ENERGY CONSERVATION CHECK LIST
Florida Building Code, Fifth Edition (2014) - Energy Conservation EnergyGauge Summit® Fla/Com-2015, Effective Date: June 30, 2015 IECC 2012 - Total Building Performance Compliance Option Check List ;LHNNED BY St. Luce Countv Applications for compliance with the Florida Building Code, Energy Conservation shall include: ❑ This Checklist ❑ An Input report generated from the software just after completing compliance calculations without any further changes The full compliance report generated by the software that contains the project IR M01 on cl certifications and detailed component compliance ❑ Boxes appropriately checked in the Nfiscellanous report generated by the software at the end of the compliance report 1T.?t?CiC0U0NTYD / PLAN REVIEW BLDG: G DATE: ELEC: a 7 DATE: -%Z�f / PLUMB: DATE: MECH- DATdzJ-;L-)-1 EnergyGauge Sumrrfa FlaICom-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 1/26/2017 Page 1 of 13 r PROJECT SUMMARY Short Desc: Elks Park Description: Elks Park Owner: St Lucie County Addressl: 25thSt City: Fort Pierce Address2: 25th St State: Fl Zip: 34950 Type: Sports Arena Class: Renovation to existing buildii Jurisdiction: ST LUCIE COUNTY, ST LUCIE COUNTY, FL (661000) Conditioned Area: 1260 SF Conditioned & UnConditioned Area: 1260 SF No of Stories: 2 Area entered from Plans 1260 SF Permit No: 0 Max Tonnage 4405:/ If different, write in: r im ^t J A ✓/ Component Design Criteria Result Gross Energy Cost (in $) 1,114.0 1,223.0 PASSED LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? PASSES No Entry PASSES No Entry No Entry No Entry Yes/No/NA IMPORTANT MESSAGE Info 5009 — -- -- An input report of this design building must be submitted along with this EnergyGauge Summiit0 Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 1/26/2017 Page 2 of 13 CERTIFICATIONS I hereby certify that the plans and specifications cove y this calculation are in compliance with the Florida Energy Code iJ Prepared By' Building Official: Date: cy7 Date: I certify that this building is in compliance with the FLorida Energy Efficiency Code Owner Agent: Date: If Required by Florida law, I hereby certify (') that the system design is in compliance with the Florida Energy Efficiency Code Architect: Reg No: Electrical Designer: Reg No: Lighting Designer: Reg No: Mechanical Designer.Z�2/��� Reg No: Plumbing Designer: Reg No: (') Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. EnergyGauge Summit© FWCom-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 1/26/2017 Page 3 of 13 Project: Elks Park Title: Elks Park Type: Sports Arena 1) Proposed 2) Baseline Total 69.80 90.20 $1,114 $1,439 ELECTPJCITY(MBtulkWhl$) 69.80 90.20 20469 26448 $1,114 $1,439 AREA LIGHTS 6.00 10.50 1770 3097 $96 $168 MISC EQUIPMT 15.80 15.80 4615 4615 $251 $251 PUMPS & MISC 0.20 0.10 52 40 $3 $2 SPACE COOL 27.00 35.60 7923 10427 $431 $567 SPACE HEAT 0.00 4.70 0 1385 $0 $75 VENT FANS 20.80 23.50 6109 6894 $332 $375 Credits Applied: None PASSES Passing Criteria =1223 Design (including any credits) =1114 Passing requires Proposed Building cost to be at most 85% of Baseline cost. This Proposed Building is at 77.4% EnergyGauge Summit0 FlalCom-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 1/26/2017 Page 4 of 13 External Lighting Compliance Description Category Tradable? Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (W) (Sgft or it) None Project: Elks Park Title: Elks Park Type: Sports Arena (WEAFile: DAYTONABEACH.TMY) Lighting Controls Compliance Acronym Ashrae Description Area Design Min Compti- ID (sq.ft) CP CP ance PrOZO1Sp1 13 All Sports - Seating Area 630 1 1 PASSES PrOZo2Sp1 7 FoodService- Kitchen 630 1 1 PASSES PASSES EnergyGauge Summ t@ FlalCom-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 1/26/2017 Page 5 of 13 Project: Elks Park Title: Elks Park Type: Sports Arena (WEAFile: DAYTONABEACH.TMY) System Report Compliance PrOSyl System 1 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 41000 16.00 13.00 8.00 PASSES Split System < 65000 Btu/h Cooling Capacity Air Handling System Air Handler (Supply) - 1600 0.80 0.82 PASSES -Supply Constant Volume PrOSy2 System 2 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 54000 16.00 13.00 8.00 PASSES Split System < 65000 Btu/h Cooling Capacity Air Handling System Air Handler (Supply) - 1400 0.80 0.82 PASSES -Supply Constant Volume PASSES Plant Compliance Description Installed Size Design Min Design Min Category Comp No Eff Eff IPLV B'LV liance None EnergyGauge SummilO Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 1/26/2017 Page 6 of 13 