVEN BY THE ARCHITECT NOR MORRISON HERSHFIELD CORPORATION TO THE ACCURACY NOR THE COMPLETENESS OF THE COMPOUND OR EQUIPMENT PLAN INFORMATION. C.L. OF EXISTING PANEL ANTENNAS ELEV. = 3262'-0" A.G.L 1 ROBERT JERKY IAJIA O REOISTERED ARCMIECT BTA STAiEOFROOFROPoM TJ Af61B}I L?U IX C.L. OF EXISTING PANEL 0 tt/oz/ts mum FOR 1'F3e0f PROPOSED SPRINT 2.5 ANTENNA s A ANTENNAS ¢ A 10/14/16 MWED FOR REVIEW >< 2B ELEV. = t182'-0" AG.L (1 PER SECTOR, TOTAL OF 3) i 3 of EXISTING AT&T 0 No. Date AMlon C.L. OF 3 EXISTING AND 3 Client CONCRETE NEW SPRINT PANE ANTENNAS J. EQUIPMENT PAD 0 O_ m / ELEV. - f170'-0" A.G.L. 0 0 ' C.L. OF EXISTING PANEL PROPOSED MINI —MACRO ANTENNAS RADIO (1 PER SECTOR, z ri • , i ELEV. = 3153'-0" A.G.L TOTAL OF 3) N w Sprint z to g C.L. OF EXISTING MW DISH I'J I ANTENNA 0580SPRINi PARKWAY / ) / ELEV. = t104'-0" A.G.L OV RW DPARK ,I SAS SW61 EXISTING ±300'—O" n c C.L. OF EXISTING MW DISH SELF—SUPPORT TOWERGH ANTENNA A/E Consultant: c ELEV. = 3124'—O" A.G.L N iO UNDERGROUND CABLE RUNOUIT �Y EXISTING IN EXISTING4 CONTRACTORC ON C.L.DVERIFY ANTENNA EXISTING MW DISH MORRISON HERSHFIELD m PROPANE TANK CONDUIT CONDITION IN FIELD ELEV. = f104'—O" A.G.L AND NOTIFY MH ON ANY tw swPuwv,T�vm.,swmzas, Wve=, R.zax, a ia: esa.sn.ass P.::vusnaese \ DISCREPANCIES.El siAre oiiwa"ivcNvvvvssm 12 LEI ---' — PROPOSED (1) 1- CORRUGATED PVC CONDUIT OI I & (SOOW CABLE Project: S� ROUTED ALONG EXISTING MIDWAY ROAD CABLES ROUTE M113XCO52 5690 W. MIDWAY ROAD 0 x// EQUIPMENT CABINETS C BINETS FORT PIERCE, FL 34981 •t X- %XX X X-X-%-X- XXX-X N c EXISTING SPRINT EQUIPMENT - - Drawing Title: ,n EXISTING SPRIT CONCRETE CABINET (TYP.) STING nFENCE CHAIN EQUIPMENT PLAN & E EQUIPMENT PAD a EXISTING CHAIN TOWER PROFILE LINK FENCE O'-0" REFERENCE EXISTING SPRINT CABLE - FINISHED GRADE 20 A.M.:L) R Il t1w m BRIDGE (TYP.) 7160111 NOTE: Ddpmr. Data NO WORK SHALL COMMENCE WITHOUT THE APPROVED TOWER/ANT NT UCTURAL LB 11/02/16 ANALYSIS REPORT SIGNED AND SEALED BY A LICENSED PROFESSI NE DE Dmn W. OmY<i BA: n at SEPARATE COVER. IF REQUIRED, THE CONTRACTOR SHALL MODIFY FOR11� E NT RM COAL z MOUNTS AS INDICATED IN THE ABOVE MENTIONED STRUCTURAL R ������TE CM0 AW&M MODIFICATION DESIGN DRAWINGS. L A EQUIPMENT PLAN gyp i�1 TOWER PROFILE •"' °°`"^°"a 0 2 A-1 24"x36" SCALE: 1/4" = 1'-0' `vet, x A-1 24"x36" SCALE: 1/16" = 1'-0" A-1 i 11"x17" SCALE: 1/8" = 1'-0" 4' 3' 2' 1' 0" 4' 11"x17" SCALE: 1/32" = 1'-0" i6' 12' 8' 4' 0" 16' 1 2 3 4 5 6 m"•�"""' p� f C I1 SECTOR 1 SECTOR 1 1C �rnmElu.