HomeMy WebLinkAboutPRODUCT APPROVAL1/2512017 Florida Building Code Online
I ProfessionalPReguIation. M ' ; ; ►111« f
.,, prdapdUC'tpffnvaln USER:Pub
Product A opmval Menu > Pmdu o
FL #
Application Type
Code Version
Application Status
CONCEALED FASTENERS OR ATTACHMENTS
> Application List > Application Detail ARE THE
RpE`S�Pq}O�N�SIIB��ieIl('yOf THE
FL7804-R9 yyfl' lyty I tlfl OF RBl1tlf1N
Revision SGANNEV
2014 BY
Approved St. Lucie Counts
Comments THESE PLANS AI4D ALL PROPOSED WORK
Archived `a ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY -FIELD INSPECTORS THAT
Product Manufacturer Entegra Roof Tile, Ina;M
Address/Phone/Email 1289 NE 9th Avenue ,.MAY ®E NECCES�AKIN ORDERITO °]
Okeechobee, FL2 3Ext @/� IVIPLY Wrr" ALL APPLICABLE CODES.
(863) 467-0042 Ext Sz�Z_8.'p
tjohnson@rooftile.com
Authorized Signature
Terry Johnson
tjohnson@rooftile.com
Technical Representative
Jim Deyarmond ST. LUCIE COUNTY BUILDINC DIVISION
Address/Phone/Email
1269 NE 9th Avenue,,,," ED FOR C LIAiiCE
Okeechobee, FL 349°Ff�
(863) 467-0042 REVIEWED
JDeyarmond@rooftiD 4'
PLANS AND PERMIT MUST BE KEPT ON JOY,
Quality Assurance Representative
Terry Johnson OR NO INSPECTION WILL RE MADE.
Address/Phone/Email
819 South Federal Hwy Suite 300
Stuart, FL 34994
(800) 586-7663
tjohnson@rooftile.com
Category Roofing
Subcategory Roofing Tiles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 11/04/2017
Validated By John W. Knezevich, PE
Certificate of Independence
Referenced Standard and Year (of Standard)
Validation Checklist- Hardcopy Received
:�• • t . 1 • -t -I
Standard
Year
ASTM C1492
2003
FRSA/TRI April 2012
2012
SSTD 11
1997
TAS 100
1995
TAS 101
1995
TAS 102
1995
TAS 102(A)
1995
hdpslhvww.floridabuilding.org/pr/pr app d8.aspx?param=wGEVXQwtDquavOjOHi%2bAMgs179p/p2bkb9MWI0gi8oylmr8p/pad 1/2
1I2fi=7 Florida Building Code Online
TAS 112
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 04/19/2016
Date Validated 04/20/2016
Date Pending FBC Approval 04/24/2016
Date Approved 06/08/2016
Summary of Products
1995
FL #
Model, Number or Name
Description
7804.1
Entegra Concrete Roof Tiles (HVHZ
Concrete Roof Tile
jurisdictions)
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL7804 R9 II 2016 04 FINAL ER ENTEGRA FL7804-
R9 HVHZ.Ddf
Approved for use outside HVHZ: No
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to ER Section 5 for Limits of Use. Refer to ER
Evaluation Reports
Section 6 for Installation.
FL7804 R9 AE 2016 04 FINAL ER ENTEGRA FL7804-
R9 HVHZ.odf
Created by Independent Third Party: Yes
7804.2
Entegra Concrete Roof Tiles (non-
Concrete Roof Tile
HVHZ jurisdictions)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL7804 R9 IT 2016 04 FINAL R ENTEGRA FL7804-
R9 NON-HVHZ.Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to ER Section 5 for Umits of Use. Refer to ER
Evaluation Reports
Section 6 for Installation.
FL7804 R9 AE 2016 04 FINAL ER ENTEGRA FL7804-
R9 NON-HVHZ.odf
Created by Independent Third Party: Yes
e acv nc.!
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone- 850-487.1824
The State of Fiords is an AAfEEO employer. Copyright 2007,2013 State of Florida.:: Pdvacv Statement :: Accessibility Statement:: Refund Statemem
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to section
455.275(1), Florida statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email aridness if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a
personal address, please provide the Department with an email address which con be made available to the public To determine if you act a licensee under Chapter
455, F.S., please didchere .
