HomeMy WebLinkAboutPLANS 1FLOOR PLAN -REASR-COVE "— �oitLVEsy3' 4100 N. HIGHWAY A1A LEGEND: A 6'3' B,-Y_6.8" SLIDING GLASS DOOR B 6'3" BY 8'0" SLIDINGGLASS DOOR I@/ 8'3" BY 8'0' SLIDING GLASSDOO.- + %_ MINIMUM DESIGN PRESSURE xx IN POUNDS PER SQUARE FOOT OUANNED BY ,t I UCia County i IN ENGINEERING. INC. O ' FL., "S� JANUARY 20, 2017 1835 20N Sveer JOB NO. 21 VERO BEACH, FL 32960 DES7GNE0 TS PH. (772) 569-0035 OBAWN A R FX. (772) 778-3617 DATE JAN 2 FL Pierce, FL IWmwr ... WIND SPEED MPH) DJ)=12— a V(� 65 R*(,ATEGO� I f EXPoSURECATEGORY� D ENCCOSURECLASSIFICATION ZE:NCLOSED ou/iIVIVtL, —INTERNAL PRESSURE COEF.I M-0:18: Br TOPOGRAEHIC-FACTOR XZY70 �t �UCia rntintT GENERAL REQUIREMENTS 1. THE DESIGNAND CONSTRUCTION OF THISPROJECTIS GOVERNED BY THE°FLORIDA BUILDING CODE (FBC)-, BUT EDITION, HEREAFTER REFERRED TO AS THE FBC, ASADOPTEDAND MODIFIED BY THE AUTHORITY HAVING JURISDICTION (AHJ). 2. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING DETAILS AND ACCURACYOF THE WORK WITH ENGINEER AND OTHER TRADES, FOR CONFIRMING AND CORRELATINGALL QUANTITIESAND DIMENSIONS; FOR SELECTING FABRICATION PROCESSES; FOR TECHNIQUES OFASSEMBLY,' AND FOR PERFORMING WORK IN A SAFE AND SECURE MANNER. 3. THE STRUCTURAL DRAWINGS ARE INTENDED TO SHOW THE GENERAL CHARACTER AND EXTENT OF THEPROJECTANDARENOT INTENDED TO SHOW ALL DETAILS OF THE WORK. 4. DISCREPANCIES,OMISSIONS, OR INCONSISTENCIES WITH APPLICABLE CODE REQUIREMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER IN WRITING BEFORE SUBMITTING A BID OR PROCEEDING WITH THE WORK. 5. THE CONTRACTOR SHALL VERIFYALL DIMENSIONS AND CONDITIONS AT THE SITE. CONFLICTS BETWEEN THE DRAWINGS AND ACTUAL SITE CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER IN WRITING BEFORE PROCEEDING WITH THE WORK. STRUCTURAL CERTIFICATION 1. 1 CERTIFY THAT THEPLANS AND SPECIFICATIONS COMPLYWITH THE STRUCTURAL PORTION OF THEFLORIDA BUILDING CODE FIFTH EDITION. 2. IALSO CERTIFY THAT STRUCTURAL ELEMENTS DEPICTED ON THESE PLANS PROVIDEADEQUATE RESISTANCE TO THE WIND LOADS SPECIFIED IN SECTION 1609 IN THEFSC. DOORS NOTES 1. THE DESIGN PRESSURES FOR THE DOORS SHALL BE NOT LESS THAN THE VALUES SHOWN ON THE PLAN, 2. THE DOORS SHALL BE INSTALLED IN STRICT COMPLIANCE WITH THE MANUFACTURER'S NOTICE OFAPPROVAL(MIAMI NOA OR FBC APPROVAL). 3. THE DOORS MUST WITHSTAND THE IMPACT OF WIND BORNE MISSILES, OR SHALL BE PROTECTED WITH AN APPROVED IMPACT RESISTANT COVERING. 