�,w�uvr..wronB un�ro�vw�' 1C (AZ 335')Arnan',`""".,,,.,,sswvno�Rno..waw,walo.Re owEimam mxwr rwmaxanw ®ID W EOEO B V TIE M1FHr PF9AL /.LL pi/.vAYav PE<g14TPX91¢MYM T ®FnOF4RIY oG r (AZ 1340') (AZ 1340') uowuson RF�IF�n ra+no+"T e... I.Enssr. MmIN61. o IENEL i Protessior(o [ n 1A EXISTING SPRINT SECTOR IA j XISTING SPRINT SECTOR MOUNT (TYP.) OUNT (TYP.) QFL. EXISTING 3300'—O" HIGH EXISTING 3300'—O" HIGH �t�rr. `�U •R7 E SELF—SUPPORT TOWER SELF—SUPPORT TOWER i TT'�J 3C 3C • t 'A' 5 2A i 82 EXISTING SPRINT 800/190D EXISTING SPRINT 800/1900 ANTENNA ANTENNA 11 1 cSECTOR) (TYP OF 1 PER SECTOR) ( OF 1 PER m 2B B R C� 3B (AZ 100) 36 107) �� SECTOR 2 h' (AZ 270') SECTOR 2 � (AZ 270') R0RIMJERRYt(VA , o SECTOR 3 SECTOR 3 REGIST6RBDARWIIECI EXISTING SPRINT RRUs EXISTING SPRINT RRUs RTAiEOF ROPoDA (TYP. OF ALL SECTORS) NOTE; (TYP.OF ALL SECTORS) A`�d c REPLACE EXISTING PIPE NEW MINI —MACRO RADIO WITH o MOUNTS WITH NEW 2-1/2' INTEGRATED GPS ANTENNA NEW i 2.5 ANTENNA STD. (2-7/8' O.D) GALV. (TYP. OF 1 PER SECTOR)TYp. OFIIIT PER SECTOR) m 3A °1 SCH. 40 PIPE AS REQUIRED 0 11/02/16 ISSUM FOR PEWIT2C > 3A (AZ 219) (AZ 110) £ TR A 10/14/16 MSUM FOR REYOWW A �,y PROPOSED ANTENNA LAYOUT @ 170'-0", G°a �`� `°° EXISTING ANTENNA LAYOUT @ 170 -0 �O L NA-2 NOT TO SCALE IN,A-2 NOT TO SCALE ry gKEYED CALLOUTS LEGEND: CONDUIT NOTES: C ® �� O7 OEM PROPRIETARY ✓print POWER CABLE 1. SECURE CONDUITS TO EXISTING EQUIPMENT PAD WITH CONDUIT c58D SPFIW PARIMAY CLAMPS AS REQUIRED. CONTRACTOR SHALL INSTALL CONDUITS I I I ovERWD PARK KANSAS W251 m 2B SCOW CABLE IN ACOMMANNERON TO REDUCE YELLOWN& HAZARDS.BLACK MINT REQUIRED. EXISTING SELF—SUPPORT I I I © 1/2" RF JUMPERS I 2. CONDUIT FILL: ® — 9/C #10 AWG SOOW CABLE NEW (1) 1' CORRUGATED 4 ETHERNET FIBER CABLES 3 ETHERNET & (3) FIBER CABLES PVC CONDUIT & (1) SOOW CABLE o BET / i ® — () ROUTED ALONG TOWER LEG I A/E Consultant: NEW MINI MACRO RADIO NEW (1) 1OXBX8 NEW (1) 1 1/2' CONDUIT NEW (1) 1OX8X8 m W/ INTEGRATED GPS POLY —CARBONATE I NEW DIN —RAIL