Water Heater Compliance DDesign Min Description 1�pe Category Eff Eff Design Max Comp Loss Loss Hance None Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-infl r Thick [in] Thick [in] 19 SF.F] None EnergyGauge SummiR Fla/Com-2014. TAM 20%1.0 Compliant Software. Effective Date: June 30, 2015 1/26/2017 Page 7 of 13 Mandatory Requirements (as applicable) Mandatory requirements compiled by US Department of Energy and Pacific Northwest National Laboratory. Adopted with permission Topic Section Component Description Yes ----"��— NIA Ex 1. To be checked by Designer or Engineer Fenestration C402.2.7 Envelope U-factor of opaque doors associated with the building thermal envelope meets requirements. Insulation C4022.1.1 Envelope High-albedo roofs satisfy one of the following: 3-year-aged solar reflectance >= 0.55 and thermal emit ance>= 0.76, 3-year-aged solar reflectance index >= 64.0, initial year solar reflectance >= 0.70 and thermal emittance >= 0.75, or initial year solar Wattage C405.6 Exterior Lighting Exterior grounds lighting over 100 W provides>60 ImrW unless on motion sensor or fixture is exempt from scope of code or from external LPD. Wattage C405.4 Interior Lighting Exit signs do not exceed 5 watts per face. ❑ ❑ Wattage C405.2.3 Interior Lighting Additional interior lighting power allowed for special El 0 functions per the approved lighting plans and is automatically controlled and separated from general lighting. HVAC C4032.6 Mechanical Exhaust air energy recovery on systems meeting El E/ ❑ Table C403.2.6 SYSTEM C403.3.1,C403.3.1.1 Mechanical Air economizers provided where required, meet the ❑ d —SPECIFIC requirements for design capacity, control signal, ventilation controls, high -limit shut-off, integrated economizer control, and provide a means to relieve SYSTEM C403.3.1,C403A.1 Mechanical excess outside air during operation. Water economizers provided where required, meet —SPECIFIC the requirements for design capacity, maximum pressure drop and integrated economizer control. SYSTEM —SPECIFIC C403A.1.4 Mechanical Economizer operation will not increase heating energy use during normal operation. SYSTEM C403.2.10.1 Mechanical HVAC fan systems at design conditions do not 0 0 ❑ —SPECIFIC exceed allowable fan system motor nameplate hp or fan system bhp. SYSTEM —SPECIFIC C4032.102 Mechanical HVAC fan motors not larger than allowable limits. 0❑ SYSTEM —SPECIFIC C404.2 Mechanical Service water heating equipment meets efficiency 0 El requirements. SYSTEM C4032.3 Mechanical Centrifugal fan open -circuit coormg towers having —SPECIFIC combined rated capacity >= 1100 gpm meets minimum efficiency requirement: >=38.2 gpm/hp. 2. To be checked by Plan Reviewer Air Leakage C402.4.7 Envelope Vestibules are installed on all building entrances. Doors have self -dosing devices. Insulation C402.2.6 Envelope Slab edge insulation depth/length. Slab insulation extending away from building is covered by pavement or >= 10 inches of soil. Plan Review C1032 Envelope Plans andfor specifications provide all information ❑ with which compliance can be determined for the building envelope and document where exceptions to the standard are claimed. Plan Review C1032 Exterior Lighting Plans, specifications, and/or calculations provide all ❑ ❑ information with which compliance can be determined for the exterior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include exterior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. EnergyGauge SummiM Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 1/26/2017 Page 8 of 13 Wattage C405.6.2 Exterior Lighting Exterior lighting power is consistent with what is ❑ ❑ shown on the approved fighting plans, demonstrating proposed watts are less than or equal to allowed watts. Plan Review C103.2 Interior Lighting Plans, specifications, and/or calculations provide all information with which compliance can be determined for the interior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. HVAC C403.2.5.1 Mechanical Demand control ventilation provided for spaces >500 t12 and >25 peoplell 000 112 occupant density and served by systems with air side economizer, auto modulating outside air damper control, or design airflow>3,000 cfm. HVAC C403.2.4.3 Mechanical Each zone equipped with setback controls using automatic time clock or programmable control system. Plan Review C103.2 Mechanical Plans, specifications, and/or calculations provide all ❑ ❑ ❑ information with which compliance can be determined for the mechanical systems and equipment and document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. Plan