Product Approval Accepts!
® O _t6<!
Credit Card
Safe
hdpsJNywtvfloridabuillTing.org/pr/pr app dlt.aspx7param=wGEVXQwtDquovOjOHI%2bAMgsl79%2bkbgMWMci8oylmr8p/gad 7J2
EXTERIOR RESEARCH & DESIGN, U.C.
Certi%Imte of Authorization#9503
TRINITY ERD 353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
EVALUATION REPORT
Entegra Roof Tile, LLC Evaluation Report E39310.11.11-1-R3
r.NTEG A 1289 NE 9 th Avenue FL7804-119
R O O F T I L E Okeechobee,FL34972 Date of Issuance:11/02/2011
Revision 3: 04/18/2016
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the Sth Edition (2014) Florida Building Code
(HVHZ) sections noted herein.
DESCRIPTION: Entegra Concrete Roof Tiles (HVHZ jurisdictions)
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 9.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The Pdtsunile seal appeadn . authorized by Robert Nieminen,
P.E. on M/18/2016. This does not some as an elettmnioal"Igned
doament Shined, sealed hardwpies have been transmitted to the
Product Approval Administrator and to the named dient
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it Intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial Interest in any company manufacturing or distributing products for
which the evaluation reports are being Issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
M � }
H 1� 9 1C
TRINITY ERD
4. PRODUCT DESCRIPTION:
4.1 BERMUDA FLAT, PLANTATION Fur and HORIZON FLAT are TAS 112, Type 3a (flat -profile) concrete roof tiles.
Bermuda Flat
t5>
Plantation Flat
` . 17-1/4"
13" ..�
y
Horizon Flat
EMerlor Research and Design, I.I.C. Evaluation Report E39310.11.11-1-R3
Certlflmte ofAvthar4atian k9s03 FL7804-R9
Revision 3: 04/18/2015
Page 3 of 9
TRINITY ERD
4.4 GALENA SPANISH "S" and REGAL are TAS 112, Type 2a (non -interlocking, high -profile) concrete roof tiles.
17"
S. LIMITATIONS:
Galena Spanish "S"
regal
10"
5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is for use in FBC HVHZ jurisdictions or other jurisdictions adopting FBC HVHZ
requirements.
5.3 Fire classification is not part of this evaluation; refer to FBC Section 1516 or current Approved Roofing
Materials Directory for fire rating of this product.
5.4 Reference is made to FBC Section 1512.4.2.4 regarding field testing of completed tile roof installations.
5.5 Applicant shall retain the services of an FBC listed, accredited laboratory to perform quarterly tests in
accordance with TAS 112, Appendix W. Such testing shall be submitted to Trinity I ERD for review.
5.6 Minimum underlayment shall comply with the RAS 118, RAS 119 or RAS 120, as applicable. Underlayment
products shall hold Florida Statewide Product Approval or Local Approval for use in tile roof assemblies in
HVHZ jurisdictions.
5.7 Minimum roof deck requirements shall be in accordance with applicable FBC HVHZ requirements.
5.8 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and F.A.C. Rule 61G20-3.
