HomeMy WebLinkAboutNOA6uANNED
MIAM4DADE �;f. Lude CoUntV MIAMI_DADE COUNTY, FLORIDA
• PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) vvvvw.miamidade.eov/economy
PGT Industries, Inc.
1070 Technology Drive,
North Venice, Fl. 34275
.SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami —Dade County RER—
Product Control Section to be used in Miami —Dade County and other areas where allowed by the Authority
Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami —Dade County Product
Control Section (In Miami —Dade County) and/ or the AHJ (in areas other than Miami —Dade County) reserve
the right to have this product or material tested for quality assurance purposes. If this product or material
fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ
may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction.
RER reserves the right to revoke this acceptance, if it is determined by Miami —Dade County Product
Control Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code, including the High VelocityHuuic_ ea1� Zone.
AESCRIPTION:
APPROVAL DOCUMENT: Drawing No. PGT0004, titled "Series 770 H.P. Aluminum SGD — L.M.I.",
sheets 01 through 10 of 10, dated 08105/07, prepared by manufacturer, revision "F" dated 05/05/16, signed
and sealed by Anthony Lynn Miller, P. E., bearing the Miami —Dade County Product Control Section
Revision stamp with the Notice of Acceptance number and expiration date by the Miami —Dade County
Product Control Section.
MISSILE IMPACT RATIN: Larg and Small Missile Impact Resistant
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state,
series, and following statement: "Miami —Dade County Product Control Approved", unless otherwise noted
herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an endorsement
of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure
to comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami —Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 15-0106.08 and consists of this page 1 and evidence pages E-1, E-2 and Ir3,
as well as approval document mentioned above.
The submitted documentation was reviewed by Jorge M. Plasencia, P.E.
NOA No. 16-0629.07
Expiration Date: March 24, 2020
ol'u'iol� Approval Date: August04,2016
Page 1
PGT Industries, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
A. DRAWINGS
1. Manufacturer's die drawings and sections.
2. Drawing No. PGT0004, titled "Series 770 H.P. Aluminum SGD — L.M.I.", sheets 01
through 10 of 10, dated 08105/07, prepared by manufacturer, revision "F" dated
05/05/16, signed and sealed by Anthony Lynn Miller, P. E.
B. TESTS
1. Reference Test report on 1) Uniform Static Air Pressure Test, per FBC, TAS 202-94
2) Large Missile Impact Test per FBC, TAS 201-94
3) Cyclic Wind Pressure Loading per FBC, TAS 203-94
Along with marked -up drawings and installation diagram of Aluminum Sliding Glass
Doors (w/ PS, Super, Cardinal & Duraseal Spacers), prepared by Fenestration Testing
Laboratory, Inc., Test Reports No(s) FTL-8717, FTL-8970 and FTL-8968, dated
02/15/16, 06/07/16 and 06/20/16, all signed & sealed by Idalmis Ortega, P.E.
2. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
6) Forced Entry Test, per FBC 2411.3.2.1, and TAS 202-94
along with marked —up drawings and installation diagram of Aluminum Sliding Glass
Door (XOX), prepared by Fenestration Testing Laboratory, Inc., Test Report No.
FTIr7825, dated 06/10/2014, signed and sealed by Idalmis Ortega, P. E.
(Submitted under previous NOA No. 15-0106.08)
3. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
6) Forced Entry Test, per FBC 2411.3.2.1, and TAS 202-94
along with marked up drawings and installation diagram of Aluminum Sliding Glass
Doors (Samples A-1, A-2, B-1, B-2 and C-1), prepared by Fenestration Testing
Laboratory, Inc-, Test Report No. FTL-7468, dated 09/13/2013, signed and sealed by
Martin D. Brinson, P. E.
(Submitted under previous NOA No. 13 1009.07)
Jorge M. Plasencia, P. E.
Product Control Unit Supervisor
NOA No. 16-0629.07
Expiration Date: March 24, 2020
Approval Date: August 04, 2016
E-1
PGT Industries, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
B. TESTS (CONTINUED)
4. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
6) Forced Entry Test, per FBC 2411.3.2.1, and TAS 202-94
along with marked —up drawings and installation diagram of Aluminum Sliding Glass
Doors (Samples A-1, A-2, B-1, B-2 and C-1), prepared by Fenestration Testing
Laboratory, Inc., Test Report No. FTL-5998K dated 12/29/09, revised, signed and
sealed by Julio Gonzales, P. E.