Review C103.2 Mechanical Plans, specifications, and/or calculations provide all information with which compliance can be determined for the service water heating systems and equipment and document where exceptions to the standard are claimed. Hot water system sized per manufacturers sizing guide. SYSTEM —SPECIFIC C403.4.5 Mechanical Zone controls can limit simultaneous heating and cooling and sequence heating and cooling to each zone. SYSTEM —SPECIFIC C403.4.3.1 Mechanical Three -pipe hydronic systems using a common return for hot and chilled water are not used. SYSTEM C403.4.32 Mechanical Two -pipe hydronic systems using a common —SPECIFIC distribution system have controls to allow a deadband>=15 OF, allow operation in one mode for at least 4 his before changeover, and have rest controls to limit heating and cooling supply temperature to <=30 OF. SYSTEM —SPECIFIC C403.4.3.3.1 Mechanical Hydronic heat pump systems connected to a ❑ ❑ common water loop meet heat rejection and heat addition requirements. SYSTEM —SPECIFIC C4082.22 Mechanical HVAC hydronic heating and cooling coils have 1100 means to balance and have pressure test connections. SYSTEM —SPECIFIC C403A.2 Mechanical VAV fan motors>=7.5 hp to be driven by variable ❑ speed drive, have a vane -axial fan with variable pitch blades, or have controls to limit fan motor demand. SYSTEM C403.42.1 Mechanical VAV fans have static pressure sensors positioned ❑ El ❑ —SPECIFIC so setpoint <=1/3 total design pressure. SYSTEM C403.4.22 Mechanical Reset static pressure setpoint for DDC controlled ❑ 0 ❑ —SPECIFIC VAV boxes reporting to central controller based on the zones requiring the most pressure. SYSTEM —SPECIFIC C403.4.5.4 Mechanical Multiple zone HVAC systems have supply air temperature reset controls. SYSTEM C403.4.3.4 Mechanical Hydronic systems greater than 300.000 Btu/h —SPECIFIC designed for variable fluid flow. SYSTEM C403.4.3.4 Mechanical Temperature reset by representative building loads —SPECIFIC in pumping systems for chiller and boiler systems >300,000 Btum. SYSTEM C403.4.4 Mechanical Fan systems with motors>=7.5 hp associated with ❑ 0 ❑ —SPECIFIC heat rejection equipment to have capability to operate at 213 of full -speed and auto speed controls to control the leaving fluid temperature or condensing temp/pressure of heat rejection device. EnergyGauge Summit@ Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 1/26/2017 Page 9 of 13 Plan Review Plan Review C406 Project C402.32.2 Envelope Plans, specifications, and/or calculations provide all information with which compliance can be determined for the additional energy efficiency package options. Skylights in office, storage, automotive service, manufacturing, non4efrigerated warehouse, retail store, and distribution/sorting area have a measured haze value > 90 percent unless designed to exclude direct sunlight — — To be checked by Inspector_ — — Air Leakage _3. C402.4.1,C402.42 Envelope sThe building envelope contains a continuous air 0 0 El barrier that is sealed in an approved manner and either constructed or tested in an approved manner. Air barrier penetrations are sealed in an approved manner. Air Leakage C402.4.3,C402.4.4 Envelope Factory -built fenestration and doors are labeled as ❑ meeting air leakage requirements. Air Leakage C402.4.1.1 Envelope All sources of air leakage in the building thermal envelope are sealed, caulked, gasketed, weather stripped or wrapped with moisture vapor -permeable wrapping material to minimize air leakage. Air Leakage C402.4.6 Envelope Weatherseals installed on all loading dock cargo doors. Air Leakage C402.4.8 Envelope Recessed luminaires in thermal envelope to limit 0 0❑ infiltration and be IC rated and labeled. Seal between interior finish and luminaire housing. Fenestration C303.1.3 Envelope Fenestration products rated in accordance with NFRC. Fenestration C303.1.3 Envelope Fenestration products are certified as to performance labels or certificates provided. Insulation C303.2 Envelope Below -grade wall insulation installed per ❑ manufacturer's instructions. Insulation C303.2 Envelope Slab edge insulation installed per manufacturer's ❑ ❑ ❑ instructions. Insulation C403.2.7,C4082.8,( Envelope Exterior insulation protected against damage, 13❑ ❑ sunlight, moisture, wind, landscaping and equipment maintenance activities. Insulation C402.4.2.1 Envelope Roof R-value. For some ceiling systems, verification may need to occur during Framing Inspection. Insulation C303.2 Envelope Roof insulation installed per manufacturer's Instructions. Blown or poured