Exterior Research and Design, LLC Evaluation Report E39310.11.11-1-R3
CertliProte ofAuthodratim 89503 FL7804-119
Revision 3: 04/18/2016
Page 5 of 9
Tile
Bermuda Fiat,
Plantation Flat or
Horizon
l _ C 1
TRINITY ERD
' TABLE3A-1: ATTACHMENT RESISTANCE. EXPRESSED ASA MOMENT-MF (FT-LBF)
g. FLAT PHOFILE,TILEs, MECHANICALLY ATTACHED SYSTEMS
Fastener
Direct -Deck
(min. 15/32-
plywood)
Direct -Deck
(min. 19/32"
plywood)
Battens
Type
R
Size
Shank
Clip
Nail
One
10d
Smooth or Screw
N/A
7.3
9.8
4.9
Nail
Two (2)
lOd
Smooth or Screw
N/A
14.0
18.8
7.4
Nail
One
10d
Smooth or Screw
Eave
19.0
19.0
22.1
Nail
One
SOd
Smooth or Screw
Field
24.3
24.3
24.2
Nail
Two (2)
SOd
Smooth or Screw
Eave
31.9
31.9
32.2
Nail
Two (2)
10d
Smooth or Screw
Field
35.5
35.5
34.8
Nail
Two (2)
-Two
10d
Ring
N/A
30.9
38.1
17.2
Nail'
(2)
10d'
Ring'
N/A
50.3'
65.5'
48.3'
Screw
One (1)
#8
N/A
N/A
30.8
30.8
18.2
Screw
Two (2)
#8
N/A
N/A
51.7
1 51.7
24.4
' Installation with a 4-inch tile headlap and fasteners located min. 2D4-inch from head of tile,
TABLE 3A-2: ATTACHMENT RESISTANCE EX PRESSED ASA MOMENT- MF(FT-LBF)
' '- `•� FLAT PROFILE TILES, ADHESNESET SYSTEMS ,
Tile
Application
Adhesive
Size
(inch)
Weight(g)
Mf(ft-Ibf)
Tile
To
Substrate
To Tile
Bermuda Flat,
Plantation Flat or
Inter -
Dependent
TILE BOND"'
x6
-11
-11
40.6
Touch'n Seal"' StormBond
5 x 8
-8.3
„10.2
73.2
ICP Adhesives Polyset RTA-1;
cross -bond
=long-4.5"
.5"„9^'S
ss headHorizonICP
51.8
Adhesives Polyset AH-160
x4
„16
„8
42.8
Independent
ICP Adhesives Polyset AH-160
/A
„30
N/A
50.9
2 x 10
N/A
-45
N/A
91.9
TABLE3B-1: ATTACHMENTRESISTANCE !`RESSEDAS A MOMENT- MF(FT-LBF)
Low PROFILE.TILES, MECHANICALLY.ATTACHED SYSTEMS7..:.=`.::
Tile
Fastener
Direct -Deck
- (min. 15/32"
plywood)
Direct -Deck
(min. 19/32"
plywood)
Battens
Type
#
Size
Shank
Clip
Nail
One(1)'
SOd
Smooth or Screw
N/A
8.82
31.8'
4.1'
Nail
Two (2)
10d
Smooth or Screw
N/A
16.4
21.9
7.1
Nail
One(1)'
10d
Smooth or Screw
Eave
19.02
19.02
22.12
Nail
One(1)2
10d
Smooth or Screw
Field
24.3'
24.3'
24.2'
Nail
Two (2)
10d
Smooth or Screw
Eave
31.9
31.9
32.2
Estate "5" or Hacienda
Nail
Two (2)
10d
Smooth or Screw
Field
35.5
35.5
34.8
Nail
I Two (2)
1 Sod
Ring
N/A
27.8
37.4
28.8
Nail'
7w0(2)'
lod'
Ring'
N/A
43.0'
67.5'
50.9'
Screw
One(1)2
#8
N/A
N/A
25.8'
25.8'
22.92
Screw
Two (2)
1 #g
LNJA
N/A
47.1
47.1
49.1
' Installation with a 4-inch tile headlap and fasteners located min. 2%-Inch from head of tile.
' For one (1) fastener Installations, utilize hole that is approximately 4'f.-inch from the interlocking edge.
Exterior Research and Design, LLC Evaluation Report E39310.11.11.1-R3
Certlgcete of Authorization 0503 FL7804-R9
Revision 3:04/18/2016
Page 7 of 9
Copy
TRINITY ERD
7. LABELING:
7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo, as detailed
below. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance
Agency noted herein.