W/ EXISTING SPRINT H—FRAME POLY —CARBONATE I I x I. JUNCTION BOX W/ w/ PPC CABINET NEW (1) 1' RGS RO JUNCTON BOX III I I MORRISON HE�SHFIELO UNIT I CORD WHIP. (3) SOOW CABLE I ALONG CABLE BRIDGE (MOUNTED 7A CIRCUIT r.awnvxw.lpom..wuxs. i ANTENNA BEMOUNnNGFLUSH TERMINAL BLOCK I .SELF—SUPPORT BREAKERS & SPD EXISTING TO CABLE BRIDGE) I I Planbum. FLd9IIi BATTERY _ Taps OFFIXR FA PEAVT.bY PIPE TO BE FLUSH TOWER LEG EXISTING NV Illl I B 1'—D STATE OFFLORIpACOO WMLWt WITH TOP OF ANTENNA i CABINET MMBS CABINET CABLE RBRIDGE ....I.wn.o.e.l.nnw.oTl TELCO CONTRACTOR SHALL C1 IL 36V" OF z 1 i O CAB. ETHERNETCDCA13LE WITH 3 �d 4 I POWER RJ45 TERMINATION ^ NEW COTERMINNDUIT I Pro�e`LMIDWAY ROAD pff EI cne. CONTRACTOR FITTINGS�ATIONI MI13XC052 5690 W. MIDWAY ROAD o 2B SHALL COIL W CABLEI CONTRACTOR FORT PIERCE. FL 34981 m1 a 36" OF 4 EXISTING TOWER I I SHALL SUPPLY N SOOW CABLE I COAX ENTRY PORT WEEP HOLE I I MINATE FIBER IN CONDUIT Growing Title: y N I 0 0 0 I TAT�EXSTING CSR I I AS REQUIRED ANTENNA LAYOUTS I MMBS & MOUNTING IN NV z • I NEW ROXTEC I 2A CONDUIT ge CONDUIT EXISTING AC SPRINT EQUIPMENT PAD BODY ) SEAL OR DETAILS S I I RECEPTACLE :; 5 APPROVED I x"%. .}AST^vz ...T'�:P:... .�•..;.r'• .r'.. .a: r. x.`.�'r e..-!'as m"aw". ..::=s"ss.-•r�;......sr ,� \\ emu•.-*'s:' w.:.. :—e._e„ 776011'1. EQUAL III I �\��\//i�j�%i��jj/�\jj ��jj%/i�%/����/i\�j��j%/\%\i//.%/T///�C/��/%//\��%%/%%//%\%��\y/%\��\/�\/%��/%/���/%\�%\��/i LB u .� t %oz/t6 m A CONTRACTOR SHALL NEW (1) 1' dam ep Ow.)*d Sr. n I NEW 1 1/2' UL LISTED NEW 1 1/2' RGS e ROUTE & SECURE RET CORRUGATED NEW 1' UL LISTm LIQUIDTIGNT LIQUIDTIGM FLEXIBLE ROUTID ALONG EDGE RM CC L o ASIG CABLE AS REQUIRED PVC CONDUIT FLEXIBLE METALLIC CONDUIT — TO ADJACENT NV 1.9 & 1 SOOW I METALLIC CONDUIT — 3' OF CONCRETE PAD 3' MAXIMUM LENGTH (RIP"fry-7COP Rmlt•.: rnmnt Appval ANTENNA AT SECTOR CABLE ROUTED I I MAXIMUM LENGTH - ON PAD AT CABINET Lori- 8 m AT PPC RACK LOCATION ALONG TOWER LEG • 11 lavue Na OrnIR9 N. (ANTENNA MOUNTING ELEVATION MOUNTING ELEVATION EQUIPMENT ELEVATION DETAIL L F O L2 NOT TO SCALE IN,A-2 NOT TO SCALE A_2 8 1 2 3 1 4 5 6 D •! mxorecaE°ux++oa. mnvnnmumrvwwui lV aoma°s.+m.wme m®nTAxre a.Nr wwm m MY690O.,o)v.VOAlY.9 W 4[pFlGTIP9TONOR ¢xonrexuLBEOaTFAawiFP WR,WfFR[Lt WIMFN I �Y4W®ALLBTT® I�V19�W�/Ji°Mrn.