Maschmeyer is pleased to submit the following concrete mix designs for the above referenced project.
Product Code
Design Strength
Ma Description
Sec slunip
Usage
Notes
35050000
3500
3500 PSI Re
5 + -1
Sidewalks
40DS0000
4000
4000 PSI Reg
5 +/-1
Light pole base,
sidewalk, dumpster
ad
35E5W000
3500
3500 PSI Extruded
1.5 +/- 1.5
Curb
Curb
The delivered concrete Will be available at the specified slump range for 30 minutes after jobsite arrival,
or initial slump adjustment, whichever is later, as per ASTM C94-17 Standard Specification for Ready
Mixed Concrete, Section 7.2.
Please note that the concrete plastic properties, of slump and air content, are designed to be
measured from the truck chute, as Maschmeyer Concrete has no knowledge of the intended
placement equipment or expected job conditions at the time of the receiving a request for project mix
design submittals.
Maschmeyer has no knowledge or authority regarding where the mixes are to be placed. Therefore, it
is the responsibility of the project architect, engineer, and/or contractor to insure that the above
designed mix parameters of compressive strength, water -to -cement ratio, cement content and air
content are appropriate for the emironmental exposure and service conditions (.e. ACI-318 Chapter 4
Durability Requirements, and local Building Codes).
The cemenlitious content is stated as a minimum. Maschmeyer Concrete reserves the right to
increase the quantity, and to adjust the aggregate weights to maintain design volumes.
ACI 318-14, Building Code Requirements for Structural Concrete, Section 26.12.1.1 e, and ASTM
C94-17, Standard Specification for Ready Mixed Concrete section 6.8, both specifically require that
the concrete producer/manufacturer be copied on all third party (independent laboratories) test
concrete reports delivered to the project, in a timely manner.
It is Maschmeyer policy to be placed on the concrete test report email distribution list, for ongoing
statistical analysis, to ensure product quality, and compliance with project specifications.
Actual admixture dosage rates may vary and are dependent upon ambient and concrete temperatures,
and weather conditions.
Plastic properties of concrete may vary depending on ambient temperatures, weather conditions,
placement procedures, and types of placement equipment used on the jobsite.
Water addition, in excess of the job site allowable water, will lower strength and is not recommended.
Maschmeyer Concrete is not responsible for any problems associated with excesshe water addition or
poor placement practices.
ACI 302.1 R-04, Guide for Concrete Floor and Slab Construction, ACI 224R-01 Control of Cracking in
Concrete Structures, and ACI 224.3R-95 Joints in Concrete Construction, proWe valuable information
for the concrete contractor and finisher, to help reduce the occurrence of random cracking in the
concrete structure.
Should the project specifications require air content for air entrained concrete to be tested at point of
placement, Maschmeyer Concrete reserves the right to make any necessary adjustments in the field,
as permitted and stated in ASTM C94-17 Standard Specification for Ready Mixed Concrete, Section
8.3.
Please inform the project concrete finisher of any mix designs containing air entrainment o%er 3%
requiring a smooth trowel finish, so proper finishing techniques are used to amid delamination of the
surface.
Thank you for giting us this opportunity to be of service to you. Please feel free to contact me if you
should need any further assistance.
Sincerely yours,
Richard Lorenz
Director of Technical Services
1 - M A SCHMEYE F _"'
Concrete Mb( Design Submittal
Date: 04/1212018 No. 18-P-000244 Version 1
Mix Cade : 35060000 Description: 3500 PSI Reg
Customer C.J.R. CONCRETE INC
Office Phone 386-804-2834
Usage/Placement Sidewalks
Design
Tolerance
Air Content
3
0-3
Slump
5+/-1
4to6
Design Strength
3500
psi
Unit Weight
140.8
Ib/ft3
WIG Ratio
0.55
Material
Type
a
Description
Source Supplier
Standard
Design
Quantity
Specific
Gravity
Volume
(ftl)
Cement
CEMENT -TYPE 141
Comex-FDOT CMP 24
ASTM C150TYPE 1/II
3901b
3.15
1.98
Fly Ash
TYPE F
Boral-FDOT FA 20
ASTM C618 TYPE F
1001b
2.41
0.66
Coarse Aggregate
57DOT
Cemex-FDOT87-090
ASTM C33/FDOT e01
17601b
2.48
11.37
Fine Aggregate
NATURAL SAND
Cemex-FDOT 16-078
ASTM C33/FDOT e02
12501b
2.63
7.62
Water
WATER
Well -Water
ASTM C1602
32.5 gal
1.00
4.34
Admb(ture
I WRDA 64
GCPApplied Technoligles-USA
ASTM C494 TYPED
20lq oz
-
-
Admc(ture
DAREXAEA
GCPApp lied Technoligies-USA
ASTM CX0 A.E.A.