and/or
ENTEERR
Labeling: Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "So
Hanson
Labeling: Horizon Flat, Hacienda, Regal
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Plant
Profiles
Okeechobee, FL
Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S"
Ft. Myers, FL
Horizon Flat, Hacienda
Deerfield Beach, FL
Horizon Flat, Hacienda, Regal
10. QUALITY ASSURANCE ENTITY:
PRI Construction Materials Technologies, I.I.C. — QUA9110; (813) 621-5777
- END OF EVALUATION REPORT —
Exterior Research and Design, U.C. Evaluation Report E39310.11.11-1-R3
Cerdflznte of Authorization 09503
FL7904-R9
Revislon 3:04/18/2016
Page 9 of 9
1/2512017 Florida Building Code Online
D n.INaC�DrpAprM6M OF '
,pBusmess &,Professional Regulation T
" 0• • N
bOFF.�tEO �,•••�•Ir•
BECREfAR1'
c Product Approval
6 USER: Public User
n u{
Stats a Facts . PubllmUom I FBC Stan ' BCIS Site Map ' Links search
P d_ A ' My > Ppdv� or ADD' lutiOn SEa Mh > Aooliation L > Appriwtion Detail
FL *
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
FL5259-R25
Revision
2014
Approved
POLYGLASS USA
150 Lyon Drive
Fernley, NV89408
(570) 384-1230 Ext 242
Jakins@Polyglass.com
James Akins
lakins@polyglass.com
Steve Wadding
150 Lyon Drive
Fernley, NV 98408
(602) 363-7139
stevew@poi ygla ss. co m
James Akins
555 Oakridge Road
Humboldt Industrial Pkwy
Hazleton, PA 18201
(800) 894-4563
Jakfns@polyglass.com
Roofing
Underlayments
Old P Y
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Robert Nleminen
PE-59166
UL LLC
04/24/2018
John W. Knezevich, PE
s Validation Checklist - Hardcopy Received
i a t. I a r "u t"M.
Standard
Year
ASTM D1970
2009
ASTM D226
2006'
ASTM D6164
2005
ASTM D6222
2008
ASTM G154
2006
ASTM G155
2005
https:/Aaww.floridabuilding.orgfpr/pr app d8.aspx7param=wGEVXOwtDgvbSgAaZp3Crk2vS%2feg01ipmOTAu7g3GAlUPJLg63BcVw%3d%3d 112
1/25/2017
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Florida Building Code Online
FM 4474
FRSA/TRI April 2012
TAB 103
UL 1897
Method 1 Option D
10/17/2016
10/18/2016
10/19/2016
12/15/2016
=a C(lp kj ,
2004
2012
1995
2004
FL #
Model, Number or Name
Description
5259.1
Polyglass Roof
Roofing underlayments
Underlayments
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FI 5259 R25 11 2016 10 FINAL ER POLYGLASS UNDERLAYMENTS FL5259-
R25.pd_f
Approvedfor use outside HVHZ:Yes
Impact Resistant: N/A
Verified By: Robert Nleminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure In this
application relates to one particular
Evaluation Reports
FlS259 R25 AE 2016 SO FINAL ER POLYGLASS UNDERLAYMENTS FL5259-
R25, odf
underlayment system (over concrete deck) for
use under foam -on tile systems (where the
Created by Independent Third Party: Yes
underlayment forms part of the load -path).
Refer to ER Section 5.6.4 for other systems,
other deck types and associated maximum
design pressures. 2.) Refer to ER Section 5 for
other limits of use.
BacA Ye nt
contact Us :: 2601 Blair Stone Read 1211ahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EW employer. Copyright 2007-2013 State of Florida.:: Rivacv Statement :: Accessibllity Statement :: Refund Statemem
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response W a publlarecords request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. Wursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish m supply a
personal address, please provide the Department with an email address which can be made available to the public To determine If you are a licensee under chapter
455, F.S., please dick here.
Product Approval Accepts:
am ® `[C1M M
Credit Card
Safe
httpslAvwtv.floridabuilding.org/pr/pr app O.aspx?param=wGEVXQwtDgvbSgAaZp3Crk2vS%2feg01ipmOTAu7g3GAIUPJLg63Bc\&v%3d%3d 2/2
I TRINITY ERD
EVALUATION REPORT
Polyglass USA, Inc.
150 Lyon Drive
Fernley, NV 98408
1,71E, 01, �
EXTERIOR RESEARCH & DESIGN, U.C.
