HomeMy WebLinkAboutWIND LOAD CALCULATIONSENGINEERING EXPRESS® Order (Ref) #: 26489 (42755-6748958333) ProjeetLESIC �� Contractor: COMPLETE ALUMINUM GENERAL 4100 NORTH HIGHWAY AlA CONTRACTORS FORT PIERCE, FL 1910 BARBER RD SARASOTA, FL S(+ANNED Subject: Wind Load Design Pressure Calculations (Components & Claddinf. ucip rhinjlr Site Information Building Classification: enclosed Wind Speed (V lt): 170 mph Exposure Category: d Roof Type: monoslope Roof Slope (9): 0.0 deg Mean Roof Height (h): 36.0 ft Min. Building Dimension (L): 86.0 ft Parapet >: 3 feet? No General Calculation Directionality Factor (Kd): 0.85 Gust -Effect Factor (G): 0.85 Internal Pressure Coefficient (GC"* ± 0.18 Topographical Factor (K,J: 1.0 Velocity Pressure Exposure Coefficient ( nK): 1.20 Velocity Pressure (qn): 75.44 psf End Zone (a): 8.6 ft ASD Method: P = 0.6w Mark Qty Elev (ft) Size: W x H (in) Zone Shutter? Area (ft') K, (Kh) 4, (A h) GC p+ GCp_ Pressures (psf) corn (2) 36.0 75.0 x 95.8 5 No 49.9 1.20 75.44 0.79 -1.04 +43.9 / -55.1 balc (1) 36.0 75.0 x 79.8 4 No 41.6 1.20 75.44 0.80 -0.89 +44.4 /-48.5 NOTES: Design is in accordance with ASCE 7-10 (Aso method) and the Florida Building Code Fifth Edition (2014). Results are not valid for use unless approved via original signature and raised engineer seal of a PE from Engineering Express. Results are based on contractor -supplied data --and shall be field verified by others prior to use. Selection & installation of products shall be approved using these dimensions and pressures as verified by others. Valid Only WA$ Raised Engineer/ r Fri ' 0 %617 �. PE609%4 C6r Auth 9885 160 SW 12TH AVENUE, SUITE 106, DEERFIELD BEACH, FLORIDA 33442 26489 (42755-6748958333) PHONE: (954) 354-0660 - FAX: (954) 354-0443 AutoPrint ENGINEERINGEXPRESS.COM PAGE 1 OF 1