(Submitted under previous NOANo. 09-0826.12)
5. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
6) Forced Entry Test, per FBC 2411.3.2.1, and TAS 202-94
along with marked —up drawings and installation diagram of Aluminum Sliding Glass
Doors (Samples A-1, A-2, B-1, B-2 and C-1), prepared by Fenestration Testing
Laboratory, Inc., Test Reports No.'s FTL-5998, FTL-6005 and FTI-6012, dated
08/10/09, all signed and sealed by Julio Gonzales, P. E.
(Submitted under previous NOA No. 09-0826.I2)
6. Additional reference supporting Test Reports No.'s ATI72138.01-401-18 and
FTL-5254.
C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with FBC 51
Addition (2014), prepared by manufacturer, dated 03/05/15, signed and sealed by
Anthony Lynn Miller, P.E.
(Submitted underprevious NOA No. 15-0106.08)
2. Glazing complies with ASTM E1300-04109
D. QUALITY ASSURANCE
1. Miami —Dade Department of Regulatory and Economic Resources (RER).
Jorge M. Plasencia, P. E.
, ,-,duct Control Unit Supervisor
NOA No. 16-0629.07
Expiration Date: March 24, 2620
Approval Date: August 04, 2016
E-2
PGT Industries, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 14-0916.10 issued to Kuraray America, Inc. for their
"Kuraray PVB Glass Interlayer" dated 03/12/15, expiring on 12/11/16.
F. STATEMENTS
1. Test proposal No. 16-0152 dated 03/09/16 approved by RER.
2. Lab compliance as part of the above referenced Test Report No(s) FTL-8717, FTL-
8970 and FTL-8968.
3. Statement letter of conformance to and complying with FBC S 1 Edition (2014), issued
by manufacturer, dated 12/31/14, signed and sealed by Anthony Lynn Miller, P. E.
(Submitted under previous NOA No. 15-0106.08)
4. Laboratory compliance letter for Test Report No. FTL-7825, issued by Fenestration
Testing Laboratory, Inc., dated 06/10/14, signed and sealed by Idalmis Ortega, P. E.
(Submitted under previous NOA No. 15-0106.08)
5. Laboratory addendum letter for Test Report No. FTL-7468, issued by Fenestration
Testing Laboratory, Inc., dated 01/13/14, signed by Manny Sanchez, CEO.
(Submitted under previous NOA No. 13 1009.07)
6. Laboratory compliance letter for Test Report No. FTL-7468, issued by Fenestration
Testing Laboratory, Inc., dated 09/13/13, signed and sealed by Martin D. Brinson, P.E.
(Submitted under previous NOA No. 13-1009.07)
7. Proposal, dated 06/04/13, issued by the Product Control, signed by Jaime D. Gascon,
P. E.
(Submitted under previous NOA No. 13-1009.07)
8. Laboratory compliance letter for Test Reports No.'s FTL-5998, FTL-6005 and
FTL-6012, all issued by Fenestration Testing Laboratory, Inc., dated 08/10/09, signed
and sealed by Julio Gonzales, P. E.
(Submitted under previous NOA No. 09-0826.12)
9. Proposals No.'s 09-0177-A, dated 05105109, B, dated 05/27/09 and -C, dated
05/27/09, all issued by the Product Control, signed by Ishaq Ghanda, P. E.
(Submitted under previous NOA No. 09-0826.12)
G. OTHERS
1. Notice of Acceptance No. 15-0106.08, issued to PGT Industries, Inc. for their Series
"770-BP Aluminum Sliding Glass Doors w / Reinforcements - L.M.I.", approved on
03/12/15 and expiring on 03/24/20.
Jorge M. Plasencia, P. E.
roduct Control Unit Supervisor
NOA No. 16-0629.07
Expiration Date: March 24, 2020
Approval Date: August 04, 2016
E-3