Certificate of Authorization N9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
Evaluation Report P12060.02.09-1121
FL5259-R25
Date of Issuance:02/24/2009
Revision 21:10/17/2016
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted
herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 13.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert Nieminen,
P.E. on 10/17/2016. This does not serve as an electronically
signed document. Signed, sealed hardcoples have been
transmitted to the Product Approval Administrator and to the
named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY ERD
Kafty
Examination
Reference
Date
ERD (TST 6049)
Physical Properties
P33370.03.11
03/02/2011
ERD (TST 6049)
Physical Properties
P33370.04.11
04/26/2011
ERD (TST 6049)
Physical Properties
P37300.10.11
10/19/2011
ERD (TST 6049)
Physical Properties
P40390.08.12-1
08/06/2012
ERD (TST 6049)
Physical Properties
P40390.08.12-2
08/07/2012
ERD (TST 6049)
Physical Properties
C41420.09.12-3
09/11/2012
ERD (TST 6049)
Wind Uplift
P39680.03.13
03/04/2013
ERD (TST 6049)
Physical Properties
P45370.04.13
04/26/2013
ERD (TST 6049)
Wind Uplift
P1738.02.07-R2
04/29/2013
ERD (TST 6049)
Wind Uplift
11757.04.01-1-R1
04/30/2013
ERD(TSi 6049)
Wind Uplift
P41630.08.13
08/06/2013
ERD (TST 6049)
Wind Uplift
P11751.05.03-RS
11/26/2013
ERD (TST 6049)
Wind Uplift
P11781.11.03-R1
11/26/2013
ERD (TST 6049)
Physical Properties
P45270.05.14
05/12/2014
ERD (TST 6049)
Physical Properties
6020.07.14-1
09/08/2014
ERD (TST 6049)
Physical Properties
6020.09.14-2
09/08/2014
ERD (TST 6049)
Physical Properties
6020.09.14-3
09/08/2014
ERD (TST 6049)
Physical Properties
6020.09.14-4
09/08/2014
ERD (TST 6049)
Physical Properties
6020.09.14-5
09/08/2014
ERD (TST 6049)
Physical Properties
6020.09.14-6
09/08/2014
ERD (TST 6049)
Physical Properties
P46520.10.14
10/03/2014
ERD (TST 6049)
Physical Properties
P44360.10.14
10/07/2014
ERD (TST 6049)
Physical Properties
P43290.10.14
10/17/2014
ERD (TST 6049)
Physical Properties
PLYG-SC7550.03.15
03/24/2015
ERD (TST 6049)
Physical Properties
P40390.04.15
04/03/2015
ERD (TST 6049)
Physical Properties
PLYG-SC8080.05.15-1
05/20/2015
ERD (TST 6049)
Wind Uplift
PLYG-SC8905.05.16-1
05/17/2016
ERD (TST 6049)
Physical Properties
PLYG-SC8080.07.16
07/16/2016
ERD (TST 6049)
Wind Uplift
PLYG-SC12025.10.16
10/12/2016
ICC-ES(EVL 2396)
IBCCompliance
ESR-1697
11/01/2014
Miami-Dade(CER 1592)
HVHZCompliance
NOA14-0717.08
01/22/2015
Polyglass USA
Manufacturing Affidavit
Products Current
02/1812009
Polyglass USA
P/LAffidavit
Mule -Hide Cross Ltg
03/01/2008
Polyglass USA
Materials Affidavit
Polystick SA Compound
08/18/2011
UL, I.I.C. (QUA9625)
Quality Control
Service Confirmation
Exp.04/24/2018
4. PRODUCT DESCRIPTION:
4.1 Mechanically Fastened Underlayments:
4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet.
4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet.
4.1.3 Polyglass G2 Base is a fiberglass -reinforced, asphaltic base sheet.
4.1.4 Polyglass APP Base is a fiberglass -reinforced, APP modified bitumen base sheet.
4.2 Self -Adhering Underlavments:
4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced
with polyolefinic film surface; meets ASTM D1970 and TAS 103.
