Loading...
HomeMy WebLinkAboutPLANS.� CONTRACTOR PIONEER SCREEN LLC DESIGN CRITERIA: He ( ipy APPLICABLE CODES, REGULATIONS & STANDARDS: 1.THE 2014 FLORIDA BUILDING CODE, 5TH EDITION SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & CHAPTER 23, WOOD AND AA ASM 35 and AA ADM 1 2. ASCE 7-10. WIND LOADS 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 & TABLE 1604.5: RISK CATEGORY 1. 2. BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION & BASIC WIND SPEED, PARAGRAPH 1609.3.1 & TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEED: 150 MPH EXPOSURE CATEGORY, PARAGRAPH 1609.4.3: D 3. SCREENED ROOF ENCLOSURE TABLE 2002.4 FOUNDATION DESIGN FOOTING SIZE EXISTING CONCRETE SLAB. NO ADDITIONAL FOOTING OR FOUNDATION SYSTEM IS REQUIRED BY THE PROPOSED CONSTRUCTION IF A MINIMUM 4" CONCRETE SLAB IS PROVIDED IN SOUND CONDITION, FREE FROM STRUCTURAL CRACKING, SPALLING & OTHER DETERIORATION. SPECIFICATIONS THE FOLLOWING SPECIFICATIONS ARE APPLICABLE TO THIS PROJECT: 1. WHERE CONCRETE SPECIFICATIONS ARE REQUIRED, WHETHER IN THE SCREEN ENCLOSURE SCOPEOF NOT, BY ONE OR MORE REGULATORY AGENCY, THE FOLLOWING SPECIFICATIONS ARE APPLICABLE: a. CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING COMPONENTS: I. PORTLAND CEMENT TYPE 1 -ASTM C 150 ii AGGREGATES - LARGE AGGREGATE 314 MAX. - ASTM C 33 iii. AIR ENTRAINING +/-1%-ASTM C 260 iv. WATER REDUCING AGENT - ASTM C 494 v. CLEAN PORTABLE WATER vi. OTHER ADMIXTURES NOT PERMITTED b. METAL ACCESSORIES SHALL CONFORM TO: 1. REINFORCING BARS -ASTM A615, GRADE 60 ii. WELDED WIRE FABRIC - ASTM Al85 c. CONCRETE SLUMP AT DISCHARGE CHUTE NOT LESS THAN 3" OR MORE THAN 5". WATER ADDED AFTER BATCHING IS NOT PERMITTED. d. PREPARE & PLACE CONCRETE PER AMERICAN CONCRETE INSTITUTE MANUAL OF STANDARD PRACTICE, PART 1, 2, & 3 INCLUDING HOT WHEATHER RECOMMENDATIONS. a. MOIST CURE OR POLYETHYLENE CURING PERMITTED. If. PRIOR TO PLACING CONCRETE, TREAT THE ENTIRE SUBSURFACE ARE FOR TERMITES IN COMPLIANCE WITH THE FBC. g. CONCRETE SHALL BE PLACED OVER A POLYETHYLENE VAPOR BARRIER 2. ALUMINUM EXTRUSIONS SHALL BE 6005 T5 ALLOY. 3. FASTENERS ARE REQUIRED TO BE SAE GRADE 2 OR BETTER ZINC PLATED. 4. IT IS THE OWNERS RESPONSIBILITY TO MAINTAIN THE SCREENS, FASTENERS AND SCREENS TO MANUFACTURING SPECIFICATIONS. 5. ALL SELF MATING BEAM SECTIONS ARE TO BE STITCHED WITH #12 SCREWS 6" FROM ENDS & 24" CENTER TO CENTER 6. THE MINIMUM NORMAL THICKNESS OF PROTECTOR PANELS (KICKPLATES) SHALL BE AN INDUSTRY STANDARD OF 0.024 INCHES. 