Loading...
HomeMy WebLinkAboutPRODUCT REVIEW— BY St. Lucie Colin', FFAP multi -refrigerant models; low, medium and high temperature; R-404A, R-134a, R-407C and R-22 Unmatched reliability and efficiency • Improved efficiency from 10%-15% annually • Optimized for multiple applications Diagnostic protection Equipped with electronic unitcontroller: • Troubleshooting diagnostics • System protection • Reduces potential service costs Application flexibility • Operating range of-30OF to 45•F evap (R-404A) • Designed for up to 110* ambient • Designed to workwith multiple refrigerants • Optional hood available Fully featured • Integrated electronic controls • Advanced system protection • Part of the industry's broadest line of integral horsepower condensing units for refrigeration applications O V EMERSOM Climate Technologies Physical and electrical data , CFVTFC,TFD ZS09KAE 24.1 18.3 16.6 7�85 6.4 121FFAP-015Z 4 FFAP-017Z CFV,TFC,TFD ZS11 KAE 24.1 18.316.6 7185 318S 17.2-25 14A-20 7.1-15 6.4 130 FFAP-02OZ CFV,TFC,TFD Z513KAE 25.2 34 19 718S 318S 16.8-25 13.9-20 7.1-15 11.2 191 FFAP-022Z CFV,TFC,TFD ZS15KAE 25.2 34 19 718S 3/8S 22.4-35 16.1-20 10-15 11.2 191 FFAP-030Z CFV,TFC,TFD Z519KAE 25.2 34.1 19 7/8S 3/85 25.3-40 19.9-30 11.3-15 11.2 209 ---- CFV, TFC, TFD Z521KAE 25.2 34.1 19 7j8S 3j85 31r8!,T0' 21.8-30 11.8-15 11.2 209 FFAP-040Z CFV, TFC, TFD ZS26KAE 28.2 44.1 26.8 11j85 1j2S 33.1-50 23-35 11-15 18.7 290 FFAP-042Z CFV, TFC,TFD Z533KAE 28.2 44.1 26.8 1118S 1/2S 38.9-60 31.5-50 14.9-20 18.7 296 FFAP-OSOZ CFV, TFC, TFD, TFE Z538K4E 28.2 44.1 26.8 11j85 1j25 43.4-70 30.4-45 14.4-20 11.9-15 18.7 297 •CFV=single phase, 2081230 volt TFC= three phase, 2081230 volt TFD=three phase, 460 volt TFE=three phase, 575 volt. All models available for use with R-22, R-134a, R404A, R-407C. See OPI forcurrent list of approved refrigerants. Features :• Fan motor E71 Fixed speed -072 Fixed speed L075 Fixed speed Head pressure control Fan cycle Head Pressure Control Valve Refrigerants 404A,134a, 407C 22 404A,134a, 407C 22 404A,134a, 407C 22 Servicevalves Steel Steel Steel Receiver ✓ ✓ ✓ Liquid shut off ✓ ✓ ✓ Moisture indicator ✓ ✓ ✓ Filterdrier ✓ ✓ ✓ Fixed HP ✓ ✓ ✓ Adjustable LP ✓ ✓ ✓ CCH ✓ ✓ Accumulator ✓ Specific models optionalfa.atwes Hood Speciftmodek O15Z 017Z 505-7066-01 020Z-032Z 505-7066-02 040Z 05OZ 505-7066-03 Capacity data ModelE ,,.. FFAP-015Z 11,500 7.540 41 10,400 E .r r. .,,. 11.400 4,000 FFAP-017Z 13,100 8,900 12,500 13.100 5,200 FFAP-020Z 15,300 10,200 14,000 15,200 6,280 FFAP-022Z 18,900 12,300 17,300 18,300 7.360 FFAP-030Z 21,600 14,100 19,700 20,800 8.330 FFAP-032Z 27,300 18,500 25,400 27,400 11,200 FFAP-04OZ 34,200 21,300 30,700 31,700 12,900 FFAP-042Z 40,800 26,100 36,300 38,700 15,800 FFAP-050Z 45,400 29,400 41,600 43,100 16,900 25•F capacities are at 60 Hertzwith 65• return gas and 5°F subcooling. -20°F capacities are at 60 Hertzwith 40° return gas and 5°F subcooling. Emerson' Electronic Unit Controller - Controls unit based on suction Quick & easy set-uppressure F -Fan cycling with mid coiltemperature 1-Improvedset-pointaccuracy - Discharge line protection -Enables multi -refrigerant product -Trouble shooting diagnostics Ju {S (I 0ii 2012ECTi0 R2)09112)Ernemn andCopdand Sodl aretdemarb of Emerson EIectic Cm orwe of Its affiliated m panlm 02012 Emenm Oblate Tedmdogies, Inc All dghtsreserved. Noted In the US&