11q oz
-
-
Air Content
3.00 %
—
0.80
Yield
3771 lb
—
27
Prepared By:
Richard Lorenz Director of Technical Services
STRENGTH PERFORMANCE REPORT for 36050000
Mix - 35050000 - 3500 REG
1 33411
Specified Strength
3500
Strength Type
Conpressive Test
28 Day
Number of Tests
28
Over Design Type
ACI 31815-29 Tests
Within Test CofV Factor
1.829
Average Strength
4740
SO Correction Factor
1.012
Within Test SO
110
Standard Deviation
300
Corrected SO
300
Within Test CofV
2.32
Degree of Control
EXCELLENT
Corrected CofV
6.4
Within Test Cold Control
EXCELLENT
Coefficient of Variation
6.3
f'c+1.34•a
3910
Batch -to -Batch SO
280
f'c+2.33•s-600
3710
Batch -to -Batch CcIV
5.89
Required Strength
3910
Cementitious Content
Max'ml um fcfor Mix
4330
Safety Factor
830
Cem antitio us HfMen cy
Slump
Air Content
70 Str
Strength280
in
%
psi
psi
Count
28
28
26
28
Average
5.15
1.50
3100
4740
STDEV
0.66
0.42
340
300
COV%
12.8
28.0
11.1
6.4
Range Mn
4.00
2560
3910
Range Max
7.00
2.10
3740
5370
#
MxCode
Slump
in
Air Content
%
7D Sir
psi
Strength28D
psi
1
35050000
4.50
1.10
2630
4380
2
35050000
5.00
1.30
2960
4560
3
35050000
5.00
1.50
2960
4830
4
35050000
4.00
3260
5130
5
35050000
5.00
1.40
2630
4450
6
36050000
5.00
1.50
2830
4870
7
35050000
5.00
1.00
2800
4640
8
35050000
5.50
1.50
2950
4640
9
35050000
5.00
1.10
2580
4510
10
35050000
5.00
1.40
4920
11
35050000
5.00
1.40
3090
4590
12
35050000
5.00
1.60
3080
4850
13
35050000
4.00
1.90
3120
4880
14
35050000
1 5.25
1.80
3420
5050
15 '.
35050000
5.50
1.90
3170
4900
16 '
36050000
7.00
2.10
3140
4350
17 •
35050000
5.50
1.70
3740
4990
18
35050000
4.50
1.70
2980
4480
19
35050000
4.50
1.90
3160
4870
20
36050000
4.25
1.80
3630
4950
21
35050000
5.25
1.00
2920
4460
22
35050000
5.50
2.00
2946
4400
23
35050000
1 6.50
1.20
2560
3910
Dale: 716/2016 Page 1 of 2
1 33411
STRENGTH PERFORMANCE REPORT for 35050000
Mix : 35050000 - 3600 REG
9
64x Code
Slump
in
Air Content
%
7D Sir
psi
Strength28D
psi
24
35050000
5.76
1.60
3350
4890
25
35050000
5.75
1.70
3670
5070
26
35050000
5.50
1.80
3510
4810
27
35050000
5.50
1.60,
3610
5370
28
35050000
5.00
1.50
4920
Date: 7/6/2016 Page 2 of 2
- MASCHMEYER
Ate!