loose -fill insulation is installed only where the roof slope is <=3 in 12. Insulation C402.2.1 Envelope Skylight curbs are insulated to the level of roofs ❑ ❑ with insulation above deck or R-5. Insulation C3032 Envelope Above -grade wall insulation installed per manufacturer's instructions. Insulation C303.2 Envelope Floor insulation installed per manufacturer's 11❑ ❑ instructions. Insulation C303.1 Envelope Building envelope insulation is labeled with R-value ❑ ❑ or insulation certificate providing R-value and other relevant data. Insulation C3032.1 Envelope Exterior insulation is protected from damage with a ❑ ❑ protective material. Verification for exposed foundation insulation may need to occur during Foundation Inspection. Insulation C4022.1 Envelope Insulation intended to meet the roof insulation 0❑ 11 requirements cannot be installed on top of a suspended ceiling. Mark this requirement compliant if insulation is installed accordingly. Controls C405.2A Exterior Lighting Automatic lighting controls for exterior righting 0❑ ❑ installed. Controls C405.2.2.1 Interior Lighting Automatic controls to shut off all building lighting installed in all buildings. EnergyGauge Summit@ Fla1Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 1/26/2017 Page 10 of 13 Controls C405.2.1.1 Interior Lighting Independentlighting controls installed per proved righting plans and all manual controls readily accessible and visible to occupants. Controls C405.2.1.2 Interior Lighting Lighting controls installed to uniformly reduce the ❑ 13 lighting load by at least 50%. Controls C40522.3 Interior Lighting Daylight zones provided with individual controls that control the lights independent of general area lighting. Controls C405.2.3 Interior Lighting Sleeping units have at least one master switch at ❑ the main entry door that controls wired luminaires and switched receptacles. Controls C405.2.2.2 Interior lighting Occupancy sensors installed in required spaces. 0 00 Controls C405.2.2.3 Interior Lighting Primary sidefighted areas are equipped with ❑ ❑ ❑ required lighting controls. Controls C405.22.3 Interior Lighting Enclosed spaces with daylight area under skylights ❑ and rooftop monitors are equipped with required lighting controls. Controls C405.2.3 Interior Lighting Separate lighting control devices for specific uses 11❑ installed per approved lighting plans. Controls C405.3 Interior Lighting Fluorescent luminaires within odd numbered lamp 11❑ configurations that are with 10 feet center to center (f recess mounted) or are within 1 foot edge to edge (d pendant or surface mounted) shall be tandem wired. Wattage C405.5.2 Interior Lighting Interior installed lamp and fixture fighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. HVAC C4032.4.5 Mechanical Freeze protection and snowfice melting system ❑ ❑ ❑ sensors for future connection to controls. HVAC C403.2.3 Mechanical HVAC equipment efficiency verified. ❑ Air Leakage C402.4.5.1 Envelope Stair and elevator shaft vents have motorized ❑ dampers that automatically close. Air Leakage C402A.5.2 Envelope Outdoor air and exhaust systems have motorized El El ❑ dampers that automatically shut when not in use and meet maximum leakage rates. Check gravity allowed.dampers where HVAC C403.2.8.1 Mechanical Piping Insulation exposed to weather is protected from damage (due to sun, moisture, wind, etc.). HVAC C4032.7 Mechanical HVAC ducts and plenums insulated. Where ducts or plenums are installed in or under a slab, verification may need to occur during Foundation Inspection. HVAC C4032.8 Mechanical Thermally ineffective panel surfaces of sensible heating panels have insulation >= R3.5. HVAC C4032.7 Mechanical Ducts and plenums sealed based on static ❑ pressure and location. HVAC C408.2.2.1 Mechanical Air outlets and zone terminal devices have means for air balancing. HVAC C403.2.11 Mechanical Unenclosed spaces that are heated use only radiant heat. HVAC C403.2.4.1 Mechanical Heating and cooling to each zone is controlled by a thermostat control. HVAC C403.2.4.2 Mechanical Thennostatic controls have a 5 °F deadband. 