HomeMy WebLinkAboutMISC EMAIL1It2Ct0 St. Lucie County, Building Department 2300 Virginia Ave. Ft. Pierce, Florida RE: 1200 W. Midway Rd. Ft. Pierce„ Florida Per #_ 6. L1-017,500 axe•>�:�,�:�,� To Whom it may concern: OUAINIVtLI BY �T 1 ucie County JUM 16 2017 PERPdITTiNG St. Lucie County, FL Please be advised that Architectonic Inc. has reviewed the ADA accessible roll out counter and verify that it meets with the requirements of the 2014 Florida Accessibility Code for the above referenced project. C r� 806 Delaware Ave Tel: 772 460 7751 www.architectonicinc.com Ft. Pierce, Florida 34950 Fax: 772 460 4244 FL Reg, # AA26003348 PAUL WELCH INC. Mechanical * Electrical * Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone (772) 785 - 9888 Email pwelchinc@aol.com February 8, 2017 Re: Door Replacement 3001 Industrial 3 Ave. Fort Pierce, FL 34946 To Whom It May Concern: JI;HIVNLL St. Luce Count Our office has calculated the required design pressure in accordance with ASCE 7-10 and FBC 2014 for the replacement of the doors at the above referenced address. Wind speed: V dt: 160mph, V.d: 124 mph Exposure: C Enclosure Type: Enclosed Door Size: 18'-2" wide X 14'-0" high Overhead Door Quantity of Doors: 3 Location: Per Attached Sketch Required Design Pressure (Zone 5): +22.75/ -28.28 PSF Worst Case Door to be installed shall be equal to, or exceed the required design pressures as listed above. All installations shall be in accordance with FBC 2014 and manufacturer's installation instructions. Proposed Door: Clopay FL#5678.21 (+/- 30 PSF). Thank you for your attention to this matter. Submitted by: PAUL WELCH INC. Paul Welch, P.E. Reg. No 29945 Attached: Product Approval Affid. Area of Work Plan PAUL WELCH INC. Mechanical * Electrical * Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone (772) 785 - 9888 Email pwelchinc@aol.com Door Replacement 3001 Industrial 3 Ave. Fort Pierce, FL 34946 AA `9 A A, jUANNLU BY St. Lucie Count% A 18'-2" W X 14'-0" H Overhead Door (REPLACE E)USTING) AREA OF WORK PLAN nts... NORTH Paul Welch, P.E. Reg. No 29945 February 8, 2017 PAUL WELCH INC. Mechanical * Electrical * Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone (772) 785 - 9888 Email pwelchinc@aol.com February 8, 2017 THESE PLANS AND ALL PROPOSED WORK Re: Door Replacement 6GANNED ARE SUBJECT TO ANY CORRECTIONS 3001 Industrial 3 Ave. BY REQUIRED BY FIELD INSPECTORS THAT Fort Pierce, FL 34946 St. Lucie Crnmti MAY BE NECE5SARY.IN 0RDERTO ;, CPMPLVWITH ALL APPLICABLE CQQE9 To Whom It May Concern: Our office has calculated the required design pressure in accordance with ASCE 7-10 and FBC 2014 for the replacement of the doors at the above referenced address. Wind speed: Vic: 160mph, V.d: 124 mph Exposure: C Enclosure Type: Enclosed Door Size: 18'-2" wide X 14'-0" high Overhead Door Quantity of Doors: 3 Location: Per Attached Sketch Required Design Pressure (Zone 5): +22.75/ -28.28 PSF Worst Case Door to be installed shall be equal to, or exceed the required design pressures as listed above. All installations shall be in accordance with FBC 2014 and manufacturer's installation instructions. Proposed Door: Clopay FL#5678.21 (+/- 30 PSF). Thank you for your attention to this matter. Submitted by: PAUL WELCH INC. Paul Welch, P.E. Reg. No 29945 Attached: Product Approval Affid. Area of WorkPldn * lut -0nj ST. LU � COUNTY BUILDTING DIVISION REVIEWED FOR CO IAIiCE REVIEWED B DATE PLANS AND PERNUT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE r*UDE. PAUL WELCH INC. Mechanical * Electrical * Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone (172) 785 - 9888 Email pwelchinc@aol.com Door Replacement 3001 Industrial 3 Ave. Fort Pierce, FL 34946 AA W J A ouANNED BY 3 1 iriP i;OWItV A 18'-2" W X 14'-0" H Overhead Door (REPLACE EXISTING) AREA OF WORK PLAN nts... NORTH Paul Welch, P.E., Reg. No 29945 February 8, 2017