HomeMy WebLinkAboutMISC EMAIL1It2Ct0
St. Lucie County, Building Department
2300 Virginia Ave.
Ft. Pierce, Florida
RE: 1200 W. Midway Rd.
Ft. Pierce„ Florida
Per #_ 6. L1-017,500
axe•>�:�,�:�,�
To Whom it may concern:
OUAINIVtLI
BY
�T 1 ucie County
JUM 16 2017
PERPdITTiNG
St. Lucie County, FL
Please be advised that Architectonic Inc. has reviewed the ADA accessible roll out
counter and verify that it meets with the requirements of the 2014 Florida Accessibility
Code for the above referenced project.
C r�
806 Delaware Ave Tel: 772 460 7751 www.architectonicinc.com
Ft. Pierce, Florida 34950 Fax: 772 460 4244 FL Reg, # AA26003348
PAUL WELCH INC.
Mechanical * Electrical * Civil Engineering
1984 S.W. Biltmore St. Suite#114
Port Saint Lucie, FL 34984
Phone (772) 785 - 9888
Email pwelchinc@aol.com
February 8, 2017
Re: Door Replacement
3001 Industrial 3 Ave.
Fort Pierce, FL 34946
To Whom It May Concern:
JI;HIVNLL
St. Luce Count
Our office has calculated the required design pressure in accordance with ASCE 7-10 and
FBC 2014 for the replacement of the doors at the above referenced address.
Wind speed: V dt: 160mph, V.d: 124 mph
Exposure: C
Enclosure Type: Enclosed
Door Size: 18'-2" wide X 14'-0" high Overhead Door
Quantity of Doors: 3
Location: Per Attached Sketch
Required Design Pressure (Zone 5): +22.75/ -28.28 PSF Worst Case
Door to be installed shall be equal to, or exceed the required design pressures as listed
above. All installations shall be in accordance with FBC 2014 and manufacturer's
installation instructions.
Proposed Door: Clopay
FL#5678.21 (+/- 30 PSF).
Thank you for your attention to this matter.
Submitted by:
PAUL WELCH INC.
Paul Welch, P.E.
Reg. No 29945
Attached: Product Approval Affid.
Area of Work Plan
PAUL WELCH INC.
Mechanical * Electrical * Civil Engineering
1984 S.W. Biltmore St. Suite#114
Port Saint Lucie, FL 34984
Phone (772) 785 - 9888
Email pwelchinc@aol.com
Door Replacement
3001 Industrial 3 Ave.
Fort Pierce, FL 34946
AA
`9
A
A,
jUANNLU
BY
St. Lucie Count%
A 18'-2" W X 14'-0" H Overhead Door (REPLACE E)USTING)
AREA OF WORK PLAN nts... NORTH
Paul Welch, P.E.
Reg. No 29945
February 8, 2017
PAUL WELCH INC.
Mechanical * Electrical * Civil Engineering
1984 S.W. Biltmore St. Suite#114
Port Saint Lucie, FL 34984
Phone (772) 785 - 9888
Email pwelchinc@aol.com
February 8, 2017 THESE PLANS AND ALL PROPOSED WORK
Re: Door Replacement 6GANNED ARE SUBJECT TO ANY CORRECTIONS
3001 Industrial 3 Ave. BY REQUIRED BY FIELD INSPECTORS THAT
Fort Pierce, FL 34946 St. Lucie Crnmti MAY BE NECE5SARY.IN 0RDERTO ;,
CPMPLVWITH ALL APPLICABLE CQQE9
To Whom It May Concern:
Our office has calculated the required design pressure in accordance with ASCE 7-10 and
FBC 2014 for the replacement of the doors at the above referenced address.
Wind speed: Vic: 160mph, V.d: 124 mph
Exposure: C
Enclosure Type: Enclosed
Door Size: 18'-2" wide X 14'-0" high Overhead Door
Quantity of Doors: 3
Location: Per Attached Sketch
Required Design Pressure (Zone 5): +22.75/ -28.28 PSF Worst Case
Door to be installed shall be equal to, or exceed the required design pressures as listed
above. All installations shall be in accordance with FBC 2014 and manufacturer's
installation instructions.
Proposed Door: Clopay
FL#5678.21 (+/- 30 PSF).
Thank you for your attention to this matter.
Submitted by:
PAUL WELCH INC.
Paul Welch, P.E.
Reg. No 29945
Attached: Product Approval Affid.
Area of WorkPldn
* lut -0nj
ST. LU � COUNTY BUILDTING DIVISION
REVIEWED FOR CO IAIiCE
REVIEWED B
DATE
PLANS AND PERNUT MUST BE KEPT ON JOB
OR NO INSPECTION WILL BE r*UDE.
PAUL WELCH INC.
Mechanical * Electrical * Civil Engineering
1984 S.W. Biltmore St. Suite#114
Port Saint Lucie, FL 34984
Phone (172) 785 - 9888
Email pwelchinc@aol.com
Door Replacement
3001 Industrial 3 Ave.
Fort Pierce, FL 34946
AA
W
J
A
ouANNED
BY
3 1 iriP i;OWItV
A 18'-2" W X 14'-0" H Overhead Door (REPLACE EXISTING)
AREA OF WORK PLAN nts... NORTH
Paul Welch, P.E.,
Reg. No 29945
February 8, 2017