0 ❑ HVAC C403.2A.2 Mechanical Temperature controls have setpoint overlap restrictions. HVAC C4032A.3 Mechanical Automatic Controls: Setback to 55°F (heat) and ❑ ❑ 85°F (cool); 7-day clock, 2-hour occupant override, 10-hour backup SYSTEM C404.3 Mechanical Temperature controls installed on service water ❑0 ❑ —SPECIFIC heating systems (110 °F for dwelling units and lavatories in public restrooms and 90 °F for other EnergyGauge Summit0 Ra1Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 1/26/2017 Page 11 of 13 SYSTEM —SPECIFIC C404.4 Mechanical Automatic time switches installed to automatically El 0 El switch off the recirculating hot-water system or heat trace. SYSTEM C404.2 Mechanical Heat traps installed on non -circulating storage 000 —SPECIFIC water tanks. SYSTEM C4032.3 Mechanical PTAC and PTHP with sleeves 16 in. by 42 in. 000 —SPECIFIC labeled for replacement only as per Footnote b to Table C403.2.3(3). SYSTEM C403.4.2 Mechanical VAV fan >= 7.5 hp are driven by mechanical or ❑ ❑ —SPECIFIC electrical variable speed drive, or driven by vane-a)ual with variable speed blades, or operate With motor demand <=30% design kW at 50% design flow - calculations required SYSTEM —SPECIFIC C403.2.8 Mechanical HVAC piping insulation thickness. Where piping is 11❑ ❑ installed in or under a slab, verification may need to occur during Foundation Inspection. SYSTEM —SPECIFIC C403.2.7.1.3 Mechanical Ductwork operating >3 in. water column requires 110❑ air leakage testing. SYSTEM —SPECIFIC C403.4.3.5 Mechanical Reduceto ultiple ❑ ❑ boilers when others are shuthdp SYSTEM —SPECIFIC C403.4.3.3.3 Mechanical Two -position automatic valve interlocked to shut off 11 water flow when hydronic heat pump with pumping system >10 hp is off. SYSTEM C403.4.6 Mechanical Condenser heat recovery system that can heat ❑ ❑ 0 —SPECIFIC water to 85 OF or provide 60% of peak heat rejection is installed for preheating of service hot water in 24/7 facility, water cooled systems reject >6 MMStu, SHW load>=1 MMBtu. SYSTEM C403.4.7 Mechanical Hot gas bypass limited to: ❑ 0 ❑ —SPECIFIC <=240 kBbA — 50% >240 kBturn —25'/n SYSTEM C403.2.42 Mechanical Heating and cooling to each zone is controlled by a 0❑ —SPECIFIC thermostat control. Minimum one humidity control device per installed humidification/dehumidification system. SYSTEM SPECIFIC C4032.4.3.3 Mechanical Systems include optimum start controls. ❑ 1-3 ❑ SYSTEM —SPECIFIC C403.2.4.1.1 Mechanical Heat pump controls prevent supplemental electric ❑ ❑ resistance heat from coming on when not needed. SYSTEM —SPECIFIC C404.3 Mechanical Public lavatory faucet water temperature <=110'F. SYSTEM SPECIFIC C404.5 Mechanical All piping in circulating system insulated 11❑ SYSTEM —SPECIFIC C404.5 Mechanical First 8 ft of outlet piping is insulated ❑ 11 ❑ SYSTEM —SPECIFIC C404.5 Mechanical A I heat traced or externally heated piping insulated SYSTEM C404.6 Mechanical Controls are installed that limit the operation of a —SPECIFIC recirculation pump installed to maintain temperature of a storage tank. SYSTEM —SPECIFIC C404.7.1 Mechanical Pool heaters are equipped with onloff switch and no continuously burning pilot light SYSTEM C404.7.3 Mechanical Vapor retardant pool covers are provided for 11 —SPECIFIC heated pools and permanently installed spas. SYSTEM —SPECIFIC C404.72 .Mechanical Time switches are installed on all pool heaters and pumps. Testing C408.2.32 Mechanical HVAC control systems have been tested to ensure proper operation, calibration and adjustment of controls. MandatoryAdditional 1 C406 Project Efficient HVAC performance, efficient lighting 13❑ system, or on -site supply of renewable energy consistent with what is shown the approved plans. Insulation 0402.2.8 Project Bottom surface of floor structures incorporating ❑ ❑ radiant heating insulated to >=R-3.5. EnergyGauge Summit@ FlalCom-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 1/26/2017 Page 12 of 13 Post Construction C408.3 Exterior Lighting Lighting systems have been tested to ensure proper calibration, adjustment, programming, and operation. Post Construction C408.2.5.1 Interior Lighting Fumished as -built drawings for electric power systems within 30 days of system acceptance. Post Construction C303.3,C408.2.5.2 Interior Lighting Fumished O&M instructions for systems and equipment to the building owner or designated representative. Post Construction C408.3 Interior Lighting Lighting systems have been tested to ensure 0 El El proper calibration, adjustment, programming, and operation. Post Construction C408.2.5.1 Mechanical Furnished HVAC as-buiR drawings submitted within El 1:1 El 90 days of system acceptance. Post Construction C303.3,C408.2.5.2 Mechanical Furnishedualsfor HVAC systems within y0 system acceptance. Post Construction C408.2.5.3 Mechanical An air and/or hydronic system balancing report is 0 0❑ provided for HVAC systems. Post Construction C408.2.1 Mechanical Commissioning plan developed by registered 13 13 El design professional or approved agency. Post Construction C408.2.4 Mechanical Preliminary