Concrete Mix Deslgn Submittal
Date: 04/12/2018 No. 18-P-000244 Version 1
Nix Code: 40050000 Description: 4000 PSI Reg
Customer C.J.R. CONCRETE INC
Office Phone 386-804-2834
Usage/Placement Light pole base, sidewalk, dumpsterpad
Design
Tolerance
Air Content
2.5
0-3
Slump
5+/-1
4to6
Design Strength
4000
psi
Unit Weight
142.1
Ib/R3
WIC Rafio
0.50
Material
Type
scription
Description
Source Supplier
Standard
Quantity
Specific
Gravity
Volume
(ft3)
Cement
CEMENT -TYPE 101
Cemex-FDOT GMT 08
ASTM C150 TYPE 1111
425lb
3.15
2.16
Fly Ash
TYPE F
Boral-FDOT FA 20
ASTM C618 TYPE F
105 lb
2.41
0.70
Coarse Aggregate
57DOT
Cemex-FDOT87-090
ASTM C33/FDOT 901
1750 lb
2.48
11.31
Fine Aggregate
NATURALSAND
Cemex-FDOT 16-078
ASTM C331FDOT 902
1265 lb
2.63
7.71
Water
WATER
Well -Water
ASTM C1602
32.0 gal
1.00
4.28
Admuture
WRDA 64
GCPApplied Technoligies-USA
ASTM C494 TYPED
221q oz
-
-
'
Aircontent
2.50 %
—
0.67
Yield
3812 lb
—
27
Prepared By:
Richard Lorenz Director of Technical Services
Southeast
971 Pike Rd
West Palm Beach, FI 33411
Tel:
Laboratory: Southeast -Southeast
Properties
2500-6000 PSI 20% Flyash #57 Natural Sand
Plant:
Test Age : Cement: CEMENT -CEMENT -TYPE 1111 Aggregate Blend :
Nominal Air: 01,00 Cement Supplier: Cemex -FDOT CMT 08 Aggregate Size:
Nominal Slump : 0.00 in Addftion : % Aggregate Type:
2500-6000 PSI20% Flyash#57 Natural Sand
11,000
1 1
1 1 1 1 1 1 1 I 1
9,000
1 1 1 1 1 1 1
8,000 _ t__i__ __L_ __l__1_ _
7,000 ' 1 1 1 1_ , 1
m 6,000 _ r 1 1 1 1 1 1 _ _1_ _
1
4,000
1 1 I 1 1 I 1 1
3,000 __!___1___!__--- __!______ _____-___e
1 1 I I 1 1
2,000 1 1 1 1 1 1 1 1
0.3 0.35 0.4 0.45 0.5 0.55 0.6 0.65 0.7 0.75 0.8
Water/Cement
Sample#
I Sample
Date
I Mix Code
MbrDescriptron
WIC
I Slump
I Air%
Specimen
ID
Age
(days)
Strength
(Pat)
I Average
(Psi)
25050000
2500 PSI Regular
0.65
3070
30D50000
3000 REG
0.67
4230
35050000
3500 REG
0.55
4570
40050000
4000 REG
0.50
5640
50050000
5000 REG
0.46
6470
60050000
6000 REG
0.40
7210
Richard Lorenz
i
Data : 04/20/2017
a ,
#'� b F MAS.CHMEYIER_
Concrete Mix Des Ign Su bm Ittal
Date: 04/12/2018 No. 18-P-000244 Version 1
Mix Code: 35ESW000 Description: 3500 PSI Extruded Curb
Customer C.J.R. CONCRETE INC
Office Phone 386-804-2834
Usage/Placement Curb
Design
Tolerance
Air Content
4.5
3 to 6
Slump
.5+/-1.5
03
Design Strength
3500
psi
Unit Weight
140.9
Ib/it3
W/C Ratio
0.46
Material
Type
Description
Source Suppler
Standard
Design
quantity
Specific
Gravity
Volume
(ft3)
Cement
CEMENT-TYPEIIII
Cemex-FDOTCMT08
ASTM C150 TYPE U11
4801b
3.15
2.44
Fly Ash
TYPE F
Boral-FDOT FA 20
ASTM C618 TYPE F
851b
2.41
0.57
Coarse Aggregate
89D0T
Cemex-FOOT 87-090
ASTM C33/FDOT 901
12201b
2.48
7.88
Fine Aggregate
NATURN_SAND
Cemex-FDOT 16-078
ASTM C33/FDOT 902
17301b
2.63
10.54
Water
WATER
Well -Water
ASTMC1602
31.0gal
1.00
4.14
Admixture
iWRDA 64
GCP App lied Technolig ies- USA
ASTM C494 TYPED
21lq oz
-
-
Admixture
DARE%AE4
GCP App lied Technolig ies- USA
ASTM C260 A.E.A.