�Ha.�N' u"'ORnisM,.FAID161ElOW RRvaTMiuenoM XET�I!°P wPnnieoN NEPsni�ETn NORme n�>€ a°A � RRVPOi07N Tr mAEcr. N iProfessio "0' EXISTING/NEW 2 1/2• (2 7/B• ! OF O.D.) X 6'-0• LONG SCHED. 40 HOT DIP GALV. MOUNTING PIPE MINI —MACRO RADIO RR ,J MOUNTING BRACKET & ,Q �0 H iFWLD ORF HARDWARE (TYP.) ' O O �� FR........ 0 ED . NEW MINI —MACRO e RADIO (REFER TO O O SHEET SP-1 FOR ROBERTJERRYLARA o DETAILS) REGISTEREDARCHTIECT �qJ STATE OF R1 RDA 8 � , oV K 0 TimmR11m FOR PowC a A to/ts/te 5wm FOR REVIEW rc D No. Date Action Client z UUN{f N \ Spring A MINI -MACRO RADIO MOUNTING DETAIL B NOT USED 65005PRINTPAH WAY RIANO PARK HANSAS W3E' OVE m A'3 NOT TO SCALE A-3 n m w 2 A/E Consultant c N 8 m MORRISON HERSHFIELD s T.<swx �m..nnyom.,s.mzas, g vw�um�,nawz. ' TY-OSO S77iG55 ia'L5051INY PROPOSED ANTENNA AND COAX SCHEDULE SECTOR ALPHA AZIMUTH W CENTER M. VENDOR MODEL ElEC TILT D WNTIMECH.T FEEDERSNUMBER F FEEDER TYPE FEEDER UENMH ADDITIONAL EOUNIME 1T ANTENNA 335' 170'-0• 1 LLPX31 OR—V4 — Or 1 ETHERNET/FIBER t235'-0• WALPHA 1 MINI MACRO — — 1 NOKIA MINI —MACRO RADIO — — SCOW 9 CONDUCTOR f200'-0' POWER CABLE SECTOR BETA AZIMUTH RAD CENTER CITY. VENDOR MODEL EIEC TRY DOWN NSF FEEDER WFE FEEDER LEN61H ADDITIONAL EQUIPMENT ANTENNA 110, 170'-0• 1 PHA LLPX31 OR—V4 — 0' 1 ETHERNET/FIBER t235'-0• WIRELESS 1 MINI MACRO — — 1 NOKIA MINI —MACRO RADIO — — SCOW 9 CONDUCTOR t200'—D• POWER CABLE SECTOR GAMMA AZIMUTH RAD CENTER OTY. VENDOR MODEL EJE/ W MECH DOWNIILT NSF FEEDER TYPE FEEDER LENGTH ADDITIONAL EQUIPMENT ANTENNA 210' 170'-0• 1 ALP WIRELESS LLPX31 OR—V4 — 0' 1 1 ETHERNET/FIBER >t235'-0• MINI MACRO — — 1 NOKIA MINI —MACRO RADIO — — SCOW 9 CONDUCTOR t200'-0• POWER CABLE STATE OF FLOROA CO/ O6 Pro)eeL MIDWAY ROAD M113XCO52 5690 W. MIDWAY ROAD FORT PIERCE, FL 34981 ,74 Growing Title: EQUIPMENT DETAILS PT.J.d Na 7160111 /02/16 m LB 1 n . Ram W. amw Ely: RM CC g • m Rim. CHIA APKO.W m EQUIPMENT SCHEDULE PS - - Imue Na Drv.N9 Na A 3 NOT TO SCALE (BASED ON 22' z 34" PAPER) NOT TO SCALE (BASED ON 11" a 17" PAPER) 0 p —O /'1 J p@ i i 1 1 2 3 T 4 5 6 a ...vaa•vvm r SECTOR-7 SECTOR-2 SECTOR-3 ePeasir.Lnarav REA�.an+„E RnevmrroF ro CG SHALL REFER TO SPRINT EXISTING 200A GENERATOR