commissioning report completed and 13 11 ❑ certified by registered design professional or approved agency. Post Construction C408.2.5.4 Mechanical Final commissioning report due to building owner ❑ ❑ within 90 days of receipt of certificate of occupancy. Post Construction C408.2.3.1 Mechanical HVAC equipment has been tested to ensure proper ❑ ❑ ❑ operation. Post Construction C408.2.3.3 Mechanical Economizers have been tested to ensure proper ❑ operation. EnergyGauge Summit@ Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 1/26/2017 Page 13 of 13 EnergyGauge Summit® v5.20 INPUT DATA REPORT Proiect Information Project Name: Elks Park Orientation: North Project Title: Elks Park Building Type: Sports Arena Address: 25th St Building Classification: Renovation to existing building 25th St No.of Stories: 2 State: Fl Zip: 34950 GrossArea: 1260 SF Owner: St Lucie County Zones No Acronym Description Type Area Multiplier Total Area [sfJ [sf7 1 Pr0ZOI Zone 1 CONDITIONED 630.0 1 630.0 ❑ 2 PrOZo2 Zone 2 CONDITIONED 630.0 1 630.0 ❑ 1/26/2017 EnergyGauge Summit® v5.20 1 Spaces No Acronym Description Type Depth Width Height Multi Total Area Total Volume IN IN [ft] plier [sf] [cf] In Zone: PrOZol 1 PrOZOISpl ZOOSpl All Sports -Seating Area 21.00 30.00 9.00 1 630.0 5670.0 El In Zone: PrOZo2 1 PrOZo2Sp1 Zo0Sp1 FoodService- Kitchen 21.00 30.00 8.00 1 630.0 5040.0 ❑ Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [W] Ctrl pts In Zone: PrOZol In Space: Pr0ZolSp1 1 Suspended Fluorescent General Lighting 9 34 306 Manual On/Off 1 ❑ In Zone: PrOZo2 In Space: Pr0Zo2Sp1 1 Suspended Fluorescent General Lighting 8 34 272 Manual On/Off 1 ❑ Walls No Description Type Width H (Effec) Multi Area Orientation Conductance Heat Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] Capacity [Ib/cn [h.sEFBtu] [Btu/sUj In Zone: PrOZol 1 PIOZOlWal 5/8" stucco 30.00 9.00 1 270.0 North 0.2067 5,731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 1/26/2017 EnergyGauge Summit® v5.20 2 PrOZolWa2 5/8" stucco 21.00 9.00 1 189.0 East 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 3 PCOZolWa3 5/8" stucco 30.00 9.00 1 270.0 South 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4°ISO BTWN24"oc/.5" Gyp 4 PrOZolWa4 5/8" stucco 21.00 9.00 1 189.0 West 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp In Zone: PrOZo2 1 PrMo2Wa1 5/8" stucco 30.00 8.00 1 240.0 North 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 2 PrOZo2Wa2 0.75 in. stucco, 30.00 8.00 1 240.0 South 0.1119 1.183 14.94 8.9 ❑ 2x4x16" oc, R1113att, 0.5 in. gyp 3 PrOZo2Wa3 5/8" stucco 21.00 8.00 1 168.0 East 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 4 Pr0Zo2Wa4 5/8" stucco 21.00 8.00 1 168.0 West 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp Windows No Description Orientation Shaded U SHGC Vis.Tra W H (Effec) Multi Total Area [Btu/hr sf F1 IN [ft] plier [sf] In Zone: Pr0ZoI Ia Wall: Pr0Zo1Wa1 1 Pr0ZolWalW11 . North No 1.2500 0.82 0.76 6.00 5.00 3 90.0 El In Zone: PrOZo2 In Wall: PrOZo2Wa4 1 Pr0Zo2Wa4Wi1 West No 1.2500 0.82 0.76 2.00 2.00 2 8.0 1/26/2017 EnergyGauge Summit® v5.20 Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value IN [ft] plier [sf] [Btu/hr. sE F1 [Ib/cf] [Btu/sE F] [b.sf.FBtu] In Zone: PrOZol In Wall: PrOZo1Wa4 1 PrOZo1Wa4Dr1 Aluminum door, No 3.00 6.80 1 20.4 0.1919 43.67 0.53 5.21 ❑ 1.25 in. polystyrene In Zone: PrOZo2 In Wall: PrOZo2Wa2 1 PrOZo2Wa2Dr1 Aluminum door, No 3.00 6.80 1 20.4 0.1919 43.67 0.53 5.21 ❑ 1.25 in. polystyrene In Wall: PrOZo2Wa3 1 PrOZo2Wa3Drl Aluminum door, No 3.00 6.80 1 20.4 0.1919 43.67 0.53 5.21 ❑ 1.25 in. polystyrene In Wall: PrOZo2Wa4 1 PrOZo2Wa4Dr1 Aluminum door, No 3.00 6.80 1 20.4 0.1919 43.67 0.53 5.21 ❑ 1.25 in. polystyrene Roofs No Description Type Width H (Ef ec) Multi Area Tilt Cond. Heat Cap Dens. R-Value [ft] [ft1 plier [sf] [deg] [Btu/hr. SE Fl [Btu/sf. F] [lb/cf] [h.sEF/Btu] In Zone: PrOZol 1 PrOZolRfl Md Bldg Roof/R-19 30.00 21.00 1 630.