7. SCREENED ENCLOSURES CONTAINING SWIMMING POOLS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF FBC R4101.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS. B. SCREEN MATERIAL SHALL BE 18114 SCREEN UNLESS APPROVED BY FLORIDA ENGINEERING LLC. 9. DOOR LOCATION SHALL BE DETERMINED BY CONTRACTOR IN THE FIELD. 10. ROOF BRACING SHALL BE A MINIMUM 2"x2"x.050". 11. WHEN PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK W/3000 PSI GROUT WITH BONDING AGENT 12. WHEN APPLICABLE FOR NEW FOOTER TO EXISTING, DRILL & EPDXY NEW STEEL INTO EX. FOUNDATION WITH 1"MIN. HOLE, EMBED 4" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) TYP. ALL LOCATIONS 13. INTEGRITY OF STRUCTURE SHALL NOT BE COMPROMISED W/ THE ATTACHMENT OF THE PROPOSED STRUCTURE SCALE: NTS JOB NO. 1711022 FREE-STANDING ON EXISTING SLAB 2x8 1x3 = Ln W J U 2x8 SMB 4 VENT SCREEN m SLI ERS 0 M � :h Ch CO d' 5'-0" 5'-0" 5'-0" L 5'-0" 20'-0" 3"x.024"x2LB COMPOSITE PANELS 3105-H14 1/"-1' SLOPE (MIN.) 22'-0" I 2x8 SMB 1x2 1x2 1x2 00 00 - N N -1 ch 2x3 2x3 2x3 1100 KICKPLATE KICKPLATE KICKPLATE -c.,J 1x3 1x3 1x3 6'-8" 6'-8" 6'-8" 20'-0" CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE G0NIRA0T0R OF R613ARA 6L;ANNED BY St. Lucie County THESE PLANS AND ALL PROPOSED WW ARE SUBJECT MANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NEWPARYIN ORDER TO i `COPAPLYWITH ILLhPPLICA®LECODES: W Q J a Y U ►J W g d Y U Y 'k 11�l ANO ST. LITC E COUNTY BUILDT`?O DIVLSION REVIEWED FOR4 O0,Ng LANCE LVII t`� iCjD DATE PLANS AND PERMIT MUST BE I{EPT ON JOB OR NO INSPECTION WILL BV. ==, a ALUMINUM MEMBERS DIMENSIONS ��e HOLLOW SECTIONS ��� 2 X 2: 2"XZ'X0.044" 2 X 3: 2"X3"X0D50" 2 X 4:2"X4"X0D50" ELF -MATING OR Y X 2' PER PLAN 2X 5:2"X5"X0.050" 1/e"X7'X2"XANGLE SNAP SECTION TYP ATTACH TO ROOF PANELS 5OU H-32 ANGL i"X2" O.B. BASE PLATE TYP ROOF PER PLAN W/#122 X 2-12"SMS OPEN BACK SECTIONS 1-0/T MIN. CONC. HOST 1X2'1"X2"X0.044" ALUMINUM INTERNAL OR EXTERNAL (2)-#12 SM ANCHOR EMBEDMENT 1 X 3: 1"X3"X0.045" RECEIVING CHANNEL W/ (4) #10 X.75" MIN 4"SlAB 2500 PSI INTO GIRT OR PURLIN AND (2) 014 X.75' ,. (2)-#12 SMS INTO COLUMN CONC. W/FIBERMES ` SNAP SECTIONS INTO BEAM OR UPRIGHT 0.062 ANGLE ': ,'..:':':: 1/4"MASONRY ANCHOR EACH - 2X2SNAP: 2"X2"XO.045° (4)#10X1.5"SMS INTO SCREW BOSS S CLIPS MAY BE USED "`SIDE VIEW "` ANGLE-E/S COL AL ERNATES FORC" 2 X 3 SNAP: 2"X3'X0.050" (INTERNAL) NO.fE: m TO 2'XZ AT HEADER 2 X 4 SNAP: 2"X4"X0.045" RS PRESENT US 3/6" O COL PER PLAN 1- DETAIL C MASONRWHERE Y ANCHOVERS MASONRY ANCHORS TO PENETRATE tt 2.