4.2.2 Polystick MTS PLUS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced,
surfaced with poly -film surface; meets TAS 103.
4.2.3 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an
aggregate surface; meets ASTM D1970.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R21
Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION FL5259-RZS
Revision 21: 10/17/2016
Page 3 of 13
�
"FILE l VON
TRINITY ERD
Thsml: ROOF COVER OFnous •I
Underlayment
Asphalt Shingles
Nall -On The
Foam -On Tile
Metal
wood Shakes&'
Shingles
State
Polystick TU Max
No
Yes
Se Yes
5.Polystick
Yes
No
No
Dual Pro
Yes
Yes
No
Yes
Yes
Yes
Polystick Tile Pro
Yes
Yes
se Yes
5.Polystick
Yes
Yes
Yes
MU-X
Yes
No
No
Yes
Yes
Yes
Elastoflex S6G
Yes
Yes
seYes.1
No
Yes
Yes
Elastoflex S6 G FR
Yes
Yes
No
No
Yes
Yes
PolylleaG
Yes
Yes
SeeYes
5.Polyflex
No
Yes
Yes
G FR
Yes
Yes
No
No
Yes
Yes
Polyflex SAP or SAP FR
Yes
Yes
se Ye 5.1
No
Yes
Yes
Mule -Hide SA-APP Cap Sheet
Yes
Yes
Yes
No
Yes
Yes
or SA-APP Cap Sheet (FRI
see s.5.1
5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives unless tensile adhesion / long term aging
data from an accredited testing laboratory is provided.
✓ 3M'" 2-Component Roof Tile Adhesive AH-160 (FL6332): Polystick TU P, Polystick TU Plus, Polystick TU Max,
Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP
Cap Sheet (FR) or Tile Pro.
✓ 31Mm Foam Roof Tile Adhesive RTA-1 (FL6276): Polystick TU P, Polystick TU Plus, Polystick TU Max, Elastoflex S6
G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
or Tile Pro
✓ Convenience Products' Touch'n Seal Storm Bond Roof Tile Adhesive (FL14506): Polystick TU Plus, Polystick TU
Max.
✓ DowTileBond (FL717): Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro.
✓ Polyglass PolyLok Roof Tile Adhesive (FL17855): Polystick TU Plus or Polystick TU Max.
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Polystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet
(FR) self -adhered to:
➢ New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing
plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels
(designed and installed to meet wind loads for project).
Note: Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or
OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes.
Elastoflex S6 G or S6 G FR in hat asphalt to:
➢ ASTM D41 primed structural concrete.
Polyflex G or G FR torch -applied to:
➢ ASTM D41 primed structural concrete.
Exterior Research and Design, U.C. Evaluation Report P12060.02.09-R21
Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION FL5259-R25
Revision 21: 10/17/2016
Page 5 of 13
r TRINITY ERD
5.6.4.3 Maximum Design Pressure =-105 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-3000
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyfl x SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
1%" ring shank nails through 32 ga., 1-5/9" diameter tin caps spaced 12-inch o.c.
5.6.4.4 Maximum Design Pressure =435 osf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) PG100 or ASTM D41
Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints.
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
5.6.4.5 Maximum Design Pressure=-315 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Tile Pro, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap
Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
5.6.4.6 Maximum Design Pressure = -622 5 osf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
5.6.4.7 Maximum Design Pressure = -30 0 osf*:
Deck: Min. 15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
5.6.4.8 Maximum Design Pressure =-37.5 osf*:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
5.6.4.9 Maximum Design Pressure=-37.5 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) or two (2) layers ASTM D226, Type 11 felt
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
Exterior Research and Design, U.C.