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt Skylights No Description Type U SHGC Vis.Trans W H (Eflec) Multiplier Area Total Area [Btu/hr sf F] [ft] [ft] [Sf] [Sf] 1/26/2017 EnergyGauge Summit® v5.20 In Zone: In Roof: Floors No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. A F] [Btu/sG F] [Ib/cf] [h.sf.FBtu] In Zone: PrOZol I PrOZOIFII I ft, soil, concrete 30.00 21.00 1 630.0 0.2681 34.00 113.33 3.73 ❑ floor, carpet and rubber pad In Zone: PrOZo2 1 Pr0Zo2Fll 1 ft. soil, concrete 30.00 21.00 1 630.0 0.2681 34.00 i 113.33 3.73 ❑ floor, carpet and rubber pad Systems PrOSyl System 1 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System 41000.00 16.00 8.00 ❑ 2 Air Handling System -Supply 1600.00 0.80 ❑ PrOSy2 System 2 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System 54000.00 16.00 8.00 ❑ 2 Air Handling System -Supply 1400.00 0.80 ❑ 1/26/2017 EnergyGauge Summit® v5.20 Plant Equipment Category Size Inst.No Ell. IPLV Water Heaters W-Heater Description CapacitlCap.Unit I/PRt. Efficiency Loss El Ext-Lighting Description Category No. of Watts per Area/Len/No. of units Luminaires Luminaire [sf/ft/No] Control Type Wattage [W] Piping No Type Operating Insulation Temperature Conductivity [F] [ Btu-in/h.sf.F] Nomonal pipe Diameter [in] Insulation Is Runout? Thickness [in] Fenestration Used Name Glass Type No. of Glass SHGC VLT Panes Conductance [Btu/h.sf.F] ASHULSgICIrAII User Defined 1 1.2500 0.8200 0.7600 ❑ Frm 1/26/2017 EnergyGauge Summit® v5.20 Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sEF/Btu] 1009 0.75 in. stucco, 2x4xl6" oc, R11Batt, 0.5 in. No No 0.11 1.18 14.94 8.9 ❑ gyp Layer Material Material Thickness Framing No. [ft] Factor 1 267 0.75" stucco 0.0625 0.000 ❑ 2 266 2x4@16" oc+Rll Batt 0.2917 0.000 ❑ 3 187 GYP OR PLAS BOARD,1/21N 0.0417 0.000 ❑ Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sLF] [Btu/sEF] [lb/cf] [h.sf.FBtu] 1011 5/8" stucco /8"CMU/3/4"ISO No No 0.21 5.73 34.65 4.8 ❑ BTWN24"oc/.5" Gyp Layer Material Material Thickness Framing No. [ft] Factor 1 268 0,625"stucco 0.0521 0.000 ❑ 2 42 8 in. Lightweight concrete block 0.6670 0.000 ❑ 3 269 .75" ISO BTWN24" oc 0.0625 0.000 ❑ 4 187 GYP OR PLAS BOARD,1/2IN 0.0417 0.000 ❑ Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sEF] [Btu/sf.F] [lb/cf] [h.sf.F/Btu] 1047 Mtl Bldg Roof/R-19 Batt No No 0.05 1.34 9.49 20.3 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 94 BUILT-UP ROOFING, 3/81N 0.0313 0.000 ❑ 2 23 6 in. Insulation 0,5000 0.000 ❑ 1/26/2017 EnergyGauge Summit® v5.20 8 Materials Used Only R-Value RValue Thickness Conductivity Density SpecificHeat Mat No Acronym Description Used [h.sCF/Btu] IN [Btu/h.tt.F] [lb/cSJ [Btu/lb.F] 264 at o 214 Mat1214 POLYSTYRENE, EXP., No 5.2100 0.1042 0.0200 1.80 0.2900 ❑ 1-1/4IN, 187 Mat1187 GYP OR PLAS No 0.4533 0.0417 0.0920 50.00 0.2000 ❑ BOARD,1/2IN 178 Mat1178 CARPET W/RUBBER PAD Yes 1.2300 ❑ 265 Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000 ❑ 48 Matl48 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 ❑ 267 Mat1267 0.75" stucco No 0.1563 0.0625 0.4000 16.00 0.2000 ❑ 266 Mat1266 2x4@16" oc+R11 Batt No 8.3343 0.2917 0.0350 9.70 0.2000 ❑ 268 Mat1268 0.625" stucco No 0.1302 0.0521 0.4000 16.00 0.2000 ❑ 42 Mat142 8 in. Lightweight concrete No 2.0212 0.6670 0.3300 38.00 0.2000 ❑ block 269 Mat1269 .75" ISO BTWN24" oc No 2.2321 0.0621 0.0210 4.19 0.3010 ❑ 23 Mat123 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ 94 Mat194 BUILT-UP ROOFING, 3/81N No 0.3366 0.0313 0.0930 70.00 0,3500 ❑ Constructs Used Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sEF[ [Btu/sEF[ [Ib/cQ [h.sEFBtu[ 1002 Aluminum door, 1.25 in. polystyrene No No 0.19 0.53 43.67 5.2 ❑ Layer Material Material Thickness Framing No. IN Factor 1 264 ALUMINUM, 1/16IN 0.0050 0.000 ❑ 2 214 POLYSTYRENE, EXP., 1-1/4IN, 0.1042 0.000 ❑ 3 264 ALUMINUM, 1/16IN 0.0050 0.000 ❑ 1/26/2017 EnergyGauge Summit® v5.20 No Name Simple Construct Massless Conductance Heat Capacity Construct [Btu/h.sf.F] [Btu/sf.F] Density RValue [lb/cf] [h.sCF/Btu] 1057 1 ft. soil, concrete floor, carpet and rubber pad No No 0.27 34.00 113.33 3.7 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 265 Soil, l ft 1.0000 0.000 ❑ 2 48 6 in. Heavyweight concrete 0.5000 0.000 ❑ 3 178 CARPET W/RUBBER PAD 0.000 ❑ 1/26/2017 EnergyGauge Summit® v5.20 9 g ® Ri ht-Suite® Universal 2017 Short Form Job: wri htsoft g Date: Jan 16, 20,7 Unit Two By: St Lucie County, SCANNED BY 3t Lucie,County Proj ect Information For. Elks Park St Lucie County 25th St, Fort Pierce, FI Htg Clg Htg CIg Outside, db (OF) 42 89 Inside db (OF) 70 75 Outside RH (%) - 62 Inside RH N - 50 Outside wb (OF) - 78 Inside wb (OF) - 63 Daily range (OF) - 15 Design TD (OF) 28 14 Moisture dill. (gUlb) - 61 Heating Equipment Cooling Equipment Make Make Goodman Mfg. Model Model GSX160421 F Type Elec strip Type Split AC Efficiency 100 EFF COP / EER / SEER 16.0 Heating Input 5.1 kW Sensible Cooling 28.7 MBtuh Heating Output 17.5 MBtuh Latent Cooling 12.3 MBtuh Humidifier 4.1 gpd Total Cooling 41.0 MBtuh LeavingAirTemp 120.0 OF Leaving Air Temp 55.0 OF Actual Heating Fan 319 cfm Actual Cooling Fan 1367 cfm Equipment Location Unit Two System Type PEAKCV Fan Motor Heat Type PACKAGE Fan 8, Motor Combined Efficiency 0 % Static Pressure Across Fan 0 in H2O NAME Area Heat Sensible Latent Htg Clg Time ft' Loss Gain Gain cfm cfm SCORING ROOM 1 357 14071 14683 8500 182 770 Jul 1800 LDT SCORING RM 2 273 10569 11175 6180 137 597 Jul 1800 LDT Unit Two 630 24640 25858 14680 319 1367 Jul 1800 LDT 2017-Jan- 6 06:40:e0 wrightsoft• RIgMSude® Universal 201717.0.17 RSU06570 Page 2 J:\TransfeAManual AElls Park St Lucie Courdymp Calc = CLTD Frent Door faces E r' . At - wrightsoft° Right -Suite® Universal 2017 Load Summary Unit Two St Lucie County For. Elks Palk St Lucie County 25th St, Fort Pierce, FI Job: Date: Jan 16, 2017 By: Zone::; U it Two 1. DESIGN CONDITIONS at Jul 1800 LOT Inside: 75 OF Outside: 89 OF RH: 62 % MoistDiff: 61.5 grilb 2. SOLAR RADIATION THROUGH GLASS 3. TRANSMISSION GAINS Sensible Walls: 8591 Glass: 1373 Doors: 25 Partitions: 0 Floors: 0 Ceilings: 2053 4. INTERNAL HEAT GAIN Sensible Occupants: 5796 Lights: 113 Motors: 0 Appliances: 0 5. INFILTRATION: Outside air cfm: 6. SUBTOTAL: Space load Sensible Envelope 20827 Less external 0 Redistribution 0 7. SUPPLYDUCT S. SUBTOTAL: Space load + supply duct Actual cfm: 1367 at supply TD: 9. VENTILATION: Make-up air cfm: 10. RETURNAHI LOAD: Lighting + plenum (net) 11. RETURN DUCT 12. TOTAL LOADS ON EQUIPMENT 13. DESIGN CONDITIONS Inside: 70 OF Outside: 42 OF 14. TRANSMISSION LOSSES Walls: 9632 Glass: 2848 Doors: 52 Partitions: 0 Floors: 0 Ceilings: 950 15. DNFILTRATION: Outside air cfm: 16. SUBTOTAL: Space load Envelope 14969 Less external 0 Less transfer D Redistribution 0 17. SUPPLYDUCT: 18. VENTILATION: _Make-up air cfm: 19. HUMIDIFICATION Piping 20. RETURN DUCT 21. TOTAL HEATING LOAD ON EQUIPMENT OF3.-.-i1IIfi6Zthl4H1 TD: 14 OF Mult: 1.0 Ins.wb 63 OF Sensible Latent 2728 12041 Latent 5909 4788 4788 - - 0 10 148 418 Latent 20827 5206 5206 - - 0 - 1041 21869 20 - - 227 3365 9474 0 625 - 25858 14680 Mult: 1.0 TD: 28 OF 13482 48 1488 14969 748 -- --227 6979 1494 449 24640 Wrl htSOft 2017Jan-2606A0:50 9 RghtSude® Universal 2017 17.0.17 RSUG6570 Page 2 J:1TransfeAManual JOF s Park St Lude CourdXrup Cale = CLTD Frond DDor laces E Job M Performed for. Elks Park St Lucie County 25th St Fort Pierce, FI SECOND FLOOR St Lucie County 5" Freshair intake 227 CFM outside fresh air at .5 Static Pressurer Scale: 1 : 88 Page 2 RightSuftO Universal 2017 17.0.17 RSU06670 2017Jan-2606A0:58 ... JlBks Park St Lucie Countyrup This combination qualifies for a Federal Energy Efficiency Tax Credit when placed in service between Feb 17, 2009 and Dec 31, 2016. AHRI Certified Reference Number: 8242080 Date: 1/26/2017 Product: Split System: Air -Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: GSX160421 F* Indoor Unit Model Number: ASPT49D14A* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN; JANITROL; AMANA DISTINCTIONS; EVERREST; ONE HOUR AIR CONDITIONING AND HEATING; ENERGI AIR; FRANKLIN Region: All (AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, ID, IL, IA, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WV, WI, WY, U.S. Territories) Region Note: Central air conditioners manufactured prior to January 1, 2015, are eligible to be installed in all regions until June 30, 2016. Beginning July 1, 2016, central air conditioners can only be installed in region(s) forwhich they meet the: regionalefficiency requirement. Series name: GSX16 . . Manufacturerrresponsibld forthe rating ofithislsystem;coinbination.is GOODMAN MANUFACTURING CO., LP. testing J 'a... _ . f..u. Cooling Capacity(Btuh): 41000t,"yq ti¢II jr w, ,t I'I �V EER Rating (Cooling):. -13.00 SEERRatin ' Coolin IEER Rating (Cooling): Ratings followed by an asterisk (') indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certiflcateand Its contents are proprietary product's of AHRI. This Certificate shall only be used for Individual, personal and confidential reference purposes. The contents of this Certificate may not, In whole or In'part, be reproduced; copied; disseminated; `�®-�'� entered Into a computer database; or otherwise utilized, in any form or manner or by any means, except forthe user's Individual, personal and confidential reference. AIRCONDITIONING, HEATING, CERTIFICATE VERIFICATION 8 REFRIGERATION INSTITUTE The Information for the model cited on this certificate can beverified at www.ahrldifectory.org, click on `Verify Certificate' link we make life better^ and enter the AHRI Certified Reference Number and the date on which the certificate was Issued, which is listed above, and the Certificate No., which Is listed at bottom right. 02014 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: tstzs1taasssssza