(4)#10 X3'SMS SELF MATING (SMB) 2)-#12SMS UNDERLYING FOOTING I-12" THROUGH MEMBER VE ADJOINING BEARING WALL% MEMBERCREW 2 X 4 SMB: 2"X4"X0.044"X0.100" PURLIN GIRT 1/4" MASONRY ANCHOR INTO COL S 2 X 5 SMB: 2"X5"XO.050"X0. 100" HEADER OR UPRIGHT, BEAM -SNAP, EACH ANGLE E/S &NOTCH COL TO NE 2 X 6 SMB: 2"X6"X0.050"X0.120" SILL SELF MATING OR HOLLOW BEAM FASTEN W/ (2)Y.'THRU-BOLT 2 X 7 SMB: TX7"X0.057°X0.120" ,.. „. 3 CHAIRRAILPERPLAN 2X BSMB: 2"X8"X0.072"X0.124" 1"X 2"BASE PLATE ANCHORED TO `` h '- m 1"X2"FASTENTO 2X9SMB:2"X9"X0.D72"X0.124" ............ CONC.W/1/4"X21/2'OUICKSET O O ADJOINING WALLW 2 X 10 SMB: 2"X70"X0.092"X0.39W FRONT VIEW W MAX E/S OF POST AND 24" O/C MAX s #12X1-1P SMS CHANNELS FOR ATTACHMENT TO WDIUSE 1/412-12"(MIN)GALV i 1/4"X2-1/4" TAPCONS@24" 19'0/C LAG SCREWS IN LIEU OF MASONRYANCHORS-INCREASE O.C. Tx3.1125"x1.57c045 SYY'xoas GIRT OR PURLIN TO BEAM OR LENGTH TO INSURE PENETRATION INTO UNDERLYING WD FRAMING ' jt POST DETAIL SCALE: NTSLh DETAILA ETA DETAIL 2"X4"OR LARGER SELF MATING UPRIGHT ..................... ................................ ,. TO DECK DETAILS SCALE: NTS EXISTING CONCRETE TYPICAL SIDE WALL DETAIL B SCREEN ROOM END WALL DETAIL: ALTERNATE COLTO CONCRETE SCALE: NTS COVER END PANEL' (2) 1/2" THRU-BOLT FOR COMPOSITE PANELS (#12 x PANEL THICKNESS SMS PLUS 1" LG.) W/ 1-1/2",NEO- WASHER @ 12" O/C PER PLAN ROOF PER PLAN BEAM PER PLAN (2) 1/2" THRU-BOLT SEE ALSO COUEDGE BEAM ALTERNATES COL. PER PLAN _ COL. PER PLAN WHERE MIDPOINT WHERE MIDPOINT COL. IS INDICATED. COL. IS INDICATED CHAIR RAIL PER PLAN FASTEN PER DETAIL C *WHERE PAVERS ARE PRESENT INSURE PENETRATION INTO UNDERLYING CONC. OF 1 1/2" MIN. _WHERE KICK PLATE -IS. INDICATED_ . FASTEN W/ #10 X 9/16" SMS 8" O/C AT PERIMETER FOR COMPOSITE PANELS (#12 x PANEL THICKNESS SMS PLUS 1" LG.) W/ 1-1/2" NEO- WASHER @ 12" O/C / COVER END OF PANEL GUTTER CAGE BEAM ATTACH PER DETAIL G SHEET 3 ALTERNATES FOR DECK ATTACHMENT: SMB -PER DETAIL B SHEET 2 1/8" X 3" RECEIVING CHANNEL (2) 1/4" X 2" QUICKSET INTO CONC. (2) #14 X 9/16" E/S COL. 1/8" X 2 X 2 X COL SIZE ANGLE (2) 1/4" X 2" QUICKSET INTO CONC. (2) #14 X 9/16" E/S COL. U v r J m o DO J UL L rn cco ZZo00 ,_I W_O u) W LL r— Z�wM Z OV-- cy) Q � Q 0 Q U 0 W LL a.LL m J _ Up � J m U Zw J 00 Z UOf w U �OLJL 1nOf m 0 6 w W w O=U Z In 0 � p 1­ 0a a: DEL z Z 0 W Q d I I