51q oz
-
-
AtrContent
4.50 %
—
1.21
Yield
3774 lb
—
27
Prepared By:
Richard Lorenz Director of Technical Services
I
�CC��AV
Miami Plant
1200 NW 137th eve
CEMENT
MILL
Miami, Florida.33182
TEST
�••1
Phone (305) 229-2925 l FAX (305)
229-8015
REPORT
Cement Iiferdifted as:
Typed Low Alkali (MH) and Type If Low Alkali (MH)
Data al Report: 02112n8
Production Period:
Beginning: Wan48
Ending: 314on-18
Silos: 21,22,23,25,31,32,33,35,41i42,43,44,45,51,5753,54,55,56,65,66
CHEMICAL REOUIRMENTS
7usl RCsuUs
M Spedgcul mis: ti lO MM ASTM 1150
A51xIC-115?
ASTM C114and,AASHTO 1486
ipw lLewaWu
rrr•s nl.awatsxu
lvacaiam
od
Silicon Dioxide'(SIO2) %
20.3
Minimum
-
---.
•-
-
Aluminum Oxide (A1203) %
4.7
Maximum
-
so
6,0
---
Ferric Oxide (Fe203) %
3.6
Maximum
-
6.0
6.0
---
Calcium Oxide (CaO) %
64.6
-.
--
--
Magnesium Oxide (MgO) %
0.9
Maximum
6.0
6.0
6.0
Sulfur Tdoxide (S03) % A
2.8
Maximum
3.5
3.0
310
-
Loss on Ignition (LOI) %
2.8
Maximum
3.5
9.5
3.5
••-
Insoluble Residue (IR) %
0.67
Maximum
1,5
1,5
1,5
Alkalies (Na2O (Na2O equivalent) '%
0.35
Optional Max
0.60
0.60
060
--•
- Carbon Dioxide In cement (CO2)%
1.60
Limestone % in cement (ASTM C150 At)
3.8
Maximum
5
5
5
---
CaCO3 (n.limeslone % (2274 x %CO2 LS)
90
Minimum
70
70
70
Inorganic Processing Addition (note 1)
('Bag house Dust") (up to %)
2.2
Maximum
5
5
5
or (°GBFS°) (up to %)
0.0
Maximum
5
5
5
Potential Phase composition e
Tricalcium Silicate (C3S) %
63
-
-
-_,
..
Dlealcium Silicate (C2S) %
11
-
--
--••
Tricalcium Aluminate (C3A) %
7
Maximum
•-
8
8
-•-
Tetracalcium Aluminoferrile, (C4AF) %
11
----
-
-
(C3S+4.75 C3A)
96
Maximum
-
-
100
-
PHYSICAL REQUIRMENTS
4040
Minimum
2600
2600
26GO
•.-•
TM 204)ame neness, cm g
(ASTM C204) Blaine Fineness, cm219
Maximum
--
-•-
43000
--
(ASTM C191) TimeofSetting (Ucal)
Initial: Set, minutes
110
Min/Max
451375
451375
45/375
451420
Final Set. minutes
165
(ASTM C185)Air Content of Mortar %
7.2
Maximum
12
12
12
----
(ASTM C151) Autoclave Expansion %
0.09
Maximum
0,80
0.80
o8o
0.60
(ASTM C187) Normal Consistency %
27.1
-•
-
-•-
---
(ASTM C430) Passing No, 325 Sieve %
98.7
(ASTM C188) Density glcnl3
3.15
for information
(ASTM C1702) Heat of Hydration/Calodmetry Jrg
251
for information
'(ASTM C109) Compressive Strength, psi (Mpa)
1 Day
2210 ( 15.2 )
^-
--••
--^
3 Days
3820 ( 26.3 )
Minimum
1740 (12-0)
1450 (10-0)
1450 (10.0)
1890-(13,0)'
7 Days
4700 ( 32.4 )
Minimum
2760 (19,0)
2470 (17,0)
2470 (17.0)
2900 (20.0).