4. EACH UNIT SHALL BEAR LIBEL WITH THE MANUFACTURER'S NAME AND DESIGN PRESSURES. S. PRIOR TO INSTALLATION, ALL FRAMES MUST BE CHECKED FOR RACK, TWIST AND OUT OF SQUARE. 6. FOLLOW FMA(FENESTRATION MANUFACTURERS ASSOCIATION) GUIDELINES FOR FLASHING ALL OPENINGS. a. CAULKALL INSIDE CORNERS OF OPENINGS WITHANAPPROVED SEALANT. b. APPLYANAPPROVED FLASHING TO ALL FOUR SIDES OF OPENINGS. c. APPLYA HEAVY, UNINTERRUPTED BEAD OFAPPROVED SEALANT TO THE BUCKS PRIOR TO ATTACHING TO THE OPENING PER WINDOW/ DOOR DETAILS. D. SEAL BUCKS W/THANAPPROVED FLASHING MATERIAL e. INSTALL DOOR /WINDOW AND APPLY BEAD OF APPROVED SEALANT AROUND PERIMETER. 7. APPROVED CORROSION RESISTANTFLASHING SHALL REAPPLIED IN SHINGLEFASHION INA MANNER TO PREVENTENTRY OR PENETRATION OF WATER TO THEBUILDINGS STRUCTURAL FRAMING COMPONENTS 8. SELF -ADHERED MEMBRANES USEDAS FLASHING SHALL COMPLY WITH AAMA 711. THEFLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH. fA P.O BUCK AN0K S PER SORDUL& MATCH DISiDm WSMTION W UOUID SCTEW MIN SEALANT AND FINISHES RASIDIG RR FBC / PROU.D CAP W/ BAORR ROD AND SEAIANi FOR CONTINUOUS AIR SEAL. DRIP EDG E FORMID1 ixr � In GAP wi RADON ROD a SEALANT FOR SEa1AF1r fA P.T. BUCK CONTINUOUS METAL w/UQUID SEM.wr tk RAWXG FER MC BACKER ROD STUCCO TO BE RELOVED/REPIACED PER NOIE OPENING WATERPROOFING DETAIL ScvE a/4•- 1•-0 PROCEDURE: (V •`G I. OW STUCCO ALL AROUND INTERIOR JAMB OF OPENING 70 CPOSE C1m AND BUcx z SEAL INID25FCTIO1 OF BUCK TO CMU WINWU" OR EQUAL LE7 CURE: � 3. AOD UQ AD FiASNNG PER FBC 14054 OR FBCR 7018 AS REOnRED. Lu o- , 4. ADD A CONTINUOUS READ OF SEALANT TO THE BUCK AND INSTALL DOORIMNDOw PER ' MANUFACTURERS REQUIR 6MN7S AND H017CE OF APPROVAL / FLCimA PRaoucr APPRovu.- ~ , S AND ADD BONDING AGENT TO EMDdON AREAS PER. MANUFACRWERS ROMRIVENIS Q , O ADD STUCCO PER ASiM C 932 TO MATCH DUSTING OPENINGS i 4[ % 7. PRAX AND PAIR MTU APPROVED COMINGS TO MARK EATSTING COLORS AND FINISHES u PRODUM � AWNG SHALL BE PROTECTO MRAP LNN20 WLJmN 35W OR APPROVED EQUAL IFALANTMM BE VULWJ TNT POLIUREINANE BY 7REMOD OF? APPROVED EQUAL BODING AGENT SALL BE 9AIRSTICK AOt11BONI, LANDO OR APPROYID EOUAL FDO�. A\RY 20, 2017 TREASURE COVE DUNES 4100 N. HIGHWAY Al A FL Pierce, FL UNIT 133 SLIDING GLASS DOOR REPLACEMENT NOTES AND DETAILS ' �� 183510th Sve3 ■ VERO BEACH, FL 31960 PH. (772)569-0035 778-3617 l' FX. (771) 778-3617 ENGINEERING, INC. MOIABOWIB�&ASOCLATM WREICR w CON MNGWOINMMNG (AMM hIDBd1RNEA MRTRERCE JOVB~NNUO. S3 DESIGNED TS DRAWN AER DATE JAN 2017 CHECKED TS DATE ISSUED 01/20/2017 SHEET 2 OF 2