MINI—MACRO RADIO SPECS FOR RECEPTACLE ee vxarai.amaalnuenoxkv�waFnmrrmcar `o LNOPnoan xwm,nr.Le ooawuTwx. �emm+ � MORE DETAILS TO EXISTING UTILITY I I °flX19O1n�La,mEuaowT�u+ae�LTxaL z METER AND MAIN FUSED DISCONNECT SWITCH OR O I az I Professi LOAD SUMMARY DESCRIPTION VA AMPS RRU #1 FED FROM 7A-1P CIR. BREAKER 360 3 RRU #2 FED FROM 7A-1P CIR. BREAKER 360 3 RRU #3 FED FROM 7A-1P CIR. BREAKER 360 3 TOTAL LOAD AT RECEPT. - 1080 9 CIRCUIT BREAKER MINI MINI MINI EXISTING 20OA-2P MAIN LOCATED AT J MACRO MACRO MACRO CIRCUIT BREAKERS TOWER TOP I .......... . OA EXISTING SPRINT PPC (1) 4F, SINGLE MODE tPr oY 3 FIBER CABLE AND (1) Y J [[gf00/QQQyyy777 TELCO CABINET E/F OUTDOOR RATED G: % p EXISTING ER A SPRINT NEW 1/2' COAX P I ETHERNET CABLE (TYP. Qj6 T J. PPC POWER CABINET NEW U RGSOO CONDOR WITH JUMPERS TOYP.OR) /F J p EACH SECTOR WITH AN EXISTING ) I�0 SON ERS IEjD� RP 120/24OV-10-3W, 200A 200 1 (3) OUTDOOR RATED ETHERNET EACH SECTOR) L — — — — — — — — — J . 1 CABLES AND (3) 4F, SINGLE (1) OEM PROPRIETARY POWER i RATED LOAD CENTER O BACKBOARD,,, MODE FIBER CABLES CONDNEW ROXTEC I w a I CABLE (TP. EACH SECTOR) 5 9 V R SEAL ;< NEW DIN RAIL MOUNTED BREAKER ASSEMBLY W/ (3) 7A-1P, 120V APPROOVED EQUAL I I NEW 10'x8"x8' POLY CARBONATED WEATHERPROOF re CIRCUIT BREAKERS, A SURGE I JUNCTION BOX rFRED PROTECTION DEVICE (SPD) AND A CORD WHIP FOR CONNECTION TO RECEPT I I NEW 1' CORRUGATED PVC m a CONDUIT W/ (3) OUTDOOR 0 ry EXISTING LOADS (REFER TO SPD CONTRACTOR TO COIL I w a I RATED ETHERNET CABLES AND 36" OF SCOW CABLE (3) 4F, SINGLE —MODE FIBER ROBERTJERRYLNP PANEL SCHEDULE) I I E/F E/F J �� REGISTEREDARCHIIECT STATE�RRORDA I U NEW MULTICONDU 9OCONDUCTOR SOUf12 �P P P SOOW FLEXIBLE MULTICONDUCfOR CABLE EXISTING 20A-1P BRANCH AWG FLEXIBLE CABLE FOR I I PC CIRCUIT BREAKER IN LOADCENTER FOR RECEPTACLE. DISTANCES < 200'-0'. FOR SPRINT CONDOR NEW 10'xB'x8' I I POLY —CARBONATED C 0 tt/oz/ts arum FOR F4laer VERIFY IN FIELD AND FURNISH IF NECESSARY DISTANCES > 200'-0'. PROVIDE #10 AWG. SDOW CABLE SHALL MMBTS TERMINATION CABINET FITTING WEATHERPROOF JUNCTION BOX I A to/u/ts arum wn sEhex EXISTING (2) j)12 AWG CU AND BE RAN IN 1 1/2' RGS CONDUIT ABOVE GRADE FROM PPC TELCO I I LOCATED SIDE INSIDE TOWER No. Date Action Client: (1) #12 G. IN MIN. 1/2" C. TO J—BOX AT A MAX DISTANCE o_ z VERIFY IN FIELD AND FURNISH OF 5D'-0' PER NEC 400.14 1 IF NECESSARY EXISTING 120 VAC, DUPLEX P P P P P J \� RECEPTACLE.VERIFYFIELD I I GRADEAND e x NECESSARY Sprint ELECTRICAL ONE -LINE DIAGRAM A E-1 NOT TO SCALE (BASED ON 22" x 34" PAPER) c u NOT TO SCALE (BASED ON 11" x 17" PAPER) OVERBt DPARK, x SASE 1 n EXISTING PANEL "PP1" 200A, 120/240-10-3W, 6OHz, 200A M.C.B. V LOAD WIRE GND COND AMPS BUS AMPS DOND GND WARE LOAD V ABUS B ABUS B 0 EXISTING SURGE SUPPRESSOR E E E 60 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 10 E E E IEXISIRNG TELCO FAN 180 -- 0 20 1/2" #12 2 RECEPTACLE IN TELCO _ 1080 400 EXISTING LIGHT GEN RECEPT SPACE SPACE SPACE SPACE E E - — — — E E - — — — E E - — — — 20 30 - — — — 70 - - - SPARE - 2200 - - - _-- 100 E E E EXISTING MMBTS CABINET 9600 _ 9600 — — — — SPACE — — — — — SPACE —_ - ---- ___ - EE -_ SPACE SPACE — — — — — — — — — — — SPACE - — — — — SPACE - - _ — — — SPACE - ---- - SPACE — — — — — — — _PACE TOTAL VA: BUS A 10180 BUS B 12880 CONNECTED VA: 23060 AMPERES: BUS A 85 BUS B 107 TOTAL 96 RATED VOLTAGE ❑ 120/208 ■ 120/240 ❑ 277/480 1 PHASE, 31MRE I BRAFH POLES 012 ❑18 1120 024 1330 ❑36 1342 RATED AMPS: ❑ 100 E 200 ❑ 40D I CABINET: SURFACE 11 FLUSH FULL NEUTRAL BUS ■ GROUND BUS ■HINGED ODOR ❑KEYED DOOR LATCH JEFLLOSURE TYPE NEMA-3R BRAFLH DEVICES ❑ FUSED 0 CIRCUIT BREAKER ❑ MAIN LUGS ONLY MAIN 200 ■ BREAKER ❑ FUSED SATCH ALL NEW BREAKERS MUST MATCH EXISTING AIC RATING OF PANEL A/E Consultant: mA MORRISON HERSHFIELD Tun swm um»rairy on», swu ra; RenuWn, F. TeI: ECFILD Fu: B54511.I5Y O STPTE OF FLONP.TCp W'J]BWp U w.,.memwm.anra.om Pm jectMIDWAY ROAD ���y®{ 0 W. MIMI13XC052 r _ P 569DWAY ROAD CwJ�III r FORT PIERCE, FL 34981 Drawing Ti11e: AC POWER DISTRIBUTION Project No. 7160111 11/ LB i02/16 A w Dram By. OIaIVM 6y. $ NOTE: E = EXISTING 1.) PANEL SCHEDULE FOR REFERENCE ONLY. CONTRACTOR SHALL FIELD VERIFY ALL BREAKER POSITIONS AND BREAKERS SHOWN. ` = — - PM Rftim. CMwA Apparel PB PANEL AT PPC POWER CABINET Lowe No, Dro"No. E-1 NOT TO SCALE (BASED ON 22" x 34' PAPER) NOT TO SCALE (BASED ON 11" x 17' PAPER) 0 E-1 s F 1 I 2 I 3 1 4 5 6 . ..�arx.xsm - .