28:Days °
6260 43.2 :
.. Minimum
V.-
---
--•
.4D60 (28,0)-.
Note 1: The cement produced during this period conlaincel Inorganf6Processing Addition such as Bag house Dust or Ground Granulated Sfag,up to the percentages shown,
A Aspprnole Dorubbai,. S03"lmay uxSeedadde $VatyleaxpamlW Ba ir%OWASTMC10304. p020
e Diane limits doe's not apply If Sum of CM • 4,75• CIA <= 00
C Test results for this period not riva8ade. Most recent teat result proxIcal
D Adjusted par A Is of ASTM C150
Required only it S03 exceeds funk of table.1 of ASTM C150,
This Go ment contains Limestone and may contain Inorganic processing addlion up to the
percentages shown above,
Cemex hereby canines riot Ibis cement noels or exceeds the chemical and physical specificsilans of most recent edition of:
x AASHTO M 65 Type l and Type ll and ASTM C160 Type l and Type 11
)
x AAS14TO M 85 Type II (MH) and ASTM Cf 50 Type 11 (MH)
F��
x ASTM C•1157 GU
/
j
% Flodtla 6peca2l
�/- j
o ,44, y C. axcmeo -
Oi .Jlly Gen IManagar
Wecodifyct that described tlamrepresents thecementatmay
tured theproductionuse
indented-
i
�L.-
r1haabove
be this
Cemei is Imf responsible for mo Improper use W rrorxmansNp that may be associated with Itie use of this cement,
ADDITIONAL DATA
ADDITIONAL DATA
Inorganic Processing
Addition (BHD)
InomainclPr"oce"scing
Addition (GBFS) Base Cement Phase Composition' '
:.viol m �.
Materials Testing & Research Facility
2650 Old State Hwy 113
Taylorsville, GA 30178
770-684-0102
ASTM C618 / AASHTO M295 Testing of
Orlando Utilities Fly Ash
Sample Date: November 2017 Report Date: 1/11/2018
Sample Type: Monthly MTRF ID: 3466OU
Sample ID:
ASTM Limit AASHTO Limit
Chemical Analysis
Results
Class F/C
Class F/C
Silicon Dioxide (Si02)
49.51
%
Aluminum Oxide (AI203)
19.91
%
Iron Oxide (Fe203)
18.18
%
Sum (Si02+AI203+Fe2O3)
87.60
% 70.0/50.0 min
70.0/50.0 min
Sulfur Trioxide (S03)
1.76
% 5.0 max
5.0 max
Calcium Oxide (CaO)
3.60
%
Magnesium Oxide (MgO)
0.72
%
Sodium Oxide (Na20)
0.68
%
Potassium Oxide (K20)
2.30
%
Sodium Oxide Equivalent (Na20+0.658K2O)
2.19
%
Moisture
0.15
% 3.0 max
3.0 max
Loss on Ignition
2.34
% 6.0 max
5.0 max
Physical Analysis
Fineness, % retained on 45-um sieve
14.76
% 34 max
34 max
Strength Activity Index - 7 or 28 day requirement
7 day, % of control
87
% 75 min
75 min
28 day, % of control
78
% 75 min
75 min
Water Requirement, % control
100
% 105 max
105 max
Autoclave Soundness
0.00
% 0.8 max
0.8 max
Density
2.43
Boral Resources certifies that pursuant to current ASTM C618 protocol for testing, the test data listed herein was
generated by applicable ASTM methods and meets the requirements of ASTM C618 and Florida DOT 929
specification.
,oug R� hgdes,CET'.
FacilityManaiier
'xccw ca rteo