Certificate of Authorization #9503
FBC NON-HVHZ EVALUATION
Evaluation Report P12060.02.09-R21
FL5259-RZ5
Revision 21: 10/17/2016
Page 7 of 13
w�lv a COT
li TRINITY ERD
5.6.4.17 _Maximum Design Pressure =-60 osf:
Deck Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
5.6.4.18 _Maximum Design Pressure = -67 5 osf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment)
Fasteners: 12 ga. x 1.25-Inch long x 3/8-Inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c, at the 4-inch wide side laps and 8-inch o.c, at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
5.6.4.19 Maximum Design Pressure =-75 osf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG 914 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip 914 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 10-inch o.c. at the 4-inch wide side laps and 10-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex56 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
5.6.4.20 Maximum Design Pressure =-90 osf:
Deck: Min. 15/32-inch plywoodto meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
5.6.4,21 Maximum Design Pressure =-90asf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6-inch o.c. at the 4-Inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex SG G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
5.6.4.22 Maximum Design Pressure=-90 osf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-inch o.c. at the 4-Inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt.
5.6.4.23 Maximum Design Pressure = -90 osf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
Exterior Research and Design, U.C.
Certificate of Authorization #9503
FBC NON-HVHZ EVALUATION
Evaluation Report P12060.02.09-R21
FL5259-R25
Revision 21: 10/17/2016
Page 9 of 13
J TRINITY ERD
Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30
days.
Elastoflex S6 G or S6 G FR or Polyflex G or G FR does not have an exposure limitation, unless the prepared roof
covering is to be adhesive -set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum exposure is 180
days.
6. INSTALLATION:
6.1
6.2
6.3
6.3.1
6.3.2
6.3.3
6.4
6.4.1
6.4.2
Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate (if applicable).
Elastobase. Elastobase P or Mule -Hide Nail Base:
Shall be Installed in compliance with the codified requirements for ASTM D226, Type If underlayment in FBC Sections
1507 for the type of prepared roof covering to be installed.
Non -Tile Applications:
Reference is made to the current edition of the NRCA Steep -slope Roofing Manual and ARMA recommendations for
installing shingle underlayments and flashings
Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP or SAP FR,
Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or Tile Pro, self -adhered, Elastoflex S6 G or S6 G FR in
hot asphalt or Polyflex G or G FR, torch applied.
Tile Applications:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted
above as a guideline.
Polystick MTS, MIS PLUS. IR-Xe, TU P TU Plus TU Max Dual Pro Tile Pro or MU X or Polyflex SAP POlvflex SAP FR
Mule -Hide SA-APP CaD Sheet or Mule -Hide SA APP Cap Sheet (FR):
Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Sections 1507
for the type of prepared roof covering to be installed.
Direct -to -Deck with Mechanically Fastened Roof Covers:
All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP Cap
Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam in accordance with Polyglass / Mule -Hide
Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch diameter
metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back -nailed using
the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane. The
head lap membrane is to cover the area being back -nailed
All seal -lap seams (selvage laps) must be
firmly rolled with a minimum 28 lb. hand
roller to ensure full contactand adhesion. •"s`sfi'c"^?:i
For Dual Pro and Tile Pro, align the edge of
the top sheet to the end of the glue pattern
(the sheet will overlap the fabric).
Exterior Research and Design, U.C.
Certificate of Authorization #9503
View of Ovelap Seam of Dual Pro and Tile Pro
FBC NON-HVHZ EVALUATION
Evaluation Report P12060.02.09-R21
FL5259-R25
Revision 21:10/17/2016
Page 11 of 13
7.
8.
9.
zz COPY
TRINITY ERD
6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04.12) must be used
on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or sail-
boards, to prevent tile sliding and/or damage to the underlayment during the loading process.
6.7.3 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile.
6.7.4 For nail -on tile systems over Polystick MTS PLUS:
➢ Battens are required for loading/staging of lugged tile regardless of slope.
➢ Battens are required for loading/staging of flat tile at slopes in excess of 5:12.
6.7.5 The minimum cure time after installation of self -adhering membranes and before loading of roofing tiles is forty-eight
(48) hours.
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
MANUFACTURING PLANTS:
Contact the noted CA agency for information on product locations covered for F.A.C. Rule 61G20-3 QA requirements.
QUALITY ASSURANCE ENTITY:
UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com
Exterior Research and Design, LLC.
Certifimte of Authorization X9503
END OF EVALUATION REPORT -
FBC NON-HVHZ EVALUATION
Evaluation Report P12060.02.09-R21
FL5259-RZS
Revision 21: 10/17/2016
Page 13 of 13