@. n wwvA�w � mnunwaro`�'wwwx �omomn®xmmurmiwxnmw amvasmmerrrre'�urear�w.uo�'"rvOiu m I.Im OR eax nm ca no .n�a neaniORECIFiGT10NC1✓EMurv� om w xmsnFlmry a� MOx11EcrN�LL mvwra ('�.91aYCDW wnO:PFOFOr. SOLID BARED TINNED COPPER Profession . 000® CONDUCTOR W/ THERMOWELD o°a® "•!.- 15 °°ooa °000a® 3/8"x3/4" SS BOLT a F r •i:� ANTENNA MOUNTING PIPE EXISTING GROUND BAR bzil 3/8" WASHER qT�- $ ELD.'• 3/8" WASHER //•11 3/8" SS LOCK WASHER V% 3/8" SS NUT frlf�V VV FEED ARG``]` PROPOSED PANEL ANTENNA TYP. GROUND BAR CONNECTION DETAIL ASOERTJISTEFE, E-2 NOT TO SCALE (BASED ON x 34" PAPER) STATE OF ROROA AfSLBt< 11 NOT TO SCALE (BASED ON 11' x 17" PAPER) 0 11/0P/18 15RIM FOR PODar 2 H1/4-20 HEX BOLT OLE LUG A 10/14/1e m FORT�:REVhTV No. Data Action #2 AWG GRN �1/4" FLAT WASHER Client PROPOSED MINI -MACRO RADIO I\ Uwj PRIMARY GROUND BAR/ e`1/4" Sprint METAL ENCLOSURE EXi. TOOTH LOCK WASHER OSDDSPAIMPARMAY rt-T1� / — `4-20 HEX NUT INSTALLATION NOTES: 7 OVER DPARKKANSAS86251 1. SELECT BOLT LENGTH TO PROVIDE A MINIMUM OF TWO EXPOSED THREADS. 2. BURNISH MOUNTING SURFACE TO REMOVE PAINT IN THE AREA OF LUG CONTACT. A/E Consultant #2 AWG SOLID BARE TINNED I I 3. APPLY ANTI -OXIDANT COMPOUND TO MATING SURFACE OF LUG AND WIPE CLEAN EXCESS COMPOUND. COPPER CONDUCTOR 1 I 4. USE SOLID COPPER WIRE AND MECHANICAL 2-HOLE LUG FOR ALL EXTERIOR GROUNDING. /AWG STRANDED' UV RATED / MORRISON FiERSHFIELD JACC COPPER CONDUCTOR GROUND CONNECTION DETAIL vl.°ma°", Rmxa / / / E_2 rn.ausnuss F.._asasn.wse sTAyEOF^ RNACWTL / NOT TO SCALE (BASED ON 22' x 34• PAPER) . o-n.o�nrvas.nmm / NOT TO SCALE (BASED ON 11' x 17' PAPER) Pm1ect.MIDWAY I ROAD 6 M113XCO52 p 0'00 CONDUIT COUPLING STRAPPED 5690 W. MIDWAY ROAD oea°°o0a °°000eB000ea TO UNISTRUT ANCHOR TO PAD FORT PIERCE, FL 34981 CONDUIT Drawing Title: EXISTING ANTENNA ANTENNA SECTOR GROUND BAR P1000 UNISTRUT GROUNDING PLAN & (12LONG) (TYP) GROUNDING DETAILS _ (2) 7/8"e HILT] KWIK BOLT III ROB EXPANSION ANCHOR W/ 7160111 1-5/8" MIN. EMBED. 18 EXISTING SLAB FILE CC PY r.COOR AW.1 TYPICAL GROUNDING DIAGRAM TYP. CONDUIT SUPPORT DETAILS P6 b.uw No. OrmMq Na E-2 NOT TO SCALE (BASED ON 22" x 34" PAPER) E-2 NOT TO SCALE (BASED ON 22" x 34" PAPER )-� NOT TO SCALE (BASED ON 11" x 17" PAPER) NOT TO SCALE (BASED ON 11" x 17" PAPER) 0 C v 6 ww.www°aw.wvm 1 2 13 T 4 5